862 resultados para Higher Order Spectra, Heart Rate Variability, Cardiac State, Signal Analysis, Classification


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A universal lack of attention to the professional learning needs of teacher educators is the driver for this study, which considers the most effective ways to support the professional learning of higher education-based teacher educators. At a time when many industrialised countries are engaged in systemic educational reform, this study provides an international and comparative needs analysis through a survey of 1,158 higher education-based teacher educators in the countries participating in the International Forum for Teacher Educator Development (InFo-TED): Belgium, Ireland, Israel, the Netherlands, Norway and the UK. Our results suggest that while teacher educators are only moderately satisfied with their professional development experiences, a strong desire exists for further professional learning. This desire, influenced by their professional context, relates to their current beliefs concerning ‘best practice’ in teacher education, the academic skills required to further their professional careers and knowledge of the curriculum associated with their fields of expertise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Understanding the basis of normal heart remodeling can provide insight into the plasticity of the cardiac state, and into the potential for treating diseased tissue. In Drosophila, the adult heart arises during metamorphosis from a series of events, that include the remodeling of an existing cardiac tube, the elaboration of new inflow tracts, and the addition of a layer of longitudinal muscle fibers. We have identified genes active in all these three processes, and studied their expression in order to characterize in greater detail normal cardiac remodeling. Using a Transglutaminase-lacZ transgenic line, that is expressed in the inflow tracts of the larval and adult heart, we confirm the existence of five inflow tracts in the adult structure. In addition, expression of the Actin87E actin gene is initiated in the remodeling cardiac tube, but not in the longitudinal fibers, and we have identified an Act87E promoter fragment that recapitulates this switch in expression. We also establish that the longitudinal fibers are multinucleated, characterizing these cells as specialized skeletal muscles. Furthermore, we have defined the origin of the longitudinal fibers, as a subset of lymph gland cells associated with the larval dorsal vessel. These studies underline the myriad contributors to the formation of the adult Drosophila heart, and provide new molecular insights into the development of this complex organ. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. To study mortality trends related to Chagas disease taking into account all mentions of this cause listed on any line or part of the death certificate. Methods. Mortality data for 1985-2006 were obtained from the multiple cause-of-death database maintained by the Sao Paulo State Data Analysis System (SEADE). Chagas disease was classified as the underlying cause-of-death or as an associated cause-of-death (non-underlying). The total number of times Chagas disease was mentioned on the death certificates was also considered. Results. During this 22-year period, there were 40 002 deaths related to Chagas disease: 34 917 (87.29%) classified as the underlying cause-of-death and 5 085 (12.71%) as an associated cause-of-death. The results show a 56.07% decline in the death rate due to Chagas disease as the underlying cause and a stabilized rate as associated cause. The number of deaths was 44.5% higher among men. The fact that 83.5% of the deaths occurred after 45 years of age reflects a cohort effect. The main causes associated with Chagas disease as the underlying cause-of-death were direct complications due to cardiac involvement, such as conduction disorders, arrhythmias and heart failure. Ischemic heart disease, cerebrovascular disorders and neoplasms were the main underlying causes when Chagas was an associated cause-of-death. Conclusions. For the total mentions to Chagas disease, a 51.34% decline in the death rate was observed, whereas the decline in the number of deaths was only 5.91%, being lower among women and showing a shift of deaths to older age brackets. Using the multiple cause-of-death method contributed to the understanding of the natural history of Chagas disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The complex human behavior related to exercise involves cognitive, physical and emotional processing. The recent theories about exercise s intensity regulation have highlighted the role played by psychophysics aspects in controlling exercise s intensity. In this regard, recent evidences have shown that there is variability in human capacity in perceiving interoceptives clues. Thus, subjects more sensitive show higher physiological arousal to physical and/or emotional stress, and sensations with higher intensity. In fact, studies have evidenced that interoceptive feedback modifies behavior in exercise with free