977 resultados para Bridge railings.
Resumo:
The thesis explores recent technology developments in the field of structural health monitoring and its application to railway bridge projects. It focuses on two main topics. First, service loads and effect of environmental actions are modelled. In particular, the train moving load and its interaction with rail track is considered with different degrees of detail. Hence, results are compared with real-time experimental measurements. Secondly, the work concerns the identification, definition and modelling process of damages for a prestressed concrete railway bridge, and their implementation inside FEM models. Along with a critical interpretation of the in-field measurements, this approach results in the development of undamaged and damaged databases for the AI-aided detection of anomalies and the definition of threshold levels to prompt automatic alert interventions. In conclusion, an innovative solution for the development of the railway weight-in-motion system is proposed.
Resumo:
Nowadays, there is a boom in the use of electrification. Electric vehicles are gaining interest worldwide due to various factors, including climate and environmental awareness. In this thesis, a step-down isolated power supply for electric tractors is investigated, specifically the phase-shifted full-bridge (PSFB) DC-DC with synchronous rectification and zero-voltage switching (ZVS). This converter was selected for its high-power capacity with high efficiency. A 3500 W PSFB converter with peak current control (PCCM) is designed and modeled in MATLAB. The input voltage range is from 550 V to 820 V and the output voltage range is limited to 9 V to 16 V with a maximum output current of 250 A. All components were commercially designed and selected, including magnetics for the high-frequency transformer and inductors, taking into account loss calculations. Zero voltage switching for the lagging leg is achieved at 13% to 100% load. The proven efficiency of the converter is around 90
Resumo:
In questa tesi ho analizzato il passaggio dall'ambiente BIM a quello FEM di un impalcato da ponte a travata precompressa, identificando criteri e applicando una metodologia che hanno consentito lo sviluppo di un modello FEM utilizzabile per l'analisi strutturale. Nella tesi si descrive l'opera e il suo dimensionamento, con l'analisi statica e le verifiche strutturali eseguite sia a mano sia sul modello in ambiente FEM importato dall'ambiente BIM. Oltre a ciò, viene modellata l'opera nella sua interezza ed inserita in un contesto reale. La tesi discute l'interoperabilità tra i due software evidenziando vantaggi (modello geometrico di partenza in ambiente FEM, trasferimento di informazioni inserite in ambiente BIM, riduzione dei tempi di modellazione e inserimento proprietà dei materiali e caratteristiche degli oggetti, inserimento armature di precompressione) e criticità (implementazione manuale di alcuni elementi nel modello geometrico, perdita di alcune informazioni, definizione di alcuni parametri, limitata interoperabilità FEM-BIM) della metodologia applicata.
Resumo:
This master's thesis investigates different aspects of Dual-Active-Bridge (DAB) Converter and extends aspects further to Multi-Active-Bridges (MAB). The thesis starts with an overview of the applications of the DAB and MAB and their importance. The analytical part of the thesis includes the derivation of the peak and RMS currents, which is required for finding the losses present in the system. The power converters, considered in this thesis are DAB, Triple-Active Bridge (TAB) and Quad-Active Bridge (QAB). All the theoretical calculations are compared with the simulation results from PLECS software for identifying the correctness of the reviewed and developed theory. The Hardware-in-the-Loop (HIL) simulation is conducted for checking the control operation in real-time with the help of the RT box from the Plexim. Additionally, as in real systems digital signal processor (DSP), system-on-chip or field programmable gate array is employed for the control of the power electronic systems, and the execution of the control in the real-time simulation (RTS) conducted is performed by DSP.
