995 resultados para Internal Dose
Resumo:
Peeling the internal limiting membrane of the retina has become a very common procedure performed by vitreo-retinal surgeons. The combination of new microsurgical instrumentation with the availability of different dyes to stain this thin and transparent membrane has facilitated the performance of internal limiting membrane peeling, reducing the time and trauma associated with this maneuver. Internal limiting membrane peeling has been used to treat a variety of retinal pathologies, including full-thickness macular hole, epiretinal membrane, macular edema, vitreomacular traction syndrome, and Terson syndrome, among others. Although it appears that peeling the internal limiting membrane in these retinal conditions may be associated with better anatomical and visual outcomes following surgery, further evidence through randomized controlled clinical trials is still needed to guide the vitreo-retinal surgeon on the appropriate use of this surgical maneuver. © 2008 Elsevier Inc. All rights reserved.
Resumo:
PURPOSE: To report the use of perfluorohexyloctane, a liquid semifluorinated alkane that is heavier than water, as an internal tamponade agent in surgery for complicated retinal detachments. DESIGN: A consecutive interventional case series from three study centers. METHODS: In 23 consecutive eyes (23 patients, 19 men and four women, mean ± standard deviation (SD) age of 58.5 years ± 16.1) perfluorohexyloctane was used for long-term internal tamponade. Included were eyes with complicated retinal detachment involving the lower two quadrants of the fundus. Excluded were patients with diseases in the fellow eye or severe systemic disease. A pars plana vitrectomy was performed, including membrane peeling and retinotomy where necessary. RESULTS: The mean duration for perfluorohexyloctane being left in situ was 76 days (SD 37.64) (range, 35-202 days). Four weeks following the removal of perfluorohexyloctane 19 of the 23 patients had total reattachment of the retina; three eyes had a recurrence of retinal detachment. One patient was lost to follow-up. The mean follow-up after perfluorohexyloctane removal was 97 days (range, 48 to 169 days). Cataract formation or progression was noted in nine of the 10 eyes. There were two cases with high intraocular pressures. Dispersion into small droplets was observed as early as 3 days postoperatively in three of the 23 patients. At least 12 of the 23 patients had an obvious dispersion by the time of perfluorohexyloctane removal. There was no sign of optic atrophy, retinal necrosis, or retinal vascular occlusion. CONCLUSION: Perfluorohexyloctane was tolerated as a long-term internal tamponade agent without obvious signs of damage to the retina or optic disk. Of all the complications noted, the most common was that of dispersion of the perfluorohexyloctane bubble into droplets. © 2002 by Elsevier Science Inc. All rights reserved.
Resumo:
Background: Fluticasone propionate was introduced in 1993 in the UK as a potentially safer inhaled corticosteroid than those already in use. The efficacy and safety of fluticasone has been established at recommended doses of 200 µg/day, but not at the higher doses that are often used.
Methods: Growth retardation was observed in six severely asthmatic children after introduction of high-dose fluticasone propionate treatment (dry powder). Assessment of cortisol response was by insulin-induced hypoglycaemia in three cases, by short tetracosactrin test in two, and by low-dose tetracosactrin and 24-hour urinary cortisol/creatinine ratio in one.
Findings: Six children with growth retardation noted after treatment with high-dose fluticasone propionate were found to have adrenal suppression. In one case the growth rate and cortisol response returned to normal 9 months after the fluticasone dose was reduced to 500 µg/day.
Interpretation: When high doses of fluticasone propionate are used, growth may be retarded and adrenal suppression may occur.
