943 resultados para LONGITUDINAL MODE-OPERATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many of the power utilities around the world experienced spurious tripping of directional earth fault relays in their mesh distribution networks due to induced circulating currents. This circulating current is zero sequence and induced in the healthy circuit due to the zero sequence current flow resulting from a ground fault of a parallel circuit. This paper quantitatively discusses the effects of mutual coupling on earth fault protection of distribution systems. An actual spurious tripping event is analyzed to support the theory and to present options for improved resilience to spurious tripping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Australian tourism tertiary education sector operates in a competitive and dynamic environment, which necessitates a market orientation to be successful. Academic staff and management in the sector must regularly assess the perceptions of prospective and current students and monitor the satisfaction levels of current students. This study is concerned with the setting and monitoring of satisfaction levels of current students, reporting the results of three longitudinal investigations of student satisfaction in a postgraduate unit. The study also addresses a limitation of a university’s generic teaching evaluation instrument. Importance-Performance Analysis (IPA) has been recommended as a simple but effective tool for overcoming the deficiencies of many student evaluation studies, which have generally measured only attribute performance at the end of a semester. IPA was used to compare student expectations of the unit at the beginning of a semester with their perceptions of performance 10 weeks later. The first stage documented key benchmarks for which amendments to the unit based on student feedback could be evaluated during subsequent teaching periods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To identify agreement levels between conventional longitudinal evaluation of change (post–pre) and patient-perceived change (post–then test) in health-related quality of life. Design: A prospective cohort investigation with two assessment points (baseline and six-month follow-up) was implemented. Setting: Community rehabilitation setting. Subjects: Frail older adults accessing community-based rehabilitation services. Intervention: Nil as part of this investigation. Main measures: Conventional longitudinal change in health-related quality of life was considered the difference between standard EQ-5D assessments completed at baseline and follow-up. To evaluate patient-perceived change a ‘then test’ was also completed at the follow-up assessment. This required participants to report (from their current perspective) how they believe their health-related quality of life was at baseline (using the EQ-5D). Patient-perceived change was considered the difference between ‘then test’ and standard follow-up EQ-5D assessments. Results: The mean (SD) age of participants was 78.8 (7.3). Of the 70 participants 62 (89%) of data sets were complete and included in analysis. Agreement between conventional (post–pre) and patient-perceived (post–then test) change was low to moderate (EQ-5D utility intraclass correlation coefficient (ICC)¼0.41, EQ-5D visual analogue scale (VAS) ICC¼0.21). Neither approach inferred greater change than the other (utility P¼0.925, VAS P¼0.506). Mean (95% confidence interval (CI)) conventional change in EQ-5D utility and VAS were 0.140 (0.045,0.236) and 8.8 (3.3,14.3) respectively, while patient-perceived change was 0.147 (0.055,0.238) and 6.4 (1.7,11.1) respectively. Conclusions: Substantial disagreement exists between conventional longitudinal evaluation of change in health-related quality of life and patient-perceived change in health-related quality of life (as measured using a then test) within individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To explore the extent of and factors associated with male residents who change wandering status post nursing home admission. Design Longitudinal design with secondary data analyses. Admissions over a 4-year period were examined using repeat assessments with the Minimum Data Set (MDS) to formulate a model understanding the development of wandering behavior. Setting One hundred thirty-four Veterans Administration (VA) nursing homes throughout the United States. Participants: Included 6673 residents admitted to VA nursing homes between October 2000 and October 2004. Measurements MDS variables (cognitive impairment, mood, behavior problems, activities of daily living and wandering) included ratings recorded at residents’ admission to the nursing home and a minimum of two other time points at quarterly intervals. Results The majority (86%) of the sample were classified as non wanderers at admission and most of these (94%) remained non wanderers until discharge or the end of the study. Fifty one per cent of the wanderers changed status to non wanderers with 6% of these residents fluctuating in status more than two times. Admission variables associated with an increased risk of changing status from non-wandering to wandering included older age, greater cognitive impairment, more socially inappropriate behavior, resisting care, easier distractibility, and needing less help with personal hygiene. Requiring assistance with locomotion and having three or more medical comorbidities were associated with a decreased chance of changing from non-wandering to wandering status. Conclusion A resident’s change from non-wandering to wandering status may reflect an undetected medical event that affects cognition, but spares mobility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Common mode voltage generated by a power converter in combination with parasitic capacitive couplings is a potential source of shaft voltage in an AC motor drive system. In this paper, a three-phase motor drive system supplied with a single-phase AC-DC diode rectifier is investigated in order to reduce shaft voltage in a three-phase AC motor