999 resultados para Tarifas elétricas


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrical resistive heating (ERH) is a thermal method used to improve oil recovery. It can increase oil rate and oil recovery due to temperature increase caused by electrical current passage through oil zone. ERH has some advantage compared with well-known thermal methods such as continuous steam flood, presenting low-water production. This method can be applied to reservoirs with different characteristics and initial reservoir conditions. Commercial software was used to test several cases using a semi-synthetic homogeneous reservoir with some characteristics as found in northeast Brazilian basins. It was realized a sensitivity analysis of some reservoir parameters, such as: oil zone, aquifer presence, gas cap presence and oil saturation on oil recovery and energy consumption. Then it was tested several cases studying the electrical variables considered more important in the process, such as: voltage, electrical configurations and electrodes positions. Energy optimization by electrodes voltage levels changes and electrical settings modify the intensity and the electrical current distribution in oil zone and, consequently, their influences in reservoir temperature reached at some regions. Results show which reservoir parameters were significant in order to improve oil recovery and energy requirement in for each reservoir. Most significant parameters on oil recovery and electrical energy delivered were oil thickness, presence of aquifer, presence of gas cap, voltage, electrical configuration and electrodes positions. Factors such as: connate water, water salinity and relative permeability to water at irreducible oil saturation had low influence on oil recovery but had some influence in energy requirements. It was possible to optimize energy consumption and oil recovery by electrical variables. Energy requirements can decrease by changing electrodes voltages during the process. This application can be extended to heavy oil reservoirs of high depth, such as offshore fields, where nowadays it is not applicable any conventional thermal process such as steam flooding

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eventually, violations of voltage limits at buses or admissible loadings of transmission lines and/or power transformers may occur by the power system operation. If violations are detected in the supervision process, corrective measures may be carried out in order to eliminate them or to reduce their intensity. Loading restriction is an extreme solution and should only be adopted as the last control action. Previous researches have shown that it is possible to control constraints in electrical systems by changing the network topology, using the technique named Corrective Switching, which requires no additional costs. In previous works, the proposed calculations for verifying the ability of a switching variant in eliminating an overload in a specific branch were based on network reduction or heuristic analysis. The purpose of this work is to develop analytical derivation of linear equations to estimate current changes in a specific branch (due to switching measures) by means of few calculations. For bus-bar coupling, derivations will be based on short-circuit theory and Relief Function methodology. For bus-bar splitting, a Relief Function will be derived based on a technique of equivalent circuit. Although systems of linear equations are used to substantiate deductions, its formal solution for each variant, in real time does not become necessary. A priority list of promising variants is then assigned for final check by an exact load flow calculation and a transient analysis using ATP Alternative Transient Program. At last, results obtained by simulation in networks with different features will be presented

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present work is develop a model to simulate electrical energy networks in transient and stead states, using the software ATP (Alternative Transient Program), able to be a way to join two distinct themes, present in classical methodology planning networks: short circuit analysis and load flow theory. Beyond that, using a tool for relay simulation, this paper intend to use the new developed model to investigate the influence of transient phenomenon in operation of protection relays, and calibrate the enterprise's protections relays. For testing the model, some relays, actually, installed at COSERN were used

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of flexible materials for the development of planar circuits is one of the most desired and studied characteristics, lately, by researchers. This happens because the flexibility of the substrate can provide previously impracticable applications, due to the rigidity of the substrates normally used that makes it difficult to fit into the circuits in irregular surfaces. The constant interest in recent years for more lighter devices, increasingly more compacts, flexible and with low cost, led to a new line of research of great interest from both academic and technological views, that is the study and development of textile substrates that can be applied in the development of planar circuits, for applications in the areas of security, biomedical and telecommunications. This paper proposes the development of planar circuits, such as antennas , frequency selective surfaces (FSS) and planar filters, using textile (cotton ticking, jeans and brim santista) as the dielectric substrate and the Pure Copper Polyester Taffeta Fabric, a textile of pure copper, highly conductive, lightweight and flexible, commercially sold as a conductive material. The electrical characteristics of textiles (electric permittivity and loss tangent) were characterized using the transmission line method (rectangular waveguide) and compared with those found in the literature. The structures were analyzed using commercial software Ansoft Designer and Ansoft HFSS, both from the company Ansys and for comparison we used the Iterative Method of Waves (WCIP). For the purpose of validation were built and measured several prototypes of antennas, planar filters and FSS, being possible to confirm an excellent agreement between simulated and measured results