Resumo:
The adoption of each new level of automotive emissions legislation often requires the introduction of additional emissions reduction techniques or the development of existing emissions control systems. This, in turn, usually requires the implementation of new sensors and hardware which must subsequently be monitored by the on-board fault detection systems. The reliable detection and diagnosis of faults in these systems or sensors, which result in the tailpipe emissions rising above the progressively lower failure thresholds, provides enormous challenges for OBD engineers. This paper gives a review of the field of fault detection and diagnostics as used in the automotive industry. Previous work is discussed and particular emphasis is placed on the various strategies and techniques employed. Methodologies such as state estimation, parity equations and parameter estimation are explained with their application within a physical model diagnostic structure. The utilization of symptoms and residuals in the diagnostic process is also discussed. These traditional physical model based diagnostics are investigated in terms of their limitations. The requirements from the OBD legislation are also addressed. Additionally, novel diagnostic techniques, such as principal component analysis (PCA) are also presented as a potential method of achieving the monitoring requirements of current and future OBD legislation.
Resumo:
This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.
Resumo:
OBJECTIVE To assess the association between circulating angiogenic and antiangiogenic factors in the second trimester and risk of preeclampsia in women with type 1 diabetes.
RESEARCH DESIGN AND METHODS Maternal plasma concentrations of placental growth factor (PlGF), soluble fms-like tyrosine kinase 1 (sFlt-1), and soluble endoglin (sEng) were available at 26 weeks of gestation in 540 women with type 1 diabetes enrolled in the Diabetes and Preeclampsia Intervention Trial.
RESULTS Preeclampsia developed in 17% of pregnancies (n = 94). At 26 weeks of gestation, women in whom preeclampsia developed later had significantly lower PlGF (median [interquartile range]: 231 pg/mL [120–423] vs. 365 pg/mL [237–582]; P < 0.001), higher sFlt-1 (1,522 pg/mL [1,108–3,393] vs. 1,193 pg/mL [844–1,630] P < 0.001), and higher sEng (6.2 ng/mL [4.9–7.9] vs. 5.1 ng/mL[(4.3–6.2]; P < 0.001) compared with women who did not have preeclampsia. In addition, the ratio of PlGF to sEng was significantly lower (40 [17–71] vs. 71 [44–114]; P < 0.001) and the ratio of sFlt-1 to PlGF was significantly higher (6.3 [3.4–15.7] vs. 3.1 [1.8–5.8]; P < 0.001) in women who later developed preeclampsia. The addition of the ratio of PlGF to sEng or the ratio of sFlt-1 to PlGF to a logistic model containing established risk factors (area under the curve [AUC], 0.813) significantly improved the predictive value (AUC, 0.850 and 0.846, respectively; P < 0.01) and significantly improved reclassification according to the integrated discrimination improvement index (IDI) (IDI scores 0.086 and 0.065, respectively; P < 0.001).
CONCLUSIONS These data suggest that angiogenic and antiangiogenic factors measured during the second trimester are predictive of preeclampsia in women with type 1 diabetes. The addition of the ratio of PlGF to sEng or the ratio of sFlt-1 to PlGF to established clinical risk factors significantly improves the prediction of preeclampsia in women with type 1 diabetes.
Preeclampsia is characterized by the development of hypertension and new-onset proteinuria during the second half of pregnancy (1,2), leading to increased maternal morbidity and mortality (3). Women with type 1 diabetes are at increased risk for development of preeclampsia during pregnancy, with rates being two-times to four-times higher than that of the background maternity population (4,5). Small advances have come from preventive measures, such as low-dose aspirin in women at high risk (6); however, delivery remains the only effective intervention, and preeclampsia is responsible for up to 15% of preterm births and a consequent increase in infant mortality and morbidity (7).
Although the etiology of preeclampsia remains unclear, abnormal placental vascular remodeling and placental ischemia, together with maternal endothelial dysfunction, hemodynamic changes, and renal pathology, contribute to its pathogenesis (8). In addition, over the past decade accumulating evidence has suggested that an imbalance between angiogenic factors, such as placental growth factor (PlGF), and antiangiogenic factors, such as soluble fms-like tyrosine kinase 1 (sFlt-1) and soluble endoglin (sEng), plays a key role in the pathogenesis of preeclampsia (8,9). In women at low risk (10–13) and women at high risk (14,15), concentrations of angiogenic and antiangiogenic factors are significantly different between women who later develop preeclampsia (lower PlGF, higher sFlt-1, and higher sEng levels) compared with women who do not.