load. However, exercise recommendations are based in a constant load standard. Therefore, we aimed to analyze the influence of interoceptive sensibility on psychophysics responses during dynamic exercise performed with constant load. Twenty-four adult males were allocated into two groups accordingly with their interoceptive sensibility: high sensibility (n=11) and low sensibility (13). They underwent to an incremental test (IT) and then randomly to two sections of moderate and severe exercise intensity for 20 minutes. Heart rate (HR), rating of perceived exertion (RPE), affective feelings (AF), alert state (AS), and percentage of associative thoughts were collect during exercise. A two-way ANOVA with repeated measures was used to assess differences between psychophysics responses. There were differences between group in RPE, AF, and AS in moderate intensity. There was no difference in any measure in severe intensity. We conclude that subjects with high interoceptive sensibility feel dynamic moderate exercise more intense than the subjecs with low interoceptive sensibility

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction .The renal prostaglandins (PGs), vasodilators, preserve kidney function during increased activity of the renin-angiotensin system or renal sympathetic nerves (renal PG-dependent state [RPGD]). Ketoprofen (Ket) inhibits cyclooxygenase and, therefore, the synthesis of PGs. The aim of this study was to determine, in the rat, the action of Ket in the renal histology and function in a RPGD state (stress of anesthesia and hemorrhage). Material and Methods . Twenty male Wistar rats, anesthetized with sodium pentobarbital, were randomly divided into two groups: G1-control ( n = 10) and G2-Ket ( n = 10) submitted to arterial hemorrhage of 30% of volemia (estimated as 6% of body weight) three times (10% each 10 min), 65 min after anesthesia. G2 animals received Ket, 1.5 mg. kg -1 , venously, 5 min after anesthesia and 60 min before the first hemorrhage moment (first moment of the study [M1]). Medium arterial pressure (MAP), rectal temperature (T), and heart rate were monitored. G1 and G2 received para-aminohippurate sodium (PAH) and iothalamate sodium (IOT) solutions during the entire experimental time in order to determine clearance of PAH (effective renal plasma flow [ERPF]) and clearance of IOT (glomerular filtration rate [GFR]) without urine collection (determination of blood concentrations of PAH and IOT through the high-performance liquid chromatography), filtration fraction (FF), and renal vascular resistance (RVR). The animals were sacrificed in M3, 30 min after the third hemorrhage (M2) moment, and the kidneys and blood collected during the hemorrhage periods were utilized for histological study and determinations of hematocrit (Ht), serum creatinine (S Cr ), ERPF, GFR, FF, and RVR, respectively. Results . There were significant reductions of MAP, T, and Ht and a significant increase of S Cr . During the experiment, ERPF and GFR did not change, but ERPF was always higher in G1 than in G2. Ket did not alter FF, which increased in G1 over the duration of experiment. The Ket group had significantly higher RVR than the control group. The histology verified that both G1 and G2 were similar for tubular dilation and necrosis, but they were significantly different for tubular degeneration: G1 > G2. Conclusion . The changes observed in kidney histology probably were determined by hemorrhage and hypotension. Ket inhibited the synthesis of PGs and diminished tubular degeneration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work is structured as follows: In Section 1 we discuss the clinical problem of heart failure. In particular, we present the phenomenon known as ventricular mechanical dyssynchrony: its impact on cardiac function, the therapy for its treatment and the methods for its quantification. Specifically, we describe the conductance catheter and its use for the measurement of dyssynchrony. At the end of the Section 1, we propose a new set of indexes to quantify the dyssynchrony that are studied and validated thereafter. In Section 2 we describe the studies carried out in this work: we report the experimental protocols, we present and discuss the results obtained. Finally, we report the overall conclusions drawn from this work and we try to envisage future works and possible clinical applications of our results. Ancillary studies that were carried out during this work mainly to investigate several aspects of cardiac resynchronization therapy (CRT) are mentioned in Appendix. -------- Ventricular mechanical dyssynchrony plays a regulating role already in normal physiology but is especially important in pathological conditions, such as hypertrophy, ischemia, infarction, or heart failure (Chapter 1,2.). Several prospective randomized controlled trials supported the clinical efficacy and safety of cardiac resynchronization therapy (CRT) in patients with moderate or severe heart failure and ventricular dyssynchrony. CRT resynchronizes ventricular contraction by simultaneous pacing of both left and right ventricle (biventricular pacing) (Chapter 