967 resultados para detectors
Resumo:
The goal of this work has been to calibrate sensitivities and fragmentation pattern of various molecules as well as further characterize the lab model of the ROSINA Double Focusing Mass Spectrometer (DFMS) on board ESA’s Rosetta spacecraft bound to comet 67P/Churyumov-Gerasimenko. The detailed calibration and characterization of the instrument is key to understand and interpret the results in the coma of the comet. A static calibration was performed for the following species: Ne, Ar, Kr, Xe, H2O, N2, CO2, CH4, C2H6, C3H8, C4H10, and C2H4. The purpose of the calibration was to obtain sensitivities for all detectors and emissions, the fragmentation behavior of the ion source and to show the capabilities to measure isotopic ratios at the comet. The calibration included the recording of different correction factors to evaluate the data, including a detailed investigation of the detector gain. The quality of the calibration that could be tested for different gas mixtures including the calibration of the density inside the ion source when calibration gas from the gas calibration unit is introduced. In conclusion the calibration shows that DFMS meets the design requirements and that DFMS will be able to measure the D/H at the comet and help shed more light on the puzzle about the origin of water on Earth.
Resumo:
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
Resumo:
High-energy e(-) and pi(-) were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% +/- 0.5% for electrons in the beam momenta range 17.5-300 MeV/c and 6.0% +/- 1.3% for pions in the beam momenta range 172-345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere inside the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter's magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution. (C) 2015 AIP Publishing LLC.
Resumo:
The transfer coefficient of radon from water to air was investigated in schools. Kitchens, bathrooms and locker rooms were studied for seven schools in Maine. Simulations were done in water-use rooms where radon in air detectors were in place. Quantities measured were radon in water (270-24500 F) and air (0-80 q), volume of water used, emissivities (0.01-0.99) and ventilation rates (0.012-0.066A). Variation throughout the room of the radon concentration was found. Values calculated for the transfer coefficient for kitchens and baths were ranged from 9.6 x to 2.0 x The transfer coefficient was calculated using these parameters and was also measured using concentrations of radon in water and air. This provides a means by which radon in air can be estimated using the transfer coefficient and the concentration in the water in other schools and it can be used to estimate the dose caused by radon released from water use. This project was partially funded by the United States Environmental Protection Agency (grant #X828l2 101-0) and by the State of Maine (grant #10A500178). These are the first measurements of this type to be done in schools in the United States.
Resumo:
The effectiveness of the Anisotropic Analytical Algorithm (AAA) implemented in the Eclipse treatment planning system (TPS) was evaluated using theRadiologicalPhysicsCenteranthropomorphic lung phantom using both flattened and flattening-filter-free high energy beams. Radiation treatment plans were developed following the Radiation Therapy Oncology Group and theRadiologicalPhysicsCenterguidelines for lung treatment using Stereotactic Radiation Body Therapy. The tumor was covered such that at least 95% of Planning Target Volume (PTV) received 100% of the prescribed dose while ensuring that normal tissue constraints were followed as well. Calculated doses were exported from the Eclipse TPS and compared with the experimental data as measured using thermoluminescence detectors (TLD) and radiochromic films that were placed inside the phantom. The results demonstrate that the AAA superposition-convolution algorithm is able to calculate SBRT treatment plans with all clinically used photon beams in the range from 6 MV to 18 MV. The measured dose distribution showed a good agreement with the calculated distribution using clinically acceptable criteria of ±5% dose or 3mm distance to agreement. These results show that in a heterogeneous environment a 3D pencil beam superposition-convolution algorithms with Monte Carlo pre-calculated scatter kernels, such as AAA, are able to reliably calculate dose, accounting for increased lateral scattering due to the loss of electronic equilibrium in low density medium. The data for high energy plans (15 MV and 18 MV) showed very good tumor coverage in contrast to findings by other investigators for less sophisticated dose calculation algorithms, which demonstrated less than expected tumor doses and generally worse tumor coverage for high energy plans compared to 6MV plans. This demonstrates that the modern superposition-convolution AAA algorithm is a significant improvement over previous algorithms and is able to calculate doses accurately for SBRT treatment plans in the highly heterogeneous environment of the thorax for both lower (≤12 MV) and higher (greater than 12 MV) beam energies.