Few studies have specifically focused on circulating angiogenic factors and risk of preeclampsia in women with diabetes, and the results have been conflicting. In a small study, higher sFlt-1 and lower PlGF were reported at the time of delivery in women with diabetes who developed preeclampsia (16). In a longitudinal prospective cohort of pregnant women with diabetes, Yu et al. (17) reported increased sFlt-1 and reduced PlGF in the early third trimester as potential predictors of preeclampsia in women with type 1 diabetes, but they did not show any difference in sEng levels in women with preeclampsia compared with women without preeclampsia. By contrast, Powers et al. (18) reported only increased sEng in the second trimester in women with pregestational diabetes who developed preeclampsia.
The aim of this study, which was significantly larger than the previous studies highlighted, was to assess the association between circulating angiogenic (PlGF) and antiangiogenic (sFlt-1 and sEng) factors and the risk of preeclampsia in women with type 1 diabetes. A further aim was to evaluate the added predictive ability and clinical usefulness of angiogenic factors and established risk factors for preeclampsia risk prediction in women with type 1 diabetes.
Resumo:
To evaluate the dose-response relationship of lixisenatide (AVE0010), a glucagon-like peptide-1 (GLP-1) receptor agonist, in metformin-treated patients with Type 2 diabetes.
Resumo:
The potential that laser based particle accelerators offer to solve sizing and cost issues arising with conventional proton therapy has generated great interest in the understanding and development of laser ion acceleration, and in investigating the radiobiological effects induced by laser accelerated ions. Laser-driven ions are produced in bursts of ultra-short duration resulting in ultra-high dose rates, and an investigation at Queen's University Belfast was carried out to investigate this virtually unexplored regime of cell rdaiobiology. This employed the TARANIS terawatt laser producing protons in the MeV range for proton irradiation, with dose rates exceeding 10 Gys on a single exposure. A clonogenic assay was implemented to analyse the biological effect of proton irradiation on V79 cells, which, when compared to data obtained with the same cell line irradiated with conventionally accelerated protons, was found to show no significant difference. A Relative Biological effectiveness of 1.4±0.2 at 10 % Survival Fraction was estimated from a comparison with a 225 kVp X-ray source. © 2013 SPIE.
Resumo:
Modified lipoproteins induce autoimmune responses including the synthesis of autoantibodies with pro-inflammatory characteristics. Circulating modified lipoprotein autoantibodies combine with circulating antigens and form immune complexes (IC). We now report the results of a study investigating the role of circulating IC containing modified lipoproteins in the progression of carotid intima-media thickness (IMT) in patients enrolled in the Epidemiology of Diabetes Interventions and Complications (EDIC) Trial, a follow-up study of the Diabetes Control and Complications Trial (DCCT). This cohort includes 1229 patients with type 1 diabetes in whom B-mode ultrasonography of internal and common carotid arteries was performed in 1994-1996 and in 1998-2000. Conventional CHD risk factors, antibodies against modified forms of LDL and modified lipoprotein IC were determined in 1050 of these patients from blood collected in 1996-1998. Cholesterol and apolipoprotein B content of IC (surrogate markers of modified ApoB-rich lipoproteins) were significantly higher in patients who showed progression of the internal carotid IMT than in those showing no progression, regression or mild progression. Multivariate linear and logistic regression modeling using conventional and non-conventional risk factors showed that the cholesterol content of IC was a significant positive predictor of internal carotid IMT progression. In conclusion these data demonstrate that increased levels of modified ApoB-rich IC are associated with increased progression of internal carotid IMT in the DCCT/EDIC cohort of type 1 diabetes.