Resumo:
Il progetto di tesi nasce dall’interesse e dalla passione verso il mondo della Cybersecurity, che da sempre segna il mio percorso accademico e di vita, ma che durante questo ultimo anno di università ha avuto particolare rilevanza. Il progetto è stato svolto con il supporto e la supervisione del team Railway dell’azienda ALTEN Italia presso la sede di Bologna. Il lavoro di tesi mira allo sviluppo di un componente software che rappresenta un livello aggiuntivo di sicurezza nella comunicazione tra sistemi di bordo e di terra. In particolare, il progetto si pone come obiettivo la creazione di un Bridge, ovvero un componente software indipendente e configurabile che si interfaccia sia con il client che con il server, con lo scopo di garantire autenticità e cifratura dei messaggi scambiati tra le due entità. Inoltre, la potenza del Bridge sta nel fatto che nasce come possibile soluzione ai problemi di sicurezza informatica in ambito ferroviario, ma la sua applicabilità può essere estesa anche ad altri settori in cui sia presente una comunicazione client/server da rendere sicura. Infatti, tale software risulta particolarmente flessibile e adattabile, attraverso l’impostazione a priori di parametri di configurazione, in base al tipo di comunicazione che si desidera implementare tra le due entità. Per questo motivo, si ritiene che la forza del progetto sia la possibilità di fornire una soluzione software per proteggere l’infrastruttura critica dei trasporti ferroviari da eventuali minacce informatiche, ma anche la capacità adattiva del Bridge, in grado di svolgere le sue funzioni di sicurezza in un ampio ventaglio di ambiti di applicazione.
Resumo:
The IoT is growing more and more each year and is becoming so ubiquitous that it includes heterogeneous devices with different hardware and software constraints leading to an highly fragmented ecosystem. Devices are using different protocols with different paradigms and they are not compatible with each other; some devices use request-response protocols like HTTP or CoAP while others use publish-subscribe protocols like MQTT. Integration in IoT is still an open research topic. When handling and testing IoT sensors there are some common task that people may be interested in: reading and visualizing the current value of the sensor; doing some aggregations on a set of values in order to compute statistical features; saving the history of the data to a time-series database; forecasting the future values to react in advance to a future condition; bridging the protocol of the sensor in order to integrate the device with other tools. In this work we will show the working implementation of a low-code and flow-based tool prototype which supports the common operations mentioned above, based on Node-RED and Python. Since this system is just a prototype, it has some issues and limitations that will be discussed in this work.
Resumo:
To evaluate patients with transverse fractures of the shaft of the humerus treated with indirect reduction and internal fixation with plate and screws through minimally invasive technique. Inclusion criteria were adult patients with transverse diaphyseal fractures of the humerus closed, isolated or not occurring within 15 days of the initial trauma. Exclusion criteria were patients with compound fractures. In two patients, proximal screw loosening occurred, however, the fractures consolidated in the same mean time as the rest of the series. Consolidation with up to 5 degrees of varus occurred in five cases and extension deficit was observed in the patient with olecranon fracture treated with tension band, which was not considered as a complication. There was no recurrence of infection or iatrogenic radial nerve injury. It can be concluded that minimally invasive osteosynthesis with bridge plate can be considered a safe and effective option for the treatment of transverse fractures of the humeral shaft. Level of Evidence III, Therapeutic Study.
Resumo:
Minor structural alterations of the vocal fold cover are frequent causes of voice abnormalities. They may be difficult to diagnose, and are expressed in different manners. Cases of intracordal cysts, sulcus vocalis, mucosal bridge, and laryngeal micro-diaphragm form the group of minor structural alterations of the vocal fold cover investigated in the present study. The etiopathogenesis and epidemiology of these alterations are poorly known. To evaluate the existence and anatomical characterization of minor structural alterations in the vocal folds of newborns. 56 larynxes excised from neonates of both genders were studied. They were examined fresh, or defrosted after conservation via freezing, under a microscope at magnifications of 25× and 40×. The vocal folds were inspected and palpated by two examiners, with the aim of finding minor structural alterations similar to those described classically, and other undetermined minor structural alterations. Larynges presenting abnormalities were submitted to histological examination. Six cases of abnormalities were found in different larynges: one (1.79%) compatible with a sulcus vocalis and five (8.93%) compatible with a laryngeal micro-diaphragm. No cases of cysts or mucosal bridges were found. The observed abnormalities had characteristics similar to those described in other age groups. Abnormalities similar to sulcus vocalis or micro-diaphragm may be present at birth.
