978 resultados para Chromatographic columns


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Copaiba oil is a resin extracted from the trunk of trees of Copaifera species which grow in Brazil where it is widely used in popular medicine as an anti-inflammatory, antiseptic anti-bactericidal, diuretic, dermatological, expectorant, and anti-infective. The comparative study of the composition of commercial copaiba oils was carried out by high resolution gas chromatography (HRGC) and high resolution gas chromatography-mass spectrometry (HRGC-MS) analysis. The commercial oils were compared with authentic oils, collected from the southeast and northern regions of Brazil. Sixteen commercial oils were analysed and two of them revealed adulterations with fatty acids. Using the chromatographic profile of authentic copaiba species oils, it is possible to analyse commercial oils and determine the authenticity of these materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two models of a glass micro-extractor were constructed after modification of a model proposed in the literature. The two models were used for the simultaneous extraction and enrichment of organochlorinated pesticides from aqueous matrixes to an organic solution appropriate for the gas chromatographic analysis of the pesticide. It was established that the performance of one of the modified micro-extractors permits the pre-concentration of the pesticides to a level that allow their quantitation at the trace level with electron capture detection. It is thus concluded that the glass micro-extractor is a suitable tool for the sample preparation step in the gas chromatographic analysis of environmental pollutants of the class of pesticides.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A brief discussion of the non-chromatographic continuous separation techniques is presented emphasizing the pervaporation process. It makes interesting choices for implementing various preliminary operations of the analytical process in order to accommodate the raw sample to the measuring instrument. Discussions include the perceived advantages and disadvantages, the underlying principles of pervaporation process, the flexible module and fields of application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this way it is very important to know the sulfate concentration in vinasse samples before to make the biodigestor design. A previous developed and indirect method (Anal. Chim. Acta. 1996, 329, 197), was used to determine sulfate in samples of vinasse, after previous treatments, done in order to eliminate organic matter with hydrogen peroxide 30% and concentrated nitric acid mixture (3:1), under heating. Interferent cationic ions were isolated by using ion exchange columns. The results obtained for some samples from Araraquara and Penápolis are here presented. The phosphate concentration was also determined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Extracts obtained from leaves, seeds and bark of Unonopsis lindmanii were evaluated by means of Brine Shrimp Lethality test (BSL). Through bioassay-guided chromatographic fractionation, liriodenine, an oxoaporphine alkaloid, was isolated from the bark extracts as the bioactive compound. Two additional inactive known alkaloids, unonopsine and lysicamine were also isolated from the bark extracts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Weak acid cation exchange (WAC) resins are used in the chromatographic separation of betaine from vinasse, a by-product of sugar industry. The ionic form of the resin determines the elution time of betaine. When a WAC-resin is in hydrogen form, the retention time of betaine is the longest and betaine elutes as the last component of vi-nasse from the chromatographic column. If the feed solution contains salts and its pH is not acidic enough to keep the resin undissociated, the ionic form of the hydrogen form resin starts to alter. Vinasse contains salts and its pH is around 5, it also contains weak acids. To keep the metal ion content (Na/H ratio) of the resin low enough to ensure successful separation of betaine, acid has to be added to either eluent (water) or vinasse. The aim of the present work was to examine by laboratory experiments which option requires less acid. Also the retention mechanism of betaine was investigated by measuring retention volumes of acetic acid and choline in different Na/H ratios of the resin. It was found that the resulting ionic form of the resin is the same regardless of whether the regeneration acid is added to the eluent or the feed solution (vinasse). Be-sides the salt concentration and the pH of vinasse, also the concentration of weak acids in the feed affects the resulting ionic form of the resin. The more buffering capacity vinasse has, the more acid is required to keep the ionic form of the resin desired. Vinasse was found to be quite strong buffer solution, which means relatively high amounts of acid are required to prevent the Na/H ratio from increasing too much. It is known that the retention volume of betaine decreases significantly, when the Na/H ratio increases. This is assumed to occur, because the amount of hydrogen bonds between the carboxylic groups of betaine and the resin decreases. Same behavior was not found with acetic acid. Choline has the same molecular structure as betaine, but instead of carboxylic group it has hydroxide group. The retention volume of choline increased as the Na/H ratio of the resin increased, because of the ion exchange reaction between choline cation and dissociated carboxylic group of the resin. Since the retention behavior of choline on the resin is opposite to the behavior of be-taine, the strong affinity of betaine towards hydrogen form WAC-resin has to be based on its carboxylic group. It is probable that the quaternary ammonium groups also affect the behavior of the carboxylic groups of betaine, causing them to form hydrogen bonds with the carboxylic groups of the resin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The technique of solid phase microextraction (SPME) was used for the extraction of halogenated contaminants of water samples from three cities of the State of São Paulo and the extracts were submitted to gas chromatographic analysis with electron capture detection (GC-ECD). In the samples of water collected at the city of São Paulo the detected level of trihalomethanes (THM) expressed as the sum of chloroform, dibromochloromethane and dichlorobromomethane, were higher than the permissible limit established by the Brazilian regulation. In the samples collected at the two other cities the level of any of the three THM remained below the sensitivity of the ECD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this report is to classify analytical methods based on flowing media and to define (standardize) terminology. After the classification and a discussion of terms describing the systems and component parts, a section is devoted to terms describing the performance of flow systems. The list of terms included is restricted to the most relevant ones; especially "self-explanatory" terms are left out. It is emphasised that the usage of terms or expressions that do not adequately describe the processes or procedures involved