993 resultados para DOSE NUMBER
Resumo:
To investigate the influence of the number of queens per colony on nestmate recognition in Iridomyrmex humilis, comparative assays were performed to study the attraction of workers to queens. These assays demonstrated that a phenomenon of recognition is superimposed on the attraction of workers to queens. Workers could discriminate non-nestmate queens from their nestmate queen to which they were significantly more attracted. This discrimination is probably based on the learning by workers of queen and colony odour. The level of attraction of workers to non-nestmate queens was similar in monogynous and polygynous colonies, whereas the level of attraction of workers to nestmate queens was significantly lower in polygynous colonies. This difference in the level of attraction of workers to nestmate queens almost certainly resulted from a lower efficiency in nestmate recognition in polygynous colonies. It is hypothesized that the mixture of several pheromonal sources produced by less related individuals in polygynous colonies may result in a less distinct colony odour than in monogynous colonies. The results are discussed with regard to some implications of polygyny and particularly to the loss of intercolonial aggression in I. humilis as well as in other polygynous ant species
Resumo:
Imatinib (Glivec®) has transformed the treatment and short-term prognosis of chronic myeloid leukaemia (CML) and gastro-intestinal stromal tumour (GIST). However, the treatment must be taken indefinitely, it is not devoid of inconvenience and toxicity. Moreover, resistance or escape from disease control occur in a significant number of patients. Imatinib is a substrate of the cytochromes P450 CYP3A4/5 and of the multidrug transporter P glycoprotein (product of the MDR1 gene). Considering the large inter-individual differences in the expression and function of those systems, the disposition and clinical activity of imatinib can be expected to vary widely among patients, calling for dosage individualisation. The aim of this exploratory study was to determine the average pharmacokinetic parameters characterizing the disposition of imatinib in the target population, to assess their inter-individual variability, and to identify influential factors affecting them. A total of 321 plasma concentrations, taken at various sampling times after latest dose, were measured in 59 patients receiving Glivec® at diverse regimens, using a validated chromatographic method (HPLC-UV) developed for this study. The results were analysed by non-linear mixed effect modelling (NONMEM). A one- compartment model with first-order absorption appeared appropriate to describe the data, with an average apparent clearance of 12.4 l/h, a distribution volume of 268 l and an absorption constant of 0.47 h-1. The clearance was affected by body weight, age and sex. No influences of interacting drugs were found. DNA samples were used for pharmacogenetic explorations. The MDR1 polymorphism 3435C>T appears to affect the disposition of imatinib. Large inter-individual variability remained unexplained by the demographic covariates considered, both on clearance (40%) and distribution volume (71%). Together with intra-patient variability (34%), this translates into an 8-fold width of the 90%-prediction interval of plasma concentrations expected under a fixed dosing regimen ! This is a strong argument to further investigate the possible usefulness of a therapeutic drug monitoring programme for imatinib. It may help to individualise the dosing regimen before overt disease progression or observation of treatment toxicity, thus improving both the long-term therapeutic effectiveness and tolerability of this drug.
Resumo:
Nanoparticles <100 nanometres are being introduced into industrial processes, but they are suspected to cause similar negative health effects to ambient particles. Poor knowledge about the scale of introduction has not allowed global risk analysis until now. In 2006 a targeted telephone survey among Swiss companies (1) showed the usage of nanoparticles in a few selected companies but did not provide data to extrapolate to the full Swiss workforce. The purpose of the study presented here was to provide a quantitative estimate of the potential occupational exposure to nanoparticles in Swiss industry. Method: A layered representative questionnaire survey among 1626 Swiss companies of the production sector was conducted in 2007. The survey was a written questionnaire, collecting data about the used nanoparticles, the number of potentially exposed persons in the companies and their protection strategy. Results: The response rate of the study was 58.3%. The number of companies estimated to be using nanoparticles in Switzerland was 586 (95% Confidence Interval 145 to 1027). It is estimated that 1309 workers (95% CI 1073 to 1545) do their job in the same room as a nanoparticle application. Personal protection was shown to be the predominant protection means. Such information is valuable for risk evaluation. The low number of companies dealing with nanoparticles in Switzerland suggests that policy makers as well as health, safety and environmental officers within companies can focus their efforts on a relatively small number of companies or workers. The collected data about types of particles and applications may be used for research on prevention strategies and adapted protection means. However, to reflect the most recent trends, the information presented here has to be continuously updated, and a large-scale inventory of the usage should be considered.