1.). Currently, the conductance catheter method has been used extensively to assess global systolic and diastolic ventricular function and, more recently, the ability of this instrument to pick-up multiple segmental volume signals has been used to quantify mechanical ventricular dyssynchrony. Specifically, novel indexes based on volume signals acquired with the conductance catheter were introduced to quantify dyssynchrony (Chapter 3,4.). Present work was aimed to describe the characteristics of the conductancevolume signals, to investigate the performance of the indexes of ventricular dyssynchrony described in literature and to introduce and validate improved dyssynchrony indexes. Morevoer, using the conductance catheter method and the new indexes, the clinical problem of the ventricular pacing site optimization was addressed and the measurement protocol to adopt for hemodynamic tests on cardiac pacing was investigated. In accordance to the aims of the work, in addition to the classical time-domain parameters, a new set of indexes has been extracted, based on coherent averaging procedure and on spectral and cross-spectral analysis (Chapter 4.). Our analyses were carried out on patients with indications for electrophysiologic study or device implantation (Chapter 5.). For the first time, besides patients with heart failure, indexes of mechanical dyssynchrony based on conductance catheter were extracted and studied in a population of patients with preserved ventricular function, providing information on the normal range of such a kind of values. By performing a frequency domain analysis and by applying an optimized coherent averaging procedure (Chapter 6.a.), we were able to describe some characteristics of the conductance-volume signals (Chapter 6.b.). We unmasked the presence of considerable beat-to-beat variations in dyssynchrony that seemed more frequent in patients with ventricular dysfunction and to play a role in discriminating patients. These non-recurrent mechanical ventricular non-uniformities are probably the expression of the substantial beat-to-beat hemodynamic variations, often associated with heart failure and due to cardiopulmonary interaction and conduction disturbances. We investigated how the coherent averaging procedure may affect or refine the conductance based indexes; in addition, we proposed and tested a new set of indexes which quantify the non-periodic components of the volume signals. Using the new set of indexes we studied the acute effects of the CRT and the right ventricular pacing, in patients with heart failure and patients with preserved ventricular function. In the overall population we observed a correlation between the hemodynamic changes induced by the pacing and the indexes of dyssynchrony, and this may have practical implications for hemodynamic-guided device implantation. The optimal ventricular pacing site for patients with conventional indications for pacing remains controversial. The majority of them do not meet current clinical indications for CRT pacing. Thus, we carried out an analysis to compare the impact of several ventricular pacing sites on global and regional ventricular function and dyssynchrony (Chapter 6.c.). We observed that right ventricular pacing worsens cardiac function in patients with and without ventricular dysfunction unless the pacing site is optimized. CRT preserves left ventricular function in patients with normal ejection fraction and improves function in patients with poor ejection fraction despite no clinical indication for CRT. Moreover, the analysis of the results obtained using new indexes of regional dyssynchrony, suggests that pacing site may influence overall global ventricular function depending on its relative effects on regional function and synchrony. Another clinical problem that has been investigated in this work is the optimal right ventricular lead location for CRT (Chapter 6.d.). Similarly to the previous analysis, using novel parameters describing local synchrony and efficiency, we tested the hypothesis and we demonstrated that biventricular pacing with alternative right ventricular pacing sites produces acute improvement of ventricular systolic function and improves mechanical synchrony when compared to standard right ventricular pacing. Although no specific right ventricular location was shown to be superior during CRT, the right ventricular pacing site that produced the optimal acute hemodynamic response varied between patients. Acute hemodynamic effects of cardiac pacing are conventionally evaluated after stabilization episodes. The applied duration of stabilization periods in most cardiac pacing studies varied considerably. With an ad hoc protocol (Chapter 6.e.) and indexes of mechanical dyssynchrony derived by conductance catheter we demonstrated that the usage of stabilization periods during evaluation of cardiac pacing may mask early changes in systolic and diastolic intra-ventricular dyssynchrony. In fact, at the onset of ventricular pacing, the main dyssynchrony and ventricular performance changes occur within a 10s time span, initiated by the changes in ventricular mechanical dyssynchrony