917 resultados para Façades of buildings


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a new verification procedure for sound source coverage according to ISO 140?5 requirements. The ISO 140?5 standard applies to the measurement of façade insulation and requires a sound source able to achieve a sufficiently uniform sound field in free field conditions on the façade under study. The proposed method involves the electroacoustic characterisation of the sound source in laboratory free field conditions (anechoic room) and the subsequent prediction by computer simulation of the sound free field radiated on a rectangular surface equal in size to the façade being measured. The loudspeaker is characterised in an anechoic room under laboratory controlled conditions, carefully measuring directivity, and then a computer model is designed to calculate the acoustic free field coverage for different loudspeaker positions and façade sizes. For each sound source position, the method provides the maximum direct acoustic level differences on a façade specimen and therefore determines whether the loudspeaker verifies the maximum allowed level difference of 5 dB (or 10 dB for façade dimensions greater than 5 m) required by the ISO standard. Additionally, the maximum horizontal dimension of the façade meeting the standard is calculated and provided for each sound source position, both with the 5 dB and 10 dB criteria. In the last section of the paper, the proposed procedure is compared with another method used by the authors in the past to achieve the same purpose: in situ outdoor measurements attempting to recreate free field conditions. From this comparison, it is concluded that the proposed method is able to reproduce the actual measurements with high accuracy, for example, the ground reflection effect, at least at low frequencies, which is difficult to avoid in the outdoor measurement method, and it is fully eliminated with the proposed method to achieve the free field requisite.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The International Standard ISO 140-5 on field measurements of airborne sound insulation of façades establishes that the directivity of the measurement loudspeaker should be such that the variation in the local direct sound pressure level (ΔSPL) on the sample is ΔSPL < 5 dB (or ΔSPL < 10 dB for large façades). This condition is usually not very easy to accomplish nor is it easy to verify whether the loudspeaker produces such a uniform level. Direct sound pressure levels on the ISO standard façade essentially depend on the distance and directivity of the loudspeaker used. This paper presents a comprehensive analysis of the test geometry for measuring sound insulation and explains how the loudspeaker directivity, combined with distance, affects the acoustic level distribution on the façade. The first sections of the paper are focused on analysing the measurement geometry and its influence on the direct acoustic level variations on the façade. The most favourable and least favourable positions to minimise these direct acoustic level differences are found, and the angles covered by the façade in the reference system of the loudspeaker are also determined. Then, the maximum dimensions of the façade that meet the conditions of the ISO 140-5 standard are obtained for the ideal omnidirectional sound source and the piston radiating in an infinite baffle, which is chosen as the typical radiation pattern for loudspeakers. Finally, a complete study of the behaviour of different loudspeaker radiation models (such as those usually utilised in the ISO 140-5 measurements) is performed, comparing their radiation maps on the façade for searching their maximum dimensions and the most appropriate radiation configurations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Reducing energy consumption and eliminating wastage are among the main goals of the European Union (EU) [2]. In order to satisfy all challenges arising from the Kyoto protocol, improving energy efficiency is a very important factor to take into account. There is significant potential for reducing consumption with cost-effective measures. Some studies show that 40% of our energy is consumed in buildings, and the EU has introduced legislation that aims to ensure that less energy is consumed in this way in the future.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

On Wednesday 11th May 2011 at 6:47 pm (local time) a magnitude 5.1 Mw earthquake occurred 6 km northeast of Lorca with a depth of around 2 km. As a consequence of the shallow depth and the small epicentral distance, important damage was produced in several masonry constructions and even led to the collapse of some of them. Pieces of the facades of several buildings fell down onto the sidewalk, being one of the reasons for the killing of a total of 9 people. The objective of this paper is to describe and analyze the failure patterns observed in unreinforced masonry buildings ranging from 3 to 8 floors in height. First, a brief description of the local building practices of masonry buildings is given. Then, the most important failure types of masonry buildings are described and discussed. After that, a more detailed analysis of one particular building is presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The application of conservation treatments, such as consolidation and protection ones, has been demonstrated ineffective in many cases, and even harmful. Evaluation studies should be a mandatory task, ideally before and after the intervention, but both tasks are complex and unusual in the case of archaeological heritage. This study is mainly focused on analyzing changes in petrophysical properties of stone material from archaeological sites of Merida (Spain), evaluating, both on site and in laboratory, effects derived from different conservation treatments applied in past interventions, throughout the integration of different non-destructive techniques (NDT) and portable devices of analysis available at the Institute of Geosciences (CSIC,UCM). These techniques allow, not only assessment of effectiveness and alteration processes, but also monitoring durability of treatments, focused mainly on 1996 intervention in the case of Roman Theater, as well as different punctual interventions from the 90?s until date in the House of Mitreo. Studies carried out on archaeological sites of Merida permit us to compare outcomes and also check limitations in the use of those equipments. In this paper we discuss about the use of some techniques, their integration and limits, for the assessment of conservation treatments, showing some examples of Merida?s case study.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

