873 resultados para BLOQUEO NEUROMUSCULAR-METODOS
Resumo:
Phyllorhiza punctata (P. punctata) is a jellyfish native to the southwestern Pacific. Herewith we present the biochemical and pharmacological characterization of an extract of the tentacles of P. punctata. The tentacles were subjected to three freezethaw cycles, homogenized, ultrafiltered, precipitated, centrifuged and lyophilized to obtain a crude extract (PHY-N). Paralytic shellfish poisoning compounds such as saxitoxin, gonyautoxin-4, tetrodotoxin and brevetoxin-2, as well as several secretory phospholipase A2 were identified. PHY-N was tested on autonomic and somatic neuromuscular preparations. In mouse vas deferens, PHY-N induced phasic contractions that reached a peak of 234 +/- 34.7% of control twitch height, which were blocked with either 100 mu m of phentolamine or 1m m of lidocaine. In mouse corpora cavernosa, PHY-N evoked a relaxation response, which was blocked with either L-NG-Nitroarginine methyl ester (0.5 m m) or 1m m of lidocaine. PHY-N (1, 3 and 10 mu g ml(-1)) induced an increase in tonus of the biventercervicis neuromuscular preparation that was blocked with pre-treatment of galamine (10 mu m). Administration of 6 mg kg(-1) PHY-N intramuscularly produced death in broilers by spastic paralysis. In conclusion, PHY-N induces nerve depolarization and nonspecifically increases neurotransmitter release. Copyright (C) 2011 John Wiley & Sons, Ltd.
Resumo:
O objetivo deste estudo foi o de avaliar uma associação anestésica com e sem a utilização de relaxante muscular não-despolarizante e seu efeito sobre a pressão intra-ocular de eqüinos. Também objetivou-se uma técnica anestésica sem efeitos adversos que possa ser utilizada em procedimentos e cirurgias oftálmicas nesta espécie animal. Para tanto, dezesseis eqüinos foram divididos aleatoriamente em dois grupos de oito animais cada. Os animais do grupo I foram pré-medicados com romifidina, induzidos com tiletamina/zolazepam e a anestesia foi mantida com halotano e vecurônio. Os animais do grupo II receberam a mesma associação anestésica, com exceção do vecurônio. No decorrer do experimento, a pressão intra-ocular, a pressão arterial e a freqüência cardíaca foram avaliadas em diferentes momentos. A associação anestésica composta pela romifidina, tiletamina/ zolazepam e halotano com e sem vecurônio não promoveu alterações estatisticamente significativas na pressão intra-ocular de eqüinos e o seu uso é exeqüível em procedimentos oftálmicos nesta espécie animal.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Durante o processo de assimilação e uso dos alimentos, diferentes respostas metabólicas podem ser desenvolvidas pelo organismo dos animais. Estas respostas são fruto da integração de mecanismos complexos, que envolvem os sistemas neuro-endócrino e o funcionamento dos órgãos, sendo influenciadas pela dieta, espécie animal, idade, condição fisiológica e composição corporal. Este trabalho enfoca a importância fisiológica e os métodos de estudo das respostas pós-prandiais aos carboidratos, bem como as alterações fisiológicas conseqüentes ao balanço eletrolítico da dieta. A quantidade, estrutura química e processamento industrial do amido determinam boa parte da resposta pós-prandial de glicose e insulina de cães. em gatos, outros mecanismos parecem ser mais importantes, como a ingestão de aminoácidos. A fibra alimentar também altera a resposta pós-prandial ao alimento, devendo ser consideradas sua quantidade, solubilidade e fermentabilidade no desenvolvimento das dietas. Os métodos de estudo destas respostas incluem avaliação das respostas glicêmica e insulínca pós-prandiais, teste endovenoso de tolerância à glicose e à arginina. O clâmp euglicêmico apresenta-se também como ferramenta de estudo, no entanto revela informações mais relacionadas ao animal do que à dieta. A compreensão do conjunto de alterações metabólicas aos carboidratos é importante no estudo do controle da saciedade, composição corporal e inúmeras doenças degenerativas e endócrinas. A concentração e relação entre os macro-elementos da dieta (Na, Cl, K, P, Ca, Mg e S) e dos aminoácidos sulfurados (metionina, cistina e taurina) interferem em inúmeras funções orgânicas, como a cardiovascular, neuromuscular, metabolismo ósseo, renal e pulmonar, refletindo-se no equilíbrio hidro-eletrolítico e ácido-básico orgânicos. de importância prática para cães e gatos encontram-se a relação destes nutrientes com cardiopatias, nefropatias, osteodistrofias e urolitíases. A relação entre os macro-elementos é estabelecida em mmol/kg de matéria seca da dieta, calculando-se seu balanço cátion-ânion (excesso de bases ou ânions dietéticos não determinados). Suas repostas orgânicas são medidas, dentre outros métodos, pela hemogasimetria, balanço hídrico, mensuração do volume dos espaços extracelular e vascular, supersaturação e pH urinários.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this work is presented a new method for the determination of the orbital period (Porb) of eclipsing binary systems based on the wavelet technique. This method is applied on 18 eclipsing binary systems detected by the CoRoT (Convection Rotation and planetary transits) satellite. The periods obtained by wavelet were compared with those obtained by the conventional methods: box Fitting (EEBLS) for detached and semi-detached eclipsing binaries; and polynomial methods (ANOVA) for contact binary systems. Comparing the phase diagrams obtained by the different techniques the wavelet method determine better Porb compared with EEBLS. In the case of contact binary systems the wavelet method shows most of the times better results than the ANOVA method but when the number of data per orbital cicle is small ANOVA gives more accurate results. Thus, the wavelet technique seems to be a great tool for the analysis of data with the quality and precision given by CoRoT and the incoming photometric missions.
