984 resultados para mechanical pre-dewatering
Resumo:
BACKGROUND/AIM: Excitation-contraction coupling is modulated by nitric oxide (NO) which otherwise has either beneficial or detrimental effects on myocardial function during hypoxia-reoxygenation. This work aimed at characterizing the variations of electromechanical delay (EMD) induced by anoxia-reoxygenation within the developing heart and determining whether atrial and ventricular EMD are modulated by NO to the same extent. METHODS: Hearts of 4 or 4.5-day-old chick embryos were excised and submitted in vitro to normoxia (45 min), anoxia (30 min) and reoxygenation (60 min). Electrocardiogram and atrial and ventricular contractions were simultaneously recorded throughout experiment. Anoxia-reoxygenation-induced chrono-, dromo-and inotropic disturbances and changes in EMD in atrium (EMDa) and ventricle (EMDv) were investigated in control hearts and in hearts exposed to 0.1, 1, 10, 50 and 100 microM of DETA-NONOate (a NO donating agent) or to 50 microM of L-NAME (a NOS inhibitor). RESULTS: Under normoxia, heart rate, PR interval, ventricular shortening velocity, EMDa and EMDv were similar in control, L-NAME-treated and DETA-NONOate-treated hearts. Under anoxia, cardiac activity became markedly erratic within less than 10 min in all groups. At the onset of reoxygenation, EMDv was increased by about 300% with respect to the preanoxic value while EMDa did not vary significatively. Compared to control conditions, L-NAME or DETA-NONOate had no influence on the negative chrono-, dromo- and inotropic effects induced by anoxia-reoxygenation. However, L-NAME prolonged EMDv during anoxia and delayed EMDv recovery during reoxygenation while 100 microM DETA-NONOate had the opposite effects. EMDa was neither affected by NOS inhibitor nor NO donor. At the end of reoxygenation, all the investigated parameters returned to their basal values. CONCLUSION: This work provides evidence that a NO-dependent pathway is involved in regulation of the ventricular excitation-contraction coupling in the anoxic-reoxygenated developing heart.
Resumo:
We carried out a cross-section study of the sex-specific relationship between bone mineral content and physical activity at sites with different loading in pre- and early pubertal girls and boys. There was significant sensitivity of bone mineral content of the hip to physical exercise in boys, but not in girls. BACKGROUND: Since little is known whether there are sex differences in sensitivity of bone to loading, we investigated sex differences in the cross-sectional association between measures of physical activity (PA) and bone mass and size in pre- and early pubertal children of both sexes. METHODS: We measured bone mineral content/density (BMC/BMD) and fat-free mass (FFM) in 269 6- to 13-year-old children from randomly selected schools by dual-energy X-ray absorptiometry. Physical activity (PA) was measured by accelerometers and lower extremity strength by a jump-and-reach test. RESULTS: Boys (n = 128) had higher hip and total body BMC and BMD, higher FFM, higher muscle strength and were more physically active than girls (n = 141). Total hip BMC was positively associated with time spent in total and vigorous PA in boys (r = 0.20-0.33, p < 0.01), but not in girls (r = 0.02-0.04, p = ns), even after adjusting for FFM and strength. While boys and girls in the lowest tertile of vigorous PA (22 min/day) did not differ in hip BMC (15.62 vs 15.52 g), boys in the highest tertile (72 min/day) had significantly higher values than the corresponding girls (16.84 vs 15.71 g, p < 0.05). CONCLUSIONS: Sex differences in BMC during pre- and early puberty may be related to a different sensitivity of bone to physical loading, irrespective of muscle mass.
Resumo:
The net mechanical efficiency of positive work (eta(pos)) has been shown to increase if it is immediately preceded by negative work. This phenomenon is explained by the storage of elastic energy during the negative phase and its release during the subsequent positive phase. If a transition time (T) takes place, the elastic energy is dissipated into heat. The aim of the present study was to investigate the relationship between eta(pos) and T, and to determine the minimal T required so that eta(pos) reached its minimal value. Seven healthy male subjects were tested during four series of lowering-raising of the body mass. In the first series (S (0)), the negative and positive phases were executed without any transition time. In the three other series, T was varied by a timer (0.12, 0.24 and 0.56 s for series S (1), S (2) and S (3), respectively). These exercises were performed on a force platform sensitive to vertical forces to measure the mechanical work and a gas analyser was used to determine the energy expenditure. The results indicated that eta(pos) was the highest (31.1%) for the series without any transition time (S (0)). The efficiencies observed with transition times (S (1), S (2) and S (3)) were 27.7, 26.0 and 23.8%, respectively, demonstrating that T plays an important role for mechanical efficiency. The investigation of the relationship between eta(pos) and T revealed that the minimal T required so that eta(pos) reached its minimal value is 0.59 s.