Resumo:
We performed the field-work during the dry (March 2014) and reainy season (May and June 2014) at the species type locality: Cerro Socopó, located at central-west region between Falcón, Lara and Zulia states, Venezuela. Socopó is a small and isolated mountain (1.571 m) belonging to the Ziruma mountains, and represents a relict of tropical mountain forest surrounded by semi-arid vegetation and grassland. This area is home to 312 species of vertebrates, including endangered and endemic amphibians species like Mannophryne lamarcai, Leptodactylus magistris and Dendropsophus amicorum. These forest and species are severely threatened by cattle ranch and illegal timber extraction, with forest formations only above 1000 meters. Despite this, no legal protected figure has been established in the area. We identified a 2.5 km secondary road transect within the study area based on the following criteria: 1) it cover different habitat types (streams and lagoons); and 2) it within the altitudinal gradient described for the specie (1,040 to 1,363 m). We identified three sampling points throughout the transect located in the vicinity of wetland habits: socopo1, socopo2 and socopo4. We did two types of recordings: 1) high quality recordings to characterize the advertisement call for M. lamarcai, non described to date (socopo4), and 2) recordings in different sampling points to evaluate call detectors performance in different acoustic scenarios (in all three localities).
Resumo:
This paper presents a measurement of the charged current interaction rate of the electron neutrino beam component of the beam above 1.5 GeV using the large fiducial mass of the T2K π0 detector. The predominant portion of the νe flux (∼85%) at these energies comes from kaon decays. The measured ratio of the observed beam interaction rate to the predicted rate in the detector with water targets filled is 0.89 ± 0.08 (stat.) ± 0.11 (sys.), and with the water targets emptied is 0.90 ± 0.09 (stat.) ± 0.13 (sys.). The ratio obtained for the interactions on water only from an event subtraction method is 0.87 ± 0.33 (stat.) ± 0.21 (sys.). This is the first measurement of the interaction rate of electron neutrinos on water, which is particularly of interest to experiments with water Cherenkov detectors.
Resumo:
The Tokai to Kamioka (T2K) long-baseline neutrino experiment consists of a muon neutrino beam, produced at the J-PARC accelerator, a near detector complex and a large 295 km distant far detector. The present work utilizes the T2K event timing measurements at the near and far detectors to study neutrino time of flight as function of derived neutrino energy. Under the assumption of a relativistic relation between energy and time of flight, constraints on the neutrino rest mass can be derived. The sub-GeV neutrino beam in conjunction with timing precision of order tens of ns provide sensitivity to neutrino mass in the few MeV/c^2 range. We study the distribution of relative arrival times of muon and electron neutrino candidate events at the T2K far detector as a function of neutrino energy. The 90% C.L. upper limit on the mixture of neutrino mass eigenstates represented in the data sample is found to be m^2 < 5.6 MeV^2/c^4.
Resumo:
Segmented ionization chambers represent a good solution to monitor the position, the intensity and the shape of ion beams in hadrontherapy. Pixel and strip chambers have been developed for both passive scattering and active scanning dose delivery systems. In particular, strip chambers are optimal for pencil beam scanning, allowing for spatial and time resolutions below 0.1 mm and 1 ms, respectively. The MATRIX pixel and the Strip Accurate Monitor for Beam Applications (SAMBA) detectors are described in this paper together with the results of several beam tests and industrial developments based on these prototypes.
