827 resultados para deep bed filtration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to evaluate the efficiency of the process of biodigestion of the protein concentrate resulting from the ultrafiltration of the effluent from a slaughterhouse freezer of Nile tilapia. Bench digesters were used with excrements and water (control) in comparison with a mixture of cattle manure and effluent from the stages of filleting and bleeding of tilapias. The effluent obtained in the continuous process (bleeding + filleting) was the one with highest accumulated population from the 37th day, as well as greatest daily production. Gases composition did not differ between the protein concentrates, but the gas obtained with the use of the effluent from the filleting stage presented highest methane gas average (78.05%) in comparison with those obtained in the bleeding stage (69.95%) and in the continuous process (70.02%) or by the control method (68.59%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The city of Natal comprises an area of about 170 km² (65,63 squares miles). The Dunas-Barreiras Aquifer is the most important reservoir of the coastal basin of RN. It is being responsible for the water supplying of about 70% of the population, however, due to the sewage disposal system by cesspools and drains, it is presently affected in a great extent by nitrates contamination. Thus, the present work proposes to research the utilization of contaminated water by nitrates of this fountainhead and find cost of the potable water through the ionic exchange technology. This technology consists in the removal of mineral salts by the exchange of cations for one ion of hydrogen (H+), through the passage of water by cationic resin bed and, secondly, by the exchange of the anions for hydroxyl ions (OH-) through a anionic resin bed. The obtained results have showed the waters derived from fountains, big water holes and shallow wells were microbiologically contaminated, while the waters derived from deep wells (above 70 m 76,58 yards) were free of contamination. Thus, only these ones are suitable to the use of ionic technology. The experiments were conducted with the resin IMAC-HP-555 such as kinetic, thermodynamic, and adsorption by fixed bed studies, being obtained several project variables for the experimental column, as follow: work temperature of 25oC; resin maximum capacity maximum e mean of adsorption ==0,01692 g NO3-1/g R e 0,0110 g NO3-1/g R, respectively. On the experimental column were performed breakthrough tests which pointed for an average ideal average speed of work of 13.2 m / h, with an average efficiency of 45% of adsorption, an optimal concentration of NaCl desorption of 8%, and an ideal desorption time of 80 minutes for the equilibrium conditions of water from the Dunas-Barreiras aquifer. Scale projection for ion-exchange column for denitrification, for these variables, using a computer modeling programme, to project the column of ion exchange ROREX-420/2000, obtained a cost for the drinking water denitrified by this system of R$ 0,16 / m3

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A semi solid thin strip continuous casting process was used to obtain 50%wt Pb/50%wtSn strip by single and twin roll processing at speed of 15 m/min. A 50%wt Pb/50%wtSn plate ingot was also cast for rolling conventionally into strips of 1.4 mm thickness and 45 mm width for comparison with those achieved non-conventionally. This hypoeutectic alloy has a solidification interval and fusion temperature of approximately 31 degrees C and 215 degrees C respectively. The casting alloy temperature was around 280 degrees C as measured by a type K immersion thermocouple prior to pouring into a tundish designed to maintain a constant melt flow on the cooling slope during semi solid material production. A nozzle with a weir ensures that the semi solid material is dragged smoothly by the lower roll, producing strip with minimum contamination of slag/oxide. The temperatures of the cooling slope and the lower roll were also monitored using K type thermocouples. The coiled semi solid strip, which has a thickness of 1.5 mm and 45 mm width, was rolled conventionally in order to obtain 1.2 mm thick strip. The coiled thixorolled strip had a thickness of 1.2 mm and achieved practically the same width as the conventional strips. Blanks of 40 mm diameter were cut from the strips in a mechanical press, ready for deep drawing and ironing for mechanical characterization. All the strips achieved from non-conventional processing had the same mechanical performance as those achieved conventionally. The limiting drawing ratio (LDR) achieved was approximately 2.0 for all strips. Microscopy examination was made in order to observe phase segregation during processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hydrodynamic characterization and the performance evaluation of an aerobic three phase fluidized bed reactor in wastewater fish culture treatment are presented in this report. The objective of this study was to evaluate the organic matter, nitrogen and phosphorous removal efficiency in a physical and biological wastewater treatment system of an intensive Nile Tilapia laboratory production with recirculation. The treatment system comprised of a conventional sedimentation basin operated at a hydraulic detention time HDT of 2.94 h and an aerobic three phase airlift fluidized bed reactor AAFBR operated at an 11.9 min HDT. Granular activated carbon was used as support media with density of 1.64 g/cm(3) and effective size of 0.34 mm in an 80 g/L constant concentration. Mean removal efficiencies of BOD, COD, phosphorous, total ammonia nitrogen and total nitrogen were 47%, 77%, 38%, 27% and 24%, respectively. The evaluated system proved an effective alternative for water reuse in the recirculation system capable of maintaining water quality characteristics within the recommended values for fish farming and met the Brazilian standards for final effluent discharges with exception of phosphorous values. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the building of a hydroelectrical power plant at Ilha Solteira in the Parana River (Brazil), materials of a highly weathered soil Oxisol were extracted from a depth between 5 and 8 m for engineering works. This resulted in an abandoned depression area. The topsoil was not salvaged and the open pit was not backfilled, and as result vegetation hardly or not at all recovered. on the residual saprolite materials, an experimental field was established to assess different soil rehabilitation treatments. Field experiments were initiated in 1992. After soil tillage, two different crops and three different liming strategies were compared, giving six combinations. In addition, two uncropped control treatments, tilled and no-tilled, were established so that a total of eight treatments were assessed. The experimental design consisted of four randomized experimental blocks, which included a total of 32 plots with a plot area of 100 m(2). This experiment was used to study the effectiveness of the soil-reclamation treatments after a 9-year period. Soil samples were taken at three different depths (0-10, 10-20, and 20-40 cm), and they were analyzed routinely for pH, organic-matter content, and cation exchange capacity (CEC). Revegetation of the abandoned saprolite material increased soil organic-matter content and cation exchange capacity (CEC), and to some extent small differences between treatments were evidenced. Exchangeable calcium (Ca) and magnesium (Mg) recovered faster than organic-matter content. A significant linear relationship was found between organic-matter content and CEC, suggesting continued addition of organic material will further approach the value of these parameters to those levels corresponding to natural soils under "Cerrado" vegetation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Comparar a eficácia e segurança da profilaxia com heparina de baixo peso molecular (enoxaparina) versus heparina não fracionada (HNF). MÉTODOS: Setenta e cinco pacientes (59 homens e 16 mulheres ), submetidos a amputação maior dos membros inferiores (30 acima do joelho e 45 abaixo do joelho ), foram tratados ao acaso com HNF subcutânea (5,000 IU -2x/dia ) ou enoxaparina subcutânea (40mg/dia ) durante a hospitalização . A profilaxia teve início 12 horas antes da cirurgia ou , em casos emergenciais , no primeiro dia de pós-operatório. RESULTADOS: Os dois grupos de tratamento foram comparáveis em termos de características gerais . A avaliação da TVP foi feita por meio de exame clínico diário e pelo mapeamento dúplex antes e 5-8 dias após a cirurgia . A TVP foi documentada no lado operado em 9,75% dos pacientes tratados com enoxaparina e em 11,76% dos pacientes tratados com HNF (p=0,92) e houve um caso de TVP bilateral em cada grupo . Sangramentos não foram verificados nos 2 grupos . CONCLUSÃO: A enoxaparina e HNF foram igualmente eficientes e seguras para a profilaxia da TVP em pacientes submetidos à amputação de membros inferiores .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Superficial thrombophlebitis (ST) ascending the lower limbs is a common disease, which may be associated with deep vein thrombosis (DVT) and pulmonary embolism (PE). The aim of this study was to investigate the prevalence of DVT and PE as complications of ascending ST of the lower limbs in the great saphenous vein (GSV) or SSV (SSV) and probable risk factors.Methods. For this study 60 consecutive patients were enrolled with ascending ST of the GSV or SSV, seen between 2000 and 2003 at a public hospital in Botucatu, SP, Brazil. All patients were assessed clinically, by venous Duplex scanning of the lower limbs to confirm ST and test for DVT, and by means of pulmonary scintigraphy to test for PE.Results. In 13 ST cases (21.67%) there was concomitant DVT and 17 ST patients (28.33%) also had PE. Eleven patients had a clinical status suggestive of DVT, but only in eight of these (61.5%), this clinical diagnosis was confirmed. Fourteen patients had a clinical status suggestive of PE, and this diagnosis was confirmed in six cases (35.30%). ST patients who also had DVT and/or PE were given anticoagulant treatment with heparin and warfarin. None of the variables studied was predictive of DVT or PE (P>0.05). However, the presence of varicose veins reduced the risk of patients having DVT (relative risk=9.09; 95%CI:1.75 - 50.00 and P=0.023).Conclusion. The prevalence rates of PE (28.3%) and DVT (21.6%) were elevated in this sample of ascending ST cases, indicating a need for detailed assessment of patients for signs of these complications, including for therapeutic management decision making. [Int Angiol 2009;28:400-8]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. This study aimed at assessing the accuracy of ultrasound (US) in the diagnosis of recent deep vein thrombosis (DVT) in an experimental study in dogs.Methods. Design: blinded and randomized experimental study. Twenty dogs were randomly divided in two groups: control group (CG) and thrombosis group (TG). US was performed in the pre- and postoperative period. Phlebography was performed immediately prior to the postoperative US. After the second US, a surgery was performed to detect whether thrombus was present or not. US results were compared to those of phlebography and surgical findings.Results. in all dogs, inferior vena cava (IVC) was compressible. The relations of IVC diameter with the aorta were higher (P<0.005) in TG than in CG. Spectral Doppler in spontaneous breathing, tissue harmonic imaging, power Doppler and B flow showed sensitivity, specificity and accuracy of 1. Phlebography presented sensitivity of 90%, specificity of 80% and accuracy of 85%, when compared to surgical finding.Conclusion. For the diagnosis of recent DVT in the experimental model used, venous compressibility proved to be inefficient. The ratio of WC diameter to aorta, when increased, suggests thrombosis. The use of new US technological advances increases accuracy. Phlebography was less accurate than US.