Resumo:
BACKGROUND: Inpatient case fatality from severe malaria remains high in much of sub-Saharan Africa. The majority of these deaths occur within 24 hours of admission, suggesting that pre-hospital management may have an impact on the risk of case fatality. METHODS: Prospective cohort study, including questionnaire about pre-hospital treatment, of all 437 patients admitted with severe febrile illness (presumed to be severe malaria) to the paediatric ward in Sikasso Regional Hospital, Mali, in a two-month period. FINDINGS: The case fatality rate was 17.4%. Coma, hypoglycaemia and respiratory distress at admission were associated with significantly higher mortality. In multiple logistic regression models and in a survival analysis to examine pre-admission risk factors for case fatality, the only consistent and significant risk factor was sex. Girls were twice as likely to die as boys (AOR 2.00, 95% CI 1.08-3.70). There was a wide variety of pre-hospital treatments used, both modern and traditional. None had a consistent impact on the risk of death across different analyses. Reported use of traditional treatments was not associated with post-admission outcome. INTERPRETATION: Aside from well-recognised markers of severity, the main risk factor for death in this study was female sex, but this study cannot determine the reason why. Differences in pre-hospital treatments were not associated with case fatality.
Resumo:
This study of Iowa’s Historic Automobile Roads has been prepared by the Highway Archaeology Program under the terms of an annual cultural resource surveys contract between the Iowa DOT and The University of Iowa. Under this agreement, state transportation funds are appropriated by the Iowa DOT for The University of Iowa Highway Archaeology Program to locate and determine the significance of cultural resources in the area of proposed highway and transportation improvement work. Cultural resources include archaeological, historical, and architectural sites. The study of Iowa’s Historic Automobile Roads reported herein, including archival research and survey, was conducted between June 2002 and June 2007, by Marlin R. Ingalls and Maria F. Schroeder. The University of Iowa Highway Archaeology Program is solely responsible for the content and accuracy of these reports with respect to site location description, interpretation, and recommendations. Duplicate project reports are filed at the State Historic Preservation Office (SHPO), Community Programs Bureau in Des Moines. Illustrations in this report may have been altered for clarity and sized to fit the page.
Resumo:
Vertebroplasty and kyphoplasty have been reported to alter the mechanical behavior of the treated and adjacent-level segments, and have been suggested to increase the risk for adjacent-level fractures. The intervertebral disc (IVD) plays an important role in the mechanical behavior of vertebral motion segments. Comparisons between normal and degenerative IVD motion segments following cement augmentation have yet to be reported. A microstructural finite element model of a degenerative IVD motion segment was constructed from micro-CT images. Microdamage within the vertebral body trabecular structure was used to simulate a slightly (I = 83.5% of intact stiffness), moderately (II = 57.8% of intact stiffness), and severely (III = 16.0% of intact stiffness) damaged motion segment. Six variable geometry single-segment cement repair strategies (models A-F) were studied at each damage level (I-III). IVD and bone stresses, and motion segment stiffness, were compared with the intact and baseline damage models (untreated), as well as, previous findings using normal IVD models with the same repair strategies. Overall, small differences were observed in motion segment stiffness and average stresses between the degenerative and normal disc repair models. We did however observe a reduction in endplate bulge and a redistribution in the microstructural tissue level stresses across both endplates and in the treated segment following early stage IVD degeneration. The cement augmentation strategy placing bone cement along the periphery of the vertebra (model E) proved to be the most advantageous in treating the degenerative IVD models by showing larger reductions in the average bone stresses (vertebral and endplate) as compared to the normal IVD models. Furthermore, only this repair strategy, and the complete cement fill strategy (model F), were able to restore the slightly damaged (I) motion segment stiffness above pre-damaged (intact) levels. Early stage IVD degeneration does not have an appreciable effect in motion segment stiffness and average stresses in the treated and adjacent-level segments following vertebroplasty and kyphoplasty. Placing bone cement in the periphery of the damaged vertebra in a degenerative IVD motion segment, minimizes load transfer, and may reduce the likelihood of adjacent-level fractures.