High suction loads appear on roofs of low-height buildings. The use of parapets with appropriate height at the roof edges alleviates these loads. The performance of six parapet configurations to decrease the suction loads induced on roofs by oblique winds has been studied in a low speed wind tunnel. The studied parapet configurations include vertical wall parapets, either solid or porous, and cantilevered parapets formed by a small horizontal roof close to the building roof. Low-height parapets with a medium porosity and cantilevered parapets are more efficient than solid parapets to reduce the wind suctions generated on the roofs by conical vortices.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Different methods to reduce the high suction caused by conical vortices have been reported in the literature: vertical parapets, either solid or porous, placed at the roof edges being the most analysed configuration. Another method for alleviating the high suction peaks due to conical vortices is the use of some non-standard parapet configuration like cantilever parapets. In this paper the influence of roof curvature on the conical vortex pattern appearing on a curved roof (Fig. 1) when subject to oblique winds is experimentally analysed by testing the mean pressure distribution on the curved roofs of low-rise building models in a wind tunnel. Also, the efficiency of cantilever parapets to reduce mean suction loads on curved roofs is experimentally checked. Very high suction loads have been measured on curved roofs, the magnitude of these high suction loads being significantly decreased when cantilever parapets are used. Thus, the suitability of these parapets to reduce wind pressure loads on curved roofs is demonstrated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Building-integrated Photovoltaics (BIPV) is one of the most promising technologies enabling buildings to generate on-site part of their electricity needs while performing architectural functionalities. A clear example of BIPV products consists of semi-transparent photovoltaic modules (STPV), designed to replace the conventional glazing solutions in building façades. Accordingly, the active building envelope is required to perform multiple requirements such as provide solar shading to avoid overheating, supply solar gains and thermal insulation to reduce heat loads and improve daylight utilization. To date, various studies into STPV systems have focused on their energy performance based on existing simulation programs, or on the modelling, normally validated by limited experimental data, of the STPV modules thermal behaviour. Taking into account that very limited experimental research has been conducted on the energy performance of STPV elements and that the characterization in real operation conditions is necessary to promote an energetically efficient integration of this technology in the building envelope, an outdoor testing facility has been designed, developed and built at the Solar Energy Institute of the Technical University of Madrid. In this work, the methodology used in the definition of the testing facility, its capability and limitations are presented and discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A complete characterisation of PV modules for building integration is needed in order to know their influence on the building’s global energy balance. Specifically, certain characteristic parameters should be obtained for each different PV module suitable for building integrated photovoltaics (BIPV), some by direct or indirect measurements at the laboratory, and others by monitoring the element performance mounted in real operating conditions. In the case of transparent building envelopes it is particularly important to perform an optical and thermal characterization of the PV modules that would be integrated in them. This paper addresses the optical characterization of some commercial thin-film PV modules having different degrees of transparency, suitable for building integration in façades. The approach is based on the measurement of the spectral UV/Vis/NIR reflectance and transmittance of the different considered samples, both at normal incidence and as a function of the angle of incidence. With the obtained results, the total and zoned UV, visible and NIR transmission and reflection values are calculated, enabling the correct characterization of the PV modules integrated in façades and the subsequent evaluation of their impact over the electrical, thermal and lighting performance in a building.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Modern design of civil constructions such as office blocks, airport terminal buildings, factories, etc. incorporates more and more environmental considerations that lead to, amongst other elements, the use of glazed façades with shading devices to optimize energy consumption. These shading devices, normally slats or louvers, are very flexible structures exposed to the action of wind, and therefore aeroelastic effects such as galloping must be taken into account in their design. A typical cross-section for such elements is a Z-shaped profile made out of a central web and two side wings. The results of a parametric analysis based on static wind tunnel tests and performed on different Z-shaped louvers to determine translational galloping instability regions are presented in this paper.