induced by aberrant conduction and followed by a partial or even complete recovery. It was already demonstrated in normal animals that ventricular mechanical dyssynchrony may act as a physiologic modulator of cardiac performance together with heart rate, contractile state, preload and afterload. The present observation, which shows the compensatory mechanism of mechanical dyssynchrony, suggests that ventricular dyssynchrony may be regarded as an intrinsic cardiac property, with baseline dyssynchrony at increased level in heart failure patients. To make available an independent system for cardiac output estimation, in order to confirm the results obtained with conductance volume method, we developed and validated a novel technique to apply the Modelflow method (a method that derives an aortic flow waveform from arterial pressure by simulation of a non-linear three-element aortic input impedance model, Wesseling et al. 1993) to the left ventricular pressure signal, instead of the arterial pressure used in the classical approach (Chapter 7.). The results confirmed that in patients without valve abnormalities, undergoing conductance catheter evaluations, the continuous monitoring of cardiac output using the intra-ventricular pressure signal is reliable. Thus, cardiac output can be monitored quantitatively and continuously with a simple and low-cost method. During this work, additional studies were carried out to investigate several areas of uncertainty of CRT. The results of these studies are briefly presented in Appendix: the long-term survival in patients treated with CRT in clinical practice, the effects of CRT in patients with mild symptoms of heart failure and in very old patients, the limited thoracotomy as a second choice alternative to transvenous implant for CRT delivery, the evolution and prognostic significance of diastolic filling pattern in CRT, the selection of candidates to CRT with echocardiographic criteria and the prediction of response to the therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Diastolic heart failure (DHF) is characterized by dyspnea due to increased left ventricular (LV) filling pressures during stress. We sought the relationship of exercise-induced increases in B-type natriuretic peptide (BNP) to LV filling pressures and parameters of cardiovascular performance in suspected DHF. Methods Twenty-six treated hypertensive patients with suspected DHF (exertional dyspnea, LV ejection fraction >50%, and diastolic dysfunction) underwent maximal exercise echocardiography using the Bruce protocol. BNP, transmitral Doppler, and tissue Doppler for systolic (So) and early (Ea) and late (Aa) diastolic mitral annular velocities were obtained at rest and peak stress. LV filling pressures were estimated with E/Ea ratios. Results Resting BNP correlated with resting pulse pressure (r=0.45, P=0.02). Maximal exercise performance (4.6 +/- 2.5min) was limited by dyspnea. Blood pressure increased with exercise (from 143 +/- 19/88 +/- 8 to 191 +/- 22/90 +/- 10 mm Hg); 13 patients (50%) had a hypertensive response. Peak exercise BNP correlated with peak transmitral E velocity (r = 0.41, P <.05) and peak heart rate (r = -0.40, P <.05). BNP increased with exercise (from 48 57 to 74 97 pg/mL, P =.007), and the increment of BNP with exercise was associated with maximal workload and peak exercise So, Ea, and Aa (P <.01 for all). Filling pressures, approximated by lateral E/Ea ratio, increased with exercise (7.7 +/- 2.0 to 10.0 +/- 4.8, P <.01). BNP was higher in patients with possibly elevated filling pressures at peak exercise (E/Ea >10) compared to those with normal pressures (123 +/- 124 vs 45 +/- 71 pg/mL, P =.027). Conclusions Augmentation of BNP with exercise in hypertensive patients with suspected DHF is associated with better exercise capacity, LV systolic and diastolic function, and left atrial function. Peak exercise BNP levels may identify exercise-induced elevation of filling pressures in DHF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiovascular diseases (CVDs) have reached an epidemic proportion in the US and worldwide with serious consequences in terms of human suffering and economic impact. More than one third of American adults are suffering from CVDs. The total direct and indirect costs of CVDs are more than $500 billion per year. Therefore, there is an urgent need to develop noninvasive diagnostics methods, to design minimally invasive assist devices, and to develop economical and easy-to-use monitoring systems for cardiovascular diseases. In order to achieve these goals, it is necessary to gain a better understanding of the subsystems that constitute the cardiovascular system. The aorta is one of these subsystems whose role in cardiovascular functioning has been underestimated. Traditionally, the aorta and its branches have been viewed as resistive conduits connected to an active pump (left ventricle of the heart). However, this perception fails to explain many observed physiological results. My goal in this thesis is to demonstrate the subtle but important role of the aorta as a system, with focus on the wave dynamics in the aorta.