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents a diagnosis faults system (rotor, stator, and contamination) of three-phase induction motor through equivalent circuit parameters and using techniques patterns recognition. The technology fault diagnostics in engines are evolving and becoming increasingly important in the field of electrical machinery. The neural networks have the ability to classify non-linear relationships between signals through the patterns identification of signals related. It is carried out induction motor´s simulations through the program Matlab R & Simulink R , and produced some faults from modifications in the equivalent circuit parameters. A system is implemented with multiples classifying neural network two neural networks to receive these results and, after well-trained, to accomplish the identification of fault´s pattern

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents the analysis of an antenna of fractal microstrip of Koch with dielectric multilayers and inclinations in the ground plane, whose values of the angles are zero degree (without inclinations), three, seven and twelve degrees. This antenna consists of three dielectric layers arranged vertically on each other, using feeding microstrip line in patch 1, of the first layer, which will feed the remaining patches of the upper layers by electromagnetic coupling. The objective of this work is to analyze the effects caused by increase of the angle of inclination of the ground plane in some antenna parameters such as return loss, resonant frequency, bandwidth and radiation pattern. The presented results demonstrate that with the increase of the inclination angle it is possible to get antennas with characteristics multiband, with bigger bandwidth, and improving the impedance matching for each case analyzed, especially the larger angle

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relevant researches have been growing on electric machine without mancal or bearing and that is generally named bearingless motor or specifically, mancal motor. In this paper it is made an introductory presentation about bearingless motor and its peripherical devices with focus on the design and implementation of sensors and interfaces needed to control rotor radial positioning and rotation of the machine. The signals from the machine are conditioned in analogic inputs of DSP TMS320F2812 and used in the control program. This work has a purpose to elaborate and build a system with sensors and interfaces suitable to the input and output of DSP TMS320F2812 to control a mancal motor, bearing in mind the modularity, simplicity of circuits, low number of power used, good noise imunity and good response frequency over 10 kHz. The system is tested at a modified ordinary induction motor of 3,7 kVA to be used with a bearingless motor with divided coil

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A variação da condutividade elétrica da solução nutritiva altera a absorção de água e nutrientes pelas plantas, interferindo no metabolismo e, consequentemente, na produção das mesmas. Este trabalho, conduzido no período de agosto a outubro de 1999, avaliou o efeito da condutividade elétrica (CE) sobre a produção e desenvolvimento de alface americana de cabeça crespa, cultivar Ryder em hidroponia. As tendências de variação da condutividade elétrica do meio nutritivo, durante o desenvolvimento da alface, foram também avaliadas. Foi utilizado o delineamento inteiramente casualizado com seis repetições e três tratamentos, constituídos pelas condutividade elétricas: CE1= 1,46, CE2= 2,46 e CE3= 4,21 (± 0,24) mS cm-1. O diâmetro e altura da cabeça e peso seco da raiz não foram influenciados pelas condutividades elétricas da solução nutritiva. Os maiores pesos do material fresco e seco foram conseguidos com CE 2,46 (± 0,24) mS cm-1. Todos os tratamentos apresentaram a tendência de diminuição da condutividade elétrica, durante o cultivo da alface verificando-se que a condutividade elétrica teve influência sobre as características de produção da alface americana.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The power system stabilizers are used to suppress low-frequency electromechanical oscillations and improve the synchronous generator stability limits. This master thesis proposes a wavelet-based power system stabilizer, composed of a new methodology for extraction and compensation of electromechanical oscillations in electrical power systems based on the scaling coefficient energy of the maximal overlap discrete wavelet transform in order to reduce the effects of delay and attenuation of conventional power system stabilizers. Moreover, the wavelet coefficient energy is used for electric oscillation detection and triggering the power system stabilizer only in fault situations. The performance of the proposed power system stabilizer was assessed with experimental results and comparison with the conventional power system stabilizer. Furthermore, the effects of the mother wavelet were also evaluated in this work

