861 resultados para Clinical assessment


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO(TM) is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. OBJECTIVE: To evaluate the potential of VEO(TM) on diagnostic image quality and dose reduction in pediatric chest CT examinations. MATERIALS AND METHODS: Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDIvol 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. RESULTS: At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. CONCLUSIONS: At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the combination of ultrasound (US) + fine-needle aspiration (FNA) in the assessment of salivary gland tumours in the hands of the otolaryngologist. DESIGN: A retrospective review of case notes was performed. SETTING: Two university teaching hospitals in Switzerland. PARTICIPANTS: One hundred and three patients with a total of 106 focal masses of the salivary glands were included. Clinician-operated US + FNA were the first line of investigation for these lesions. All patients underwent surgical excision of the lesion, which allowed for confirmation of diagnosis by histopathology in 104 lesions and by laboratory testing in two lesions. MAIN OUTCOME MEASURES: Primary--diagnostic accuracy in identifying true salivary gland neoplasms and detecting malignancy. Secondary--predicting an approximate and specific diagnosis in these tumours. RESULTS: The combination of US + FNA achieved a diagnostic accuracy of 99% in identifying and differentiating true salivary gland neoplasms from tumour-like lesions. In detecting malignancy, this combination permitted an accuracy of 98%. An approximate diagnosis was possible in 89%, and a specific diagnosis in 69% of our patients. CONCLUSIONS: Due to economic factors and a high diagnostic accuracy, the combination of US + FNA represents the investigation method of choice for most salivary gland tumours. We suggest that the otolaryngologist be employed in carrying out these procedures, as is already the rule in other medical specialties, while computed tomography and magnetic resonance imaging should be reserved to those few lesions, which cannot be delineated completely by sonography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Infliximab (IFX), adalimumab (ADA), and certolizumab pegol (CZP) have similar efficacy in induction and maintenance of clinical remission in Crohn's disease (CD). Given the comparable nature of these drugs, patient preferences may influence the choice of the product. We aimed to identify factors that may contribute to CD patients' decision in selecting one anti-tumor necrosis factor (TNF) agent over the others. METHODS: A prospective survey was performed among anti-TNF-naïve CD patients. Prior to completion of a questionnaire, patients were provided with a written description of the three anti-TNF agents, focusing on indications, mode of administration, side effects, and scientific evidence of efficacy and safety for each drug. RESULTS: One hundred patients (47 females, mean age 45 ± 16 years, range 19-81) with an ileal, colonic, or ileocolonic (33%, 40%, and 27%, respectively) disease location completed the questionnaire. Based on the information provided, 36% of patients preferred ADA, 28% CZP, and 25% IFX, whereas 11% were undecided. The patients' decision in selecting a specific anti-TNF drug was influenced by the following factors: ease of use (69%), time required for therapy (34%), time interval between application of the drug (31%), scientific evidence for efficacy (19%), and fear of syringes (10%). CONCLUSIONS: The majority of patients preferred anti-TNF medications that were administered by subcutaneous injection rather than by intravenous infusion. Ease of use and time required for therapy were two major factors influencing the patients' selection of a specific anti-TNF drug. Patients' individual preferences should be taken into account when prescribing anti-TNF drugs. (Inflamm Bowel Dis 2012).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The best indirect evidence that increased bone turnover contributes to fracture risk is the fact that most of the proven therapies for osteoporosis are inhibitors of bone turnover. The evidence base that we can use biochemical markers of bone turnover in the assessment of fracture risk is somewhat less convincing. This relates to natural variability in the markers, problems with the assays, disparity in the statistical analyses of relevant studies and the independence of their contribution to fracture risk. More research is clearly required to address these deficiencies before biochemical markers might contribute a useful independent risk factor for inclusion in FRAX(®).