The operation of a healthy heart is based on an optimized balance between its pumping characteristics and the hemodynamics of the aorta and vascular branches. The delicate balance between the aorta and heart can be impaired due to aging, smoking, or disease. The heart generates pulsatile flow that produces pressure and flow waves as it enters into the compliant aorta. These aortic waves propagate and reflect from reflection sites (bifurcations and tapering). They can act constructively and assist the blood circulation. However, they may act destructively, promoting diseases or initiating sudden cardiac death. These waves also carry information about the diseases of the heart, vascular disease, and coupling of heart and aorta. In order to elucidate the role of the aorta as a dynamic system, the interplay between the dominant wave dynamic parameters is investigated in this study. These parameters are heart rate, aortic compliance (wave speed), and locations of reflection sites. Both computational and experimental approaches have been used in this research. In some cases, the results are further explained using theoretical models.

The main findings of this study are as follows: (i) developing a physiologically realistic outflow boundary condition for blood flow modeling in a compliant vasculature; (ii) demonstrating that pulse pressure as a single index cannot predict the true level of pulsatile workload on the left ventricle; (iii) proving that there is an optimum heart rate in which the pulsatile workload of the heart is minimized and that the optimum heart rate shifts to a higher value as aortic rigidity increases; (iv) introducing a simple bio-inspired device for correction and optimization of aortic wave reflection that reduces the workload on the heart; (v) deriving a non-dimensional number that can predict the optimum wave dynamic state in a mammalian cardiovascular system; (vi) demonstrating that waves can create a pumping effect in the aorta; (vii) introducing a system parameter and a new medical index, Intrinsic Frequency, that can be used for noninvasive diagnosis of heart and vascular diseases; and (viii) proposing a new medical hypothesis for sudden cardiac death in young athletes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The adequacy of anesthesia has been studied since the introduction of balanced general anesthesia. Commercial monitors based on electroencephalographic (EEG) signal analysis have been available for monitoring the hypnotic component of anesthesia from the beginning of the 1990s. Monitors measuring the depth of anesthesia assess the cortical function of the brain, and have gained acceptance during surgical anesthesia with most of the anesthetic agents used. However, due to frequent artifacts, they are considered unsuitable for monitoring consciousness in intensive care patients. The assessment of analgesia is one of the cornerstones of general anesthesia. Prolonged surgical stress may lead to increased morbidity and delayed postoperative recovery. However, no validated monitoring method is currently available for evaluating analgesia during general anesthesia. Awareness during anesthesia is caused by an inadequate level of hypnosis. This rare but severe complication of general anesthesia may lead to marked emotional stress and possibly posttraumatic stress disorder. In the present series of studies, the incidence of awareness and recall during outpatient anesthesia was evaluated and compared with that of in inpatient anesthesia. A total of 1500 outpatients and 2343 inpatients underwent a structured interview. Clear intraoperative recollections were rare the incidence being 0.07% in outpatients and 0.13% in inpatients. No significant differences emerged between outpatients and inpatients. However, significantly smaller doses of sevoflurane were administered to outpatients with awareness than those without recollections (p<0.05). EEG artifacts in 16 brain-dead organ donors were evaluated during organ harvest surgery in a prospective, open, nonselective study. The source of the frontotemporal biosignals in brain-dead subjects was studied, and the resistance of bispectral index (BIS) and Entropy to the signal artifacts was compared. The hypothesis was that in brain-dead subjects, most of the biosignals recorded from the forehead would consist of artifacts. The original EEG was recorded and State Entropy (SE), Response Entropy (RE), and BIS were calculated and monitored during solid organ harvest. SE differed from zero (inactive EEG) in 28%, RE in 29%, and BIS in 68% of the total recording time (p<0.0001 for all). The median values during the operation were SE 0.0, RE 0.0, and BIS 3.0. In four of the 16 organ donors, EEG was not inactive, and unphysiologically distributed, nonreactive rhythmic theta activity was present in the original EEG signal. After the results from subjects with persistent residual EEG activity were excluded, SE, RE, and BIS differed from zero in 17%, 18%, and 62% of the recorded time, respectively (p<0.0001 for all). Due to various artifacts, the