Resumo:
Poor compliance with antihypertensive drug regimens is one recognized cause of inadequate blood pressure control. Compliance is difficult to measure, so poor adherence to treatment remains largely undiagnosed in clinical practice. When the therapeutic response to a drug is not the one expected, it is a major challenge for many physicians to decide whether the patient is a non-responder or a non-complier. Poor compliance is therefore often incorrectly interpreted as a lack of response to treatment. Not detecting non-compliance can lead to the wrong measures being taken. Electronic monitoring of compliance provides important longitudinal information about drug-intake behaviour that cannot be obtained in the clinic. Such monitoring can improve both compliance and blood pressure control, and help physicians to make more rational therapeutic decisions. A reliable assessment of compliance could have a great impact on medical costs by preventing unnecessary investigations or dose adaptations in patients who are not taking their drugs adequately, or potentially reducing the number of hospitalizations. Side-effects and lack of effectiveness are two frequent causes of poor compliance. The right choice of antihypertensive drug can therefore contribute to compliance. In this respect, it is important to find a drug regimen that is effective, long-acting and well tolerated. Long-acting antihypertensive drugs that provide good blood pressure control beyond the 24-h dosing period should perhaps be considered as drugs of choice in non-compliant patients with hypertension because they help to prevent the consequences of occasional drug omissions.
Resumo:
Background: Prognostic and predictive markers are of great importance for future study designs and essential for the interpretation of clinical trials incorporating an EGFR-inhibitor. The current study prospectively assessed and validated KRAS, BRAF and PIK3CA mutations in rectal cancer patients screened for the trial SAKK41/07 of concomitant preoperative radio-chemotherapy with or without panitumumab.Methods: Macrodissection was performed on pretreatment formalin fixed paraffin embedded biopsy tissue sections to arrive at a minimum of 50% of tumor cells. DNA was extracted with the Maxwell 16 FFPE Tissue LEV DNA purification kit. After PCR amplification, mutations were identified by pyrosequencing. We prospectively analysed pretreatment biopsy material from 149 rectal cancer pts biopsies for KRAS (exon 2 codon 12 [2-12] and 13 [2-13], exon 3 codon 59 [3-59]) and 61 [3-61], exon 4 codon 117 [4-117] and 146 [4-146]). Sixty-eight pts (KRASwt exon 2, 3 only) were further analysed for BRAF (exon 15 codon 600) and PIK3CA (exon 9 codon 542, 545 and 546, exon 20 codon 1043 [20-1043] and 1047 [20-1047]) mutations, and EGFR copy number by qPCR. For the calculation of the EGFR copy number, we used KRAS copy number as internal reference standard. The calculation was done on the basis of the two standard curves relative quantification method.Results: In 149 screened pts with rectal cancer, the prevalence of KRAS mutations was 36%. Among the 68 pts enrolled in SAKK 41/07 based on initially presumed KRASwt status (exon 2/codons 12+13), 18 pts (26%) had a total of 23 mutations in the RAS/PIK3CA-pathways upon validation analysis. Twelve pts had a KRAS mutation, 7 pts had a PIK3CA mutation, 3 pts had a NRAS mutation, 1 patient a BRAF mutation. Surprisingly, five of these pts had double- mutations, including 4 pts with KRAS plus PIK3CA mutations, and 1 pt with NRAS plus PIK3CA mutations. The median normalized EGFR copy number was 1. Neither mutations of KRAS, BRAF, and PIK3CA, nor EGFR copy number were statistically associated with the primary study endpoint pCR (pathological complete regression).Conclusions: The prevalence of KRAS mutations in rectal and in colon cancer appears to be similar. BRAF mutations are rare; PIK3CA mutations are more common (10%). EGFR copy number is not increased in rectal cancer. A considerable number or KRAS exon 2 wt tumors harbored KRAS exon 3+4 mutations. Further study is needed to determine if KRAS testing should include exons 2-4.
