Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment


Autoria(s): Aprile, E.; Agostini, F.; Alfonsi, M.; Arazi, L.; Arisaka, K.; Arneodo, F.; Auger, M.; Balan, C.; Barrow, P.; Baudis, L.; Bauermeister, B.; Behrens, A.; Beltrame, P.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, Lukas; Cardoso, J. M. R.; Coderre, Daniel; Colijn, A. P.; Contreras, H.; Cussonneau, J. P.; Decowski, M. P.; Giovanni, A. Di; Duchovni, E.; Fattori, S.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Galloway, M.; Garbini, M.; Geis, C.; Goetzke, L. W.; Grignon, C.; Gross, E.; Hampel, W.; Itay, R.; Kaether, F.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Calloch, M. Le; Lellouch, D.; Levinson, L.; Levy, C.; Lindemann, S.; Lindner, M.; Lopes, J. A. M.; Lyashenko, A.; Macmullin, S.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Mayani, D.; Fernandez, A. J. Melgarejo; Meng, Y.; Messina, M.; Miguez, B.; Molinario, A.; Murra, M.; Naganoma, J.; Oberlack, U.; Orrigo, S. E. A.; Pakarha, P.; Pantic, E.; Persiani, R.; Piastra, F.; Pienaar, J.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; dos Santos, J. M. F.; Sartorelli, G.; Schindler, S.; Schreiner, J.; Schumann, Marc; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Simgen, H.; Teymourian, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Vitells, O.; Wall, R.; Wang, H.; Weber, M.; Weinheimer, C.; Laubenstein, M.
Data(s)

2015

Resumo

The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.

Formato

application/pdf

Identificador

http://boris.unibe.ch/81236/1/art%253A10.1140%252Fepjc%252Fs10052-015-3657-5.pdf

Aprile, E.; Agostini, F.; Alfonsi, M.; Arazi, L.; Arisaka, K.; Arneodo, F.; Auger, M.; Balan, C.; Barrow, P.; Baudis, L.; Bauermeister, B.; Behrens, A.; Beltrame, P.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, Lukas; Cardoso, J. M. R.; ... (2015). Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment. European physical journal. C - particles and fields, 75(11) EDP Sciences 10.1140/epjc/s10052-015-3657-5 <http://dx.doi.org/10.1140/epjc/s10052-015-3657-5>

doi:10.7892/boris.81236

info:doi:10.1140/epjc/s10052-015-3657-5

urn:issn:1434-6044

Idioma(s)

eng

Publicador

EDP Sciences

Relação

http://boris.unibe.ch/81236/

Direitos

info:eu-repo/semantics/openAccess

Fonte

Aprile, E.; Agostini, F.; Alfonsi, M.; Arazi, L.; Arisaka, K.; Arneodo, F.; Auger, M.; Balan, C.; Barrow, P.; Baudis, L.; Bauermeister, B.; Behrens, A.; Beltrame, P.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, Lukas; Cardoso, J. M. R.; ... (2015). Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment. European physical journal. C - particles and fields, 75(11) EDP Sciences 10.1140/epjc/s10052-015-3657-5 <http://dx.doi.org/10.1140/epjc/s10052-015-3657-5>

Palavras-Chave #530 Physics
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed