939 resultados para goldfish, colour-blind, motion detection, trainingsexperiments, random dot pattern
Resumo:
Study design: Single-blind randomized, controlled clinical study. Objectives: To evaluate, using kinematic gait analysis, the results obtained from gait training on a treadmill with body weight support versus those obtained with conventional gait training and physiotherapy. Setting: Thirty patients with sequelae from traumatic incomplete spinal cord injuries at least 12 months earlier; patients were able to walk and were classified according to motor function as ASIA (American Spinal Injury Association) impairment scale C or D. Methods: Patients were divided randomly into two groups of 15 patients by the drawing of opaque envelopes: group A (weight support) and group B (conventional). After an initial assessment, both groups underwent 30 sessions of gait training. Sessions occurred twice a week, lasted for 30min each and continued for four months. All of the patients were evaluated by a single blinded examiner using movement analysis to measure angular and linear kinematic gait parameters. Six patients (three from group A and three from group B) were excluded because they attended fewer than 85% of the training sessions. Results: There were no statistically significant differences in intra-group comparisons among the spatial-temporal variables in group B. In group A, the following significant differences in the studied spatial-temporal variables were observed: increases in velocity, distance, cadence, step length, swing phase and gait cycle duration, in addition to a reduction in stance phase. There were also no significant differences in intra-group comparisons among the angular variables in group B. However, group A achieved significant improvements in maximum hip extension and plantar flexion during stance. Conclusion: Gait training with body weight support was more effective than conventional physiotherapy for improving the spatial-temporal and kinematic gait parameters among patients with incomplete spinal cord injuries. Spinal Cord (2011) 49, 1001-1007; doi:10.1038/sc.2011.37; published online 3 May 2011
Resumo:
Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]
Resumo:
We investigated the analgesic effects of unilateral repetitive transcranial magnetic stimulation (rTMS) of the motor cortex (M1) or dorsolateral prefrontal cortex (DLPFC) in two models of experimental pain in healthy volunteers. Two studies were carried out in parallel in two groups of 26 paid healthy volunteers. The effects of active or sham rTMS (frequency, 10 Hz; intensity, 80% resting motor threshold) applied to the right M1 or DLPFC were compared in a double-blind randomized cross-over design. In the first series of experiments, we analyzed the effects of rTMS on thermal (heat and cold) detection and pain thresholds measured on both hands and the left foot, by standardized quantitative sensory testing methods. In the second series of experiments, we measured the effects of M1 or DLPFC rTMS on the threshold and recruitment curves of the RIII nociceptive reflex evoked by ipsilateral electrical stimulation of the sural nerve and recorded on the biceps femoris of both lower limbs. In both studies, measurements were taken before and up to 60 min after the end of rTMS. Active rTMS of both M1 and DLPFC significantly increased the thermal pain thresholds, measured for both hands and the left foot, this effect being most marked for cold pain. These effects, which lasted at least 1 h after rTMS, were selective because they were not associated with changes in non-painful thermal sensations. By contrast, the second study showed that rTMS of M1 or DLPFC had no significant effect on the threshold or recruitment curve of the nociceptive flexion RIII reflex. Our findings demonstrate that unilateral rTMS of M1 or DLPFC induces diffuse and selective analgesic effects in healthy volunteers. The lack of effect on the RIII reflex suggests that such analgesic effects may not depend on the activation of descending inhibitory systems. (C) 2009 International Association for the Study of Pain. Published by Elsevier B. V. All rights reserved.
