945 resultados para PEN-TABLET
Resumo:
An inexpensive, simple, precise and rapid method for the determination of fluoroquinolone gatifloxacin in tablets is described. The procedure is based on the use of volumetric dosage in a non-aqueous medium in glacial acetic acid with 0.1 M perchloric acid. The method validation yielded good results and included the precision, recovery and accuracy. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay.
Resumo:
A simple, sensitive and accurate spectrophotometric method was developed for the assay of gatifloxacin in raw material and tablets. Validation of the method yielded good results concerning range, linearity, precision and accuracy. The absorbance was measured at 287 nm for gatifloxacin tablet solutions. The linearity range was found to be 4.0-14.0 μg/mL for gatifloxacin. It was also found that the excipients in the commercial tablets did not interfere with the method.
Resumo:
Flutamide is a potent antiandrogen used for the treatment of prostatic cancer. A simple, sensitive and accurate high-performance liquid Chromatographic (HPLC) method is presented for quantitative determination of flutamide in tablets, using a reversed-phase technique and UV detection at 240 nm. The isocratic elution was used to quantify the analyte. The samples were chromatographed on Luna-C18 column and the mobile phase was 0.05 M phosphate buffer pH 4.0 - acetonitrile (50:50, v/v). The method was linear between 2.9 - 11.6 mg L -1. Over the tested concentration range the intra-day relative standard deviation for replicate analysis in tablets ranged from 0.44 to 0.78%. It was also found that the excipients in the commercial tablets did not interfere with the method.
Resumo:
A simple and reproducible method was developed for the assay of lomefloxacin in tablets. The excipients in the commercial tablet preparation did not interfere with the assay. Beer's law is obeyed in the range 2.0-9.0 μg.mL-1 at λmax 280 nm. The molar absorptivity was calculated. Six triplicate analyses of solutions containing six different concentrations of the examined drug were carried out and gave a mean correlation coefficient 0.9997. The proposed method was applied to the determination of the examined drug in coated tablet and the results demonstrated that the method is equally accurate, precise and reproducible as the official methods.
Resumo:
The aim of this work was to evaluate the influence of compression force and humidity in the dissolution profile of tablets formulation. As hidroclorotyiazide presents real problems of bioavailability, it was incorporate as standard drug in a formulation of tablets to study the mechanical resistance, time of disintegration and dissolution profile in function of humidity and compression force. The time of disintegration was not affected by the compression force, but it was influenced by humidity. The dissolution profile was altered by the compression force and for the humidity as well. Both factors can alter the bioavailability of drugs dispensed in the form of tablets.
Resumo:
A specific and sensitive high-performance liquid chromatographic method was developed for the assay of praziquantel in raw materials and tablets. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay in the wavelenght selected. The method validation yielded good results and included the range, linearity, precision, accuracy, specificity and recovery.
Resumo:
The compaction behavior of powdered solids used in tablets can be dominated by the physical-chemical properties of the excipients because, frequently, they are present in much larger amounts than the drug in tablet formulation. The aim of this study was to evaluate the influence of the size of lactose granules on the physical characteristics of tablets produced in punches of various diameters, since this relation has not been explored in the literature. Granules were produced in several sizes by wet granulation and compressed in punches of different diameters by applying different forces. Size distribution, apparent density and flow of granules were evaluated, as well as the physical characteristics of the tablets (weight, friability, hardness and disintegration time). The results indicate that in situations where excipient characteristics predominate due to low drug content, as in the 7 mm punch, the selection of granule size is important for the mechanical strength of tablet. On the other hand, with the 9, 11 and 13mm punches, it was possible to produce strong tablet from all sizes of granules.
Resumo:
Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.
Resumo:
Exposure to agrichemicals can have deleterious effects on fish, such as disruption of the hypothalamus-pituitary-inter-renal axis (HPI) that could impair the ability of fish to respond to stressors. In this study, fingerlings of the teleost jundiá (Rhamdia quelen) were used to investigate the effects of the commonly used agrichemicals on the fish response to stress. Five common agrichemicals were tested: the fungicide - tebuconazole, the insecticide - methyl-parathion, and the herbicides - atrazine, atrazine + simazine, and glyphosate. Control fishes were not exposed to agrichemicals and standard stressors. In treatments 2-4, the fishes were exposed to sub-lethal concentrations (16.6%, 33.3%, and 50% of the LC50) of each agrichemical for 96 h, and at the end of this period, were subjected to an acute stress-handling stimulus by chasing them with a pen net. In treatments 5-7 (16.6%, 33.3%, and 50% of the LC50), the fishes were exposed to the same concentrations of the agrichemicals without stress stimulus. Treatment 8 consisted of jundiás not exposed to agrichemicals, but was subjected to an acute stress-handling stimulus. Jundiás exposed to methyl-parathion, atrazine + simazine, and glyphosate presented a decreased capacity in exhibiting an adequate response to cope with stress and in maintaining the homeostasis, with cortisol level lower than that in the control fish (P < 0.01). In conclusion, the results of this study clearly demonstrate that the acute exposure to sub-lethal concentrations of methyl-parathion, atrazine + simazine, and glyphosate exert a deleterious effect on the cortisol response to an additional acute stressor in the jundiá fingerlings. © 2008 Elsevier Inc. All rights reserved.
