909 resultados para Amperometric measurements
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Amperometric titration using two Pt microelectrodes for the determination of phosphite in fertilizers based on the oxidation of analyte by iodine is proposed. The influence of pH, buffer composition, temperature, and foreign species on the end point and titration time was investigated. For titrations carried out at 70 degrees C using the pH 6.8 phosphate buffer, samples containing ca. 0.4% (m/v) P(2)O(5) could be titrated with 0.050 mol L(-1) iodine titrant, and the end point determined by extrapolating the linear portions of the plot to their intersection coincided with the end point identified by spectrophotometry. Accuracy was checked for phosphite determination in five fertilizer samples. Results were in agreement at the 95% confidence level (paired t test) with spectrophotometry. Recoveries of phosphite added to fertilizer samples ranged from 97% to 102% regardless of the amount of spiking in several determinations. The relative standard deviation (n = 10) was 1.0% for a diluted sample containing 0.050 mol L(-1) Na(2)HPO(3).
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fractional factorial design and factorial with center point design were applied to the development of an amperometric biosensor for the detection of the hepatitis C virus. Biomolecules were immobilized by adsorption on graphite electrodes modified with siloxane-poly(propyleneoxide) hybrid matrix prepared using the sol-gel method. Several parameters were optimized, such as the streptavidin concentration at 0.01 mg mL(-1) and 1.0% bovine serum albumin, the incubation time of the electrodes in the complementary DNA solution for 30 minutes and a 1: 1500 dilution of the avidin-peroxidase conjugate, among others. The application of chemometric studies has been efficient, since the best conditions have been established with a restricted number of experiments, indicating the influence of different factors on the system.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Desenvolveu-se um biossensor para ácido L-ascórbico empregando ascorbato oxidase. A enzima foi extraída do mesocarpo de pepino com solução tampão fosfato 0,05 mol L-1, pH 5,8 contendo NaCl 0,5 mol L-1. Após diálise versus solução tampão fosfato 0,05 mol L-1, pH 5,8 a enzima foi imobilizada em rede de nylon através de ligação covalente com glutaraldeído. A membrana foi acoplada em eletrodo de O2 e a reação monitorada pelo consumo de oxigênio a -600 mV em análise em fluxo (solução tampão fosfato 0,05 mol L-1, pH 5,8 como carregador e vazão 0,5 mL min-1). A curva analítica apresentou-se linear entre 1,2x10-4 a 1,0x10-3 mol L-1. O tempo de vida do biossensor foi de 500 análises. Amostras de medicamentos foram analisadas com a metodologia proposta e os resultados comparados com os obtidos com HPLC.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
De forma geral, os cursos de física clássica oferecidos nas universidades carecem de exemplos de aplicações nas áreas de química e biologia, o que por vezes desmotivam os alunos de graduação destas áreas a estudarem os conceitos físicos desenvolvidos em sala de aula. Neste texto, a analogia entre os osciladores elétrico e mecânico é explorada visando possívies aplicações em química e biologia, mostrando-se de grande valia devido ao seu uso em técnicas de medição de variação de massa com alta precisão, tanto de forma direta como indireta. Estas técnicas são conhecidas como técnicas eletrogravimétricas e são de especial importância em aplicações que envolvem biossensores. Desta forma, o texto explora o estudo da analogia eletromecânica de forma interdisciplinar envolvendo as áreas de física, química e biologia. Baseado nessa analogia é proposto um experimento que permite a sua aplicação em diferentes níveis conceituais dessas disciplinas, tanto em abordagem básica como mais profunda.
Resumo:
A new class of accelerating, exact, explicit and simple solutions of relativistic hydrodynamics is presented. Since these new solutions yield a finite rapidity distribution, they lead to an advanced estimate of the initial energy density and life-time of high energy heavy ion collisions. Accelerating solutions are also given for spherical expansions in arbitrary number of spatial dimensions.
Resumo:
Groups of animals (Wistar rats) were fed with rations doped with uranyl nitrate at concentrations ranging from 0.5 to 100 ppm. The uranium content in the ashes of the organs was measured by the neutron-fission track counting technique. The most striking result is that the transfer coefficients, as a function of the uranium concentration, exhibit a concave shape with a minimum around 20ppm-U for all organs. Explanations to interpret this finding are tentatively given. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
We investigated the IR absorption spectrum of (CH3OH)-C-13 around the frequency of the 10R(20) CO2 laser line. We found two absorption lines which can be excited by 10R(20) and studied the FIR laser emissions excited by this pump line using a waveguide CO2 laser of 300 MHz tunability: We report two new FIR laser lines of large offset, not previously observed due to their weakness and closeness to other stronger lines. We measured the frequencies of five FIR laser lines for the first time by an accurate heterodyne technique and present the complete assignments of the IR-FIR laser systems relative to this pump line. Furthermore we present new frequency values for two FIR laser lines whose frequencies had been previously wrongly measured. Copyright (C) 1997 Elsevier B.V. Ltd.
Resumo:
We report 18 new laser lines from (CH3OH)-C-13 generated in an optically pumped far-infrared laser; the laser lines are in the range of 54.2-420 mu m and are all characterized in wavelength, polarization relative to the pumping CO2 radiation, and pump offset relative to the CO2 center frequency, the frequencies of seven of these new lines along with 10 previously reported lines were measured by an accurate heterodyne technique, mixing them in a metal-insulator-metal (MIM) point contact diode, with another laser line of known frequency.
Resumo:
This work describes an application of a multilayer perceptron neural network technique to correct dome emission effects on longwave atmospheric radiation measurements carried out using an Eppley Precision Infrared Radiometer (PIR) pyrgeometer. It is shown that approximately 7-month-long measurements of dome and case temperatures and meteorological variables available in regular surface stations (global solar radiation, air temperature, and air relative humidity) are enough to train the neural network algorithm and correct the observed longwave radiation for dome temperature effects in surface stations with climates similar to that of the city of São Paulo, Brazil. The network was trained using data from 15 October 2003 to 7 January 2004 and verified using data, not present during the network-training period, from 8 January to 30 April 2004. The longwave radiation values generated by the neural network technique were very similar to the values obtained by Fairall et al., assumed here as the reference approach to correct dome emission effects in PIR pyrgeometers. Compared to the empirical approach the neural network technique is less limited to sensor type and time of day (allows nighttime corrections).