961 resultados para Radial Artery
Resumo:
Heparin is the most frequently used drug for the prevention and treatment of thrombosis. Its use, however, is restricted by its side-effects. To study the efficacy of other glycosaminoglycans that could substitute heparin in the management of arterial thrombosis, 60 guinea-pigs were randomly allocated into 6 groups: G1= control, G2= heparin (150 IU/kg), G3= heparan sulfate from beef pancreas (2.5 mg/kg), G4= heparan sulfate from beef lung (2.5 mg/kg), G5= N-acetylated heparan from beef pancreas, G6= dermatan sulfate from beef intestine (2.5 mg/kg). Ten minutes after intravenous injection of the drugs, thrombosis was induced by the injection of a 50% glucose solution into a segment of the right carotid artery isolated between 2 thread loops during 10 minutes. Three hours later the artery was re-exposed and if a thrombus was present it was measured, withdrawn and weighed. Thrombin time and activated partial thromboplastin time were measured in all animals. Thrombus developed in 90% of the animals in the control group, 0% in G2 and G3, 62.5% in G4, 87.5% in G5 and G6. Only in the animals treated with heparin the coagulation tests were prolonged. In conclusion, in the used dose only the heparan sulfate from beef pancreas presented an antithrombotic effect similar to heparin in this experimental model.
Resumo:
This study was designed to analyze the impact of diminished renal perfusion pressure due to renal clipping on the rat model of adriamycin nephropathy. Male Wistar rats, divided into four groups (n = 9 per group) were injected with saline as control (C), adriamycin 3 ml/kg (Ad), saline with the left renal artery clipped (Rv), and adriamycin plus clip (AdRv). After 24 weeks mean arterial pressure (MAP), inulin, and p-aminohippurate (PAH) clearances were performed to evaluate renal function. Morphologic analysis included histologic criteria of percentage of glomerulosclerosis and tubulointerstitial lesion index (TILI). The MAP (mm Hg) was similar between Rv (143 +/- 13) and AdRv (154 +/- 20), but higher (P < .05) than C (120 +/- 8) and Ad (124 +/- 11). Inulin clearance (mL/min/100 g) in Ad (0.2 +/- 0.05) was smaller than in C (0.53 +/- 0.17) and Rv (0.4 +/- 0.01) (P < .05), and was at an intermediate level in AdRv (0.33 +/- 0.2). The level of PAH (mL/min/100 g) was normal at 1.76 in C, and diminished more in Ad (0.58) than in Rv (1.06) and AdRv (1.18) (P < .05). Both Ad and the AdRv nonclipped kidneys had the highest degree of glomerulosclerosis (33% and 25%) and TILI (7% and 8%), respectively, compared with C and Rv (both 0%), whereas the clipped kidneys displayed intermediate degrees (9% and 5%) (P < .05 v nonclipped). The data suggest that diminished perfusion pressure of the clipped kidney, by decreasing the intraglomerular pressure, protects the glomerulus from damage and attenuates the evolution of adriamycin nephropathy. Am J Hypertens 1998;11:1124-1128 (C) 1998 American Journal of Hypertension, Ltd.
Resumo:
Atherosclerotic renal artery stenosis (RAS) and coronary artery disease (CAD) arise from the same multiple risk factors. The purpose of this study was to assess the frequency of previously undiagnosed CAD in patients with angiographically confirmed RAS, by conducting coronary arteriography in the same setting. of 57 consecutive patients referred for renal arteriography on clinical grounds during a 14-month period, 28 had no RAS and 6 had RAS, but previously documented CAD. of the remainder 23 patients. 17 (74%; CI 56%-92%) had both RAS and CAD (7 single vessel, 4 two-vessel, and 7 multivessel disease). The clinical characteristics, such as age, blood pressure (BP) levels, signs of heart failure, were no different between those with and without CAD, although the 4 diabetic patients, the 4 patients with fundoscopic findings of grade III retinopathy, 11 of 14 with peripheral arterial disease, and 7 of 8 patients with prior stroke belonged in the CAD group. None developed complications as a result of the two consecutive procedures. The data suggest that in patients with RAS the frequency of silent CAD is high and cannot be predicted on clinical grounds alone, therefore coronary angiography should be routinely recommended in the same setting.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A case of iatrogenic fistula from the right internal mammary artery to the subclavian vein following subclavian vein catheterization is reported. The patient had undergone percutaneous Intracath catheterization of the subclavian vein to treat hypovolemic shock during the surgical treatment of ectopic pregnancy. She had remained symptom-free for 7 years and then started to complain of effort dyspnea. The patient was found to have a thrill and a bruit at the subclavian region, and arteriography demonstrated a fistula between the right internal mammary artery and the subclavian vein. The fistula was successfully closed by embolization with a percutaneous detachable balloon catheter. © 1993.