Resumo:
Homo and heterotrinuclear acetates are unique compounds having μ3-oxo bridge and many interesting properties of such compounds are derived from this structure. Some undergraduate inorganic textbooks discuss several aspects of these compounds and we present here an undergraduate experiment for the high-yield synthesis of [Fe2MO(CH3CO2)6(H 2O)3], with M = Fe3+, Co2+ and Ni2+, as well as their characterization using infrared spectroscopy and cyclic voltametry. The proposed experiment gives the opportunity to discuss several concepts of coordination chemistry that follow the characterization techniques, such as: types of acetate coordination, reversibility of electrochemical processes, quelate and trans effects and lability.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Two clinical cases in which Portland cement (PC) was applied as a medicament after pulpotomy of mandibular primary molars in children are presented. Pulpotomy using PC was carried out in two mandibular first molars and one mandibular second molar, which were further followed-up. At the 3, 6 and 12-month follow-up appointments, clinical and radiographic examinations of the pulpotomized teeth and their periradicular area revealed that the treatments were successful in maintaining the teeth asymptomatic and preserving pulpal vitality. Additionally, the formation of a dentin bridge immediately below the PC could be observed in the three molars treated. PC may be considered as an effective alternative for primary molar pulpotomies, at least in a short-term period. Randomized clinical trials with human teeth are required in order to determine the suitability of PC before unlimited clinical use can be recommended.
Resumo:
Neste artigo apresentamos uma descrição geral da física do violino, analisando os conceitos que lhes dão sustentação física e que revelam toda a riqueza e o potencial pedagógico do assunto. Destacamos as contribuições de físicos como Helmholtz, Savart, Raman e Saunders no esforço para descrever a vibração produzida pelo arco nas cordas, e por compreender as propriedades acústicas do instrumento. Descrevemos a função de cada uma das componentes do instrumento e discutimos a importância dos modos normais de vibração dos tampos e do cavalete na resposta acústica do violino. A ressonância acústica da caixa do violino (ressonância de Helmholtz) será discutida fazendo-se um paralelo entre osciladores mecânico, elétrico e acústico. Discutiremos a resposta acústica do violino e descreveremos a produção de seu som caraterístico, que resulta da forma de onda originada pela excitação das cordas pelo arco, influenciada pelas vibrações e ressonâncias do corpo do violino, seus tampos e o cavalete.
Resumo:
The aqueous alkaline reaction of 1,3-bis(4-cyanopyridinium)propane dibromide, a reactant constituted of two pyridinium rings linked by a three-methylene bridge, generates a novel compound,1 -(4-cyano-2-oxo-1,2-dihydro-1-pyridyl)-3-(4-cyano-1,2-dihydro-1-pyridyl)propane. The reaction pathway is attributed to the proximity of the OH- ion inserted between two pyridinium moieties, which occurs only in bis(pyridinium) derivatives connected by short methylene spacers, where charge-conformational effects are important.
Resumo:
A distribuição intraparenquimal das veias porta-hepáticas foi estudada em 30 gansos domésticos. Latex Neoprene corado foi injetado pela veia isquiática e os animais forma fixados por imersão e injeção intramuscular com formol a 10% e dissecados. O fígado esteve composto por um grande lobo hepático direito e por um lobo hepático esquerdo menor, os quais estiveram conectados por uma ponte de parênquima. O lobo direito do fígado teve exclusivamente vasos do sistema porta-hepático formados pela distribuição intraparenquimal da veia porta-hepática direita, enquanto que no lobo esquerdo estes originaram-se da veia porta-hepática direita e de pequenas veias porta-hepáticas esquerdas. A veia porta-hepática direita emitiu o ramo caudal direito, que emitiu um pequeno ramo caudolateral direito e um grande ramo caudomedial direito. Cranialmente esta veia emitiu os ramos craniais direito e ramos lateral direito. A porção transversa da veia porta-hepática direita cruzou para o lobo hepático esquerdo, emitindo de 1 a 6 pequenos ramos craniais e caudais para a região média do fígado. No lobo esquerdo, o ramo esquerdo da veia porta-hepática direita emitiu o ramo cranial esquerdo, o ramo lateral esquerdo e o ramo medial. De 1 a 6 veias porta-hepáticas esquerdas foram identificadas desembocando ou no ramo esquerdo da veia porta-hepática direita ou em sua porção transversa, oriundos do ventrículo gástrico e do pró-ventrículo. Em 40% dos gansos uma veia porta-hepática própria oriunda da confluência de vasos venosos da face esquerda do ventrículo distribuiu-se na extremidade caudal do lobo esquerdo isoladamente.