813 resultados para VISUAL INSPECTION METHODS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To analyze the outcomes of intracorneal ring segment (ICRS) implantation for the treatment of keratoconus based on preoperative visual impairment. DESIGN: Multicenter, retrospective, nonrandomized study. METHODS: A total of 611 eyes of 361 keratoconic patients were evaluated. Subjects were classified according to their preoperative corrected distance visual acuity (CDVA) into 5 different groups: grade I, CDVA of 0.90 or better; grade II, CDVA equal to or better than 0.60 and worse than 0.90; grade III, CDVA equal to or better than 0.40 and worse than 0.60; grade IV, CDVA equal to or better than 0.20 and worse than 0.40; and grade plus, CDVA worse than 0.20. Success and failure indices were defined based on visual, refractive, corneal topographic, and aberrometric data and evaluated in each group 6 months after ICRS implantation. RESULTS: Significant improvement after the procedure was observed regarding uncorrected distance visual acuity in all grades (P < .05). CDVA significantly decreased in grade I (P < .01) but significantly increased in all other grades (P < .05). A total of 37.9% of patients with preoperative CDVA 0.6 or better gained 1 or more lines of CDVA, whereas 82.8% of patients with preoperative CDVA 0.4 or worse gained 1 or more lines of CDVA (P < .01). Spherical equivalent and keratometry readings showed a significant reduction in all grades (P ≤ .02). Corneal higher-order aberrations did not change after the procedure (P ≥ .05). CONCLUSIONS: Based on preoperative visual impairment, ICRS implantation provides significantly better results in patients with a severe form of the disease. A notable loss of CDVA lines can be expected in patients with a milder form of keratoconus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To quantitatively evaluate visual function 12 months after bilateral implantation of the Physiol FineVision® trifocal intraocular lens (IOL) and to compare these results with those obtained in the first postoperative month. METHODS: In this prospective case series, 20 eyes of 10 consecutive patients were included. Monocular and binocular, uncorrected and corrected visual acuities (distance, near, and intermediate) were measured. Metrovision® was used to test contrast sensitivity under static and dynamic conditions, both in photopic and low-mesopic settings. The same software was used for pupillometry and glare evaluation. Motion, achromatic, and chromatic contrast discrimination were tested using 2 innovative psychophysical tests. A complete ophthalmologic examination was performed preoperatively and at 1, 3, 6, and 12 months postoperatively. Psychophysical tests were performed 1 month after surgery and repeated 12 months postoperatively. RESULTS: Final distance uncorrected visual acuity (VA) was 0.00 ± 0.08 and distance corrected VA was 0.00 ± 0.05 logMAR. Distance corrected near VA was 0.00 ± 0.09 and distance corrected intermediate VA was 0.00 ± 0.06 logMAR. Glare testing, pupillometry, contrast sensitivity, motion, and chromatic and achromatic contrast discrimination did not differ significantly between the first and last visit (p>0.05) or when compared to an age-matched control group (p>0.05). CONCLUSIONS: The Physiol FineVision® trifocal IOL provided satisfactory full range of vision and quality of vision parameters 12 months after surgery. Visual acuity and psychophysical tests did not vary significantly between the first and last visit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Esta dissertação apresenta uma arquitectura interoperável que permite lidar com a obtenção, manipulação, processamento e análise de informação geográfica. A aplicação 30, implementada como parte da arquitectura, para além de permitir a visualização e manipulação de dados dentro de um ambiente 30, oferece métodos que permitem descobrir, aceder e usar geo-processos, disponíveis através de serviços Web. A interacção com o utilizador é também feita através uma abordagem que quebra a típica complexidade que a maioria dos Sistemas de Informação Geográfica apresenta. O recurso à programação visual reduz a complexidade do sistema, e permite aos operadores tirar proveito da localização e de uma abstracção de um processo complexo, onde as unidades de processamento são representadas no terreno através de componentes 30 que podem ser directamente manipuladas e ligadas de modo a criar encandeamentos complexos de processos. Estes processos podem também ser criados visualmente e disponibilizados