922 resultados para Diameter of Graph
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Capillary electrophoresis has become a well-established and routine-based separation technique. It is based on the differences between charged analyte mobility in aqueous or organic electrolytes. Its major limitation is the sensitivity due to small sample injection volumes and the narrow diameter of the capillaries, especially when UV detection is used. There are a number of ways to increase the concentration sensitivity. This report shows some on-line preconcentration strategies to perform it in free solution capillary electrophoresis that are based on manipulation of the analyte electrophoretic velocity during the sample introduction (stacking, field amplification and transient isotachophoresis).
Resumo:
Caracteres genéricos são ampliados para Irundisaua Martins & Galileo, 2005 (configuração das antenas; processo prosternal com largura menor ou igual à largura de uma procoxa; protíbias achatadas e fortemente alargadas para o ápice) ao qual se adicionam espécies transferidas de Acanthoderes Audinet-Serville, 1835: I. forsteri (Tippmann, 1960) comb. nov. do Peru e Brasil (Amazonas) e I. ucayalensis (Tippmann, 1960) comb. nov. do Equador, Peru e Brasil (Amazonas).Três novos gêneros são descritos: (1) Catuana comb. nov., espécie-tipo, C. thoracica (Tippmann, 1960) comb. nov., caracterizado pelo mesosterno com tubérculo; (2) Mundeu comb. nov., espécie-tipo, M. maculicollis (Bates, 1861) comb. nov., com protórax arredondado nos lados e protíbias alargadas; (3) Urangaua comb. nov., caracteriza-se pelos olhos finamente facetados e divididos, comprimento dos antenômeros III e IV subigual ao comprimento dos antenômeros V-XI em conjunto; é proposto para duas espécies: U. analis Melzer, 1935, comb. nov., espécietipo, e U. subanalis (Zajciw, 1964) comb. nov. Adiciona-se chave para as espécies de Urangaua.
Resumo:
O objetivo deste trabalho foi de analisar morfometricamente fragmentos histológicos do baço de animais normais e diabéticos, comparando os resultados encontrados e relacionando-os ao sexo e a suplementação da vitamina C. Foram utilizados 32 ratos Wistar, os quais foram analisados número de vasos, o número de folículos germinativos (polpa branca) e o diâmetro dos vasos de cada animal. As análises histológicas e morfometricas foram feitas em amostras de 5µm de espessura demonstrando que: na quantidade de folículos germinativos, observamos resultados comparando, independente do sexo, animais controles suplementados com vitamina C e controles não suplementados (p≤0,05; F=0,1452); na quantidade de vasos, observamos resultados comparando, fêmeas diabéticas suplementadas pela vitamina C e fêmeas diabéticas não suplementadas (pd"0,05; F=6.8893); e no diâmetro dos vasos, observamos resultados comparando fêmeas, tanto no grupo controle quanto ao grupo diabético, suplementadas pela vitamina C quando comparadas às fêmeas não suplementadas pela vitamina C (p<0,05; U=121.50; Z(U)=2.1234) e (p<0,05; F=4.8134). De um modo geral, a indução de diabetess modifica o diâmetro vascular nas fêmeas e que a administração de vitamina C interfere nos dados métricos relativos ao diâmetro vascular somente nas fêmeas.
Resumo:
In the crystal of the title compound, C(17)H(16)N(2), molecules are linked by C-H center dot center dot center dot N hydrogen bonds, forming rings of graph-set motifs R(2)(1) (6) and R(2)(2) (10). The title molecule is close to planar, with a dihedral angle between the aromatic rings of 0.6 (1)degrees. Torsion angles confirm a conformational trans structure.
Resumo:
In the title compound, C10H6ClNO2, the dihedral angle between the benzene and maleimide rings is 47.54 (9)degrees. Molecules form centrosymmetric dimers through C-H center dot center dot center dot O hydrogen bonds, resulting in rings of graph- set motif R2 2(8) and chains in the [100] direction. Molecules are also linked by C-H center dot center dot center dot Cl hydrogen bonds along [001]. In this same direction, molecules are connected to other neighbouring molecules by C-H center dot center dot center dot O hydrogen bonds, forming edge- fused R-4(4)(24) rings.
Resumo:
This paper presents the characterization of poly(aniline) (PANI) and poly(methyl methacrylate) (PMMA) coatings obtained by mixing PANI with PMMA aqueous dispersions (latex particles). These dispersions were characterized by using dynamic light scattering for sizing, zeta-potential analysis and thermal analysis. PMMA and PANI/PMMA dispersions show negative charged particles with zeta potential greater than |40| mV, a zeta-average diameter of 64 nm for pure PMMA and a bi-modal particle-size distribution centered at 45 and 120 nm for a mixture with 25% w/w of PANI. Films obtained by casting were characterized by using scanning electron microscopy and they show a conductivity increase upon PANI content reaching a value of 1 mS cm(-1) for a film with 25% w/w of PANI. In addition, Raman spectroscopy have shown the presence of the conducting form of PANI in the films and cyclic voltammetry experiments corroborated that they are electroactive in both acid and neutral solutions.