Resumo:
Background: Verbal fluency (VF) tasks are simple and efficient clinical tools to detect executive dysfunction and lexico-semantic impairment. VF tasks are widely used in patients with suspected dementia, but their accuracy for detection of mild cognitive impairment (MCI) is still under investigation. Schooling in particular may influence the subject`s performance. The aim of this study was to compare the accuracy of two semantic categories (animals and fruits) in discriminating controls, MCI patients and Alzheimer`s disease (AD) patients. Methods: 178 subjects, comprising 70 controls (CG), 70 MCI patients and 38 AD patients, were tested on two semantic VF tasks. The sample was divided into two schooling groups: those with 4-8 years of education and those with 9 or more years. Results: Both VF tasks - animal fluency (VFa) and fruits fluency (VFf) - adequately discriminated CG from AD in the total sample (AUC = 0.88 +/- 0.03, p < 0.0001) and in both education groups, and high educated MCI from AD (VFa: AUC = 0.82 +/- 0.05, p < 0.0001; VFf: AUC = 0.85 +/- 0.05, p < 0.0001). Both tasks were moderately accurate in discriminating CG from MCI (VFa: AUC = 0.68 +/- 0.04, p < 0.0001 - VFf:AUC = 0.73 +/- 0.04, p < 0.0001) regardless of the schooling level, and MCI from AD in the total sample (VFa: AUC = 0.74 +/- 0.05, p < 0.0001; VFf: AUC = 0.76 +/- 0.05, p < 0.0001). Neither of the two tasks differentiated low educated MCI from AD. In the total sample, fruits fluency best discriminated CG from MCI and MCI from AD; a combination of the two improved the discrimination between CG and AD. Conclusions: Both categories were similar in discriminating CG from AD; the combination of both categories improved the accuracy for this distinction. Both tasks were less accurate in discriminating CG from MCI, and MCI from AD.
Resumo:
Aims We conducted a meta-analysis to evaluate the accuracy of quantitative stress myocardial contrast echocardiography (MCE) in coronary artery disease (CAD). Methods and results Database search was performed through January 2008. We included studies evaluating accuracy of quantitative stress MCE for detection of CAD compared with coronary angiography or single-photon emission computed tomography (SPECT) and measuring reserve parameters of A, beta, and A beta. Data from studies were verified and supplemented by the authors of each study. Using random effects meta-analysis, we estimated weighted mean difference (WMD), likelihood ratios (LRs), diagnostic odds ratios (DORs), and summary area under curve (AUC), all with 95% confidence interval (0). Of 1443 studies, 13 including 627 patients (age range, 38-75 years) and comparing MCE with angiography (n = 10), SPECT (n = 1), or both (n = 2) were eligible. WMD (95% CI) were significantly less in CAD group than no-CAD group: 0.12 (0.06-0.18) (P < 0.001), 1.38 (1.28-1.52) (P < 0.001), and 1.47 (1.18-1.76) (P < 0.001) for A, beta, and A beta reserves, respectively. Pooled LRs for positive test were 1.33 (1.13-1.57), 3.76 (2.43-5.80), and 3.64 (2.87-4.78) and LRs for negative test were 0.68 (0.55-0.83), 0.30 (0.24-0.38), and 0.27 (0.22-0.34) for A, beta, and A beta reserves, respectively. Pooled DORs were 2.09 (1.42-3.07), 15.11 (7.90-28.91), and 14.73 (9.61-22.57) and AUCs were 0.637 (0.594-0.677), 0.851 (0.828-0.872), and 0.859 (0.842-0.750) for A, beta, and A beta reserves, respectively. Conclusion Evidence supports the use of quantitative MCE as a non-invasive test for detection of CAD. Standardizing MCE quantification analysis and adherence to reporting standards for diagnostic tests could enhance the quality of evidence in this field.