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The value of various indexes to characterize the stimulus-response curve of human motor nerves was assessed in 40 healthy subjects recruited from four European centers of investigation (Créteil, Lausanne, Liège, Marseille). Stimulus-response curves were established by stimulating the right median and ulnar motor nerves at the wrist, with stimulus durations of 0.05 and 0.5 ms. The following parameters were studied: the threshold intensity of stimulation to obtain 10% (I 10), 50% (I 50), and 90% (I 90) of the maximal compound muscle action potential, the ratios I 10/I 50, I 90/I 50, (I 90 - I 10)/I 10, (I 90-I 50)/I 50, and (I 50 - I 10)/I 10, and the slopes of the stimulus-response curves with or without normalization to I 50. For each parameter, within-center variability and reproducibility (in a test-retest study) were assessed and between-center comparisons were made. For most of the parameters, the results varied significantly within and between the centers. Within the centers, only the ratios I 10/I 50 and I 90/I 50 were found constant and reproducible. Between the centers, the absolute intensity thresholds (I 10, I 50, I 90) and the ratio I 90/I 50 did not show significant differences at stimulus duration of 0.5 ms, whatever the stimulated nerve. The reduced variability and good reproducibility of the ratios I 10/I 50 and I 90/I 50 open perspectives in neurophysiological practice for the use of these indexes of the stimulus-response curve, a rapid and noninvasive test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Exposure to combination antiretroviral therapy (cART) can lead to important metabolic changes and increased risk of coronary heart disease (CHD). Computerized clinical decision support systems have been advocated to improve the management of patients at risk for CHD but it is unclear whether such systems reduce patients' risk for CHD. METHODS: We conducted a cluster trial within the Swiss HIV Cohort Study (SHCS) of HIV-infected patients, aged 18 years or older, not pregnant and receiving cART for >3 months. We randomized 165 physicians to either guidelines for CHD risk factor management alone or guidelines plus CHD risk profiles. Risk profiles included the Framingham risk score, CHD drug prescriptions and CHD events based on biannual assessments, and were continuously updated by the SHCS data centre and integrated into patient charts by study nurses. Outcome measures were total cholesterol, systolic and diastolic blood pressure and Framingham risk score. RESULTS: A total of 3,266 patients (80% of those eligible) had a final assessment of the primary outcome at least 12 months after the start of the trial. Mean (95% confidence interval) patient differences where physicians received CHD risk profiles and guidelines, rather than guidelines alone, were total cholesterol -0.02 mmol/l (-0.09-0.06), systolic blood pressure -0.4 mmHg (-1.6-0.8), diastolic blood pressure -0.4 mmHg (-1.5-0.7) and Framingham 10-year risk score -0.2% (-0.5-0.1). CONCLUSIONS: Systemic computerized routine provision of CHD risk profiles in addition to guidelines does not significantly improve risk factors for CHD in patients on cART.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Waterproofing agents are widely used to protect leather and textiles in both domestic and occupational activities. An outbreak of acute respiratory syndrome following exposure to waterproofing sprays occurred during the winter 2002-2003 in Switzerland. About 180 cases were reported by the Swiss Toxicological Information Centre between October 2002 and March 2003, whereas fewer than 10 cases per year had been recorded previously. The reported cases involved three brands of sprays containing a common waterproofing mixture, that had undergone a formulation change in the months preceding the outbreak. A retrospective analysis was undertaken in collaboration with the Swiss Toxicological Information Centre and the Swiss Registries for Interstitial and Orphan Lung Diseases to clarify the circumstances and possible causes of the observed health effects. Individual exposure data were generated with questionnaires and experimental emission measurements. The collected data was used to conduct numeric simulation for 102 cases of exposure. A classical two-zone model was used to assess the aerosol dispersion in the near- and far-field during spraying. The resulting assessed dose and exposure levels obtained were spread on large scales, of several orders of magnitude. No dose-response relationship was found between exposure indicators and health effects indicators (perceived severity and clinical indicators). Weak relationships were found between unspecific inflammatory response indicators (leukocytes, C-reactive protein) and the maximal exposure concentration. The results obtained disclose a high interindividual response variability and suggest that some indirect mechanism(s) predominates in the respiratory disease occurrence. Furthermore, no threshold could be found to define a safe level of exposure. These findings suggest that the improvement of environmental exposure conditions during spraying alone does not constitute a