Resumo:
Duplex and superduplex stainless steels present superior mechanical and corrosion properties when compared to usual stainless steels. This superiority is based on chemical composition when in a balanced microstructure (approximately 50% of ferrite). During welding, changes may occur in both, the chemical composition and volume fraction of phases in the material, which may generate the presence of intermetallic phases and, as a consequence, modify the mechanical and corrosion properties of this group of stainless steels. The objective of this work is to apply ASTM A923- Practice A to verify the presence of intermetallic phases in welded joints of UNS 32750 su-perduplex stainless steel. Tubes of UNS 32750, with external diameters of 18 and 44 mm and a thickness of 1.5 mm, were welded using orbital GTAW, with filler metal 25Cr-10Ni-4Mo and a diameter of 0.8 mm. The metal-based and welded joints were characterized by optical and scanning electron microscopy. The results showed that there was no precipitation of the intermetallic phase, such as sigma phase, detected by ASTM A923, but the HAZ of the two tubes studied presented small regions with chromium nitrides, which can also change the properties of welded joins.
Resumo:
A modified cyclone washer was designed, fabricated, and its collection efficiency evaluated. This equipment consists of an American-type cyclone separator with a triple cone and a spray nozzle was introduced into its cylindrical body. The study consisted of an experimental evaluation of the operating conditions at ambient and higher than ambient temperatures, varying chimney height and water flow rate, with the purpose of humidifying the dust. The collection efficiency of the cyclone washer was evaluated particles of micronized quartz with an average diameter of 7.48 mu m and a density of 2.650 g/cm(3). The amount of particles varied from 20-100 mg/m(3) of air. An average efficiency of 97.07 +/- 1.03 % was obtained with four spray nozzles, a chimney height of 0.645 m and 0.358 m(3)/s of gas.
Resumo:
Monoclonal antibodies (MAb) have been commonly applied to measure LDL in vivo and to characterize modifications of the lipids and apoprotein of the LDL particles. The electronegative low density lipoprotein (LDL(-)) has an apolipoprotein B-100 modified at oxidized events in vivo. In this work, a novel LDL-electrochemical biosensor was developed by adsorption of anti-LDL(-) MAb on an (polyvinyl formal)-gold nanoparticles (PVF-AuNPs)-modified gold electrode. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used to characterize the recognition of LDL-. The interaction between MAb-LDL(-) leads to a blockage in the electron transfer of the [Fe(CN)(6)](4-)/K(4)[Fe(CN)(6)](3-) redox couple, which may could result in high change in the electron transfer resistance (R(CT)) and decrease in the amperometric responses in CV analysis. The compact antibody-antigen complex introduces the insulating layer on the assembled surface, which increases the diameter of the semicircle, resulting in a high R(CT), and the charge transferring rate constant k(0) decreases from 18.2 x 10(-6) m/s to 4.6 x 10(-6) m/s. Our results suggest that the interaction between MAb and lipoprotein can be quantitatively assessed by the modified electrode. The PVF-AuNPs-MAb system exhibited a sensitive response to LDL(-), which could be used as a biosensor to quantify plasmatic levels of LDL(-). (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The (-)-hinokinin display high activity against Trypanosoma cruzi in vitro and in vivo. (-)-Hinokinin-loaded poly(d,l-lactide-co-glycolide) microparticles were prepared and characterized in order to protect (-)-hinokinin of biological interactions and promote its sustained release for treatment of Chagas disease. The microparticles contain (-)-hinokinin were prepared by the classical method of the emulsion/solvent evaporation. The scanning electron microscopy, light-scattering analyzer were used to study the morphology and particle size, respectively. The encapsulation efficiency was determined, drug release studies were kinetically evaluated, and the trypanocidal effect was evaluated in vivo. (-)-Hinokinin-loaded microparticles obtained showed a mean diameter of 0.862 A mu m with smooth surface and spherical shape. The encapsulation efficiency was 72.46 A +/- 2.92% and developed system maintained drug release with Higuchi kinetics. The preparation method showed to be suitable, since the morphological characteristics, encapsulation efficiency, and in vitro release profile were satisfactory. In vivo assays showed significant reduction of mice parasitaemia after administration of (-)-hinokinin-loaded microparticles. Thus, the developed microparticles seem to be a promising system for sustained release of (-)-hinokinin for treatment of Chagas disease.