Resumo:
Background: Little is known about the treatment of depression in older patients with heart failure. This Study was developed to investigate the effectiveness of antidepressant treatment for major depressive disorder (MDD) in the elderly with heart failure. Methods: We enrolled 72 older outpatients with ejection fraction < 50 and diagnosed with MDD by the structured clinical interview for DSM-IV. Thirty-seven patients, 19 on citalopram and 18 on placebo, initiated an 8-week double-blind treatment phase. Measurements were performed with the 31-item Hamilton Rating Scale for Depression (Ham-D-31), the Montgomery-Asberg rating scale (MADRS) and the Systematic Assessment for Treatment Emergent Effects (SAFTEE). A psychiatrist followed up the patients weekly, performing a consultation for about 20 min to field complaints after the measurements. Results: A trend toward superiority of citalopram over placebo in reducing depression was observed in MADRS scores (15.05 + 9.74 vs 9.44 + 9.25, P = .082) but not on HAM-D scores. The depressive symptomatology significantly decreased in both groups (P < .001). The high rate of placebo response during the double-blind phase (56.3%) led us to conclude the study at the interim analysis with 37 patients. Conclusion: Citalopram treatment of MDD in older patients with heart failure is well-tolerated with low rates of side effects, but was not significantly more effective than placebo in the treatment of depression. Weekly psychiatric follow-up including counseling may contribute to the improvement of depression in this population. Scales weighted on psychological symptoms such as the MADRS are possibly better suited to measure depression severity and improvement in patients with heart failure. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Emerging data reveal that oral estrogen therapy can increase clinic blood pressure (BP) in postmenopausal women; however, it is important to establish its effects on ambulatory BP, which is a better predictor for target-organ damage. Besides estrogen therapy, aerobic training is widely recommended for post-menopausal women, and it can decrease ambulatory BP levels. This study was designed to evaluate the effect of aerobic training and estrogen therapy on the ambulatory BP of post-menopausal women. Forty seven healthy hysterectomized women were randomly divided (in a double-blind manner) into 4 groups: placebo-control (PLA-CO = 12), estrogen therapy-control (ET-CO = 14), placebo-aerobic training (PLA-AT = 12), and estrogen therapy-aerobic training (ET-AT = 09). The ET groups received estradiol valerate (1 mg/day) and the AT groups performed cycle ergometer, 3x/week at moderate intensity. Hormonal status (blood analysis), maximal cardiopulmonary exercise test (VO(2) peak) and ambulatory BP (24-h, daytime and nighttime) was evaluated before and 6 months after interventions. A significant increase in VO(2) peak was observed only in women who participated in aerobic training groups (+4.6 +/- 1.0 ml kg(-1) min(-1), P=0.00). Follicle-stimulating hormone was a significant decreased in the ET groups (-18.65 +/- 5.19 pg/ml, P=0.00), and it was accompanied by an increase in circulating estrogen (56.1 +/- 6.6 pg/ml). A significant increase was observed in the ET groups for daytime (P=0.01) and nighttime systolic BP (P=0.01), as well as nighttime diastolic BP (P = 0.02). However, daytime diastolic BP was increased only in the ET-CO group (+3.4 +/- 1.2 mmHg, P=0.04), and did not change in any other groups. No significant effect was found in ambulatory heart rate. In conclusion, aerobic training abolished the increase of daytime ambulatory BP induced by estrogen therapy in hysterectomized, healthy, normotensive and postmenopausal women. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objective: The Purpose of this study was to determine whether handedness influences bilateral shoulder range of motion in nonathlete adult women. Methods: This was an observational Study. Shoulder range of motion (flexion, abduction, horizontal adduction, extension, external and internal rotation) was passively and bilaterally measured in 50 female, right-handed, and healthy university students, ranging from 20 to 29 years of age, who were not practicing repetitive activities with the upper limbs at the time Of this study. The assessment was performed with a universal goniometer, twice for each subject by the same examiner. irst and second measurements were correlated using the intraclass correlation coefficient, which was high for all movements and ranged from 0.80 to 0.97. The Student t test and Wilcoxon test were used to compare the range of motion between the dominant and nondominant shoulders and the mean differences between the 2 sides. The effect of size vias alpha = .05. Results: There is statistically significance difference between the 2 sides when the rotational range of motion is compared the dominant shoulder presented increased external rotation (mean, 4.74 degrees; 95% confidence interval, 1.61-7.87) and decreased internal rotation (mean, 3.52 degrees; 95% confidence interval, 1.64-5.4) compared to the opposite Shoulder. Conclusion: Dominance should be considered when shoulder rotation is evaluated even in nonathlete adult women. (J Manipulative Physiol Ther 2009;32:149-153)
Resumo:
In the present study, our aim was to investigate whether EBV DNA could be found in association with invasive and pre-invasive cervical cancer lesions. We hypothesize that EBV is not merely a commensal agent when present in malignant cervical lesions. DNA was extracted from cervical scrapings followed by nested PCR-based amplification. The patients were 66 women with high grade cervical intraepithelial neoplasia and 14 women with invasive cervical cancer. The control group consisted of 89 women with a normal Pap smear and colposcopy as well as a negative HPV DNA test. Analysis of our results, in conjunction with the work of other authors, leads us to propose that EBV is not merely a commensal agent when present in malignant cervical lesions. The presence of DNA from EBV is significantly associated with cervical cancer.