Resumo:
Several observational studies have suggested the potential benefit of internal limiting membrane (ILM) peeling to treat idiopathic full-thickness macular hole (FTMH). However, no strong evidence is available on the potential benefit(s) of this surgical manoeuvre and uncertainty remains among vitreoretinal surgeons about the indication for peeling the ILM, whether to use it in all cases or in long-standing and/or larger holes.
Resumo:
Studies regarding the radiobiological effects of low dose radiation, microbeam irradiation services have been developed in the world and today laser acceleration of protons and heavy ions may be used in radiation therapy. The application of different facilities is essential for studying bystander effects and relating signalling phenomena in different cells or tissues. In particular the use of ion beams results advantageous in cancer radiotherapy compared to more commonly used X-rays, since the ability of ions in delivering lethal amount of doses into the target tumour avoiding or limiting damage to the contiguous healthy tissues. At the INFN-LNS in Catania, a multidisciplinary radiobiology group is strategically structured aimed to develop radiobiological research, finalised to therapeutic applications, compatible with the use of high dose laser-driven ion beams. The characteristic non-continuous dose rates with several orders of magnitude of laser-driven ion beams makes this facility very interesting in the cellular systems' response to ultra-high dose rates with non-conventional pulse time intervals cellular studies. Our group have projected to examine the effect of high dose laser-driven ion beams on two cellular types: foetal fibroblasts (normal control cells) and DU145 (prostate cancer cells), studying the modulation of some different bio-molecular parameters, in particular cell proliferation and viability, DNA damage, redox cellular status, morphological alterations of both the cytoskeleton components and some cell organelles and the possible presence of apoptotic or necrotic cell death. Our group performed preliminary experiments with high energy (60 MeV), dose rate of 10 Gy/min, doses of 1, 2, 3 Gy and LET 1 keV/µm on human foetal fibroblasts (control cells). We observed that cell viability was not influenced by the characteristics of the beam, the irradiation conditions or the analysis time. Conversely, DNA damage was present at time 0, immediately following irradiation in a dose-dependent manner. The analysis of repair capability showed that the cells irradiated with 1 and 2 Gy almost completely recovered from the damage, but not, however, 3 Gy treated cells in which DNA damage was not recovered. In addition, the results indicate the importance of the use of an appropriate control in radiobiological in vitro analysis.
Resumo:
This study describes ultrastructural changes in the pigmented hooded Lister rat retina, 3-12 months following X-irradiation with single doses of between 200 and 2000 cGy. The extreme radiosensitivity of the photoreceptor cells was underlined by the continued manifestation of fine structural changes and cell death up to 6 months post-radiation in animals receiving doses above 500 cGy. The retinal pigment epithelial (RPE) cells were more radioresistant than photoreceptors and RPE cell loss was only observed at doses of more than 1500 cGy. One year after irradiation with 1500 cGy the retinal vasculature showed capillary occlusion with some evidence of recanalisation. Telangiectasia was observed in the large retinal veins. Although the inner retinal neurones and glial cells showed no evidence of direct radiation damage, the nerve fibre layer adjacent to occluded retinal vessels demonstrated ultrastructural evidence of ischaemic neuropathy and retinal oedema. At doses above 1500 cGy the choriocapillaris showed platelet aggregation and capillary loss.
Resumo:
In this study Lister rats were given doses of X-rays ranging from 200-2,000 Rads to the retina of one eye, sacrificed at various time intervals between one hour and one month later and the irradiated eye processed for electron microscopy. The rod photoreceptor cells were by far the most radiosensitive cells in the retina, their outer segments showing distinctive membrane damage at one hour after 200 Rads of X-rays. Photoreceptor cell death was not seen at doses less than 1,000 Rads in the time period of the experiment. The retinal pigment epithelial (RPE) cells showed damage in the form of mitochondrial swelling but only in doses over 500 Rads. Retinal pigment epithelial cell loss did not occur under 2,000 Rads. The inner retinal neurones, glial elements and the retinal vasculature did not show any ill effects in the time period of this study.