864 resultados para Anesthetic techniques


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Often practical performance of analytical redundancy for fault detection and diagnosis is decreased by uncertainties prevailing not only in the system model, but also in the measurements. In this paper, the problem of fault detection is stated as a constraint satisfaction problem over continuous domains with a big number of variables and constraints. This problem can be solved using modal interval analysis and consistency techniques. Consistency techniques are then shown to be particularly efficient to check the consistency of the analytical redundancy relations (ARRs), dealing with uncertain measurements and parameters. Through the work presented in this paper, it can be observed that consistency techniques can be used to increase the performance of a robust fault detection tool, which is based on interval arithmetic. The proposed method is illustrated using a nonlinear dynamic model of a hydraulic system

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work provides a general description of the multi sensor data fusion concept, along with a new classification of currently used sensor fusion techniques for unmanned underwater vehicles (UUV). Unlike previous proposals that focus the classification on the sensors involved in the fusion, we propose a synthetic approach that is focused on the techniques involved in the fusion and their applications in UUV navigation. We believe that our approach is better oriented towards the development of sensor fusion systems, since a sensor fusion architecture should be first of all focused on its goals and then on the fused sensors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obtaining automatic 3D profile of objects is one of the most important issues in computer vision. With this information, a large number of applications become feasible: from visual inspection of industrial parts to 3D reconstruction of the environment for mobile robots. In order to achieve 3D data, range finders can be used. Coded structured light approach is one of the most widely used techniques to retrieve 3D information of an unknown surface. An overview of the existing techniques as well as a new classification of patterns for structured light sensors is presented. This kind of systems belong to the group of active triangulation method, which are based on projecting a light pattern and imaging the illuminated scene from one or more points of view. Since the patterns are coded, correspondences between points of the image(s) and points of the projected pattern can be easily found. Once correspondences are found, a classical triangulation strategy between camera(s) and projector device leads to the reconstruction of the surface. Advantages and constraints of the different patterns are discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The absolute necessity of obtaining 3D information of structured and unknown environments in autonomous navigation reduce considerably the set of sensors that can be used. The necessity to know, at each time, the position of the mobile robot with respect to the scene is indispensable. Furthermore, this information must be obtained in the least computing time. Stereo vision is an attractive and widely used method, but, it is rather limited to make fast 3D surface maps, due to the correspondence problem. The spatial and temporal correspondence among images can be alleviated using a method based on structured light. This relationship can be directly found codifying the projected light; then each imaged region of the projected pattern carries the needed information to solve the correspondence problem. We present the most significant techniques, used in recent years, concerning the coded structured light method

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumen tomado de la publicaci??n

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The speed of fault isolation is crucial for the design and reconfiguration of fault tolerant control (FTC). In this paper the fault isolation problem is stated as a constraint satisfaction problem (CSP) and solved using constraint propagation techniques. The proposed method is based on constraint satisfaction techniques and uncertainty space refining of interval parameters. In comparison with other approaches based on adaptive observers, the major advantage of the presented method is that the isolation speed is fast even taking into account uncertainty in parameters, measurements and model errors and without the monotonicity assumption. In order to illustrate the proposed approach, a case study of a nonlinear dynamic system is presented

Relevância:

20.00% 20.00%

Publicador:

Resumo:

University of Southampton, Dyslexia Services have developed a range of academic study skills resources available to download. This resource supports revision and techniques for use in examinations.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metodología: se realizó un estudio descriptivo para evaluar las ventajas de la técnica regional sobre la técnica general en mujeres ASA 1 y 2 en Hospital Occidente de Kennedy. Se evaluaron los signos vitales, tiempo de recuperación, analgesia postoperatoria y efectos colaterales. Resultados: se incluyeron un total de 177 pacientes, 79 con anestesia regional y 98 pacientes con anestesia general. Los resultados en el postoperatorio mostraron que no hay diferencias estadísticamente significativas en cuanto a manejo de dolor, efectos colaterales, variación en signos vitales. Se encontró una diferencia significativa en el tiempo de recuperación p=0,02 siendo la técnica espinal 20 minutos en promedio más prolongada. Discusión: ambas técnicas suponen una buena opción como técnica anestésica para pacientes llevadas a legrado obstétrico, a pesar que el tiempo de recuperación fue mayor en el grupo de técnica espinal, se obtuvo un mejor manejo del dolor, sin el requerimiento de otros analgésicos durante el postoperatorio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introducción: La anestesia total intravenosa (TIVA) es ampliamente usada y reportada en la literatura como técnica para disminuir la respuesta a la laringoscopia e intubación, en la inducción y mantenimiento de una adecuada anestesia, además de una mejor estabilidad hemodinámica y recuperación pos anestésica; sin embargo no existen un gran número de estudios que comparen el uso de TIVA, determinando si existen diferencias en el perfil farmacocinético según el género del paciente. Objetivo: Describir diferencias farmacocinéticas y de los tiempos de despertar y salida a la unidad de cuidados pos anestésicos (descarga), según el género; en pacientes que reciben TIVA, con remifentanil y propofol, orientado por Stangraf. Metodología: Estudio observacional analítico de corte transversal, en pacientes llevados a cirugía bajo TIVA en el Hospital Occidente de Kennedy en el periodo de junio de 2013 a Enero de 2014.Usando SPSS versión 20 Windows, se analizaron los datos mediante pruebas Kolmogorov-Smirnov y Shapiro-Wilk y U de Mann Withney. Un valor de p menor 0.05 fue aceptado como estadísticamente significativo. Resultados: Se aplicaron pruebas de normalidad y no se encontraron diferencias estadísticamente significativas entre género. El tiempo de despertar fue 9.36 minutos para mujeres y 11.26 minutos para hombres. Los tiempos de descarga fueron 10.71 minutos para mujeres y 12.82 minutos para hombres. Discusión. El tiempo de despertar y descarga no es diferente entre mujeres y hombres en los pacientes analizados. Se requieren estudios adicionales entre grupos poblacionales de diversas condiciones farmacocineticas para corroborar los datos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Descriptive study that identified chemical agents (AQ) use and training on risk management and waste disposal techniques in a public Hospital in Valencia. A questionnaire was answered by 48 workers. Information obtained was: personal data, occupational history, AQ used; knowledge of risk management and waste disposal. There were 16 occupations from 12 “High Risk” areas. “Adult emergency” was the one with more workers (11 individuals), followed by “sterilization” and “clinical laboratory” (7 each) and oncology (5). The remained areas had less than 8.3% workers. The most used anesthetic agents were: Halothane, Enfluorane and Isofluorane 4.17% each and main antineoplastics used were: Doxorubicin 16.67% and Paclitaxel, 5-Fluoracil and Etoposide, 8.33% each. The most mentioned substances were: alcohol (70.8%) and Chlorine (64.6%). None of the answers regarding knowledge of AQ’ risk management and waste disposal was satisfactory. Statistical associations between training and several variables such as age, time in their job and being or not a professional, resulted non-significant. The correlation between training and the knowledge of AQ’s management was significant (p < 0.001). Participants showed that their knowledge about chemical occupational risk factors they are exposed to is still insufficient. Therefore, this theme should be included in graduate course curricula. These results provide important data and will serve as a pilot research for the follow up Phase II study that will include clinical aspects and environmental and biological monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nos encontramos en la era de la optimización de costos, por lo que es necesario realizar estudios farmacoeconómicos para identificar la costo- efectividad de los anestésicos actuales. Metodología: este estudio prospectivo, cegado al paciente, comparó los costos directos, los tiempos de recuperación y satisfacción de 45 pacientes que se asignaron aleatoriamente a dos grupos de anestesia balanceada (grupo sevofluoraneremifentanil n = 