Resumo:
Endocarditis prophylaxis following genitourinary or gastrointestinal procedures targets Enterococcus faecalis. Prophylaxis recommendations advocate oral amoxicillin (2 g in the United States and 3 g in the United Kingdom) in moderate-risk patients and intravenous amoxicillin (2 g) or vancomycin (1 g) plus gentamicin in high-risk patients. While ampicillin-resistant (or amoxicillin-resistant) E. faecalis is still rare, there is a concern that these regimens might fail against vancomycin-resistant and/or aminoglycoside-resistant isolates. The present study tested oral linezolid as an alternative. Rats with catheter-induced aortic vegetations were given prophylaxis simulating human pharmacokinetics of oral amoxicillin (2- to 3-g single dose), oral linezolid (600 mg, single or multiple oral doses every 12 h), or intravenous vancomycin (1-g single dose). Rats were then inoculated with the minimum inoculum infecting 90% of the animals (90% infective dose [ID(90)]) or with 10 times the ID(90) of the vancomycin-susceptible E. faecalis strain JH2-2 or the vancomycin-resistant (VanA phenotype) E. faecalis strain UCN41. Amoxicillin was also tested with two additional vancomycin-susceptible E. faecalis strains, 309 and 1209. Animals were sacrificed 3 days later. All the tested bacteria were susceptible to amoxicillin and gentamicin. Single-dose amoxicillin provided 100% protection against all four isolates at both the ID(90) and 10 times the ID(90). In contrast, linezolid required up to four consecutive doses to provide full protection against the vancomycin-resistant isolate. Vancomycin protected only against the vancomycin-susceptible strain. The high efficacy of single-dose oral amoxicillin suggests that this regimen could be used for prophylaxis in both moderate-risk and high-risk patients without additional aminoglycosides. Linezolid appears to be less reliable, at least against the vancomycin-resistant strain.
Resumo:
In vivo dosimetry is a way to verify the radiation dose delivered to the patient in measuring the dose generally during the first fraction of the treatment. It is the only dose delivery control based on a measurement performed during the treatment. In today's radiotherapy practice, the dose delivered to the patient is planned using 3D dose calculation algorithms and volumetric images representing the patient. Due to the high accuracy and precision necessary in radiation treatments, national and international organisations like ICRU and AAPM recommend the use of in vivo dosimetry. It is also mandatory in some countries like France. Various in vivo dosimetry methods have been developed during the past years. These methods are point-, line-, plane- or 3D dose controls. A 3D in vivo dosimetry provides the most information about the dose delivered to the patient, with respect to ID and 2D methods. However, to our knowledge, it is generally not routinely applied to patient treatments yet. The aim of this PhD thesis was to determine whether it is possible to reconstruct the 3D delivered dose using transmitted beam measurements in the context of narrow beams. An iterative dose reconstruction method has been described and implemented. The iterative algorithm includes a simple 3D dose calculation algorithm based on the convolution/superposition principle. The methodology was applied to narrow beams produced by a conventional 6 MV linac. The transmitted dose was measured using an array of ion chambers, as to simulate the linear nature of a tomotherapy detector. We showed that the iterative algorithm converges quickly and reconstructs the dose within a good agreement (at least 3% / 3 mm locally), which is inside the 5% recommended by the ICRU. Moreover it was demonstrated on phantom measurements that the proposed method allows us detecting some set-up errors and interfraction geometry modifications. We also have discussed the limitations of the 3D dose reconstruction for dose delivery error detection. Afterwards, stability tests of the tomotherapy MVCT built-in onboard detector was performed in order to evaluate if such a detector is suitable for 3D in-vivo dosimetry. The detector showed stability on short and long terms comparable to other imaging devices as