975 resultados para Biodegradable Medical Devices
Resumo:
BACKGROUND: Shared Decision Making (SDM) is increasingly advocated as a model for medical decision making. However, there is still low use of SDM in clinical practice. High impact factor journals might represent an efficient way for its dissemination. We aimed to identify and characterize publication trends of SDM in 15 high impact medical journals. METHODS: We selected the 15 general and internal medicine journals with the highest impact factor publishing original articles, letters and editorials. We retrieved publications from 1996 to 2011 through the full-text search function on each journal website and abstracted bibliometric data. We included publications of any type containing the phrase "shared decision making" or five other variants in their abstract or full text. These were referred to as SDM publications. A polynomial Poisson regression model with logarithmic link function was used to assess the evolution across the period of the number of SDM publications according to publication characteristics. RESULTS: We identified 1285 SDM publications out of 229,179 publications in 15 journals from 1996 to 2011. The absolute number of SDM publications by journal ranged from 2 to 273 over 16 years. SDM publications increased both in absolute and relative numbers per year, from 46 (0.32% relative to all publications from the 15 journals) in 1996 to 165 (1.17%) in 2011. This growth was exponential (P < 0.01). We found fewer research publications (465, 36.2% of all SDM publications) than non-research publications, which included non-systematic reviews, letters, and editorials. The increase of research publications across time was linear. Full-text search retrieved ten times more SDM publications than a similar PubMed search (1285 vs. 119 respectively). CONCLUSION: This review in full-text showed that SDM publications increased exponentially in major medical journals from 1996 to 2011. This growth might reflect an increased dissemination of the SDM concept to the medical community.
Resumo:
Latin medical texts transmit medical theories and practices that originated mainly in Greece. This interaction took place through juxtaposition, assimilation and transformation of ideas. 'Greek' and 'Roman' in Latin Medical Texts studies the ways in which this cultural interaction influenced the development of the medical profession and the growth of knowledge of human and animal bodies, and especially how it provided the foundations for innovations in the areas of anatomy, pathology and pharmacology, from the earliest Latin medical texts until well into the medieval world.
Resumo:
MRI visualization of devices is traditionally based on signal loss due to T(2)* effects originating from local susceptibility differences. To visualize nitinol devices with positive contrast, a recently introduced postprocessing method is adapted to map the induced susceptibility gradients. This method operates on regular gradient-echo MR images and maps the shift in k-space in a (small) neighborhood of every voxel by Fourier analysis followed by a center-of-mass calculation. The quantitative map of the local shifts generates the positive contrast image of the devices, while areas without susceptibility gradients render a background with noise only. The positive signal response of this method depends only on the choice of the voxel neighborhood size. The properties of the method are explained and the visualizations of a nitinol wire and two stents are shown for illustration.
Resumo:
This work aimed to develop a new therapeutic approach to increase the efficacy of 5-fluorouracil (5-FU) in the treatment of advanced or recurrent colon cancer. 5-FU-loaded biodegradable poly(ε-caprolactone) nanoparticles (PCL NPs) were combined with the cytotoxic suicide gene E (combined therapy). The SW480 human cancer cell line was used to assay the combined therapeutic strategy. This cell line was established from a primary adenocarcinoma of the colon and is characterized by an intrinsically high resistance to apoptosis that correlates with its resistance to 5-FU. 5-FU was absorbed into the matrix of the PCL NPs during synthesis using the interfacial polymer disposition method. The antitumor activity of gene E from the phage ϕX174 was tested by generating a stable clone (SW480/12/E). In addition, the localization of E protein and its activity in mitochondria were analyzed. We found that the incorporation of 5-FU into PCL NPs (which show no cytotoxicity alone), significantly improved the drug's anticancer activity, reducing the proliferation rate of colon cancer cells by up to 40-fold when compared with the nonincorporated drug alone. Furthermore, E gene expression sensitized colon cancer cells to the cytotoxic action of the 5-FU-based nanomedicine. Our findings demonstrate that despite the inherent resistance of SW480 to apoptosis, E gene activity is mediated by an apoptotic phenomenon that includes modulation of caspase-9 and caspase-3 expression and intense mitochondrial damage. Finally, a strongly synergistic antiproliferative effect was observed in colon cancer cells when E gene expression was combined with the activity of the 5-FU-loaded PCL NPs, thereby indicating the potential therapeutic value of the combined therapy.
Resumo:
CA88 is the first long nuclear repetitive DNA sequence identified in the blood fluke, Schistosoma mansoni. The assembled S. mansoni sequence, which contains the CA88 repeat, has 8,887 nucleotides and at least three repeat units of approximately 360 bp. In addition, CA88 also possesses an internal CA microsatellite, identified as SmBr18. Both PCR and BLAST analysis have been used to analyse and confirm the CA88 sequence in other S. mansoni sequences in the public database. PCR-acquired nuclear repetitive DNA sequence profiles from nine Schistosoma species were used to classify this organism into four genotypes. Included among the nine species analysed were five sequences of both African and Asian lineages that are known to infect humans. Within these genotypes, three of them refer to recognised species groups. A panel of four microsatellite loci, including SmBr18 and three previously published loci, has been used to characterise the nine Schistosoma species. Each species has been identified and classified based on its CA88 DNA fingerprint profile. Furthermore, microsatellite sequences and intra-specific variation have also been observed within the nine Schistosoma species sequences. Taken together, these results support the use of these markers in studying the population dynamics of Schistosoma isolates from endemic areas and also provide new methods for investigating the relationships between different populations of parasites. In addition, these data also indicate that Schistosoma magrebowiei is not a sister taxon to Schistosoma mattheei, prompting a new designation to a basal clade.
