INTRODUCTION Although several parameters have been proposed to predict the hemodynamic response to fluid expansion in critically ill patients, most of them are invasive or require the use of special monitoring devices. The aim of this study is to determine whether noninvasive evaluation of respiratory variation of brachial artery peak velocity flow measured using Doppler ultrasound could predict fluid responsiveness in mechanically ventilated patients. METHODS We conducted a prospective clinical research in a 17-bed multidisciplinary ICU and included 38 mechanically ventilated patients for whom fluid administration was planned due to the presence of acute circulatory failure. Volume expansion (VE) was performed with 500 mL of a synthetic colloid. Patients were classified as responders if stroke volume index (SVi) increased >or= 15% after VE. The respiratory variation in Vpeakbrach (DeltaVpeakbrach) was calculated as the difference between maximum and minimum values of Vpeakbrach over a single respiratory cycle, divided by the mean of the two values and expressed as a percentage. Radial arterial pressure variation (DeltaPPrad) and stroke volume variation measured using the FloTrac/Vigileo system (DeltaSVVigileo), were also calculated. RESULTS VE increased SVi by >or= 15% in 19 patients (responders). At baseline, DeltaVpeakbrach, DeltaPPrad and DeltaSVVigileo were significantly higher in responder than nonresponder patients [14 vs 8%; 18 vs. 5%; 13 vs 8%; P < 0.0001, respectively). A DeltaVpeakbrach value >10% predicted fluid responsiveness with a sensitivity of 74% and a specificity of 95%. A DeltaPPrad value >10% and a DeltaSVVigileo >11% predicted volume responsiveness with a sensitivity of 95% and 79%, and a specificity of 95% and 89%, respectively. CONCLUSIONS Respiratory variations in brachial artery peak velocity could be a feasible tool for the noninvasive assessment of fluid responsiveness in patients with mechanical ventilatory support and acute circulatory failure. TRIAL REGISTRATION ClinicalTrials.gov ID: NCT00890071. Journal Article;ClinicalTrials.gov ID: NCT00890071 |
Identificador |
Monge García MI, Gil Cano A, Díaz Monrové JC. Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients. Crit Care.2009 ; 13(5):R142 1466-609X (Online) 1364-8535 (Print) PMC2784351 http://hdl.handle.net/10668/1817 19728876 10.1186/cc8027 |
Idioma(s) |
en |
Publicador |
BioMed Central Ltd |
Relação |
Critical care (London, England) http://ccforum.com/content/13/5/R142/abstract |
Direitos |
Acceso abierto |
Palavras-Chave | #Arteria Braquial #Ecocardiografía Doppler #Velocidad de Flujo Sanguineo #Respiración Artificial #Fluidoterapia #Humanos #España #Medical Subject Headings::Phenomena and Processes::Circulatory and Respiratory Physiological Phenomena::Cardiovascular Physiological Phenomena::Hemodynamics::Hemorheology::Blood Flow Velocity #Medical Subject Headings::Anatomy::Cardiovascular System::Blood Vessels::Arteries::Brachial Artery #Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Techniques, Cardiovascular::Heart Function Tests::Echocardiography::Echocardiography, Doppler #Medical Subject Headings::Check Tags::Female #Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Therapeutics::Drug Therapy::Fluid Therapy #Medical Subject Headings::Organisms::Eukaryota::Animals::Chordata::Vertebrates::Mammals::Primates::Haplorhini::Catarrhini::Hominidae::Humans #Medical Subject Headings::Health Care::Health Care Facilities, Manpower, and Services::Health Facilities::Hospital Units::Intensive Care Units #Medical Subject Headings::Check Tags::Male #Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Diagnosis::Diagnostic Techniques and Procedures::Monitoring, Physiologic #Medical Subject Headings::Health Care::Health Care Quality, Access, and Evaluation::Quality of Health Care::Health Care Evaluation Mechanisms::Epidemiologic Research Design::Sensitivity and Specificity::Predictive Value of Tests #Medical Subject Headings::Health Care::Health Care Quality, Access, and Evaluation::Quality of Health Care::Health Care Evaluation Mechanisms::Epidemiologic Study Characteristics as Topic::Epidemiologic Studies::Cohort Studies::Prospective Studies #Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Therapeutics::Respiratory Therapy::Respiration, Artificial #Medical Subject Headings::Geographicals::Geographic Locations::Europe::Spain #Medical Subject Headings::Phenomena and Processes::Circulatory and Respiratory Physiological Phenomena::Cardiovascular Physiological Phenomena::Hemodynamics::Cardiac Output::Stroke Volume #Medical Subject Headings::Named Groups::Persons::Age Groups::Adult::Aged #Medical Subject Headings::Named Groups::Persons::Age Groups::Adult::Middle Aged |
Tipo |
info:eu-repo/semantics/article info:eu-repo/semantics/published Artículo |