the EPIDs, also used for in vivo dosimetry. Subsequently, a methodology for the dose reconstruction using the tomotherapy MVCT detector is proposed in the context of static irradiations. This manuscript is composed of two articles and a script providing further information related to this work. In the latter, the first chapter introduces the state-of-the-art of in vivo dosimetry and adaptive radiotherapy, and explains why we are interested in performing 3D dose reconstructions. In chapter 2 a dose calculation algorithm implemented for this work is reviewed with a detailed description of the physical parameters needed for calculating 3D absorbed dose distributions. The tomotherapy MVCT detector used for transit measurements and its characteristics are described in chapter 3. Chapter 4 contains a first article entitled '3D dose reconstruction for narrow beams using ion chamber array measurements', which describes the dose reconstruction method and presents tests of the methodology on phantoms irradiated with 6 MV narrow photon beams. Chapter 5 contains a second article 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations. A dose reconstruction process specific to the use of the tomotherapy MVCT detector is presented in chapter 6. A discussion and perspectives of the PhD thesis are presented in chapter 7, followed by a conclusion in chapter 8. The tomotherapy treatment device is described in appendix 1 and an overview of 3D conformai- and intensity modulated radiotherapy is presented in appendix 2. - La dosimétrie in vivo est une technique utilisée pour vérifier la dose délivrée au patient en faisant une mesure, généralement pendant la première séance du traitement. Il s'agit de la seule technique de contrôle de la dose délivrée basée sur une mesure réalisée durant l'irradiation du patient. La dose au patient est calculée au moyen d'algorithmes 3D utilisant des images volumétriques du patient. En raison de la haute précision nécessaire lors des traitements de radiothérapie, des organismes nationaux et internationaux tels que l'ICRU et l'AAPM recommandent l'utilisation de la dosimétrie in vivo, qui est devenue obligatoire dans certains pays dont la France. Diverses méthodes de dosimétrie in vivo existent. Elles peuvent être classées en dosimétrie ponctuelle, planaire ou tridimensionnelle. La dosimétrie 3D est celle qui fournit le plus d'information sur la dose délivrée. Cependant, à notre connaissance, elle n'est généralement pas appliquée dans la routine clinique. Le but de cette recherche était de déterminer s'il est possible de reconstruire la dose 3D délivrée en se basant sur des mesures de la dose transmise, dans le contexte des faisceaux étroits. Une méthode itérative de reconstruction de la dose a été décrite et implémentée. L'algorithme itératif contient un algorithme simple basé sur le principe de convolution/superposition pour le calcul de la dose. La dose transmise a été mesurée à l'aide d'une série de chambres à ionisations alignées afin de simuler la nature linéaire du détecteur de la tomothérapie. Nous avons montré que l'algorithme itératif converge rapidement et qu'il permet de reconstruire la dose délivrée avec une bonne précision (au moins 3 % localement / 3 mm). De plus, nous avons démontré que cette méthode permet de détecter certaines erreurs de positionnement du patient, ainsi que des modifications géométriques qui peuvent subvenir entre les séances de traitement. Nous avons discuté les limites de cette méthode pour la détection de certaines erreurs d'irradiation. Par la suite, des tests de stabilité du détecteur MVCT intégré à la tomothérapie ont été effectués, dans le but de déterminer si ce dernier peut être utilisé pour la dosimétrie in vivo. Ce détecteur a démontré une stabilité à court et à long terme comparable à d'autres détecteurs tels que les EPIDs également utilisés pour l'imagerie et la dosimétrie in vivo. Pour finir, une adaptation de la méthode de reconstruction de la dose a été proposée afin de pouvoir l'implémenter sur une installation de tomothérapie. Ce manuscrit est composé de deux articles et d'un script contenant des informations supplémentaires sur ce travail. Dans ce dernier, le premier chapitre introduit l'état de