Resumo:
INTRODUCTION Although several parameters have been proposed to predict the hemodynamic response to fluid expansion in critically ill patients, most of them are invasive or require the use of special monitoring devices. The aim of this study is to determine whether noninvasive evaluation of respiratory variation of brachial artery peak velocity flow measured using Doppler ultrasound could predict fluid responsiveness in mechanically ventilated patients. METHODS We conducted a prospective clinical research in a 17-bed multidisciplinary ICU and included 38 mechanically ventilated patients for whom fluid administration was planned due to the presence of acute circulatory failure. Volume expansion (VE) was performed with 500 mL of a synthetic colloid. Patients were classified as responders if stroke volume index (SVi) increased >or= 15% after VE. The respiratory variation in Vpeakbrach (DeltaVpeakbrach) was calculated as the difference between maximum and minimum values of Vpeakbrach over a single respiratory cycle, divided by the mean of the two values and expressed as a percentage. Radial arterial pressure variation (DeltaPPrad) and stroke volume variation measured using the FloTrac/Vigileo system (DeltaSVVigileo), were also calculated. RESULTS VE increased SVi by >or= 15% in 19 patients (responders). At baseline, DeltaVpeakbrach, DeltaPPrad and DeltaSVVigileo were significantly higher in responder than nonresponder patients [14 vs 8%; 18 vs. 5%; 13 vs 8%; P < 0.0001, respectively). A DeltaVpeakbrach value >10% predicted fluid responsiveness with a sensitivity of 74% and a specificity of 95%. A DeltaPPrad value >10% and a DeltaSVVigileo >11% predicted volume responsiveness with a sensitivity of 95% and 79%, and a specificity of 95% and 89%, respectively. CONCLUSIONS Respiratory variations in brachial artery peak velocity could be a feasible tool for the noninvasive assessment of fluid responsiveness in patients with mechanical ventilatory support and acute circulatory failure. TRIAL REGISTRATION ClinicalTrials.gov ID: NCT00890071.
Resumo:
Transcatheter aortic valve implantation is an expanding procedure thus far restricted to a target population of old and high-comorbidity patients with symptomatic aortic stenosis. The need for bulky devices (up to 24F) combined with the high prevalence of peripheral vascular disease in these patients explains the increased risk of vascular complications in transfemoral Edwards Sapien (Edwards Lifesciences, Irvine, Calif) transcatheter aortic valve implantation procedures, with a rate of 20% for the transfemoral arm of either the Placement of AoRTic traNscathetER valves in the European Union (PARTNER EU) trial or the SOURCE Registry.1,2
Resumo:
Glucose control is the cornerstone of Diabetes Mellitus (DM) treatment. Although self-regulation using capillary glycemia (SRCG) still remains the best procedure in clinical practice, continuous glucose monitoring systems (CGM) offer the possibility of continuous and dynamic assessment of interstitial glucose concentration. CGM systems have the potential to improve glycemic control while decreasing the incidence of hypoglycemia but the efficiency, compared with SRCG, is still debated. CGM systems have the greatest potential value in patients with hypoglycemic unawareness and in controlling daily fluctuations in blood glucose. The implementation of continuous monitoring in the standard clinical setting has not yet been established but a new generation of open and close loop subcutaneous insulin infusion devices are emerging making insulin treatment and glycemic control more reliable.
Resumo:
Medical expenditure risk can pose a major threat to living standards. We derive decomposable measures of catastrophic medical expenditure risk from reference-dependent utility with loss aversion. We propose a quantile regression based method of estimating risk exposure from cross-section data containing information on the means of financing health payments. We estimate medical expenditure risk in seven Asian countries and find it is highest in Laos and China, and is lowest in Malaysia. Exposure to risk is generally higher for households that have less recourse to self-insurance, lower incomes, wealth and education, and suffer from chronic illness.
Resumo:
Remarkable developments can be seen in the field of optical fibre biosensors in the last decade. More sensors for specific analytes have been reported, novel sensing chemistries or transduction principles have been introduced, and applications in various analytical fields have been realised. This review consists of papers mainly reported in the last decade and presents about applications of optical fiber biosensors. Discussions on the trends in optical fiber biosensor applications in real samples are enumerated.
Resumo:
One of the key aspects in 3D-image registration is the computation of the joint intensity histogram. We propose a new approach to compute this histogram using uniformly distributed random lines to sample stochastically the overlapping volume between two 3D-images. The intensity values are captured from the lines at evenly spaced positions, taking an initial random offset different for each line. This method provides us with an accurate, robust and fast mutual information-based registration. The interpolation effects are drastically reduced, due to the stochastic nature of the line generation, and the alignment process is also accelerated. The results obtained show a better performance of the introduced method than the classic computation of the joint histogram