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The city of Lorca (Spain) was hit on May 11th, 2011, by two consecutive earth-quakes of magnitudes 4.6 and 5.2 Mw, causing casualties and important damage in buildings. Many of the damaged structures were reinforced concrete frames with wide beams. This study quantifies the expected level of damage on this structural type in the case of the Lorca earth-quake by means of a seismic index Iv that compares the energy input by the earthquake with the energy absorption/dissipation capacity of the structure. The prototype frames investigated represent structures designed in two time periods (1994–2002 and 2003–2008), in which the applicable codes were different. The influence of the masonry infill walls and the proneness of the frames to concentrate damage in a given story were further investigated through nonlinear dynamic response analyses. It is found that (1) the seismic index method predicts levels of damage that range from moderate/severe to complete collapse; this prediction is consistent with the observed damage; (2) the presence of masonry infill walls makes the structure very prone to damage concentration and reduces the overall seismic capacity of the building; and (3) a proper hierarchy of strength between beams and columns that guarantees the formation of a strong column-weak beam mechanism (as prescribed by seismic codes), as well as the adoption of counter-measures to avoid the negative interaction between non-structural infill walls and the main frame, would have reduced the level of damage from Iv=1 (collapse) to about Iv=0.5 (moderate/severe damage)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The automation of domestic services began to be implemented in buildings since the late nineteenth century, and today we are used to terms like ‘intelligent buildings’, ‘digital home’ or ‘domotic buildings’. These concepts tell us about constructions which integrate new technologies in order to improve comfort, optimize energy consumption or enhance the security of users. In conjunction, building regulations have been updated to suit the needs of society and to regulate these new facilities in such structures. However, we are not always sure about how far, from the quantitative or qualitative point of view, legislation should regulate certain aspects of the building activity. Consequently, content analysis is adopted in this research to determine the influence of building regulations in the implementation of new technologies in the construction process. This study includes the analysis of different European regulations, the collection and documentation of such guidelines that have been established and a study of the impact that all of these have had in the way we start thinking an architectural project. The achievements of the research could be explained in terms of the regulatory requirements that must be taken into account in order to achieve a successful implementation of a home automation system, and the key finding has been the confirmation of how the design of smart buildings may be promoted through specific regulatory requirements while other factors, such as the global economic situation, do not seem to affect directly the rate of penetration of home automation in construction.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The building sector is well known to be one of the key energy consumers worldwide. The renovation of existing buildings provides excellent opportunities for an effective reduction of energy consumption and greenhouse gas emissions but it is essential to identify the optimal strategies. In this paper a multi-criteria methodology is proposed for the comparative analysis of retrofitting solutions. Life Cycle Assessment (LCA) and Life Cycle Cost (LCC) are combined by expressing environmental impacts in monetary values. A Pareto optimization is used to select the preferred strategies. The methodology is exemplified by a case study: the renovation of a representative housing block from the 1960s located in Madrid. Eight scenarios have been proposed, from the Business as Usual scenario (BAU), through Spanish Building Regulation requirements (for new buildings) up to the Passive House standard. Results show how current renovation strategies that are being applied in Madrid are far from being optimal solutions. The required additional investment, which is needed to obtain an overall performance improvement of the envelope compared with the common practice to date, is relatively low (8%) considering the obtained life cycle environmental and financial savings (43% and 45%, respectively).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

https://bluetigercommons.lincolnu.edu/postcards/1005/thumbnail.jpg

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The project and the works described in this article mainly deal with the removal of the current asbestos-cement covering of the roof of the Central Market in Alicante and its replacement with zinc diamond-shaped scales, similar to the originals which were implemented in 1921 when the building was put into service. These upgrades were necessary to avoid the causes (and consequences) of rainwater infiltration, as described in an earlier report in 2006, also drafted by the author of this article. The article illustrates the difficulties involving the practical application of Spanish Code RD 396/2006 (minimum safety and health requirements for work with risk of exposure to asbestos) in a complex case such as this, especially with regard to aspects such as economic (increasing costs), technical (increased difficulty of implementation), and the total duration of the work (total increase in duration due to interference with other trades).