Resumo:
Oil prospecting is one of most complex and important features of oil industry Direct prospecting methods like drilling well logs are very expensive, in consequence indirect methods are preferred. Among the indirect prospecting techniques the seismic imaging is a relevant method. Seismic method is based on artificial seismic waves that are generated, go through the geologic medium suffering diffraction and reflexion and return to the surface where they are recorded and analyzed to construct seismograms. However, the seismogram contains not only actual geologic information, but also noise, and one of the main components of the noise is the ground roll. Noise attenuation is essential for a good geologic interpretation of the seismogram. It is common to study seismograms by using time-frequency transformations that map the seismic signal into a frequency space where it is easier to remove or attenuate noise. After that, data is reconstructed in the original space in such a way that geologic structures are shown in more detail. In addition, the curvelet transform is a new and effective spectral transformation that have been used in the analysis of complex data. In this work, we employ the curvelet transform to represent geologic data using basis functions that are directional in space. This particular basis can represent more effectively two dimensional objects with contours and lines. The curvelet analysis maps real space into frequencies scales and angular sectors in such way that we can distinguish in detail the sub-spaces where is the noise and remove the coefficients corresponding to the undesired data. In this work we develop and apply the denoising analysis to remove the ground roll of seismograms. We apply this technique to a artificial seismogram and to a real one. In both cases we obtain a good noise attenuation
Resumo:
Background: The myotonic dystrophy (MD) is a multisystem neuromuscular disease that can affect the respiratory muscles and heart function, and cause impairment in quality of life. Objectives: Investigate the changes in respiratory muscle strength, health-related quality of life (HRQoL) and autonomic modulation heart rate (HR) in patients with MD. Methods: Twenty-three patients performed assessment of pulmonary function, sniff nasal inspiratory pressure (SNIP), the maximal inspiratory (MIP) and expiratory (MEP) pressure, and of HRQoL (SF-36 questionnaire). Of these patients, 17 underwent assessment of heart rate variability (HRV) at rest, in the supine and seated positions. Results: The values of respiratory muscle strength were 64, 70 and 80% of predicted for MEP, MIP, and SNIP, respectively. Significant differences were found in the SF-36 domains of physical functioning (58.7 ± 31,4 vs. 84.5 ± 23, p<0.01) and physical problems (43.4 ± 35.2 vs. 81.2 ± 34, p<0.001) when patients were compared with the reference values. Single linear regression analysis demonstrated that MIP explains 29% of the variance in physical functioning, 18% of physical problems and 20% of vitality. The HRV showed that from supine position to seated, HF decreased (0.43 x 0.30), and LF (0.57 x 0.70) and the LF/HF ratio (1.28 x 2.22) increased (p< 0.05). Compared to healthy persons, LF was lower in both male patients (2.68 x 2.99) and women (2.31 x 2.79) (p< 0.05). LF / HF ratio and LF were higher in men (5.52 x 1.5 and 0.8 x 0.6, p <0.05) and AF in women (0.43 x 0.21) (p< 0.05). There was positive correlation between the time of diagnosis and LF / HF ratio (r = 0.7, p <0.01). Conclusions: The expiratory muscle strength was reduced. The HRQoL was more impaired on the physical aspects and partly influenced by changes in inspiratory muscle strength. The HRV showed that may be sympathetic dysfunction in autonomic modulation of HR, although with normal adjustment of autonomic modulation during the change of posture. The parasympathetic modulation is higher in female patients and sympathetic tends to increase in patients with longer diagnosis
Resumo:
I ntroduction: The assessment of respiratory muscle strength is important in the diagnosis and monitoring of the respiratory muscles weakness of respiratory and neuromuscular diseases. However, there are still no studies that provide predictive equations and reference values for maximal respiratory pressures for children in our population. Aim: The purpose of this study was to propose predictive equations for maximal respiratory pressures in healthy school children. Method: This is an observational cross-sectional study. 