Resumo:
The compaction behavior of powdered solids can be strongly influenced by the physicochemical properties of excipients because they are frequently present in the tablet in larger amounts than the drug itself. The aim of this study was to assess the influence of the granule size of the cellulose on the physical characteristics of tablets produced in punches of different diameters, since this relation has never been explored in the literature. Granules of several sizes were produced by wet granulation and compressed in punches of various diameters by applying different forces. Size distribution, apparent density and flow of granules were assessed, as well as physical characteristics of the tablets (weight, hardness, friability and disintegration time). Reducing the granule size resulted in tablets of adequate crushing strength and fast disintegration; moreover, it allowed tablets to be produced without the need to use forces near the upper limit of the press, thus avoiding premature wear on the tabletting machine. Thus, once a suitable size for a given tablet formulation has been chosen, the granule size selected has been shown to determine the crushing strength of the tablet.
Resumo:
A digital-desk pilot program, named One Laptop Per Child (OPLC), in Brazil uses a unique display design to provide an interactive interface developed to enhance education and minimize ergonomic concerns. The one-to-one computer strategy as proposed by Nicholas Negroponte is a way of circumventing the tragedy of the locked computer lab because it gives children full access to computers anytime. The OLPC program has focused on a solution that minimizes power consumption, which also limits the display's maximum size and processor performance because the LCD backlights are responsible for a significant part of the power consumption in laptops. The government has also developed a new type of low-cost tablet that is based on a resistive principle. High transparencies can be obtained in the 90% range in the tablet, while robustness is guaranteed by the outstanding tribological characteristics of Sn02 on glass.
Resumo:
The aim of this study was to evaluate alternative methods for the disinfection of toothbrushes considering that most of the previously proposed methods are expensive and cannot be easily implemented. Two-hundred toothbrushes with standardized dimensions and bristles were included in the study. The toothbrushes were divided into 20 experimental groups (n=10), according to microorganism considered and chemical agent used. The toothbrushes were contaminated in vitro by standardized suspensions of Streptococcus mutans, Streptococcus pyogenes, Staphylococcus aureus or Candida albicans. The following disinfectants were tested: 0.12% chlorhexidine digluconate, 50% white vinegar, a triclosan-containing dentifrice solution, and a perborate-based tablet solution. The disinfection method was immersion in the disinfectant for 10min. After the disinfection procedure, the number of remaining microbial cells was evaluated. The values of cfu/toothbrush of each group of microorganism after disinfection were compared by Kruskal-Wallis ANOVA and Dunn's test for multiple comparisons (5%). The chlorhexidine digluconate solution was the most effective disinfectant. The triclosan-based dentifrice solution promoted a significant reduction of all microorganisms' counts in relation to the control group. As to the disinfection with 50% vinegar, a significant reduction was observed for all the microorganisms, except for C. albicans. The sodium perborate solution was the less effective against the tested microorganisms. Solutions based on triclosan-containing dentifrice may be considered effective, nontoxic, cost-effective, and an easily applicable alternative for the disinfection of toothbrushes. The vinegar solution reduced the presence of S. aureus, S. mutans and S. pyogenes on toothbrushes.
Resumo:
X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 μm was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques. © 2010 American Institute of Physics.
Resumo:
Orbifloxacin is a fluoroquinolone with broad-spectrum antimicrobial activity, and belongs to the third generation of quinolones. Regarding the quality control of medicines, a validated microbiological assay for determination of orbifloxacin in pharmaceutical formulations has not as yet been reported. For this purpose, this paper reports the development and validation of a simple, sensitive, accurate and reproducible agar diffusion method to quantify orbifloxacin in tablet formulations. The assay is based on the inhibitory effect of orbifloxacin upon the strain of Staphylococcus aureus ATCC 25923 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.9992) in the selected range of 16.0-64.0 μg/mL, precise with relative standard deviation (RSD) of repeatability intraday = 2.88%, intermediate precision RSD = 3.33%, and accurate (100.31%). The results demonstrated the validity of the proposed bioassay, which allows reliable orbifloxacin quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2011 by the authors; licensee MDPI, Basel, Switzerland.
Resumo:
An experiment was carried out to evaluate the performance of piglets fed rations containing fermented milk and zinc and copper amino acid complex. Sixty four piglets, littermates, were used. The experimental design was based on random block with two dietary treatments. One of these contained a basal diet (DB) with ZnO e CuSO 4 and the other one with the DB, but without CuSO 4 and with the addition of fermented milk and zinc and copper amino acid complex (SLF Lact +ZnCuAA). There were eight replicate pens per treatment, and pigs were grouped at 4 per pen. The SLF Lact + ZnCuAA didn't not affect (p>0.05) final live weight of the piglets. However, live weight was different (p<0.01) between males and females (24.3 vs. 24.0 kg) at end of experiment. The feed intake of animals feed with SLF Lact+ZnCuAA was higher (p<0.01) in 8% in the first 14 days (0.261 vs. 0.239 kg/d), 15% from 15 to 28 days (0.756 vs. 0.675 kg/ d) and 12% from 29 to 42 days (1.091 vs. 0.962 kg/ d) compared to control group. Daily average feed intake in the experimental period was 11% higher (p<0.01) for the animals fed with the diet contained SLF Lact+ZnCuAA. Weight gain of the treatment with SLFL act+ZnCuAA was higher (p<0.01) by 14% from 0 to 14 days (0.176 vs. 0.152 kg/d), 11% from 15 to 28 days (0.564 vs. 0.500 kg/d) and 12% from 29 to 42 days (0,572 vs. 0,501 kg/d). Average daily weight gain of 42 days of trial of treatment with SLF Lact +ZnCuAA was 12% higher (p<0.01) compared to control group (0.437 vs. 0.384 kg/d). Feed conversion ratio was 8% lower (p<0.01) for treatment with SLF Lact+ZnCuAA in the first 14 days (1.487 vs. 1.614). Supplementation with fermented milk and zinc and copper amino acid complex in diets containing zinc oxide improved growth performance of weanling piglets.