998 resultados para CASTE DETERMINATION
Resumo:
An amperometric biosensor for monitoring phenols in the organic phase was constructed by the silica sol-gel immobilization of tyrosinase on a glassy carbon electrode. The organic-inorganic hybrid materials with different sol-gel precursors and polymers were optimized, and the experimental conditions, such as the effect of the solvent, operational potential and enzyme loading were explored for the optimum analytical performance of the enzyme electrode. The biosensor can reach 95% of steady-state current in about 18 s, and the trend in the sensitivity of different phenols is as follows: catechol > phenol >p-cresol. In addition, the apparent Michaelis-Menten constants (K-m(app)) and the stability of the enzyme electrode were discussed. (C) 2000 Elsevier Science S.A. All rights reserved.
Resumo:
Three beta -blockers (propranolol, timolol, acebutolol) were separated by capillary electrophoresis (CE) and detected by end-column electrochemical detection (EC). In the present work, a carbon fiber (33 mum) electrode was used as the working electrode. The effect of the buffer concentration, buffer pH, detection potential and separation voltage on the separation of analytes and behavior of electrochemical detection was systematically investigated. The optimum conditions determined were as following: 40 cm length, 25 mum i.d. capillary; 17.5 kV separation voltage; 2 s injection at 15 kV; 70mM phosphate buffer, pH 3.5; detection potential + 1.2V (vs. Ag/AgCl). Under these conditions, the linear ranges of beta -blockers were over three orders of magnititude and the low detection limit of 10(-8)M was obtained. This method was also applied to detect the simulated urine sample.
Resumo:
Inductively coupled plasma mass spectrometry (ICP-MS),a highly sensitive inorgnic analytic technique,fits to determine ultra-nace rare-earth elements in human plasma. Under the optimized conditions detection limits for 15 rare-earth elements are in the range of 0.7 (for Eu)-5.4 (for Gd) ng.L-1. Indium as an internal standard element is used to compensate for matrix suppression effect and sensitivity drift. Three kinds of preparation methods, diluted with 1% HNO3, digested with HNO3-H2O2 and with HNO3-HClO4, are checked and compared,and the former is the simplest way to be measured. The samples diluted with 1% HNO3, stored in 4 degrees C, are very steady for 16 days. With the method, 11 healthy plasma samples in Changchun area of China are analysed.
Resumo:
Capillary electrophoresis with amperometric detection is evaluated for the simultaneous determination of 2-aminothiazole (A), 2-amino-benzothiazole (AB), 2-mercaptobenzothiazole (AM). The cyclic voltammogram, hydrodynamic voltammogram, effect of pH, concentration of buffer and separation voltage on the separation and the detection were studied. The conditions were optimized as follows: 50 mM phosphate buffet; pH 6.0, 2s at 17.5 kV sample injection, separation at 17.5 kV, 1.2 V as detection potential. The method provided low detection limit as 0.5 mu M, 0.05 mu M and 0.01 mu M, wide linear range 2-200 mu M, 10-200 mu M and 0.025-100 mu M for A, AB, and AM, respectively. The variations in peak current and migration time for 15 consecutive injections of a standard containing 5 mu M each compound were 3.7, 2.1, and 3.9%, and 1.2, 0.8, and 1.2%, for A, AB and AM, respectively. This method was employed to analyze river water.
Resumo:
A capillary electrophoresis-amperometric detection system was developed for the determination of propranolol (PRO) at a 33 mu m carbon fiber microdisk electrode (CFE). The cyclic voltammogram, the hydrodynamic voltammograms and the effect of pH were studied. Under the optimum conditions: separation Voltage 15 kV; injection 3 s at 15 kV; 10 mM pH 7.5 phosphate buffer, 1.15 V (vs. Ag/AgCl) detection potential, the detection limit (LOD) for PRO was 0.05 mu M (S/N = 3). The response for PRO was linear over two orders of magnitude with a linear correlation coefficient of 0.994. The feasibility of this method was demonstrated by the detection of PRO in urine sample.
Resumo:
Capillary electrophoresis (CE) with end-column electrochemical detection (EC) of barbituric acid (BA) and 2-thiobarbituric acid (TA) has been described. Under optimum condition, BA and TA were separated satisfactorily, and a response of high sensitivity and stability was obtained at a detection potential of 1.25 V versus Ag/AgCl. Optimized end-column detection provides detection limit as low as 0.5 and 0.1 mu M for BA and TA, respectively. The calibration graph was linear over three orders of magnitude. The relative standard deviations (n = 10) of peak currents and migration times obtained for both BA and TA were 3.4, 3.7, and 1.7, 1.2%, respectively. The proposed method has been applied to analyze water sample with satisfactory results. (C) 2000 Elsevier Science B.V. All rights reserved.
Resumo:
A novel method for the sensitive and selective determination of peroxydisulfate was proposed. It was based on an electrochemiluminescent method with Cr(bpy)(3)(3+). The applied potential was set at -0.5 V in Cr(bpy)(3)(3+) system which was much more positive than those in Ru(bpz)(3)(2+) and Ru(bpy)(3)(2+) systems. A linear calibration was obtained over the range of 7-100 mu mol l(-1) with a correlation coefficient of 0.993. The relative standard deviation was 2% for 10 replicate injections of 0.01 mol l(-1) S2O82- solution. The detection limit (S/N=3) was 1 mu mol l(-1). The method was successfully applied to determination of peroxydisulfate in phase transfer catalysis. (C) 2000 Elsevier Science B.V. All rights reserved.