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Egeria najas é uma espécie aquática submersa nativa da bacia hidrográfica do rio Paraná. Com o represamento das águas do rio para geração de energia elétrica a espécie tem mudado seu comportamento de colonização dos leitos dos rios e ocorrido em grandes maciços dentro da represa de Jupiá e rios afluentes. Essa planta tem causado problemas por obstruir a passagem de água para as turbinas de geração de energia elétrica. Coletas de material vegetativo foram realizadas na represa e afluentes do rio Paraná para análise da variabilidade isoenzimática e de DNA. A análise isoenzimática mostrou haver somente quatro classes de diferentes biotipos. No entanto, utilizando-se os procedimentos de RAPD, observou-se que a espécie possui grande variabilidade genética. O represamento das águas também está permitindo o acumulo de variabilidade no local e promovendo um aumento de variabilidade por meio de possíveis cruzamentos entre genótipos diferentes. Os resultados também possibilitaram inferir sobre as possíveis rotas de migração de material genético para colonização da represa e rios afluentes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A gérbera de vaso é uma planta ornamental conhecida mundialmente; entretanto, dispõem-se de reduzido volume de informações sobre suas técnicas de cultivo, em especial a nutrição e adubação, fatores essenciais para ganhos na qualidade produtiva. O presente trabalho teve por objetivo avaliar o teor e o acúmulo de macronutrientes em quatro cultivares de gérbera sob dois níveis de fertirrigação. O experimento foi conduzido em casa de vegetação, de maio a julho de 2006, na UNESP em Botucatu. O mesmo foi instalado em blocos casualizados e constituído de um fatorial 4x2, sendo 4 cultivares de gérbera (Cherry, Golden Yellow, Salmon Rose e Orange) e 2 concentrações de solução nutritiva (50% e 100%), correspondendo respectivamente às condutividades elétricas de 0,92 e 1,76 dS m-1, no período vegetativo e 1,07 e 2,04 dS m-1, no reprodutivo. Os nutrientes foram aplicados via fertirrigação, realizada manualmente, uma vez ao dia. Ao final dos períodos vegetativo e reprodutivo foram quantificados no tecido vegetal, os teores e os acúmulos dos macronutrientes. As demandas destes nutrientes foram diferenciadas entre as cultivares e a concentração da solução apresentou um efeito marcante no teor e acúmulo de N, P, Ca, Mg e S na planta. Os maiores acúmulos foram registrados no terço final do ciclo de produção, apresentando a seguinte ordem de absorção: K>N>Ca>Mg>P>S (415, 327, 33, 32, 20 mg planta-1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Naphthenic lubricating oils are used in transformers with the purpose of promoting electrical insulation and dissipating heat. The working temperature range of these oils typically lies between 60°C and 90°C and their useful life is 40 years in average. In that temperature range, the oils are decomposed during operation, whereby a small fraction of polar compounds are formed. The presence of these compounds may induce failure and loss of physical, chemical and electrical properties of the oil, thus impairing the transformer operation. By removing these contaminants, one allows the oxidized insulating oil to be reused without damaging the equipment. In view of this, an investigation on the use of surfactants and microemulsions as extracting agents, and modified diatomite as adsorbent, has been proprosed in this work aiming to remove polar substances detected in oxidized transformer oils. The extraction was carried out by a simple-contact technique at room temperature. The system under examination was stirred for about 10 minutes, after which it was allowed to settle at 25°C until complete phase separation. In another experimental approach, adsorption equilibrium data were obtained by using a batch system operating at temperatures of 60, 80 and 100°C. Analytical techniques involving determination of the Total Acidity Number (TAN) and infrared spectrophotometry have been employed when monitoring the decomposition and recovery processes of the oils. The acquired results indicated that the microemulsion extraction system comprising Triton® X114 as surfactant proved to be more effective in removing polar compounds, with a decrease in TAN index from 0.19 to 0.01 mg KOH/g, which is consistent with the limits established for new transformer oils (maximal TAN = 0.03 mg KOH/g). In the adsorption studies, the best adsorption capacity values were as high as 0.1606 meq.g/g during conventional adsoprtion procedures using natural bauxite, and as high as 0.016 meq.g/g for the system diatomite/Tensiofix® 8426. Comparatively in this case, a negative effect could be observed on the adsorption phenomenon due to microemulsion impregnation on the surface of the diatomite