920 resultados para Ultrasound sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Routine intravenous cholangiography using the safer contrast medium, meglumine iotroxate, may be a useful investigation prior to laparoscopic cholecystectomy for the detection of suspected common bile duct stones. We compared this with endoscopic cholangiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concrete structures in marine environments are subjected to cyclic wetting and drying, corrosion of reinforcement due to chloride ingress and biological deterioration. In order to assess the quality of concrete and predict the corrosion activity of reinforcing steel in concrete in this environment, it is essential to monitor the concrete continuously right from the construction phase to the end of service life of the structure. In this paper a novel combination of sensor techniques which are integrated in a sensor probe is used to monitor the quality of cover concrete and corrosion of the reinforcement. The integrated sensor probe was embedded in different concrete samples exposed to an aggressive marine environment at the Hangzhou Bay Bridge in China. The sensor probes were connected to a monitoring station, which enabled the access and control of the data remotely from Belfast, UK. The initial data obtained from the monitoring station reflected the early age properties of the concretes and distinct variations in these properties were observed with different concrete types.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Weathering of stone is one of the major reasons for the damage of stone masonry structures and it takes place due to interlinked chemical, physical and biological processes in stones. The key parameters involved in the deterioration processes are temperature, moisture and salt. It is now known that the sudden variations in temperature and moisture greatly accelerate the weathering process of the building stone fabric. Therefore, in order to monitor these sudden variations an effective and continuous monitoring system is needed. Furthermore, it must consist of robust sensors which are accurate and can survive in the harsh environments experienced in and around masonry structures. Although salt penetration is important for the rate of deterioration of stone masonry structures, the processes involved are much slower than the damage associated with temperature and moisture variations. Therefore, in this paper a novel fibre optic temperature cum relative humidity sensor is described and its applicability in monitoring building stones demonstrated. The performance of the sensor is assessed in an experiment comprising wetting and drying of limestone blocks. The results indicate that the novel fibre optic relative humidity sensor which is tailor made for applications in masonry structures performed well in wetting and drying tests, whilst commercial capacitance based sensors failed to recover during the drying regime for a long period after a wetting regime. That is, the fibre optic sensor has the capability to measure both sorption and de-sorption characteristics of stone blocks. This sensor is used in a test wall in Oxford and the data thus obtained strengthened the laboratory observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the reliability and thus the suitability of optical fibre strain sensors for surface strain measurement in concrete structures was investigated. Two different configurations of optical strain sensors were used each having different mountings making them suitable for different uses in various structures. Due to the very limited time available to install the sensors and take result, commercially packaged sensors were used. In the tests carried out each sensor was mounted onto a concrete beam which was then subjected to a range of known and calibrated loadings. The performance of the optical strain sensors thus evaluated was compared with the results of conventional techniques. This comparison allows for selecting the best performing combination of sensor/mounting, i.e. long-gauge sensor with mounts bolted to threaded rods glued into the concrete for use in future work in a field test where a limited time window was available for installation, testing and post-test demounting. © 2012 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the association between different neonatal ultrasonographic classifications and adolescent cognitive, educational, and behavioral outcomes following very preterm birth. Participants included a group of 120 adolescents who were born very preterm (33 weeks of gestation), subdivided into three groups according to their neonatal cerebral ultrasound (US) classifications: (a) normal (N = 69), (b) periventricular hemorrhage (PVH, N = 37), and (c) PVH with ventricular dilatation (PVH + DIL, N = 14), and 50 controls. The cognitive functions assessed were full-scale IQ, phonological and semantic verbal fluency, and visual-motor integration. Educational outcomes included reading and spelling; behavioral outcomes were assessed with the Rutter Parents' Scale and the Premorbid Adjustment Scale (PAS). Adolescent outcome scores were compared among the four groups. A main effect for group was observed for full-scale IQ, Rutter Parents' Scale total scores, and PAS total scores, after controlling for gestational age, socioeconomic status and gender, with the PVH + DIL group showing the most impaired scores compared to the other groups. The current results demonstrate that routine neonatal ultrasound classifications are associated with later cognitive and behavioral outcome. Neonatal ultrasounds could aid in the identification of subgroups of children who are at increased risk of neurodevelopmental problems. These at risk subgroups could then be referred to appropriate early intervention services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Establish maternal preferences for a third-trimester ultrasound scan in a healthy, low-risk pregnant population.

Design: Cross-sectional study incorporating a discrete choice experiment.

Setting: A large, urban maternity hospital in Northern Ireland.

Participants: One hundred and forty-six women in their second trimester of pregnancy.

Methods: A discrete choice experiment was designed to elicit preferences for four attributes of a third-trimester ultrasound scan: health-care professional conducting the scan, detection rate for abnormal foetal growth, provision of non-medical information, cost. Additional data collected included age, marital status, socio-economic status, obstetric history, pregnancy-specific stress levels, perceived health and whether pregnancy was planned. Analysis was undertaken using a mixed logit model with interaction effects.

