Cold-formed steel lipped channel beams (LCB) are used extensively in residential, industrial and commercial buildings as load bearing structural elements. Their shear strengths are considerably reduced when web openings are included for the purpose of locating building services. Past research has shown that the shear capacities of LCBs were reduced by up to 70% due to the inclusion of these web openings. Hence there is a need to improve the shear capacities of LCBs with web openings. A cost effective way of eliminating the detrimental effects of large web openings is to attach suitable stiffeners around the web openings and restore the original shear strength and stiffness of the LCBs. Hence detailed experimental studies were undertaken to investigate the shear behaviour and strength of LCBs with stiffened web openings. Both plate and stud stiffeners with varying sizes and thicknesses were attached to the web elements of LCBs using different screw-fastening arrangements. Simply supported test specimens of LCBs with aspect ratios of 1.0 and 1.5 were loaded at mid-span until failure. Test results showed that the plate stiffeners established using AISI recommendations are inadequate to restore the shear strengths of LCBs with web openings. Hence new stiffener arrangements have been proposed for LCBs based on experimental results. This paper presents the details of this experimental study on the shear strength of lipped channel beams with stiffened web openings, and the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire safety of light gauge cold-formed steel frame (LSF) wall systems is significant to the build-ing design. Gypsum plasterboard is widely used as a fire safety material in the building industry. It contains gypsum (CaSO4.2H2O), Calcium Carbonate (CaCO3) and most importantly free and chemically bound water in its crystal structure. The dehydration of the gypsum and the decomposition of Calcium Carbonate absorb heat, which gives the gypsum plasterboard fire resistant qualities. Recently a new composite panel system was developed, where a thin insulation layer was used externally between two plasterboards to improve the fire performance of LSF walls. In this research, finite element thermal models of both the traditional LSF wall panels with cavity insulation and the new LSF composite wall panels were developed to simulate their thermal behaviour under standard and realistic design fire conditions. Suitable thermal properties of gypsum plaster-board, insulation materials and steel were used. The developed models were then validated by comparing their results with fire test results. This paper presents the details of the developed finite element models of non-load bearing LSF wall panels and the thermal analysis results. It has shown that finite element models can be used to simulate the thermal behaviour of LSF walls with varying configurations of insulations and plasterboards. The results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection. Effects of real fire conditions are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light gauge cold-formed steel frame (LSF) structures are increasingly used in industrial, commercial and residential buildings because of their non-combustibility, dimensional stability, and ease of installation. A floor-ceiling system is an example of its applications. LSF floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire rated floor-ceiling assemblies formed with new materials and construction methodologies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite panel in which an external insulation layer is used between two plasterboards has been developed at QUT to provide a higher fire rating to LSF floors under standard fire conditions. But its increased fire rating could not be determined using the currently available design methods. Research on LSF floor systems under fire conditions is relatively recent and the behaviour of floor joists and other components in the systems is not fully understood. The present design methods thus require the use of expensive fire protection materials to protect them from excessive heat increase during a fire. This leads to uneconomical and conservative designs. Fire rating of these floor systems is provided simply by adding more plasterboard sheets to the steel joists and such an approach is totally inefficient. Hence a detailed fire research study was undertaken into the structural and thermal performance of LSF floor systems including those protected by the new composite panel system using full scale fire tests and extensive numerical studies. Experimental study included both the conventional and the new steel floor-ceiling systems under structural and fire loads using a gas furnace designed to deliver heat in accordance with the standard time- temperature curve in AS 1530.4 (SA, 2005). Fire tests included the behavioural and deflection characteristics of LSF floor joists until failure as well as related time-temperature measurements across the section and along the length of all the specimens. Full scale fire tests have shown that the structural and thermal performance of externally insulated LSF floor system was superior than traditional LSF floors with or without cavity insulation. Therefore this research recommends the use of the new composite panel system for cold-formed LSF floor-ceiling systems. The numerical analyses of LSF floor joists were undertaken using the finite element program ABAQUS based on the measured time-temperature profiles obtained from fire tests under both steady state and transient state conditions. Mechanical properties at elevated temperatures were considered based on the equations proposed by Dolamune Kankanamge and Mahendran (2011). Finite element models were calibrated using the full scale test results and used to further provide a detailed understanding of the structural fire behaviour of the LSF floor-ceiling systems. The models also confirmed the superior performance of the new composite panel system. The validated model was then used in a detailed parametric study. Fire tests and the numerical studies showed that plasterboards provided sufficient lateral restraint to LSF floor joists until their failure. Hence only the section moment capacity of LSF floor joists subjected to local buckling effects was considered in this research. To predict the section moment capacity at elevated temperatures, the effective section modulus of joists at ambient temperature is generally considered adequate. However, this research has shown that it leads to considerable over- estimation of the local buckling capacity of joist subject to non-uniform temperature distributions under fire conditions. Therefore new simplified fire design rules were proposed for LSF floor joist to determine the section moment capacity at elevated temperature based on AS/NZS 4600 (SA, 2005), NAS (AISI, 2007) and Eurocode 3 Part 1.3 (ECS, 2006). The accuracy of the proposed fire design rules was verified with finite element analysis results. A spread sheet based design tool was also developed based on these design rules to predict the failure load ratio versus time, moment capacity versus time and temperature for various LSF floor configurations. Idealised time-temperature profiles of LSF floor joists were developed based on fire test measurements. They were used in the detailed parametric study to fully understand the structural and fire behaviour of LSF floor panels. Simple design rules were also proposed to predict both critical average joist temperatures and failure times (fire rating) of LSF floor systems with various floor configurations and structural parameters under any given load ratio. Findings from this research have led to a comprehensive understanding of the structural and fire behaviour of LSF floor systems including those protected by the new composite panel, and simple design methods. These design rules were proposed within the guidelines of the Australian/New Zealand, American and European cold- formed steel structures standard codes of practice. These may also lead to further improvements to fire resistance through suitable modifications to the current composite panel system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last few decades, electric and electromagnetic fields have achieved important role as stimulator and therapeutic facility in biology and medicine. In particular, low magnitude, low frequency, pulsed electromagnetic field has shown significant positive effect on bone fracture healing and some bone diseases treatment. Nevertheless, to date, little attention has been paid to investigate the possible effect of high frequency, high magnitude pulsed electromagnetic field (pulse power) on functional behaviour and biomechanical properties of bone tissue. Bone is a dynamic, complex organ, which is made of bone materials (consisting of organic components, inorganic mineral and water) known as extracellular matrix, and bone cells (live part). The cells give the bone the capability of self-repairing by adapting itself to its mechanical environment. The specific bone material composite comprising of collagen matrix reinforced with mineral apatite provides the bone with particular biomechanical properties in an anisotropic, inhomogeneous structure. This project hypothesized to investigate the possible effect of pulse power signals on cortical bone characteristics through evaluating the fundamental mechanical properties of bone material. A positive buck-boost converter was applied to generate adjustable high voltage, high frequency pulses up to 500 V and 10 kHz. Bone shows distinctive characteristics in different loading mode. Thus, functional behaviour of bone in response to pulse power excitation were elucidated by using three different conventional mechanical tests applying three-point bending load in elastic region, tensile and compressive loading until failure. Flexural stiffness, tensile and compressive strength, hysteresis and total fracture energy were determined as measure of main bone characteristics. To assess bone structure variation due to pulse power excitation in deeper aspect, a supplementary fractographic study was also conducted using scanning electron micrograph from tensile fracture surfaces. Furthermore, a non-destructive ultrasonic technique was applied for determination and comparison of bone elasticity before and after pulse power stimulation. This method provided the ability to evaluate the stiffness of millimetre-sized bone samples in three orthogonal directions. According to the results of non-destructive bending test, the flexural elasticity of cortical bone samples appeared to remain unchanged due to pulse power excitation. Similar results were observed in the bone stiffness for all three orthogonal directions obtained from ultrasonic technique and in the bone stiffness from the compression test. From tensile tests, no significant changes were found in tensile strength and total strain energy absorption of the bone samples exposed to pulse power compared with those of the control samples. Also, the apparent microstructure of the fracture surfaces of PP-exposed samples (including porosity and microcracks diffusion) showed no significant variation due to pulse power stimulation. Nevertheless, the compressive strength and toughness of millimetre-sized samples appeared to increase when the samples were exposed to 66 hours high power pulsed electromagnetic field through screws with small contact cross-section (increasing the pulsed electric field intensity) compare to the control samples. This can show the different load-bearing characteristics of cortical bone tissue in response to pulse power excitation and effectiveness of this type of stimulation on smaller-sized samples. These overall results may address that although, the pulse power stimulation can influence the arrangement or the quality of the collagen network causing the bone strength and toughness augmentation, it apparently did not affect the mineral phase of the cortical bone material. The results also confirmed that the indirect application of high power pulsed electromagnetic field at 500 V and 10 kHz through capacitive coupling method, was athermal and did not damage the bone tissue construction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pre-participation screening is commonly used to measure and assess potential intrinsic injury risk. The single leg squat is one such clinical screening measure used to assess lumbopelvic stability and associated intrinsic injury risk. With the addition of a decline board, the single leg decline squat (SLDS) has been shown to reduce ankle dorsiflexion restrictions and allowed greater sagittal plane movement of the hip and knee. On this basis, the SLDS has been employed in the Cricket Australia physiotherapy screening protocols as a measure of lumbopelvic control in the place of the more traditional single leg flat squat (SLFS). Previous research has failed to demonstrate which squatting technique allows for a more comprehensive assessment of lumbopelvic stability. Tenuous links are drawn between kinematics and hip strength measures within the literature for the SLS. Formal evaluation of subjective screening methods has also been suggested within the literature. Purpose: This study had several focal points namely 1) to compare the kinematic differences between the two single leg squatting conditions, primarily the five key kinematic variables fundamental to subjectively assess lumbopelvic stability; 2) determine the effect of ankle dorsiflexion range of motion has on squat kinematics in the two squat techniques; 3) examine the association between key kinematics and subjective physiotherapists’ assessment; and finally 4) explore the association between key kinematics and hip strength. Methods: Nineteen (n=19) subjects performed five SLDS and five SLFS on each leg while being filmed by an 8 camera motion analysis system. Four hip strength measures (internal/external rotation and abd/adduction) and ankle dorsiflexion range of motion were measured using a hand held dynamometer and a goniometer respectively on 16 of these subjects. The same 16 participants were subjectively assessed by an experienced physiotherapist for lumbopelvic stability. Paired samples t-tests were performed on the five predetermined kinematic variables to assess the differences between squat conditions. A Bonferroni correction for multiple comparisons was used which adjusted the significance value to p = 0.005 for the paired t-tests. Linear regressions were used to assess the relationship between kinematics, ankle range of motion and hip strength measures. Bivariate correlations between hip strength measures and kinematics and pelvic obliquity were employed to investigate any possible relationships. Results: 1) Significant kinematic differences between squats were observed in dominant (D) and non-dominant (ND) end of range hip external rotation (ND p = <0.001; D p = 0.004) and hip adduction kinematics (ND p = <0.001; D p = <0.001). With the mean angle, only the non-dominant leg observed significant differences in hip adduction (p = 0.001) and hip external rotation (p = <0.001); 2) Significant linear relationships were observed between clinical measures of ankle dorsiflexion and sagittal plane kinematic namely SLFS dominant ankle (p = 0.006; R2 = .429), SLFS non-dominant knee (p = 0.015; R2 = .352) and SLFS non-dominant ankle (p = 0.027; R2 = .305) kinematics. Only the dominant ankle (p = 0.020; R2 = .331) was found to have a relationship with the decline squat. 3) Strength measures had tenuous associations with the subjective assessments of lumbopelvic stability with no significant relationships being observed. 4) For the non-dominant leg, external rotation strength and abduction strength were found to be significantly correlated with hip rotation kinematics (Newtons r = 0.458 p = 0.049; Normalised for bodyweight: r = 0.469; p = 0.043) and pelvic obliquity (normalised for bodyweight: r = 0.498 p = 0.030) respectively for the SLFS only. No significant relationships were observed in the dominant leg for either squat condition. Some elements of the hip strength screening protocols had linear relationships with kinematics of the lower limb, particularly the sagittal plane movements of the knee and ankle. Strength measures had tenuous associations with the subjective assessments of lumbopelvic stability with no significant relationships being observed; Discussion: The key finding of this study illustrated that kinematic differences can occur at the hip without significant kinematic differences at the knee as a result of the introduction of a decline board. Further observations reinforce the role of limited ankle dorsiflexion range of motion on sagittal plane movement of the hip and knee and in turn multiplanar kinematics of the lower limb. The kinematic differences between conditions have clinical implications for screening protocols that employ frontal plane movement of the knee as a guide for femoral adduction and rotation. Subjects who returned stronger hip strength measurements also appeared to squat deeper as characterised by differences in sagittal plane kinematics of the knee and ankle. Despite the aforementioned findings, the relationship between hip strength and lower limb kinematics remains largely tenuous in the assessment of the lumbopelvic stability using the SLS. The association between kinematics and the subjective measures of lumbopelvic stability also remain tenuous between and within SLS screening protocols. More functional measures of hip strength are needed to further investigate these relationships. Conclusion: The type of SLS (flat or decline) should be taken into account when screening for lumbopelvic stability. Changes to lower limb kinematics, especially around the hip and pelvis, were observed with the introduction of a decline board despite no difference in frontal plane knee movements. Differences in passive ankle dorsiflexion range of motion yielded variations in knee and ankle kinematics during a self-selected single leg squatting task. Clinical implications of removing posterior ankle restraints and using the knee as a guide to illustrate changes at the hip may result in inaccurate screening of lumbopelvic stability. The relationship between sagittal plane lower limb kinematics and hip strength may illustrate that self-selected squat depth may presumably be a useful predictor of the lumbopelvic stability. Further research in this area is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold-formed steel stud walls are an important component of Light Steel Framing (LSF) building systems used in commercial, industrial and residential buildings. In the conventional LSF stud wall systems, thin-walled steel studs are protected from fire by placing one or two layers of plasterboard on both sides with or without cavity insulation. However, there is very limited data about the structural and thermal performance of these wall systems while past research showed contradicting results about the benefits of cavity insulation. This research proposed a new LSF stud wall system in which a composite panel made of two plasterboards with insulation between them was used to improve the fire rating of walls. Full scale fire tests were conducted using both conventional steel stud walls with and without the use of cavity insulation and the new composite panel system. Eleven full scale load bearing wall specimens were tested to study the thermal and structural performances of the load bearing wall assemblies under standard fire conditions. These tests showed that the use of cavity insulation led to inferior fire performance of walls while also providing good explanations and supporting test data to overcome the incorrect industry assumptions about cavity insulation. Tests demonstrated that the use of external insulation in a composite panel form enhanced the thermal and structural performances of stud walls and increased their fire resistance rating significantly. This paper presents the details of the full scale fire tests of load-bearing wall assemblies lined with plasterboards and different types of insulation under varying load ratios. Test results including the temperature and deflection profiles of walls measured during the fire tests will be presented along with their failure modes and failure times.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-state insurgent actors are too weak to compel powerful adversaries to their will, so they use violence to coerce. A principal objective is to grow and sustain violent resistance to the point that it either militarily challenges the state, or more commonly, generates unacceptable political costs. To survive, insurgents must shift popular support away from the state and to grow they must secure it. State actor policies and actions perceived as illegitimate and oppressive by the insurgent constituency can generate these shifts. A promising insurgent strategy is to attack states in ways that lead angry publics and leaders to discount the historically established risks and take flawed but popular decisions to use repressive measures. Such decisions may be enabled by a visceral belief in the power of coercion and selective use of examples of where robust measures have indeed suppressed resistance. To avoid such counterproductive behaviours the cases of apparent 'successful repression' must be understood. This thesis tests whether robust state action is correlated with reduced support for insurgents, analyses the causal mechanisms of such shifts and examines whether such reduction is because of compulsion or coercion? The approach is founded on prior research by the RAND Corporation which analysed the 30 insurgencies most recently resolved worldwide to determine factors of counterinsurgent success. This new study first re-analyses their data at a finer resolution with new queries that investigate the relationship between repression and insurgent active support. Having determined that, in general, repression does not correlate with decreased insurgent support, this study then analyses two cases in which the data suggests repression seems likely to be reducing insurgent support: the PKK in Turkey and the insurgency against the Vietnamese-sponsored regime after their ousting of the Khmer Rouge. It applies 'structured-focused' case analysis with questions partly built from the insurgency model of Leites and Wolf, who are associated with the advocacy of US robust means in Vietnam. This is thus a test of 'most difficult' cases using a 'least likely' test model. Nevertheless, the findings refute the deterrence argument of 'iron fist' advocates. Robust approaches may physically prevent effective support of insurgents but they do not coercively deter people from being willing to actively support the insurgency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract. Fire resistance has become an important part in structural design due to the ever increasing loss of properties and lives every year. Conventionally the fire rating of load bearing Light gauge Steel Frame (LSF) walls is determined using standard fire tests based on the time-temperature curve given in ISO 834 [1]. Full scale fire testing based on this standard time-temperature curve originated from the application of wood burning furnaces in the early 1900s and it is questionable whether it truly represents the fuel loads in modern buildings. Hence a detailed fire research study into the performance of LSF walls was undertaken using real design fires based on Eurocode parametric curves [2] and Barnett’s ‘BFD’ curves [3]. This paper presents the development of these real fire curves and the results of full scale experimental study into the structural and fire behaviour of load bearing LSF stud wall systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Outdoor workers are exposed to high levels of ultraviolet radiation (UVR) and may thus be at greater risk to experience UVR-related health effects such as skin cancer, sun burn, and cataracts. A number of intervention trials (n=14) have aimed to improve outdoor workers’ work-related sun protection cognitions and behaviours. Only one study however has reported the use of UV-photography as part of a multi-component intervention. This study was performed in the USA and showed long-term (12 months) improvements in work-related sun protection behaviours. Intervention effects of the other studies have varied greatly, depending on the population studied, intervention applied, and measurement of effect. Previous studies have not assessed whether: - Interventions are similarly effective for workers in stringent and less stringent policy organisations; - Policy effect is translated into workers’ leisure time protection; - Implemented interventions are effective in the long-term; - The facial UV-photograph technique is effective in Australian male outdoor workers without a large additional intervention package, and; - Such interventions will also affect workers’ leisure time sun-related cognitions and behaviours. Therefore, the present Protection of Outdoor Workers from Environmental Radiation [POWER]-study aimed to fill these gaps and had the objectives of: a) assessing outdoor workers’ sun-related cognitions and behaviours at work and during leisure time in stringent and less stringent sun protection policy environments; b) assessing the effect of an appearance-based intervention on workers’ risk perceptions, intentions and behaviours over time; c) assessing whether the intervention was equally effective within the two policy settings; and d) assessing the immediate post-intervention effect. Effectiveness was described in terms of changes in sun-related risk perceptions and intentions (as these factors were shown to be main precursors of behaviour change in many health promotion theories) and behaviour. The study purposefully selected and recruited two organisations with a large outdoor worker contingent in Queensland, Australia within a 40 kilometre radius of Brisbane. The two organisations differed in the stringency of implementation and reinforcement of their organisational sun protection policy. Data were collected from 154 male predominantly Australian born outdoor workers with an average age of 37 years and predominantly medium to fair skin (83%). Sun-related cognitions and behaviours of workers were assessed using self-report questionnaires at baseline and six to twelve months later. Variation in follow-up time was due to a time difference in the recruitment of the two organisations. Participants within each organisation were assigned to an intervention or control group. The intervention group participants received a one-off personalised Skin Cancer Risk Assessment Tool [SCRAT]-letter and a facial UV-photograph with detailed verbal information. This was followed by an immediate post-intervention questionnaire within three months of the start of the study. The control group only received the baseline and follow-up questionnaire. Data were analysed using a variety of techniques including: descriptive analyses, parametric and non-parametric tests, and generalised estimating equations. A 15% proportional difference observed was deemed of clinical significance, with the addition of reported statistical significance (p<0.05) where applicable. Objective 1: Assess and compare the current sun-related risk perceptions, intentions, behaviours, and policy awareness of outdoor workers in stringent and less stringent sun protection policy settings. Workers within the two organisations (stringent n=89 and less stringent n=65) were similar in their knowledge about skin cancer, self efficacy, attitudes, and social norms regarding sun protection at work and during leisure time. Participants were predominantly in favour of sun protection. Results highlighted that compared to workers in a less stringent policy organisation working for an organisation with stringent sun protection policies and practices resulted in more desirable sun protection intentions (less willing to tan p=0.03) ; actual behaviours at work (sufficient use of upper and lower body protection, headgear, and sunglasses (p<0.001 for all comparisons), and greater policy awareness (awareness of repercussions if Personal Protective Equipment (PPE) was not used, p<0.001)). However the effect