should be strongly discouraged. Although belonging to the category of methods based on flowing media, chromatographic methods are not comprised in the present document. However, care has been taken that the present text is not in conflict with definitions in that domain. In documents in which flow methods are described, it should be clearly indicated how the sample and/or reagent is introduced and how the sample zone is transported. When introducing new techniques in the field, or variants of existing techniques, it is strongly recommended that descriptive terms rather than trivial or elaborate names are used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents a comparison between three analytical methods developed for the simultaneous determination of eight quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, sarafloxacin, oxolinic acid and flumequine) in pig muscle, using liquid chromatography with fluorescence detection (LC-FD), liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The procedures involve an extraction of the quinolones from the tissues, a step for clean-up and preconcentration of the analytes by solid-phase extraction and a subsequent liquid chromatographic analysis. The limits of detection of the methods ranged from 0.1 to 2.1 ng g−1 using LC-FD, from 0.3 to 1.8 using LC-MS and from 0.2 to 0.3 using LC-MS/MS, while inter- and intra-day variability was under 15 % in all cases. Most of those data are notably lower than the maximum residue limits established by the European Union for quinolones in pig tissues. The methods have been applied for the determination of quinolones in six different commercial pig muscle samples purchased in different supermarkets located in the city of Granada (south-east Spain).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The applicability of the silylant agents of the general formula Y3Si-R-X, depends on the reactivity of Y group (halide or alcoxide) attached to silicon and the organic function X (halide, amine, thiol, cyanide, etc) in the extreme position of the chain. Both groups are linked together by an organic chain R, containing usually three methylene groups. A series of these agents can be covalently bonded to an inorganic matrix, since the available OH groups are distributed on the surface, making silica gel the most common support. However, other inorganic oxides, zeolites, lamellar inorganic phosphates and chrysotile can also have these agents anchored. Some illustration are presented for immobilized surface in the use as extractors of cations from dilute aqueous or non-aqueous solutions, catalysts agents, ionic exchanged materials, support for enzyme immobilization, chromatographic applications, use in some industrial features and in many other areas. The evolution of this exciting research field to produce new materials, for many tecnological applications, is strongly dependent on the development of a sensible systematic process for the synthesis of a series of new specific silylant agents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to evaluate the adsorption conditions of zinc and cadmium ions from aqueous solutions using a comercially available peat from Balneário Arroio do Silva, Santa Catarina State, Brazil. Adsorption studies were carried out in column experiments using radiotracers of the studied metals (65Zn and 115Cd). The pH influence and the interference of other ions, such as Na+, Ca2+, Fe3+ and Al3+on the adsorption process were investigated. The results showed that peat columns are able to retain more than 99% of metal ions in solution in a range of pH from 3,7 to 6,5. Ca2+ and Al3+ ions were the main interferent on adsorption of Zn and Cd ions in solution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundamental aspects of Solid Phase Micro-Extraction (SPME) are discussed in the present paper. The application of SPME as a microtechnique of sample preparation for gas chromatographic analysis is considered and related to existing theoretical models. Both research prototypes and commercial SPME devices are considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we intend to eliminate the idea that laboratory exercises seem like cookbooks. That is, exercises shall be presented as a problematic situation. Based on observation and experimentation, the students should determine the E-Z configuration of maleic and fumaric acids. The basis of this laboratory exercise is the acid-catalyzed isomerization of maleic acid to fumaric acid. Students are given the starting material, reagents and the experimental procedure. They are told that the starting material is a dicarboxylic acid containing a C=C double bond of formula C4H4O4. Students determine melting points, solubilities, acidity and chromatographic patterns for both the starting material and the product, so that a configuration of each acid can be proposed. This type of experiment yields excellent results, because the students are left to deduce that maleic acid is less stable than fumaric acid. Additionally, they conclude that maleic acid is the "Z" isomer and fumaric acid is the "E" isomer. Finally, this laboratory exercise allows the students to develop simultaneously their critical-thinking skills with the respective laboratory techniques and not to see chemistry as recipes to be followed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A capillary microtrap thermal desorption module is developed for near real-time analysis of volatile organic compounds (VOCs) at sub-ppbv levels in air samples. The device allows the direct injection of the thermally desorbed VOCs into a chromatographic column. It does not use a second cryotrap to focalize the adsorbed compounds before entering the separation column so reducing the formation of artifacts. The connection of the microtrap to a GC–MS allows the quantitative determination of VOCs in less than 40 min with detection limits of between 5 and 10 pptv (25 °C and 760 mmHg), which correspond to 19–43 ng m−3, using sampling volumes of 775 cm3. The microtrap is applied to the analysis of environmental air contamination in different laboratories of our faculty. The results obtained indicate that most volatile compounds are easily diffused through the air and that they also may contaminate the surrounding areas when the habitual safety precautions (e.g., working under fume hoods) are used during the manipulation of solvents. The application of the microtrap to the analysis of VOCs in breath samples suggest that 2,5-dimethylfuran may be a strong indicator of a person's smoking status

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When organic compounds present in biological fluids are analysed by chromatographic methods, it is generally necessary to carry out a prior sample preparation due the high complexity of this type of sample, especially when the compounds to be determinated are found in very low concentrations. This article describes some of the principal methods for sample preparation in analyses of substances present in biological fluids. The methods include liquid-liquid extraction, solid phase extraction, supercritical fluid extraction and extraction using solid and liquid membranes. The advantages and disadvantages of these methods are discussed.