Resumo:
Objective: To increase dobutamine stress echocardiography feasibility in patients with uncontrolled hypertension, we studied 729 consecutive patients referred for ischemia assessment. Methods: Patients with blood pressure ( BP) levels above 160/ 110 mm Hg were randomized to sublingual placebo or captopril ( 25 mg), and dobutamine stress echocardiography undertaken if BP decreased below 160/ 110 mm Hg after 15 minutes. Results: Of 149 patients ( 20%) with high BP levels, 104 ( 63 +/- 11 years, 51 male) were randomized. Baseline BP levels were similar for captopril ( 178 +/- 15/ 103 +/- 15 mm Hg) and placebo ( 181 +/- 17/ 103 +/- 15 mm Hg) groups. After intervention, 15 patients from captopril and 17 from placebo group had decreased BP ( 11% and 12% for systolic and 13% and 13% for diastolic BP, respectively). Five patients from placebo group ( P =.007) had to prematurely terminate the test because of hypertension ( BP > 220/ 120 mm Hg). Feasibility was similar for captopril and placebo groups ( 35% vs 25%, respectively, P = not significant). Conclusion: Although both captopril and placebo are effective in increasing dobutamine stress echocardiography feasibility in patients with uncontrolled BP, test interruption because of hypertension is less likely to occur after captopril administration.
Resumo:
PURPOSE: To compare the abilities of scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) and variable corneal compensation (VCC) modes for detection of retinal nerve fiber layer (RNFL) loss in eyes with band atrophy (BA) of the optic nerve. DESIGN. Cross-sectional study. METHODS: Thirty-seven eyes from 37 patients with BA and temporal visual field defect from chiasmal compression and 40 eyes from 40 healthy subjects were studied. Subjects underwent standard automated perimetry and RNFL measurements using an SLP device equipped with VCC and ECC. Receiver operating characteristic (ROC) curves were calculated for each parameter. Pearson correlation coefficients were obtained to evaluate the relationship between RNFL thickness parameters and severity of visual field loss, as assessed by the temporal mean defect. RESULTS: All RNFL thickness parameters were significantly lower in eyes with BA compared with normal eyes with both compensation modes. However, no statistically significant differences were observed in the areas under the ROC curves for the different parameters between GDx VCC and ECC (Carl Zeiss Meditec, Inc, Dublin, California, USA). Structure-function relationships also were similar for both compensation modes. CONCLUSIONS: No significant differences were found between the diagnostic accuracy of GDx ECC and that of VCC for detection of BA of the optic nerve. The use of GDx ECC does not seem to provide a better evaluation of RNFL loss on the temporal and nasal sectors of the peripapillary retina in subjects with BA of the optic nerve.
Resumo:
Objective To investigate whether the cox-2 inhibitor celecoxib has antidepressant effects in bipolar disorder (BD) patients during depressive or mixed phases. Methods We studied 28 DSM-IV BD patients who were experiencing a depressive or mixed episode and were on a stable dose of a mood stabilizer or atypical antipsychotic medication. Subjects were randomized to receive 6 weeks of double-blind placebo or celecoxib (400 mg/day) treatment. Current mood stabilizer or antipsychotic medication remained at the same doses during the trial. Results Intention-to-treat analysis showed that the patients receiving celecoxib had lower Hamilton Depression Rating Scale (HamD) scores after 1 week of treatment compared to the patients receiving placebo, but this difference was not statistically significant (p=0.09). The improvement in the first week of treatment was statistically significant when the analysis included only the subjects who completed the full 6-week trial (p=0.03). The two groups did not differ significantly on depressive or manic symptoms from the second week until the end of the trial. Celecoxib was well tolerated with the exception of two subjects who dropped out of the study due to rash. Conclusions Our findings suggest that adjunctive treatment with celecoxib may produce a rapid-onset antidepressant effect in BD patients experiencing depressive or mixed episodes. Copyright (C) 2008 John Wiley & Sons, Ltd.