online. ABSTRACT; This thesis presents an interoperable architecture mainly designed for manipulation, processing and geographical information analysis. The three-dimensional interface, implemented as part of the architecture, besides allowing the visualization and manipulation of spatial data within a 30 environment, offers methods for discovering, accessing and using geo-processes, available through Web Services. Furthermore, the user interaction is done through an approach that breaks the typical complexity of most Geographic information Systems. This simplicity is in general archived through a visual programming approach that allows operators to take advantage of location, and use processes through abstract representations. Thus, processing units are represented on the terrain through 30 components, which can be directly manipulated and linked to create complex process chains. New processes can also be visually created and deployed online.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: To compare reading performance in children with and without visual function anomalies and identify the influence of abnormal visual function and other variables in reading ability. Methods: A cross-sectional study was carried in 110 children of school age (6-11 years) with Abnormal Visual Function (AVF) and 562 children with Normal Visual Function (NVF). An orthoptic assessment (visual acuity, ocular alignment, near point of convergence and accommodation, stereopsis and vergences) and autorefraction was carried out. Oral reading was analyzed (list of 34 words). Number of errors, accuracy (percentage of success) and reading speed (words per minute - wpm) were used as reading indicators. Sociodemographic information from parents (n=670) and teachers (n=34) was obtained. Results: Children with AVF had a higher number of errors (AVF=3.00 errors; NVF=1.00 errors; p<0.001), a lower accuracy (AVF=91.18%; NVF=97.06%; p<0.001) and reading speed (AVF=24.71 wpm; NVF=27.39 wpm; p=0.007). Reading speed in the 3rd school grade was not statistically different between the two groups (AVF=31.41 wpm; NVF=32.54 wpm; p=0.113). Children with uncorrected hyperopia (p=0.003) and astigmatism (p=0.019) had worst reading performance. Children in 2nd, 3rd, or 4th grades presented a lower risk of having reading impairment when compared with the 1st grade. Conclusion: Children with AVF had reading impairment in the first school grade. It seems that reading abilities have a wide variation and this disparity lessens in older children. The slow reading characteristics of the children with AVF are similar to dyslexic children, which suggest the need for an eye evaluation before classifying the children as dyslexic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The efficient indirect office work brings competitive advantage for companies in a rapidly changing business environment. The direct work methods in factory floors have been developed already for decades, but the office work is an area where the potential to improve the value add has not been studied and utilized systematically so far. The first objective of the thesis work is to find useful method for identifying and managing value add using literature. The usefulness of the method is validated in the case company`s environment. The second objective of the work is to understand what kind of effort is required to create more efficient target setting for the white collar employees. The operative level targets should be linked more tightly to the company strategy. Lean methods are selected as a tool for the improvement, since they are widely used in all kinds of industries and they are already familiar in other functions in the case company. Based on the literature review, suitable improvement methods are selected. The core of the lean is to identify the value add of a customer and eliminate the waste. Also visual control, cross functional work team, flow office and continuous improvement are used. The methods are tested in one production line and the results and feedback indicate that methods are useful in the studied environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sequences of timestamped events are currently being generated across nearly every domain of data analytics, from e-commerce web logging to electronic health records used by doctors and medical researchers. Every day, this data type is reviewed by humans who apply statistical tests, hoping to learn everything they can about how these processes work, why they break, and how they can be improved upon. To further uncover