sufficient measure to prevent future outbreaks of waterproofing spray toxicity. More efficient preventive measures are needed prior to the marketing and distribution of new waterproofing agents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Risk factors for fracture can be purely skeletal, e.g., bone mass, microarchitecture or geometry, or a combination of bone and falls risk related factors such as age and functional status. The remit of this Task Force was to review the evidence and consider if falls should be incorporated into the FRAX® model or, alternatively, to provide guidance to assist clinicians in clinical decision-making for patients with a falls history. It is clear that falls are a risk factor for fracture. Fracture probability may be underestimated by FRAX® in individuals with a history of frequent falls. The substantial evidence that various interventions are effective in reducing falls risk was reviewed. Targeting falls risk reduction strategies towards frail older people at high risk for indoor falls is appropriate. This Task Force believes that further fracture reduction requires measures to reduce falls risk in addition to bone directed therapy. Clinicians should recognize that patients with frequent falls are at higher fracture risk than currently estimated by FRAX® and include this in decision-making. However, quantitative adjustment of the FRAX® estimated risk based on falls history is not currently possible. In the long term, incorporation of falls as a risk factor in the FRAX® model would be ideal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Efforts are being made by clinicians and researchers to accurately delineate phenotypic traits of individuals at enhanced risk of schizophrenia. This issue is important for a better understanding of the etiopathogenic mechanisms of the disease and for the building up of programs of primary prevention. We suggest that disturbances of subjective experience, although difficult to operationalize, are an important-but until now neglected-core component of schizophrenia spectrum disorders. We advocate the development of valid and reliable instruments in order to allow the assessment of basic symptoms and disturbances of Self-experience. Delineation of vulnerability to schizophrenia cannot rely solely on neuropsychological and neurophysiological data, as prevention programs will be performed mainly by clinicians.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To determine 1) HIV testing practices in a 1400-bed university hospital where local HIV prevalence is 0.4% and 2) the effect on testing practices of national HIV testing guidelines, revised in March 2010, recommending Physician-Initiated Counselling and Testing (PICT). METHODS: Using 2 hospital databases, we determined the number of HIV tests performed by selected clinical services, and the number of patients tested as a percentage of the number seen per service ('testing rate'). To explore the effect of the revised national guidelines, we examined testing rates for two years pre- and two years post-PICT guideline publication. RESULTS: Combining the clinical services, 253,178 patients were seen and 9,183 tests were performed (of which 80 tested positive, 0.9%) in the four-year study period. The emergency department (ED) performed the second highest number of tests, but had the lowest testing rates (0.9-1.1%). Of inpatient services, neurology and psychiatry had higher testing rates than internal medicine (19.7% and 9.6% versus 8%, respectively). There was no significant increase in testing rates, either globally or in the majority of the clinical services examined, and no increase in new HIV diagnoses post-PICT recommendations. CONCLUSIONS: Using a simple two-database tool, we observe no global improvement in HIV testing rates in our hospital following new national guidelines but do identify services where testing practices merit improvement. This study may show the limit of PICT strategies based on physician risk assessment, compared to the opt-out approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Evaluation of glomerular hyperfiltration (GH) is difficult; the variable reported definitions impede comparisons between studies. A clear and universal definition of GH would help in comparing results of trials aimed at reducing GH. This study assessed how GH is measured and defined in the literature. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Three databases (Embase, MEDLINE, CINAHL) were systematically searched using the terms "hyperfiltration" or "glomerular hyperfiltration". All studies reporting a GH threshold or studying the effect of a high GFR in a continuous manner against another outcome of interest were included. RESULTS: The literature search was performed from November 2012 to February 2013 and updated in August 2014. From 2013 retrieved studies, 405 studies were included. Threshold use to define GH was reported in 55.6% of studies. Of these, 88.4% used a single threshold and 11.6% used numerous thresholds adapted to participant sex or age. In 29.8% of the studies, the choice of a GH threshold was not based on a control group or literature references. After 2004, the use of GH threshold use increased (P<0.001), but the use of a control group to precisely define that GH threshold decreased significantly (P<0.001); the threshold did not differ among pediatric, adult, or mixed-age studies. The GH threshold ranged from 90.7 to 175 ml/min per 1.73 m(2) (median, 135 ml/min per 1.73 m(2)). CONCLUSION: Thirty percent of studies did not justify the choice of threshold values. The decrease of GFR in the elderly was rarely considered in defining GH. From a methodologic point of view, an age- and sex-matched control group should be used to define a GH threshold.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[Table des matières] Technology assessment in health care in the United States: an historical review / S. Perry. - The aims and methods of technology assessment / JH Glasser. - Evaluation des technologies de la santé / A. Griffiths. - Les données nécessaires pour l'évaluation des technologies médicales / R. Chrzanowski, F. Gutzwiller, F. Paccaud. - Economic issues in technology assessment/DR Lairson, JM Swint. - Two decades of experience in technology assessment: evaluating the safety, performance, and cost effectiveness of medical equipment / JJ Nobel. - Demography and technology assessment / H. Hansluwka. - Méthodes expérimentale et non expérimentale pour l'évaluation des innovations technologiques / R. Chrzanowski, F. Paccaud. - Skull radiography in head trauma: a successful case of technology assessment / NT Racoveanu. - Complications associées à l'anesthésie: une étude prospective en France / L. Tiret et al. - Impact de l'information publique sur les taux opératoires: le cas de l'hystérectomie / G. Domenighetti, P. Luraschi, A. Casabianca. - The clinical effectiveness of acupuncture for the relief of chronic pain / MS Patel, F. Gutzwiller, F. Paccaud, A. Marazzi. - Soins à domicile et hébergement à long terme: à la recherche d'un développement optimum / G. Tinturier. - Economic evaluation of six scenarios for the treatment of stones in the kidney and ureter by surgery or ESWL / MS Patel et al. - Technology assessment and medical practice / F. Gutzwiller. - Technology assessment and health policy / SJ Reiser. - Global programme on appropriate technology for health, its role and place within WHO / K. Staehr Johansen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MRI has evolved into an important diagnostic technique in medical imaging. However, reliability of the derived diagnosis can be degraded by artifacts, which challenge both radiologists and automatic computer-aided diagnosis. This work proposes a fully-automatic method for measuring image quality of three-dimensional (3D) structural MRI. Quality measures are derived by analyzing the air background of magnitude images and are capable of detecting image degradation from several sources, including bulk motion, residual magnetization from incomplete spoiling, blurring, and ghosting. The method has been validated on 749 3D T(1)-weighted 1.5T and 3T head scans acquired at 36 Alzheimer's Disease Neuroimaging Initiative (ADNI) study sites operating with various software and hardware combinations. Results are compared against qualitative grades assigned by the ADNI quality control center (taken as the reference standard). The derived quality indices are independent of the MRI system used and agree with the reference standard quality ratings with high sensitivity and specificity (>85%). The proposed procedures for quality assessment could be of great value for both research and routine clinical imaging. It could greatly improve workflow through its ability to rule out the need for a repeat scan while the patient is still in the magnet bore.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated whether a single blood measurement using the minimally invasive technique of a finger prick to draw a blood sample of 5 µl (to yield a dried blood spot (DBS)) is suitable for the assessment of flurbiprofen (FLB) metabolic ratio (MR). Ten healthy volunteers who had been genotyped for CYP2C9 were recruited as subjects. They received FLB alone in session 1 and FLB with fluconazole in session 2. In session 3, the subjects were pretreated for 4 days with rifampicin and received FLB with the last dose of rifampicin on day 5. Plasma and DBS samples were obtained between 0 and 8 h after FLB administration, and urine was collected during the 8 h after administration. The pharmacokinetic profiles of the drugs were comparable in DBS and plasma. FLB's apparent clearance values decreased by 35% in plasma and DBS during session 2 and increased by 75% in plasma and by 30% in DBS during session 3. Good correlations were observed between MRs calculated from urine, plasma, and DBS samples.