Resumo:
Extensive field testes were conducted using the UCD single wheel tester employing three large radial ply tractor tires in two different soils, four different soil conditions, two axle load levels, and three levels of tire inflation pressures in order to quantify the benefits of using low/correct inflation pressures. During these tests slip, net traction, gross traction, and dynamic axle load were recorded. Furthermore, soil moisture content, cone index, and dry bulk density data were obtained at test locations. The results of the analysis showed a significant increase in net traction and traction efficiency when low/correct inflation was used. Benefits of using low/correct pressure was higher in tilled soil conditions.
Resumo:
Unsteady flow of oil and refrigerant gas through radial clearance in rolling piston compressors has been modeled as a heterogeneous mixture, where the properties are determined from the species conservation transport equation coupled with momentum and energy equations. Time variations of pressure, tangential velocity of the rolling piston and radial clearance due to pump setting have been included in the mixture flow model. Those variables have been obtained by modeling the compression process, rolling piston dynamics and by using geometric characteristics of the pump, respectively. An important conclusion concerning this work is the large variation of refrigerant concentration in the oil-filled radial clearance during the compression cycle. That is particularly true for large values of mass flow rates, and for those cases the flow mixture cannot be considered as having uniform concentration. In presence of low mass flow rates homogeneous flow prevail and the mixture tend to have a uniform concentration. In general, it was observed that for calculating the refrigerant mass flow rate using the difference in refrigerant concentration between compression and suction chambers, a time average value for the gas concentration should be used at the clearance inlet.
Resumo:
This paper describes a analog implementation of radial basis neural networks (RBNN) in BiCMOS technology. The RBNN uses a gaussian function obtained through the characteristic of the bipolar differential pair. The gaussian parameters (gain, center and width) is changed with programmable current source. Results obtained with PSPICE software is showed.
Resumo:
The main objective involved with this paper consists of presenting the results obtained from the application of artificial neural networks and statistical tools in the automatic identification and classification process of faults in electric power distribution systems. The developed techniques to treat the proposed problem have used, in an integrated way, several approaches that can contribute to the successful detection process of faults, aiming that it is carried out in a reliable and safe way. The compilations of the results obtained from practical experiments accomplished in a pilot radial distribution feeder have demonstrated that the developed techniques provide accurate results, identifying and classifying efficiently the several occurrences of faults observed in the feeder.
Resumo:
The capacitor placement problem for radial distribution networks aims to determine capacitor types, sizes, locations and control scheme. This is a combinatorial problem that can be formulated as a mixed integer nonlinear program. The paper presents an algorithm inspired in artificial immune systems and developed for this specific problem. A good performance was obtained through experimental tests applied to known systems. © 2006 IEEE.
Resumo:
The aim of this work was to evaluate the effect of physical preconditioning in the responsiveness of rat pulmonary rings submitted to lung ischemia/reperfusion (IR). Wistar rats were divided into three groups: Sedentary sham-operated (SD/SHAM); sedentary submitted to ischemia/reperfusion (SD/IR) and trained submitted to ischemia/reperfusion (TR/IR) animals. Exercise training consisted in sessions of 60 min/day running sessions, 5 days/week for 8 weeks. Left pulmonary IR was performed by occluding for 90 min and reperfusing for 120 min. After that, pulmonary arteries were isolated and concentration-response curves to acetylcholine (ACh), histamine (HIST), sodium nitroprusside (SNP), phenylephrine and U46619 were obtained. Neither potency (- log EC50) nor maximal responses (Emax) were modified for ACh and HIST in all groups. On the other hand, the potency for SNP was significantly increased in TR/IR group (8.23 ± 0.06) compared to SD/IR group (7.85 ± 0.04). Contractile responses mediated by a-adrenergic receptor were markedly decreased in IR groups (SD/IR: 6.75 ± 0.06 and TR/IR: 6.62 ± 0.04) compared to SD/SHAM (7.33 ± 0.05). No changes were seen for the U46619 in all groups. In conclusion, the present study shows that exercise training has no protective actions in the local blood vessel where the IR process takes place. © 2006 Elsevier Inc. All rights reserved.
Resumo:
An analog circuit that implements a radial basis function network is presented. The proposed circuit allows the adjustment of all shape parameters of the radial functions, i.e., amplitude, center and width. The implemented network was applied to the linearization of a nonlinear circuit, a voltage controlled oscillator (VCO). This application can be classified as an open-loop control in which the network plays the role of the controller. Experimental results have proved the linearization capability of the proposed circuit. Its performance can be improved by using a network with more basis functions. Copyright 2007 ACM.