how these processes work the way they do, researchers often compare two groups, or cohorts, of event sequences to find the differences and similarities between outcomes and processes. With temporal event sequence data, this task is complex because of the variety of ways single events and sequences of events can differ between the two cohorts of records: the structure of the event sequences (e.g., event order, co-occurring events, or frequencies of events), the attributes about the events and records (e.g., gender of a patient), or metrics about the timestamps themselves (e.g., duration of an event). Running statistical tests to cover all these cases and determining which results are significant becomes cumbersome. Current visual analytics tools for comparing groups of event sequences emphasize a purely statistical or purely visual approach for comparison. Visual analytics tools leverage humans' ability to easily see patterns and anomalies that they were not expecting, but is limited by uncertainty in findings. Statistical tools emphasize finding significant differences in the data, but often requires researchers have a concrete question and doesn't facilitate more general exploration of the data. Combining visual analytics tools with statistical methods leverages the benefits of both approaches for quicker and easier insight discovery. Integrating statistics into a visualization tool presents many challenges on the frontend (e.g., displaying the results of many different metrics concisely) and in the backend (e.g., scalability challenges with running various metrics on multi-dimensional data at once). I begin by exploring the problem of comparing cohorts of event sequences and understanding the questions that analysts commonly ask in this task. From there, I demonstrate that combining automated statistics with an interactive user interface amplifies the benefits of both types of tools, thereby enabling analysts to conduct quicker and easier data exploration, hypothesis generation, and insight discovery. The direct contributions of this dissertation are: (1) a taxonomy of metrics for comparing cohorts of temporal event sequences, (2) a statistical framework for exploratory data analysis with a method I refer to as high-volume hypothesis testing (HVHT), (3) a family of visualizations and guidelines for interaction techniques that are useful for understanding and parsing the results, and (4) a user study, five long-term case studies, and five short-term case studies which demonstrate the utility and impact of these methods in various domains: four in the medical domain, one in web log analysis, two in education, and one each in social networks, sports analytics, and security. My dissertation contributes an understanding of how cohorts of temporal event sequences are commonly compared and the difficulties associated with applying and parsing the results of these metrics. It also contributes a set of visualizations, algorithms, and design guidelines for balancing automated statistics with user-driven analysis to guide users to significant, distinguishing features between cohorts. This work opens avenues for future research in comparing two or more groups of temporal event sequences, opening traditional machine learning and data mining techniques to user interaction, and extending the principles found in this dissertation to data types beyond temporal event sequences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese (doutorado)—Universidade de Brasília, Faculdade de Comunicação, Programa de Pós-Graduação em Comunicação, 2016.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In September 2013, staff from the University of the South Pacific (USP) Honiara campus, the Secretariat of the Pacific Community (SPC) and IFREMER (UR LEADNC, AMBIO project) in New Caledonia, and the French Institute for Pacific Coral Reefs (IRCP) in Moorea, French Polynesia, co-facilitated a workshop entitled “Different survey methods of coral reef fish, including the methods based on underwater video”. The workshop was attended by students from USP, NGO and fisheries officers. They were trained to several underwater visual census techniques and to the STAVIRO video-based technique, including both field work and data analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose.: To determine photopic and mesopic distance high-contrast visual acuity (HC-VA) and low-contrast visual acuity (LC-VA) in eyes with early age-related macular degeneration (AMD). Methods.: Measurements were made in 22 subjects with early AMD and 28 healthy