highest readings in all indices were recorded without neuromuscular blockade. The main sources of artifacts were electrocauterization, electromyography (EMG), 50-Hz artifact, handling of the donor, ballistocardiography, and electrocardiography. In a prospective, randomized study of 26 patients, the ability of Surgical Stress Index (SSI) to differentiate patients with two clinically different analgesic levels during shoulder surgery was evaluated. SSI values were lower in patients with an interscalene brachial plexus block than in patients without an additional plexus block. In all patients, anesthesia was maintained with desflurane, the concentration of which was targeted to maintain SE at 50. Increased blood pressure or heart rate (HR), movement, and coughing were considered signs of intraoperative nociception and treated with alfentanil. Photoplethysmographic waveforms were collected from the contralateral arm to the operated side, and SSI was calculated offline. Two minutes after skin incision, SSI was not increased in the brachial plexus block group and was lower (38 ± 13) than in the control group (58 ± 13, p<0.005). Among the controls, one minute prior to alfentanil administration, SSI value was higher than during periods of adequate antinociception, 59 ± 11 vs. 39 ± 12 (p<0.01). The total cumulative need for alfentanil was higher in controls (2.7 ± 1.2 mg) than in the brachial plexus block group (1.6 ± 0.5 mg, p=0.008). Tetanic stimulation to the ulnar region of the hand increased SSI significantly only among patients with a brachial plexus block not covering the site of stimulation. Prognostic value of EEG-derived indices was evaluated and compared with Transcranial Doppler Ultrasonography (TCD), serum neuron-specific enolase (NSE) and S-100B after cardiac arrest. Thirty patients resuscitated from out-of-hospital arrest and treated with induced mild hypothermia for 24 h were included. Original EEG signal was recorded, and burst suppression ratio (BSR), RE, SE, and wavelet subband entropy (WSE) were calculated. Neurological outcome during the six-month period after arrest was assessed with the Glasgow-Pittsburgh Cerebral Performance Categories (CPC). Twenty patients had a CPC of 1-2, one patient had a CPC of 3, and nine patients died (CPC 5). BSR, RE, and SE differed between good (CPC 1-2) and poor (CPC 3-5) outcome groups (p=0.011, p=0.011, p=0.008, respectively) during the first 24 h after arrest. WSE was borderline higher in the good outcome group between 24 and 48 h after arrest (p=0.050). All patients with status epilepticus died, and their WSE values were lower (p=0.022). S-100B was lower in the good outcome group upon arrival at the intensive care unit (p=0.010). After hypothermia treatment, NSE and S-100B values were lower (p=0.002 for both) in the good outcome group. The pulsatile index was also lower in the good outcome group (p=0.004). In conclusion, the incidence of awareness in outpatient anesthesia did not differ from that in inpatient anesthesia. Outpatients are not at increased risk for intraoperative awareness relative to inpatients undergoing general anesthesia. SE, RE, and BIS showed non-zero values that normally indicate cortical neuronal function, but were in these subjects mostly due to artifacts after clinical brain death diagnosis. Entropy was more resistant to artifacts than BIS. During general anesthesia and surgery, SSI values were lower in patients with interscalene brachial plexus block covering the sites of nociceptive stimuli. In detecting nociceptive stimuli, SSI performed better than HR, blood pressure, or RE. BSR, RE, and SE differed between the good and poor neurological outcome groups during the first 24 h after cardiac arrest, and they may be an aid in differentiating patients with good neurological outcomes from those with poor outcomes after out-of-hospital cardiac arrest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To meet the growing demands of data traffic in long haul communication, it is necessary to efficiently use the low-loss region(C-band) of the optical spectrum, by increasing the no. of optical channels and increasing the bit rate on each channel But narrow pulses occupy higher spectral bandwidth. To circumvent this problem, higher order modulation schemes such as QPSK and QAM can be used to modulate the bits, which increases the spectral efficiency without demanding any extra spectral bandwidth. On the receiver side, to meet a satisfy, a given BER, the received optical signal requires to have minimum OSNR. In our study in this paper, we analyses for different modulation schemes, the OSNR required with and without preamplifier. The theoretical limit of OSNR requirement for a modulation scheme is compared for a given link length by varying the local oscillator (LO) power. Our analysis shows that as we increase the local oscillator (LO) power, the OSNR requirement decreases for a given BER. Also a combination of preamplifier and local oscillator (LO) gives the OSNR closest to theoretical limit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a