Main outcome measures: Women's preferences for, and trade-offs between, the attributes of a hypothetical scan and indirect willingness-to-pay estimates.

Results: Women had significant positive preference for higher rate of detection, lower cost and provision of non-medical information, with no significant value placed on scan operator. Interaction effects revealed subgroups that valued the scan most: women experiencing their first pregnancy, women reporting higher levels of stress, an adverse obstetric history and older women.

Conclusions: Women were able to trade on aspects of care and place relative importance on clinical, non-clinical outcomes and processes of service delivery, thus highlighting the potential of using health utilities in the development of services from a clinical, economic and social perspective. Specifically, maternal preferences exhibited provide valuable information for designing a randomized trial of effectiveness and insight for clinical and policy decision makers to inform woman-centred care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To determine the agreement between observers in estimating the configuration of the human anterior chamber angle (ACA) using ultrasound biomicroscopy (UBM). Methods. Two masked clinicians used UBM images to estimate, in 41 eyes, the configuration of the ACA, especially (1) the position of contact between the peripheral iris and the inside of the eye wall, (2) the angularity of the approach to the ACA, and (3) the curvature of the peripheral iris. Agreement between observers was evaluated by the kappa statistic. Results. Inter-observer agreement in assessing the iris insertion (kappa = 0.79), angular width (Kappa = 0.95), and the peripheral iris curvature (kappa = 0.84) was high. Conclusions. The agreement between observers in evaluating the anterior chamber angle configuration by UBM was excellent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: A peripheral iridotomy (PI) is the treatment of choice for pupillary block. In this study we investigated the effect of enlarging the size of a small PI on the anterior chamber angle in patients with angle closure using ultrasound biomicroscopy (UBM). Patients and Methods: Patients who had been treated with laser peripheral iridotomy for angle closure and were identified to have a small patent PI (<100 µm) with still appositionally closed anterior chamber angle were selected prospectively. The anterior chamber angle was assessed using UBM. The angle opening distance 500 µm from the scleral spur (AOD500) as well as the anterior and posterior chamber depth (ACD and PCD) 1000 µm from the scleral spur was measured. In addition, the ACD/PCD ratio was calculated. Afterwards, the PI was enlarged using an Nd: YAG laser and the UBM measurements were repeated as described above. Results: Six eyes of six patients were examined. After the enlargement of the PI the average AOD500 increased from 109 µm (±36) to 147 µm (±40) (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To evaluate agreement between clinical examination (slit lamp examination and gonioscopy) and ultrasound biomicroscopy (UBM) in characterizing various features of the anterior chamber angle and adjacent structures. Methods. Twenty-eight patients (51 eyes) with open angle glaucoma (14), closed angle glaucoma (4), narrow angle and/or plateau iris (10), who had undergone UBM between March 94 and September 95 were studied. Evaluated parameters included angle width, iris configuration and presence of angle closure. The UBMs were reviewed in a masked fashion. Results. In 87.8% of cases there was agreement (within 10 degrees) between gonioscopic and UBM estimates of angle width. In all cases with greater than 10 degrees difference (12.2%) the angle size estimated by UBM was less than that estimated clinically. Iris configuration was graded identically in 51% of cases; the majority of disagreements (76.1%) occurred in cases graded as "regular" by gonioscopy and as "steep" by UBM. Angle closure was judged to be present more frequently by UBM. Conclusions. UBM and gonioscopy do not necessarily yield identical values for angle width, iris configuration, and presence of angle closure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate by ultrasound biomicroscopy (UBM) the anatomical characteristics and the intraocular pressure (IOP) lowering mechanisms of deep sclerectomy after long-term follow-up. Methods: In all, 22 eyes of 21 consecutive patients who had deep sclerectomy were examined by UBM. Several UBM variables were prospectively evaluated, including the presence and maximum length and height of the intrascleral space, the minimum thickness of residual trabeculo-Descemet membrane (TDM), the presence and type of subconjunctival filtering bleb, and the presence of other possible drainage sites, for example suprachoroidal. Surgical success was considered to be achieved when the IOP was

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Glaucoma in infants has many causes. Evaluation of the anatomy of the anterior segment of eyes with infantile glaucoma may help to determine the pathogenesis of an infant's disease and influence therapeutic decisions. Methods: Eleven eyes of six infants with glaucoma were evaluated with ultrasound biomicroscopy (UBM) to evaluate the anatomic characteristics and relationships of the anterior segment structures. Results: The anterior chamber angle, iris, lens, ciliary body, and posterior chamber angle could be imaged in detail. Elongated and anteriorly placed ciliary processes were noted in all eight eyes with trabeculodysgenesis. There were no apparent anomalies in the trabecular meshwork, or anterior chamber. In three eyes with dense corneal opacities, ultrasound biomicroscopy showed severe anterior segment disorganization and thin central corneas with posterior corneal excavation. Conclusions: Ultrasound biomicroscopy is a useful non-invasive method for evaluating infants with glaucoma in cases with corneal opacities. This information can help in surgical planning for glaucoma management.