Resumo:
Copper concentrate (chalcopyrite) was granulated in a rotating drum with a diameter of 0.3 m and a length of 0.2 m. Water was used as the binder and it was sprayed onto the powder bed with a nozzle. This material exhibited induction type behaviour, which was defined by Iveson and Litster [AIChE J. 44 (1998) 1510]. Induction type behaviour is characterized by the occurrence of an induction stage, during which the granules are gradually being compacted and little or no growth occurs. At the end of this induction stage, binder liquid is squeezed from the interior of the granules onto the granule surface and the granules are then surface-wet. This results in a rapid growth rate of the granules. Different types of experiments were conducted. The influence of the nozzle pressure and the distance from the nozzle to the powder bed on the growth behaviour of the granules as well as on the binder distribution was examined. The results of these experiments led to the postulation of a modified mechanism for induction type behaviour: it was found that after the binder was delivered, there were large granules containing a high amount of binder and small granules containing less binder. During the induction stage, the granules are compacted and binder liquid continuously appears at the surface of the large granules. These wet spots that are continuously being formed pick up the dry and small granules. When all the small granules have been picked up, further expulsion of binder liquid onto the granules' surface results in granules that remain surface-wet. This phenomenon marks the end of the induction stage and it coincides with the disappearance of the small granules. The hypothesis was tested by selectively removing the smaller granules during an experiment. As expected, this resulted in a shorter induction time.
Resumo:
Objectives-To investigate the feasibility of selective screening for abdominal aortic aneurysm (AAA) based on identification of a target group of manageable size defined by risk factors for AAA. Setting-Male residents of Perth, Western Australia, aged 65-83 years, who participated in a randomised controlled trial of ultrasound screening for AAA. Methods-Eligible men were identified from the electoral roll and invited to attend a screening clinic. Those who attended completed a questionnaire, had a limited physical examination, and underwent an ultrasound examination to identify the maximum diameter of the infrarenal aorta. Data on risk factors collected from the first 8995 men seen were used to calculate a multivariate risk score for the remaining 2755 men who were screened. Gentiles of the risk score were used to define potential target groups for screening and the sensitivity and specificity of each of these selective screening strategies were calculated. We repeated the calculation separately for AAAs of at least 30 mm, 40 mm, and 50 mm in diameter. Results-We found that screening half of the male population aged 65-83 years would find approximately 75% of AAAs, regardless of their size, whereas screening only current smokers in this population would find approximately 20% of AAAs. Conclusions-Selective screening for AAA using easily recognisable risk factors is feasible but is not worthwhile as approximately 25% of clinically significant cases would be missed.
Resumo:
In the present work, various theories predicting the critical diameter for the absence of capillary condensation and hysteresis are applied to experimental adsorption isotherms of vapors on regular mesoporous materials. Among the various theories studied, the tensile strength approximation proposed by the authors was found to be the most successful. Reversibility of nitrogen adsorption at 77.4 K was studied on pure MCM-41 of various pore sizes, as well as mixtures of pure MCM-41 samples in a 1:1 ratio. The results of PSD and hysteresis on MCM-41 mixtures are close to that expected from studies of the pure materials. The estimates of hysteresis critical temperature and diameter of MCM-41, HMS, FSM and KIT materials are also provided.
Resumo:
BACKGROUND: Retention of airway secretions is a common and serious problem in ventilated patients. Treating or avoiding secretion retention with mucus thinning, patient-positioning, airway suctioning, or chest or airway vibration or percussion may provide short-term benefit. METHODS: In a series of laboratory experiments with a test-lung system we examined the role of ventilator settings and lung-impedance on secretion retention and expulsion. Known quantities of a synthetic dye-stained mucus simulant with clinically relevant properties were injected into a transparent tube the diameter of an adult trachea and exposed to various mechanical-ventilation conditions. Mucus-simulant movement was measured with a photodensitometric technique and examined with image-analysis software. We tested 2 mucus-simulant viscosities and various peak flows, inspiratory/ expiratory flow ratios, intrinsic positive end-expiratory pressures, ventilation waveforms, and impedance values. RESULTS: Ventilator settings that produced flow bias had a major effect on mucus movement. Expiratory How bias associated with intrinsic positive end-expiratory pressure generated by elevated minute ventilation moved mucus toward the airway opening, whereas intrinsic positive end-expiratory pressure generated by increased airway resistance moved the mucus toward the lungs. Inter-lung transfer of mucus simulant occurred rapidly across the ""carinal divider"" between interconnected test lungs set to radically different compliances; the mucus moved out of the low-compliance lung and into the high-compliance lung. CONCLUSIONS: The movement of mucus simulant was influenced by the ventilation pattern and lung impedance. Flow bias obtained with ventilator settings may clear or embed mucus during mechanical ventilation.