drive system. In this topology, the common mode voltage generated by the inverter is influenced by the AC-DC diode rectifier because the placement of the neutral point is changing in different rectifier circuit states. A pulse width modulation technique is presented by a proper placement of the zero vectors to reduce the common mode voltage level, which leads to a cost effective shaft voltage reduction technique without load current distortion, while keeping the switching frequency constant. Analysis and simulations have been presented to investigate the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparison are required to understand transport benefits of Transit Oriented Developments (TODs). Mode shares of TOD users need to be understood. Accurate travel demand models for TODs are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of constructability uses integration art of individual functions through a valuable and timely construction inputs into planning and design development stages. It results in significant savings in cost and time needed to finalize infrastructure projects. However, available constructability principles, developed by CII Australia (1993), do not cover Operation and Maintenance (O&M) phases of projects, whilst major cost and time in multifaceted infrastructure projects are spent in post-occupancy stages. This paper discusses the need to extend the constructability concept by examining current O&M issues in the provision of multifaceted building projects. It highlights available O&M problems and shortcomings of building projects, as well as their causes and reasons in different categories. This initial categorization is an efficient start point for testing probable present O&M issues in various cases of complex infrastructure building projects. This preliminary categorization serve as a benchmark to develop an extended constructability model that considers the whole project life cycle phases rather than a specific phase. It anticipates that the development of an extended constructability model can reduce significant number of reworks, mistakes, extra costs and time wasted during delivery stages of multifaceted building projects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to differentiate from competitors through the selection of unique offerings is an important cornerstone of competitive performance. Developing unique products and services to offer in the marketplace is not only important for established firms, but also an important strategic choice for young firms (Baum and Haveman, 1997). Unlike large and established firms, young firms tend to have less access to adequate resources, well-developed sources of information, contact networks, and considerable experience and management know-how. That is, these firms differ significantly in their attributes and performance from larger and well-established firms (c.f. Miller and Chen, 1994). Although young firms are disadvantaged by the paucity of resources in putting together its unique product offering(s), they develop different pathways in advancing their assortment of capabilities that enables them to stay ahead of competitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the rapid increase in electrical energy demand, power generation in the form of distributed generation is becoming more important. However, the connections of distributed generators (DGs) to a distribution network or a microgrid can create several protection issues. The protection of these networks using protective devices based only on current is a challenging task due to the change in fault current levels and fault current direction. The isolation of a faulted segment from such networks will be difficult if converter interfaced DGs are connected as these DGs limit their output currents during the fault. Furthermore, if DG sources are intermittent, the current sensing protective relays are difficult to set since fault current changes with time depending on the availability of DG sources. The system restoration after a fault occurs is also a challenging protection issue in a converter interfaced DG connected distribution network or a microgrid. Usually, all the DGs will be disconnected immediately after a fault in the network. The safety of personnel and equipment of the distribution network, reclosing with DGs and arc extinction are the major reasons for these DG disconnections. In this thesis, an inverse time admittance (ITA) relay is proposed to protect a distribution network or a microgrid which has several converter interfaced DG connections. The ITA relay is capable of detecting faults and isolating a faulted segment from the network, allowing unfaulted segments to operate either in grid connected or islanded mode operations. The relay does not make the tripping decision based on only the fault current. It also uses the voltage at the relay location. Therefore, the ITA relay can be used effectively in a DG connected network in which fault current level is low or fault current level changes with time. Different case studies are considered to evaluate the performance of the ITA relays in comparison to some of the existing protection schemes. The relay performance is evaluated in different types of distribution networks: radial, the IEEE 34 node test feeder and a mesh network. The results are validated through PSCAD simulations and MATLAB calculations. Several experimental tests are carried out to validate the numerical results in a laboratory test feeder by implementing the ITA relay in LabVIEW. Furthermore, a novel control strategy based on fold back current control is proposed for a converter interfaced DG to overcome the problems associated with the system restoration. The control strategy enables the self extinction of arc if the fault is a temporary arc fault. This also helps in self system restoration if DG capacity is sufficient to supply the load. The coordination with reclosers without disconnecting the DGs from the network is discussed. This results in increased reliability in the network by reduction of customer outages.