control subjects. Inclusion criteria included a photopic HC-VA of 20/25 or better. Distance VA was measured using HC (96%) and LC (10%) Bailey-Lovie logMAR letter charts under photopic (85 cd/m2) and mesopic (0.1–0.2 cd/m2) luminance conditions. Results.: Mean mesopic distance HC-VA and LC-VA were significantly worse (0.1 logMAR and 0.28 logMAR, respectively) in the early AMD group than in the control group. Under mesopic conditions, the mean difference between LC-VA and HC-VA was significantly greater in the early AMD (0.45 logMAR) than the control group (0.27 logMAR). Mean differences between mesopic versus photopic HC-VA and mesopic versus photopic LC-VA were significantly greater in the early AMD than the control group (0.13 and 0.32 logMAR of difference between the means, respectively). Sensitivity and specificity were significantly greater for mesopic LC-VA than for mesopic HC-VA (Receiver Operating Characteristics, area under the curve [AUC], 0.94 ± 0.030 and 0.76 ± 0.067, respectively). AUC values for photopic HC-VA and LC-VA were below 0.70. Conclusions.: Visual acuity testing under low luminance conditions emerged as an optimal quantitative measure of retinal function in early AMD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To investigate the cortical mechanisms that prevent diplopia in intermittent exotropia (X(T)) during binocular alignment (orthotropia). METHODS The authors studied 12 X(T) patients aged 5 to 22 years. Seventy-five percent had functional stereo vision with stereoacuity similar to that of 12 age-matched controls (0.2-3.7 min arc). Identical face images were presented to the two eyes for 400 ms. In one eye, the face was presented at the fovea; in the other, offset along the horizontal axis with up to 12° eccentricity. The task was to indicate whether one or two faces were perceived. RESULTS All X(T) patients showed normal diplopia when the nonfoveal face was presented to nasal hemiretina, though with a slightly larger fusional range than age-matched controls. However, 10 of 12 patients never experienced diplopia when the nonfoveal face was presented to temporal hemiretina (i.e., when the stimulus simulated exodeviation). Patients showed considerable variability when the single image was perceived. Some patients suppressed the temporal stimulus regardless of which eye viewed it, whereas others suppressed a particular eye even when it viewed the foveal stimulus. In two patients, the simulated exodeviation might have triggered a shift from normal to anomalous retinal correspondence. CONCLUSIONS Antidiplopic mechanisms in X(T) can be reliably triggered by purely retinal information during orthotropia, but the nature of these mechanisms varies between patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Des interventions ciblant l’amélioration cognitive sont de plus en plus à l’intérêt dans nombreux domaines, y compris la neuropsychologie. Bien qu'il existe de nombreuses méthodes pour maximiser le potentiel cognitif de quelqu’un, ils sont rarement appuyé par la recherche scientifique. D’abord, ce mémoire examine brièvement l'état des interventions d'amélioration cognitives. Il décrit premièrement les faiblesses observées dans ces pratiques et par conséquent il établit un modèle standard contre lequel on pourrait et devrait évaluer les diverses techniques ciblant l'amélioration cognitive. Une étude de recherche est ensuite présenté qui considère un nouvel outil de l'amélioration cognitive, une tâche d’entrainement perceptivo-cognitive : 3-dimensional multiple object tracking (3D-MOT). Il examine les preuves actuelles pour le 3D-MOT auprès du modèle standard proposé. Les résultats de ce projet démontrent de l’augmentation dans les capacités d’attention, de mémoire de travail visuel et de vitesse de traitement d’information. Cette étude représente la première étape dans la démarche vers l’établissement du 3D-MOT comme un outil d’amélioration cognitive.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background In recent years new models of intraocular lenses are appearing on the market to reduce requirements for additional optical correction. The purpose of this study is to assess visual outcomes following bilateral cataract surgery and the implant of a FineVision® trifocal intraocular lens (IOL). Methods Prospective, nonrandomized, observational study. Vision was assessed in 44 eyes of 22 patients (mean age 68.4 ± 5.5 years) before and 3 months after surgery. Aberrations were determined using the Topcon KR-1 W wave-front analyzer. LogMAR visual acuity was measured at distance (corrected distance visual acuity, CDVA 4 m), intermediate (distance corrected intermediate visual acuity, DCIVA 60 cm) and near (distance corrected near visual acuity, DCNVA 40 cm). The Pelli-Robson letter chart and the CSV-1000 test were used to estimate contrast sensitivity (CS). Defocus curve testing was performed in photopic and mesopic conditions. Adverse photic phenomena were assessed using the Halo v1.0 program. Results Mean aberration values for a mesopic pupil diameter were: total HOA RMS: 0.41 ± 0.30 μm, coma: 0.32 ± 0.22 μm and spherical aberration: 0.21 ± 0.20 μm. Binocular logMAR measurements were: CDVA −0.05 ± 0.05, DCIVA 0.15 ± 0.10, and DCNVA 0.06 ± 0.10. Mean Pelli-Robson CS was 1.40 ± 0.14 log units. Mean CSV100 CS for the 4 frequencies examined (A: 3 cycles/degree (cpd), B: 6 cpd, C: 12 cpd, D: 18 cpd) were 1.64 ± 0.14, 1.77 ± 0.18, 1.44 ± 0.24 and 0.98 ± 0.24 log units, respectively. Significant differences were observed in defocus curves for photopic and mesopic conditions (p < 0.0001). A mean disturbance index of 0.28 ± 0.22 was obtained. Conclusions Bilateral FineVision IOL implant achieved a full range of adequate vision, satisfactory contrast sensitivity, and a lack of significant adverse photic phenomena. Trial registration Eudract Clinical Trials Registry Number: 2014-003266-2.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A evolução do varejo no Brasil, também atribuída ao crescimento econômico das últimas décadas, foi marcada pelo surgimento de novos formatos e estratégias comerciais e por um surpreendente processo de transformação social. Observa-se que a referida transformação social foi seguida pelo aumento do poder aquisitivo das diferentes classes sociais que compõem o cenário econômico. O crescimento econômico, proporcionado pela instituição de políticas econômicas e de inclusão social, fez despontar um nicho de mercado, que até o momento apresentava-se com acesso restrito ao consumo, formado pela classe social de baixa renda. O surgimento de um novo cenário mercadológico constituído por indivíduos pertencentes à classe social de baixa renda e a concorrência saturada dos mercados consolidados despertaram o interesse de muitas empresas em incrementar suas atividades investindo no emergente mercado de consumo. Para consolidar suas atuações em um mercado pouco conhecido, algumas empresas perceberam a necessidade de compatibilizar sua estratégias comerciais e de marketing ao novo perfil e comportamento dos respectivos consumidores. Entretanto, ainda é possível observar que muitas das referidas estratégias são desenvolvidas a partir de mitos acerca das motivações e comportamentos de consumo da classe social de baixa renda e, desta forma, não correspondente ao estilo de vida e formação cultural do referido público alvo. O presente estudo pretende contribuir para o aperfeiçoamento do varejo de baixa renda e, desta forma, apresentar a importância de planejar ações comerciais e de convencimento de consumo coordenadas com estratégias de marketing, notadamente do visual merchandising, adaptadas ao referido público alvo. Para alcançar a proposta deste estudo fez-se necessária a compreensão do estilo de vida do respectivo público alvo através do desenvolvimento de métodos de pesquisa investigativos, para uma análise detalhada e assertiva das respectivas motivações de consumo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Des interventions ciblant l’amélioration cognitive sont de plus en plus à l’intérêt dans nombreux domaines, y compris la neuropsychologie. Bien qu'il existe de nombreuses méthodes pour maximiser le potentiel cognitif de quelqu’un, ils sont rarement appuyé par la recherche scientifique. D’abord, ce mémoire examine brièvement l'état des interventions d'amélioration cognitives. Il décrit premièrement les faiblesses observées dans ces pratiques et par conséquent il établit un modèle standard contre lequel on pourrait et devrait évaluer les diverses techniques ciblant l'amélioration cognitive. Une étude de recherche est ensuite présenté qui considère un nouvel outil de l'amélioration cognitive, une tâche d’entrainement perceptivo-cognitive : 3-dimensional multiple object tracking (3D-MOT). Il examine les preuves actuelles pour le 3D-MOT auprès du modèle standard proposé. Les résultats de ce projet démontrent de l’augmentation dans les capacités d’attention, de mémoire de travail visuel et de vitesse de traitement d’information. Cette étude représente la première étape dans la démarche vers l’établissement du 3D-MOT comme un outil d’amélioration cognitive.