recent experimental work on the excess photon detachment (EPD) of H- ions [Phys. Rev. Lett. 87 (2001) 243001] it has been found that the ponderomotive shift of each EPD peak increases with the order of the EPD channel. By using a nonperturbative quantum scattering theory, we obtain the kinetic energy spectra for the differential detachment rate along the laser polarization for several laser intensities. It is demonstrated that higher order EPD peaks are produced mainly at relatively higher laser intensities. By calculating the overall EPD spectra with varying laser intensities, it is found that the ponderomotive shift of each EPD peak increases with the order of the EPD channel. Our calculations are in good agreement with the experimental observation. It is found that different EPD channels occur mainly when the laser field reaches some values, thus the intensity distribution of the laser field is responsible for the varying ponderomotive shifts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess the appearance of cardiac troponins (cTnI and/or cTnT) after a short bout (30 s) of ‘all-out’ intense exercise and to determine the stability of any exercise-related cTnI release in response to repeated bouts of high intensity exercise separated by 7 days recovery. Eighteen apparently healthy, physically active, male university students completed two all-out 30 s cycle sprint, separated by 7 days. cTnI, blood lactate and catecholamine concentrations were measured before, immediately after and 24 h after each bout. Cycle performance, heart rate and blood pressure responses to exercise were also recorded. Cycle performance was modestly elevated in the second trial [6·5% increase in peak power output (PPO)]; there was no difference in the cardiovascular, lactate or catecholamine response to the two cycle trials. cTnI was not significantly elevated from baseline through recovery (Trial 1: 0·06 ± 0·04 ng ml−1, 0·05 ± 0·04 ng ml−1, 0·03 ± 0·02 ng ml−1; Trial 2: 0·02 ± 0·04 ng ml−1, 0·04 ± 0·03 ng ml−1, 0·05 ± 0·06 ng ml−1) in either trial. Very small within subject changes were not significantly correlated between the two trials (r = 0·06; P>0·05). Subsequently, short duration, high intensity exercise does not elicit a clinically relevant response in cTnI and any small alterations likely reflect the underlying biological variability of cTnI measurement within the participants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We study information rates of time-varying flat-fading channels (FFC) modeled as finite-state Markov channels (FSMC). FSMCs have two main applications for FFCs: modeling channel error bursts and decoding at the receiver. Our main finding in the first application is that receiver observation noise can more adversely affect higher-order FSMCs than lower-order FSMCs, resulting in lower capacities. This is despite the fact that the underlying higher-order FFC and its corresponding FSMC are more predictable. Numerical analysis shows that at low to medium SNR conditions (SNR lsim 12 dB) and at medium to fast normalized fading rates (0.01 lsim fDT lsim 0.10), FSMC information rates are non-increasing functions of memory order. We conclude that BERs obtained by low-order FSMC modeling can provide optimistic results. To explain the capacity behavior, we present a methodology that enables analytical comparison of FSMC capacities with different memory orders. We establish sufficient conditions that predict higher/lower capacity of a reduced-order FSMC, compared to its original high-order FSMC counterpart. Finally, we investigate the achievable information rates in FSMC-based receivers for FFCs. We observe that high-order FSMC modeling at the receiver side results in a negligible information rate increase for normalized fading rates fDT lsim 0.01.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The proton NMR spectra of aryl n-propyl sulfides gave rise to what may appear to be first-order proton NMR spectra. Upon oxidation to the corresponding sulfone, the spectra changed appearance dramatically and were clearly second-order. A detailed analysis of these second-order spectra, in the sulfone series, provided vicinal coupling constants which indicated that these compounds had a moderate preference for the anti-conformer, reflecting the much greater size of the sulfone over the sulfide. It also emerged, from this study, that the criterion for observing large second-order effects in the proton NMR spectra of 1,2-disubstituted ethanes was that the difference in vicinal coupling constants must be large and the difference in geminal coupling constants must be small. n-Propyl triphenylphosphonium bromide and 2-trimethylsilylethanesulfonyl chloride, and derivatives thereof, also exhibited second-order spectra, again due to the bulky substituents. Since these spectra are second-order due to magnetic nonequivalence of the nuclei in question, not chemical shifts, the proton spectra are perpetually second-order and can never be rendered first-order by using higher field NMR spectrometers.