Resumo:
During thymus development, immature T cells become committed to two distinct lineages based upon expression of alphabeta or gammadelta TCR. In the alphabeta lineage, developing thymocytes progressively extinguish transcription of the TCRgamma genes by a poorly understood process known as gamma silencing. We show that alphabeta lineage thymocytes in mice lacking a functional pre-TCR undergo limited proliferation and fail to silence TCRgamma genes during development. Stimulation of pre-TCR-deficient immature thymocytes with anti-CD3 Abs does not directly down-regulate TCRgamma transcription but restores TCRgamma silencing following proliferation. Collectively our data reveal an important role for pre-TCR induced proliferation in activating the TCRgamma silencer in alphabeta lineage thymocytes, a process that may reinforce alphabeta or gammadelta lineage commitment.
Resumo:
Vastine Pekka Sammallahden artikkeliin Language and roots Congressus internationalis Fenno-Ugristarum (1995): Congressus octavus internationalis Fenno-Ugristarum, Jyväskylä 10.-15.8.1995. - Jyväskylä : Moderatores. ISBN 952-90-6684-8. Pars 1 : Orationes plenariae et conspectus quinquennales, s. 143-153
Resumo:
In dealing with systems as complex as the cytoskeleton, we need organizing principles or, short of that, an empirical framework into which these systems fit. We report here unexpected invariants of cytoskeletal behavior that comprise such an empirical framework. We measured elastic and frictional moduli of a variety of cell types over a wide range of time scales and using a variety of biological interventions. In all instances elastic stresses dominated at frequencies below 300 Hz, increased only weakly with frequency, and followed a power law; no characteristic time scale was evident. Frictional stresses paralleled the elastic behavior at frequencies below 10 Hz but approached a Newtonian viscous behavior at higher frequencies. Surprisingly, all data could be collapsed onto master curves, the existence of which implies that elastic and frictional stresses share a common underlying mechanism. Taken together, these findings define an unanticipated integrative framework for studying protein interactions within the complex microenvironment of the cell body, and appear to set limits on what can be predicted about integrated mechanical behavior of the matrix based solely on cytoskeletal constituents considered in isolation. Moreover, these observations are consistent with the hypothesis that the cytoskeleton of the living cell behaves as a soft glassy material, wherein cytoskeletal proteins modulate cell mechanical properties mainly by changing an effective temperature of the cytoskeletal matrix. If so, then the effective temperature becomes an easily quantified determinant of the ability of the cytoskeleton to deform, flow, and reorganize.
Resumo:
Background: Quality control procedures vary considerably among the providers of equipment for home mechanical ventilation (HMV). Methods: A multicentre quality control survey of HMV was performed at the home of 300 patients included in the HMV programmes of four hospitals in Barcelona. It consisted of three steps: (1) the prescribed ventilation settings, the actual settings in the ventilator control panel, and the actual performance of the ventilator measured at home were compared; (2) the different ventilator alarms were tested; and (3) the effect of differences between the prescribed settings and the actual performance of the ventilator on non-programmed readmissions of the patient was determined. Results: Considerable differences were found between actual, set, and prescribed values of ventilator variables; these differences were similar in volume and pressure preset ventilators. The percentage of patients with a discrepancy between the prescribed and actual measured main ventilator variable (minute ventilation or inspiratory pressure) of more than 20% and 30% was 13% and 4%, respectively. The number of ventilators with built in alarms for power off, disconnection, or obstruction was 225, 280 and 157, respectively. These alarms did not work in two (0.9%), 52 (18.6%) and eight (5.1%) ventilators, respectively. The number of non-programmed hospital readmissions in the year before the study did not correlate with the index of ventilator error. Conclusions: This study illustrates the current limitations of the quality control of HMV and suggests that improvements should be made to ensure adequate ventilator settings and correct ventilator performance and ventilator alarm operation.
Resumo:
The aim of this work was to develop a low-cost circuit for real-time analog computation of the respiratory mechanical impedance in sleep studies. The practical performance of the circuit was tested in six patients with obstructive sleep apnea. The impedance signal provided by the analog circuit was compared with the impedance calculated simultaneously with a conventional computerized system. We concluded that the low-cost analog circuit developed could be a useful tool for facilitating the real-time assessment of airway obstruction in routine sleep studies.