Resumo:
A medical cyclotron accelerating H- ions to 18 MeV is in operation at the Bern University Hospital (Inselspital). It is the commercial IBA 18/18 cyclotron equipped with a specifically conceived 6 m long external beam line ending in a separate bunker. This feature is unique for a hospital-based facility and makes it possible to conduct routine radioisotope production for PET diagnostics in parallel with multidisciplinary research activities, among which are novel particle detectors, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. Several of these activities, such as radiobiology experiments for example, require low current beams down to the pA range, while medical cyclotrons are designed for high current operation above 10 μA. In this paper, we present the first results on the low current performance of a PET medical cyclotron obtained by ion source, radio-frequency and main coil tuning. With this method, stable beam currents down to (1.5+/- 0.5 ) pA were obtained and measured with a high-sensitivity Faraday cup located at the end of the beam transport line.
Resumo:
A particle accelerator is any device that, using electromagnetic fields, is able to communicate energy to charged particles (typically electrons or ionized atoms), accelerating and/or energizing them up to the required level for its purpose. The applications of particle accelerators are countless, beginning in a common TV CRT, passing through medical X-ray devices, and ending in large ion colliders utilized to find the smallest details of the matter. Among the other engineering applications, the ion implantation devices to obtain better semiconductors and materials of amazing properties are included. Materials supporting irradiation for future nuclear fusion plants are also benefited from particle accelerators. There are many devices in a particle accelerator required for its correct operation. The most important are the particle sources, the guiding, focalizing and correcting magnets, the radiofrequency accelerating cavities, the fast deflection devices, the beam diagnostic mechanisms and the particle detectors. Most of the fast particle deflection devices have been built historically by using copper coils and ferrite cores which could effectuate a relatively fast magnetic deflection, but needed large voltages and currents to counteract the high coil inductance in a response in the microseconds range. Various beam stability considerations and the new range of energies and sizes of present time accelerators and their rings require new devices featuring an improved wakefield behaviour and faster response (in the nanoseconds range). This can only be achieved by an electromagnetic deflection device based on a transmission line. The electromagnetic deflection device (strip-line kicker) produces a transverse displacement on the particle beam travelling close to the speed of light, in order to extract the particles to another experiment or to inject them into a different accelerator. The deflection is carried out by the means of two short, opposite phase pulses. The diversion of the particles is exerted by the integrated Lorentz force of the electromagnetic field travelling along the kicker. This Thesis deals with a detailed calculation, manufacturing and test methodology for strip-line kicker devices. The methodology is then applied to two real cases which are fully designed, built, tested and finally installed in the CTF3 accelerator facility at CERN (Geneva). Analytical and numerical calculations, both in 2D and 3D, are detailed starting from the basic specifications in order to obtain a conceptual design. Time domain and frequency domain calculations are developed in the process using different FDM and FEM codes. The following concepts among others are analyzed: scattering parameters, resonating high order modes, the wakefields, etc. Several contributions are presented in the calculation process dealing specifically with strip-line kicker devices fed by electromagnetic pulses. Materials and components typically used for the fabrication of these devices are analyzed in the manufacturing section. Mechanical supports and connexions of electrodes are also detailed, presenting some interesting contributions on these concepts. The electromagnetic and vacuum tests are then analyzed. These tests are required to ensure that the manufactured devices fulfil the specifications. Finally, and only from the analytical point of view, the strip-line kickers are studied together with a pulsed power supply based on solid state power switches (MOSFETs). The solid state technology applied to pulsed power supplies is introduced and several circuit topologies are modelled and simulated to obtain fast and good flat-top pulses.