of the work-related sun protection policy was found not to extend to leisure time sun protection. Objective 2: Compare changes in sun-related risk perceptions, intentions, and behaviours between the intervention and control group. The effect of the intervention was minimal and mainly resulted in a clinically significant reduction in work-related self-perceived risk of developing skin cancer in the intervention compared to the control group (16% and 32% for intervention and control group, respectively estimated their risk higher compared to other outdoor workers: , p=0.11). No other clinical significant effects were observed at 12 months follow-up. Objective 3: Assess whether the intervention was equally effective in the stringent sun protection policy organisation and the less stringent sun protection policy organisation. The appearance-based intervention resulted in a clinically significant improvement in the stringent policy intervention group participants’ intention to protect from the sun at work (workplace*time interaction, p=0.01). In addition to a reduction in their willingness to tan both at work (will tan at baseline: 17% and 61%, p=0.06, at follow-up: 54% and 33%, p=0.07, stringent and less stringent policy intervention group respectively. The workplace*time interaction was significant p<0.001) and during leisure time (will tan at baseline: 42% and 78%, p=0.01, at follow-up: 50% and 63%, p=0.43, stringent and less stringent policy intervention group respectively. The workplace*time interaction was significant p=0.01) over the course of the study compared to the less stringent policy intervention group. However, no changes in actual sun protection behaviours were found. Objective 4: Examine the effect of the intervention on level of alarm and concern regarding the health of the skin as well as sun protection behaviours in both organisations. The immediate post-intervention results showed that the stringent policy organisation participants indicated to be less alarmed (p=0.04) and concerned (p<0.01) about the health of their skin and less likely to show the facial UV-photograph to others (family p=0.03) compared to the less stringent policy participants. A clinically significantly larger proportion of participants from the stringent policy organisation reported they worried more about skin cancer (65%) and skin freckling (43%) compared to those in the less stringent policy organisation (46%,and 23% respectively , after seeing the UV-photograph). In summary the results of this study suggest that the having a stringent work-related sun protection policy was significantly related to for work-time sun protection practices, but did not extend to leisure time sun protection. This could reflect the insufficient level of sun protection found in the general Australian population during leisure time. Alternatively, reactance caused by being restricted in personal decisions through work-time policy could have contributed to lower leisure time sun protection. Finally, other factors could have also contributed to the less than optimal leisure time sun protection behaviours reported, such as unmeasured personal or cultural barriers. All these factors combined may have lead to reduced willingness to take proper preventive action during leisure time exposure. The intervention did not result in any measurable difference between the intervention and control groups in sun protection behaviours in this population, potentially due to the long lag time between the implementation of the intervention and assessment at 12-months follow-up. In addition, high levels of sun protection behaviours were found at baseline (ceiling effect) which left little room for improvement. Further, this study did not assess sunscreen use, which was the predominant behaviour assessed in previous effective appearance-based interventions trials. Additionally, previous trials were mainly conducted in female populations, whilst the POWER-study’s population was all male. The observed immediate post-intervention result could be due to more emphasis being placed on sun protection and risks related to sun exposure in the stringent policy organisation. Therefore participants from the stringent policy organisation could have been more aware of harmful effects of UVR and hence, by knowing that they usually protect adequately, not be as alarmed or concerned as the participants from the less stringent policy organisation. In conclusion, a facial UV-photograph and SCRAT-letter information alone may not achieve large changes in sun-related cognitions and behaviour, especially of assessed 6-12 months after the intervention was implemented and in workers who are already quite well protected. Differences found between workers in the present study appear to be more attributable to organisational policy. However, against a background of organisational policy, this intervention may be a useful addition to sun-related workplace health and safety programs. The study findings have been interpreted while respecting a number of limitations. These have included non-random allocation of participants due to pre-organised allocation of participants to study group in one organisation and difficulty in separating participants from either study group. Due to the transient nature of the outdoor worker population, only 105 of 154 workers available at baseline could be reached for follow-up. (attrition rate=32%). In addition the discrepancy in the time to follow-up assessment between the two organisations was a limitation of the current study. Given the caveats of this research, the following recommendations were made for future research: - Consensus should be reached to define "outdoor worker" in terms of time spent outside at work as well as in the way sun protection behaviours are measured and reported. - Future studies should implement and assess the value of the facial UV-photographs in a wide range of outdoor worker organisations and countries. - More timely and frequent follow-up assessments should be implemented in intervention studies to determine the intervention effect and to identify the best timing of booster sessions to optimise results. - Future research should continue to aim to target outdoor workers’ leisure time cognitions and behaviours and improve these if possible. Overall, policy appears to be an important factor in workers’ compliance with work-time use of sun protection. Given the evidence generated by this research, organisations employing outdoor workers should consider stringent implementation and reinforcement of a sun protection policy. Finally, more research is needed to improve ways to generate desirable behaviour in this population during leisure time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a feasible 3D collision avoidance approach for fixed-wing unmanned aerial vehicles (UAVs). The proposed strategy aims to achieve the desired relative bearing in the horizontal plane and relative elevation in the vertical plane so that the host aircraft is able to avoid collision with the intruder aircraft in 3D. The host aircraft will follow a desired trajectory in the collision avoidance course and resume the pre-arranged trajectory after collision is avoided. The approaching stopping condition is determined for the host aircraft to trigger an evasion maneuver to avoid collision in terms of measured heading. A switching controller is designed to achieve the spatial collision avoidance strategy. Simulation results demonstrate that the proposed approach can effectively avoid spatial collision, making it suitable for integration into flight control systems of UAVs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to identify key factors differentiating between exporters and non-exporters in the Chilean wine industry. Based on survey data collected from 61 wineries, the findings show that the main barriers for non-exporters are the lack of financial resources, limited quantities of stock for market expansion, management’s lack of knowledge and experience, and the high cost of travelling and participating in trade shows. The results also show that managers have educational levels and international experience exceeding those of other comparable New World wineries. Finally, in developing their main international markets, Chilean wineries did not target psychically close markets as identified in previous wine industry studies

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the development and implementation of a self-report risk assessment tool that was developed in an attempt to increase the efficacy of crash prediction within Australian fleet settings. This study forms a part of a broader program of research into work related road safety and identification of driving risk. The first phase of the study involved a series of focus groups being conducted with 217 professional drivers which revealed that the following factors were proposed to influence driving performance: Fatigue, Knowledge of risk, Mood, Impatience and frustration, Speed limits, Experience, Other road users, Passengers, Health, and Culture. The second phase of the study involved piloting the newly developed 38 item Driving Risk Assessment Scale - Work Version (DRAS-WV) with 546 professional drivers. Factor analytic techniques identified a 9 factor solution that was comprised of speeding, aggression, time pressure, distraction, casualness, awareness, maintenance, fatigue and minor damage. Speeding and aggressive driving manoeuvres were identified to be the most frequent aberrant driving behaviours engaged in by the sample. However, a series of logistic regression analyses undertaken to determine the DRAS-WV scale’s ability to predict self-reported crashes revealed limited predictive efficacy e.g., 10% of crashes. This paper outlines proposed reasons for this limited predictive ability of the DRAS-WV as well as provides suggestions regarding the future of research that aims to develop methods to identify “at risk” drivers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gypsum plasterboards are commonly used to protect the light gauge steel-framed walls in buildings from fires. Single or multiple plasterboards can be used for this purpose, whereas recent research has proposed a composite panel with a layer of external insulation between two plasterboards. However, a good understanding of the thermal behaviour of these plasterboard panels under fire conditions is not known. Therefore, 15 small-scale fire tests were conducted on plasterboard panels made of 13 and 16 mm plasterboards and four different types of insulations with varying thickness and density subject to standard fire conditions in AS 1530.4. Fire performance of single and multiple layers of gypsum plasterboards was assessed including the effects of interfaces between adjacent plasterboards. Effects of using external insulations such as glass fibre, rockwool and cellulose fibre were also determined. The thermal performance of composite panels developed from different insulating materials of varying densities and thicknesses was examined and compared. This paper presents the details of the fire tests conducted in this study and their valuable time–temperature data for the tested plasterboard panels. These data can be used for the purpose of developing and validating accurate thermal numerical models of these panels.