l'art de la dosimétrie in vivo et de la radiothérapie adaptative, et explique pourquoi nous nous intéressons à la reconstruction 3D de la dose délivrée. Dans le chapitre 2, l'algorithme 3D de calcul de dose implémenté pour ce travail est décrit, ainsi que les paramètres physiques principaux nécessaires pour le calcul de dose. Les caractéristiques du détecteur MVCT de la tomothérapie utilisé pour les mesures de transit sont décrites dans le chapitre 3. Le chapitre 4 contient un premier article intitulé '3D dose reconstruction for narrow beams using ion chamber array measurements', qui décrit la méthode de reconstruction et présente des tests de la méthodologie sur des fantômes irradiés avec des faisceaux étroits. Le chapitre 5 contient un second article intitulé 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations'. Un procédé de reconstruction de la dose spécifique pour l'utilisation du détecteur MVCT de la tomothérapie est présenté au chapitre 6. Une discussion et les perspectives de la thèse de doctorat sont présentées au chapitre 7, suivies par une conclusion au chapitre 8. Le concept de la tomothérapie est exposé dans l'annexe 1. Pour finir, la radiothérapie «informationnelle 3D et la radiothérapie par modulation d'intensité sont présentées dans l'annexe 2.
Resumo:
Size and copy number of organelles are influenced by an equilibrium of membrane fusion and fission. We studied this equilibrium on vacuoles-the lysosomes of yeast. Vacuole fusion can readily be reconstituted and quantified in vitro, but it had not been possible to study fission of the organelle in a similar way. Here we present a cell-free system that reconstitutes fragmentation of purified yeast vacuoles (lysosomes) into smaller vesicles. Fragmentation in vitro reproduces physiological aspects. It requires the dynamin-like GTPase Vps1p, V-ATPase pump activity, cytosolic proteins, and ATP and GTP hydrolysis. We used the in vitro system to show that the vacuole-associated TOR complex 1 (TORC1) stimulates vacuole fragmentation but not the opposing reaction of vacuole fusion. Under nutrient restriction, TORC1 is inactivated, and the continuing fusion activity then dominates the fusion/fission equilibrium, decreasing the copy number and increasing the volume of the vacuolar compartment. This result can explain why nutrient restriction not only induces autophagy and a massive buildup of vacuolar/lysosomal hydrolases, but also leads to a concomitant increase in volume of the vacuolar compartment by coalescence of the organelles into a single large compartment.
Resumo:
Cancer genomes frequently contain somatic copy number alterations (SCNA) that can significantly perturb the expression level of affected genes and thus disrupt pathways controlling normal growth. In melanoma, many studies have focussed on the copy number and gene expression levels of the BRAF, PTEN and MITF genes, but little has been done to identify new genes using these parameters at the genome-wide scale. Using karyotyping, SNP and CGH arrays, and RNA-seq, we have identified SCNA affecting gene expression ('SCNA-genes') in seven human metastatic melanoma cell lines. We showed that the combination of these techniques is useful to identify candidate genes potentially involved in tumorigenesis. Since few of these alterations were recurrent across our samples, we used a protein network-guided approach to determine whether any pathways were enriched in SCNA-genes in one or more samples. From this unbiased genome-wide analysis, we identified 28 significantly enriched pathway modules. Comparison with two large, independent melanoma SCNA datasets showed less than 10% overlap at the individual gene level, but network-guided analysis revealed 66% shared pathways, including all but three of the pathways identified in our data. Frequently altered pathways included WNT, cadherin signalling, angiogenesis and melanogenesis. Additionally, our results emphasize the potential of the EPHA3 and FRS2 gene products, involved in angiogenesis and migration, as possible therapeutic targets in melanoma. Our study demonstrates the utility of network-guided approaches, for both large and small datasets, to identify pathways recurrently perturbed in cancer.