144 healthy children were assessed. They were students from public and private schools in the city of Natal /RN (63 boys and 81 girls), subdivided in age groups of 7-8 and 9-11 years. The students presented the BMI, for age and sex, between 5 and 85 percentile. Maximal respiratory pressures were measured with the digital manometer MVD300 (Globalmed ®). The maximal inspiratory pressure (MIP) and maximal expiratory pressures (MEP) were measured from residual volume and total lung capacity, respectively. The data were analyzed using the SPSS Statistics 15.0 software (Statistical Package for Social Science) by assigning the significance level of 5%. Descriptive analysis was expressed as mean and standard deviation. T'Student test was used for unpaired comparison of averages of the variables. The comparison of measurements obtained with the predicted values in previous studies was performed using the paired t'Student test. The Pearson correlation test was used to verify the correlation of MRP's with the independent variables (age, sex, weight and height). For the equations analysis the stepwise linear regression was used. Results: By analyzing the data, we observed that in the age range studied MIP was significantly higher in boys. The MEP did not differ between boys and girls aged 7 to 8 years, the reverse occurred in the age between 9 and 11 years. The boys had a significant increase in respiratory muscle strength with advancing age. Regardless sex and age, MEP was always higher than the MIP. The reference values found in this study are similar to a sample of Spanish and Canadian children. The two models proposed in previous studies with children from other countries were not able to consistently predict the values observed in this studied population. The variables sex, age and weight correlated with MIP, whereas the MEP was also correlated with height. However, in the regression models proposed in this study, only gender and age were kept exerting influence on the variability of maximal inspiratory and expiratory pressures. Conclusion: This study provides reference values, lower limits of normality and proposes two models that allow predicting, through the independent variables, sex and age, the value of maximal static respiratory pressures in healthy children aged between 7 and 11 years old
Resumo:
Objective: To evaluate the acute effects of static stretching before and after isokinetic exercise, neuromuscular and biomechanical properties of muscles Biceps Femoris (BF) and semitendinosus (ST). Methods: Eighty-nine volunteers of both genders, healthy and physically active, with a mean age of 22.52 ± 2.6 years and mean BMI 23.86 ± 3.2 kg/m² were randomized into 4 groups: Control Group (CG) made only one Protocol Exercise (PE) without performing the stretching, the Experimental Group 1 (EG1) did stretching before PE; EG2 did the stretching after PE and EG3 did stretching before and after PE. The volunteers were evaluated on the following variables: Range of motion (ROM), soreness, dynamometric variables concentric and eccentric, Neuromuscular Latency Time (NLT) and electromyographic. In the data analysis was assigned a significance level of 5%. Results: ADM and TLNM reported significant reduction in CG, but remained unchanged in GE with p<0,05 and p<0,01, respectively. As for the soreness, no differences between the groups. The electromyographic activity of the BF and ST, in the concentric phase, showed a significant decrease in all groups (p<0,01). However, in the eccentric phase, ST revealed reduction in all groups (p <0.01), except for the CG, while the BF remained unchanged in all groups. The PT showed significant reduction in both conditions (concentric and eccentric) for all groups, with no difference between them (p<0,01). Conclusion: The results of this study do not favor the use of static stretching, even of short duration, before physical activity. However, after exercise or at times unrelated to the sport, he should be given with the aim of avoiding muscle shortening
Resumo:
This work is about the 21st century reinforced concrete analysis under the point of view of its constituent materials. First of all it is described the theoretical approach of the bending elements calculated based on the Norms BAEL 91 standarts. After that, numerical load-displacement are presented from reinforced concrete beams and plates validated by experimental data. The numerical modellings has been carried on in the program CASTEM 2000. In this program a elastoplastic model of Drucker-Prager defines the rupture surface of the concrete in non associative plasticity. The crack is smeared on the Gauss points of the finite elements with formation criterion starting from the definition of the rupture surface in the branch traction-traction of the Rankine model. The reinforcements were modeled in a discrete approach with perfect bond. Finally, a comparative analysis is made between the numerical results and calculated criteria showing the future of high performance reinforced concrete in this beginning of 21st century.
Resumo:
The objective of this paper is the numerical study of the behavior of reinforced concrete beams and columns by non-linear numerical simulations. The numerical analysis is based on the finite element method implemented in CASTEM 2000. This program uses the constitutive elastoplastic perfect model for the steel, the Drucker-Prager model for the concrete and the Newton-Raphson for the solution of non-linear systems. This work concentrates on the determination of equilibrium curves to the beams and force-strain curves to the columns. The numeric responses are confronted with experimental results found in the literature in order to check there liability of the numerical analyses.
Resumo:
The concrete offshore platforms, which are subjected a several loading combinations and, thus, requires an analysis more generic possible, can be designed using the concepts adopted to shell elements, but the resistance must be verify in particular cross-sections to shear forces. This work about design of shell elements will be make using the three-layer shell theory. The elements are subject to combined loading of membrane and plate, totalizing eight components of internal forces, which are three membrane forces, three moments (two out-of-plane bending moments and one in-plane, or torsion, moment) and two shear forces. The design method adopted, utilizing the iterative process proposed by Lourenco & Figueiras (1993) obtained from equations of equilibrium developed by Gupta (1896) , will be compared to results of experimentally tested shell elements found in the literature using the program DIANA.
Resumo:
Objective To compare the cardiorespiratory effects and incidence of gastroesophageal reflux with the use of a laryngeal mask airway (LMA) or endotracheal tube (ET) in anesthetized cats during spontaneous (SV) or controlled ventilation (CV).Study design Prospective randomized experimental trial.Animals Thirty-two adult crossbred cats, weighing 2.7 +/- 0.4 kg.Methods the cats were sedated with intramuscular (IM) methotrimeprazine (0.5 mg kg(-1)) and buprenorphine (0.005 mg kg(-1)), followed 30 minutes later by induction of anesthesia with intravenous (IV) thiopental (12.5-20 mg kg(-1)). An ET was used in 16 cats and an LMA in the remaining 16 animals. Anesthesia was maintained with 0.5 minimum alveolar concentration (0.6%) of halothane in oxygen using a Mapleson D breathing system. Cats in both groups were further divided into two equal groups (n = 8), undergoing either SV or CV. Neuromuscular blockade with pancuronium (0.06 mg kg(-1)) was used to facilitate CV. Heart and respiratory rates, direct arterial blood pressure, capnometry (PE'CO2) and arterial blood gases were measured. Gastric reflux and possible aspiration was investigated by intragastric administration of 5 mL of radiographic contrast immediately after induction of anesthesia. Cervical and thoracic radiographs were taken at the end of anesthesia. Data were analyzed using ANOVA followed by Student-Newman-Keuls, Kruskal-Wallis or Friedman test where appropriate.Results Values for PaCO2 and PE'CO2 were higher in spontaneously breathing cats with the LMA when compared with other groups. Values of PaO2 and hemoglobin oxygen saturation did not differ between groups. Gastroesophageal reflux occurred in four of eight and two of eight cats undergoing CV with ET or LMA, respectively. There was no tracheal or pulmonary aspiration in any cases.Conclusions and clinical relevance the use of an LMA may be used as an alternative to endotracheal intubation in anesthetized cats. Although aspiration was not observed, gastric reflux may occur in mechanically ventilated animals.
Resumo:
Objective-To compare the ability of a sidestream capnograph and a mainstream capnograph to measure end-tidal CO2 (ETCO2) and provide accurate estimates of Paco(2) in mechanically ventilated dogs.Design-Randomized, double Latin square.Animals-6 healthy adult dogs.Procedure-Anesthesia was induced and neuromuscular blockade achieved by IV administration of pancuronium bromide. Mechanical ventilation was used to induce conditions of standard ventilation, hyperventilation, and hypoventilation. While tidal volume was held constant, changes in minute volume ventilation and Paco(2) were made by changing the respiratory rate. Arterial blood gas analysis was performed and ETCO2 measurements were obtained by use of either a mainstream or a sidestream capnographic analyzer.Results-A linear regression model and bias analysis were used to compare Paco(2) and ETCO2 measurements; ETCO2 measurements obtained by both capnographs correlated well with Paco(2). Compared with Paco(2), mainstream ETCO2 values differed by 3.15 +/- 4.89 mm Hg (mean bias +/- SD), whereas the bias observed with the sidestream ETCO2 system was significantly higher (5.65 +/- 5.57 mm Hg). Regardless of the device used to measure ETCO2, bias increased as Paco(2) exceeded 60 mm Hg.Conclusions and Clinical Relevance-Although the mainstream capnograph was slightly more accurate, both methods of ETCO2 measurement correlated well with Paco(2) and reflected changes in the ventilatory status. However, ETCO2 values > 45 mm Hg may inaccurately reflect the severity of hypoventilation as Paco(2) may be underestimated during conditions of hypercapnia (Paco(2) > 60 mm Hg).