24 o grupo isofluoraneremifentanil n = 21) que iban a ser sometidos a cirugías de otorrinolaringología. Resultados: los tiempos de recuperación temprana (apertura ocular, respuesta a comandos, extubación, orientación y salida de sala) fueron menores en el grupo ISO y tuvieron diferencia estadísticamente significativa. Se encontraron datos variables en los costos de adquisición de los halogenados gastados, que fueron menores para el isofluorane, lo cual hacía también menos costosos los insumos anestésicos durante las cirugías; sin embargo, los costos en la sala de cirugía, en recuperación y sala de ambulatorios y los costos totales no mostraron diferencias significativas. La satisfacción fue similar entre los dos grupos. Conclusiones: una técnica basada en sevofluorane-remifentanil no es más costo-efectiva que utilizar isofluorane-remifentanil para pacientes ambulatorios sometidos a cirugías de otorrinolaringología.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introducción: La evaluación de injertos vasculares de submucosa de intestino delgado para la regeneración de vasos sanguíneos ha producido una permeabilidad variable (0-100%) que ha sido concurrente con la variabilidad en las técnicas de fabricación. Metodología: Investigamos los efectos de fabricación en permeabilidad y regeneración en un diseño experimental de 22factorial que combino: 1) preservación (P) o remoción (R) de la capa estratum compactum del intestino, y 2) deshidratada (D) o hidratada (H), dentro de cuatro grupos de estudio (PD, RD, PH, RH). Los injertos fueron implantados en las Arterias Carótidas de porcinos (ID 4.5mm, N=4, 7d). Permeabilidad, trombogenicidad, reacción inflamatoria, vascularización, infiltración de fibroblastos, perfil de polarización de macrófagos y fuerza tensil biaxial fueron evaluadas. Resultados: Todos los injertos PD permanecieron permeables (4/4), pero tuvieron escasa vascularización e infiltración de fibroblastos. El grupo RD permaneció permeable (4/4), presentó una extensa vascularización e infiltración de fibroblastos, y el mayor número del fenotipo de macrófagos (M2) asociado a regeneración. El grupo RH presentó menor permeabilidad (3/4), una extensa vascularización e infiltración de fibroblastos, y un perfil dominante de M2. El grupo PH presentó el menor grado de permeabilidad, y a pesar de mayor infiltración celular que PD, exhibió un fenotipo de macrófagos dominante adverso. La elasticidad de los injertos R evolucionó de una manera similar a las Carótidas nativas (particularmente RD, mientras que los injertos P mantuvieron su rigidez inicial. Discusión: Concluimos que los parámetros de fabricación afectan drásticamente los resultados, siendo los injertos RD los que arrojaron mejores resultados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introducción: La hipotermia perioperatoria se ha documentado como factor de riesgo para el aumento de la morbimortalidad de los pacientes aumentando morbilidad miocárdica, riesgo de infección, pérdidas sanguíneas y tiempo de hospitalización. La aplicación de anestésicos toma relevancia ya que causa la pérdida de control central de la temperatura. Nuestro objetivo con este estudio fue describir la proporción de casos de hipotermia en la población sometida a un reemplazo articular durante un periodo de cuatro meses. Materiales y métodos: Se realizó un estudio de cohorte prospectivo. La población a estudio fueron los pacientes que fueron sometidos a un reemplazo total de cadera, rodilla u hombro. Se registró la temperatura central en el momento previo a la inducción anestésica, 30, 60 y 90 minutos después, al finalizar el procedimiento y al ingresar a recuperación. Se reportó el porcentaje de pacientes con hipotermia en cada tiempo. Resultados: Se analizaron en total 88 pacientes, el 55,7% fue llevado a cirugía de cadera, 39,7% de rodilla y 4,5% de hombro. El tipo de anestesia más utilizado fue general y la duración promedio de anestesia fue 164 minutos. La medición de la temperatura central se realizó en nasofaringe, esófago o tímpano. La proporción de pacientes que presentaron hipotermia en la inducción fue 21,6%, a 30 minutos 83%, a 60 minutos 73,9%, a 90 minutos 68,2%, al finalizar 59,1% y en recuperación 58%. Se realizó una prueba Chi cuadrado comparando las proporciones entre la inducción y los cinco periodos posteriores, se encontró que la proporción de pacientes con hipotermia en los cinco tiempos posteriores tuvo una diferencia estadísticamente significativa (p=0,00) comparada con la proporción de pacientes con hipotermia durante la inducción. Conclusión: En los pacientes sometidos a un reemplazo articular la hipotermia fue una condición prevalente posterior a la aplicación de los anestésicos sistémicos. Los dispositivos de calentamiento intraoperatorio usados actualmente son insuficientes para evitar la hipotermia, lo que indica concordancia con la literatura en cuanto a las recomendaciones de calentamiento perioperatorio, con énfasis en el precalentamiento, para prevenir la caída significativa de la temperatura y la morbimortalidad asociada.