Resumo:
This report presents systematic empirical annotation of transcript products from 399 annotated protein-coding loci across the 1% of the human genome targeted by the Encyclopedia of DNA elements (ENCODE) pilot project using a combination of 5' rapid amplification of cDNA ends (RACE) and high-density resolution tiling arrays. We identified previously unannotated and often tissue- or cell-line-specific transcribed fragments (RACEfrags), both 5' distal to the annotated 5' terminus and internal to the annotated gene bounds for the vast majority (81.5%) of the tested genes. Half of the distal RACEfrags span large segments of genomic sequences away from the main portion of the coding transcript and often overlap with the upstream-annotated gene(s). Notably, at least 20% of the resultant novel transcripts have changes in their open reading frames (ORFs), most of them fusing ORFs of adjacent transcripts. A significant fraction of distal RACEfrags show expression levels comparable to those of known exons of the same locus, suggesting that they are not part of very minority splice forms. These results have significant implications concerning (1) our current understanding of the architecture of protein-coding genes; (2) our views on locations of regulatory regions in the genome; and (3) the interpretation of sequence polymorphisms mapping to regions hitherto considered to be "noncoding," ultimately relating to the identification of disease-related sequence alterations.
Resumo:
BACKGROUND: The dose intensity of chemotherapy can be increased to the highest possible level by early administration of multiple and sequential high-dose cycles supported by transfusion with peripheral blood progenitor cells (PBPCs). A randomized trial was performed to test the impact of such dose intensification on the long-term survival of patients with small cell lung cancer (SCLC). METHODS: Patients who had limited or extensive SCLC with no more than two metastatic sites were randomly assigned to high-dose (High, n = 69) or standard-dose (Std, n = 71) chemotherapy with ifosfamide, carboplatin, and etoposide (ICE). High-ICE cycles were supported by transfusion with PBPCs that were collected after two cycles of treatment with epidoxorubicin at 150 mg/m(2), paclitaxel at 175 mg/m(2), and filgrastim. The primary outcome was 3-year survival. Comparisons between response rates and toxic effects within subgroups (limited or extensive disease, liver metastases or no liver metastases, Eastern Cooperative Oncology Group performance status of 0 or 1, normal or abnormal lactate dehydrogenase levels) were also performed. RESULTS: Median relative dose intensity in the High-ICE arm was 293% (range = 174%-392%) of that in the Std-ICE arm. The 3-year survival rates were 18% (95% confidence interval [CI] = 10% to 29%) and 19% (95% CI = 11% to 30%) in the High-ICE and Std-ICE arms, respectively. No differences were observed between the High-ICE and Std-ICE arms in overall response (n = 54 [78%, 95% CI = 67% to 87%] and n = 48 [68%, 95% CI = 55% to 78%], respectively) or complete response (n = 27 [39%, 95% CI = 28% to 52%] and n = 24 [34%, 95% CI = 23% to 46%], respectively). Subgroup analyses showed no benefit for any outcome from High-ICE treatment. Hematologic toxicity was substantial in the Std-ICE arm (grade > or = 3 neutropenia, n = 49 [70%]; anemia, n = 17 [25%]; thrombopenia, n = 17 [25%]), and three patients (4%) died from toxicity. High-ICE treatment was predictably associated with severe myelosuppression, and five patients (8%) died from toxicity. CONCLUSIONS: The long-term outcome of SCLC was not improved by raising the dose intensity of ICE chemotherapy by threefold.
Resumo:
We report the case of an 11-year-old female treated for mediastinal T-cell lymphoma who presented renal failure following the second cycle of high-dose methotrexate (HDMTX). Because of life threatening plasma methotrexate (MTX) levels, carboxypeptidase G2 (CPDG2) was administered resulting in a dramatic decrease within 1 hr. The patient recovered from renal failure and no other side effects were observed. Homozygosity for the methylentetrahydrofolate reductase (MTHFR) C677T polymorphism diagnosed by molecular genetic analysis was the only explanation for this toxicity.