Resumo:
Este trabajo de Tesis ha abordado el objetivo de dar robustez y mejorar la Detección de Actividad de Voz en entornos acústicos adversos con el fin de favorecer el comportamiento de muchas aplicaciones vocales, por ejemplo aplicaciones de telefonía basadas en reconocimiento automático de voz, aplicaciones en sistemas de transcripción automática, aplicaciones en sistemas multicanal, etc. En especial, aunque se han tenido en cuenta todos los tipos de ruido, se muestra especial interés en el estudio de las voces de fondo, principal fuente de error de la mayoría de los Detectores de Actividad en la actualidad. Las tareas llevadas a cabo poseen como punto de partida un Detector de Actividad basado en Modelos Ocultos de Markov, cuyo vector de características contiene dos componentes: la energía normalizada y la variación de la energía. Las aportaciones fundamentales de esta Tesis son las siguientes: 1) ampliación del vector de características de partida dotándole así de información espectral, 2) ajuste de los Modelos Ocultos de Markov al entorno y estudio de diferentes topologías y, finalmente, 3) estudio e inclusión de nuevas características, distintas de las del punto 1, para filtrar los pulsos de pronunciaciones que proceden de las voces de fondo. Los resultados de detección, teniendo en cuenta los tres puntos anteriores, muestran con creces los avances realizados y son significativamente mejores que los resultados obtenidos, bajo las mismas condiciones, con otros detectores de actividad de referencia. This work has been focused on improving the robustness at Voice Activity Detection in adverse acoustic environments in order to enhance the behavior of many vocal applications, for example telephony applications based on automatic speech recognition, automatic transcription applications, multichannel systems applications, and so on. In particular, though all types of noise have taken into account, this research has special interest in the study of pronunciations coming from far-field speakers, the main error source of most activity detectors today. The tasks carried out have, as starting point, a Hidden Markov Models Voice Activity Detector which a feature vector containing two components: normalized energy and delta energy. The key points of this Thesis are the following: 1) feature vector extension providing spectral information, 2) Hidden Markov Models adjustment to environment and study of different Hidden Markov Model topologies and, finally, 3) study and inclusion of new features, different from point 1, to reject the pronunciations coming from far-field speakers. Detection results, taking into account the above three points, show the advantages of using this method and are significantly better than the results obtained under the same conditions by other well-known voice activity detectors.
Resumo:
The engineering design of fissionchambers as on-line radiation detectors for IFMIF is being performed in the framework of the IFMIF-EVEDA works. In this paper the results of the experiments performed in the BR2 reactor during the phase-2 of the foreseen validation activities are addressed. Two detectors have been tested in a mixedneutron-gamma field with high neutron fluence and gamma absorbed dose rates, comparable with the expected values in the HFTM in IFMIF. Since the neutron spectra in all BR2 channels are dominated by the thermal neutron component, the detectors have been surrounded by a cylindrical gadolinium screen to cut the thermal neutron component, in order to get a more representative test for IFMIF conditions. The integrated gamma absorbed dose was about 4 × 1010 Gy and the fast neutron fluence (E > 0.1 MeV) 4 × 1020 n/cm2. The fissionchambers were calibrated in three BR2 channels with different neutron-to-gamma ratio, and the long-term evolution of the signals was studied and compared with theoretical calculations
Resumo:
Molybdenum is a low Tc, type I superconductor whose fundamental properties are poorly known. Its importance as an essential constituent of new high performance radiation detectors, the so-called transition edge sensors (TESs) calls for better characterization of this superconductor, especially in thin film form. Here we report on a study of the basic superconducting features of Mo thin films as a function of their thickness. The resistivity is found to rise and the critical temperature decreases on decreasing film thickness, as expected. More relevant, the critical fields along and perpendicular to the film plane are markedly different, thickness dependent and much larger than the thermodynamic critical field of Mo bulk. These results are consistent with a picture of type II 2D superconducting films, and allow estimates of the fundamental superconducting lengths of Mo. The role of morphology in determining the 2D and type II character of the otherwise type I molybdenum is discussed. The possible consequences of this behaviour on the performance of radiation detectors are also addressed
Resumo:
Gamma detectors based on monolithic scintillator blocks coupled to APDs matrices have proved to be a good alternative to pixelated ones for PET scanners. They provide comparable spatial resolution, improve the sensitivity and make easier the mechanical design of the system. In this study we evaluate by means of Geant4-based simulations the possibility of replacing the APDs by SiPMs. Several commercial matrices of light sensors coupled to LYSO:Ce monolithic blocks have been simulated and compared. Regarding the spatial resolution and linearity of the detector, SiPMs with high photo detection efficiency could become an advantageous replacement for the APDs