Performance of masonry buildings during the 2011 Lorca earthquake


Autoria(s): Hermanns, Lutz Karl Heinz; Fraile de Lerma, Alberto; Alarcón Álvarez, Enrique; Álvarez Cabal, Ramón
Data(s)

2012

Resumo

On Wednesday 11th May 2011 at 6:47 pm (local time) a magnitude 5.1 Mw earthquake occurred 6 km northeast of Lorca with a depth of around 2 km. As a consequence of the shallow depth and the small epicentral distance, important damage was produced in several masonry constructions and even led to the collapse of some of them. Pieces of the facades of several buildings fell down onto the sidewalk, being one of the reasons for the killing of a total of 9 people. The objective of this paper is to describe and analyze the failure patterns observed in unreinforced masonry buildings ranging from 3 to 8 floors in height. First, a brief description of the local building practices of masonry buildings is given. Then, the most important failure types of masonry buildings are described and discussed. After that, a more detailed analysis of one particular building is presented.

Formato

application/pdf

Identificador

http://oa.upm.es/26063/

Idioma(s)

eng

Publicador

E.T.S.I. Industriales (UPM)

Relação

http://oa.upm.es/26063/1/Performance_Lorca.pdf

http://www.coming.pt/15wcee/general.html

Direitos

http://creativecommons.org/licenses/by-nc-nd/3.0/es/

info:eu-repo/semantics/openAccess

Fonte

15 World Conference on Earthquake Engineering | 15th. World Conference on Earthquake Engineering | 24/09/2012-28/09/2012 | Lisboa

Palavras-Chave #Ingeniería Civil y de la Construcción
Tipo

info:eu-repo/semantics/conferenceObject

Ponencia en Congreso o Jornada

NonPeerReviewed