Resumo:
The self-assembled monolayer(SAM) of 11-mercaptoundecanoic acid [HS(CH2)(10)COOH] was formed on a gold electrode and the effect of the charge of end group on the electrochemical response of Fe(CN)(6)(3-) at the SAM modified electrode was studied by cyclic voltammetry. At high pH, when the -COOH groups are dissociated, the current of Fe(CN)(6)(3-) is suppressed; as the solution pH is lowered, the current of Fe(CN)(6)(3-) increases. The electrochemical titration curve was obtained by correlating the currents of Fe(CN)(6)(3-) to the different pH values of electrolyte, from which the surface pK(a) was obtained to be 3. 0+/-0. 2. Furthermore, the reason of small pK(a) value was explained using SAMs of different surface coverage.
Resumo:
A new type of organic-inorganic composite material was prepared by sol-gel method, and a peroxidase biosensor was fabricated by simply dropping sor-gel-peroxidase mixture onto glassy carbon electrode surface. The sol-gel composite film and enzyme membrane were characterized by Fourier-transform infrared (FT-IR) spectroscopy and EQCM, the electrochemical behavior of the biosensor was studied with potassium hexacyanoferrate(II) as a mediator, and the effects of pH and operating potential were explored for optimum analytical performance by using amperometric method. The response time of the biosensor was about 10 s; the linear range was up to 3.4 mM with a detection limit of 5 x 10(-7) M. The sensor also exhibited high sensitivity (15 mu A mM(-1)) and good long-term stability. In addition, the performance of the biosensor was investigated using flow injection analysis (FIA), and the determination of hydrogen peroxide in real samples was discussed. (C)2000 Elsevier Science B.V. All rights reserved.
Resumo:
A novel method is employed for the simultaneous determination of both the calibration constant of an electrochemical quartz crystal microbalance (EQCM) and the active surface area of a polycrystalline gold electrode. A gold electrode: is immersed into a 1 mM KI/1 M H2SO4 solution and on which forms a neutral monolayer. The adsorbed iodine can then be completely oxidized into IO3-. The active surface area of a gold electrode can be obtained from the net electrolytic charge of the oxidation process, and the calibration constant in the EQCM can be calculated from the corresponding frequency shift. The result shows that this method is simple, convenient and valid. (C) 2000 Elsevier Science S.A. All rights reserved.
Resumo:
In this work some basic constants of extractant Sec-Octylphenoxy acetic acid (CA-12) such as solubility (S) in water, dissociation constant (K-a) in aqueous solution, dimerization constant( K-2) and distribution constant (K-d) between water and haptane have been determined by two phase titration method. The results are as follows: S = 1.40 x 10(-4) mol/L, K-a = 3.02 x 10(-4), K-2 = 3.56 x 10(2), K-d = 4.06 x 10(2) (25 +/-0.5 degreesC).
Resumo:
A simple method was proposed for the separation of allopurinol (AP) and its active metabolite oxypurinol (OP) by capillary electrophoresis with end-column amperometric detection. A running buffer composed of 15 rum Na2HPO4/NaH2PO4 at a pH 9.55, electrokinetic injection 7 s at 5 kV, separation voltage at 15 kV and detection potential at 1.20 V were investigated to be the optimal condition for the separation. The method exhibited low detection Emit (S/N = 3) as 1 x 10(-8) mol/l for AP and OP, wide linearity range of 2 x 10(-7) to 1 x 10(-4) mol/l, 1 x 10(-7) to 1 x 10(-4) and high efficiency of 1.2 x 10(5) and 1.8 x 10(5) N/m for AP and OP, respectively. The potential application examined for the method was the determination of the spiked urine sample, which was proved to be sensitive and efficient. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
The p-toluene sulfonic acid (MA) in phenol matrix was separated and determined by capillary electrophoresis with ultraviolet detector. the effect of the concentration and pH of the buffer on separation was investigated. Cinnamic acid has been chosen as the internal standard from four compounds, the calibration curves of PTSA in 50 mg/L phenol matrix were obtained with and without the internal standard. The linear range was from 1.25 to 12.5 mg/L and the correlation coefficient was 0.9999 for both curves. The limit of detection of PISA was 0.75 mg/L at 3 times of SIN. Finally, the concentration of PTSA in four synthesized samples was determined with method of standard additions, and the effect of matrix was discussed. The values of MA in these samples were 1.01, 0.94, 1.56 and 0.00 mg/L respectively.
Resumo:
A new method for simultaneous spectrophotometric determination of Zn, Cd and Hg using 2-(5-Br-2-pyridylazo)-5-diethylaminophenol as the color developing reagent was proposed. The absorption spectra of these three complexes have similar features with severe overlap in visible spectral range. For resolving these spectra, hybrid linear analysis was used, and the pure spectrum of each component was obtained from the calibration mixtures by least squares method. The effects of reaction condition, selection of wavelengths, determination of pure spectrum and additivity of absorbances etc. on the determination were discussed. The proposed method offers the advantages of simple, rapid, and accuracy. It has been successfully applied to the simultaneous determination of Zn, Cd and Hg in synthetic sample. A comparison was also made with the partial least squares method.
Resumo:
Hybrid linear analysis (HLA) was applied to resolution of overlapping spectra of Fe3+-salicylfluorone and Al3+-salicylfluorone complexes and simultaneous spectrophotometric determination of Fe3+ and Al3+. The absorbance matrix of 7 standard mixtures at 41 measuring points ranged from the wavelength of 550 nm to 630 nm was used for calibration. To avoid the effect of interaction between the two components on the determination, the column vector of K matrix obtained from the standard mixtures with least squares was used as the pure spectrum of component. The recoveries of the two elements for the analysis of the synthetic samples were 93.3% similar to 107.5% in the range of the concentration ratio of Fe3+:Al3+ = 10:1 to 1:8. Comparing with the partial least squares (PIS) model, the HLA method was simple, accuracy and precise.