854 resultados para Amplitude measurement
Resumo:
Material synthesizing and characterization has been one of the major areas of scientific research for the past few decades. Various techniques have been suggested for the preparation and characterization of thin films and bulk samples according to the industrial and scientific applications. Material characterization implies the determination of the electrical, magnetic, optical or thermal properties of the material under study. Though it is possible to study all these properties of a material, we concentrate on the thermal and optical properties of certain polymers. The thermal properties are detennined using photothermal beam deflection technique and the optical properties are obtained from various spectroscopic analyses. In addition, thermal properties of a class of semiconducting compounds, copper delafossites, arc determined by photoacoustic technique.Photothermal technique is one of the most powerful tools for non-destructive characterization of materials. This forms a broad class of technique, which includes laser calorimetry, pyroelectric technique, photoacollstics, photothermal radiometric technique, photothermal beam deflection technique etc. However, the choice of a suitable technique depends upon the nature of sample and its environment, purpose of measurement, nature of light source used etc. The polynler samples under the present investigation are thermally thin and optically transparent at the excitation (pump beam) wavelength. Photothermal beam deflection technique is advantageous in that it can be used for the detennination of thermal diffusivity of samples irrespective of them being thermally thick or thennally thin and optically opaque or optically transparent. Hence of all the abovementioned techniques, photothemlal beam deflection technique is employed for the successful determination of thermal diffusivity of these polymer samples. However, the semi conducting samples studied are themlally thick and optically opaque and therefore, a much simpler photoacoustic technique is used for the thermal characterization.The production of polymer thin film samples has gained considerable attention for the past few years. Different techniques like plasma polymerization, electron bombardment, ultra violet irradiation and thermal evaporation can be used for the preparation of polymer thin films from their respective monomers. Among these, plasma polymerization or glow discharge polymerization has been widely lIsed for polymer thin fi Im preparation. At the earlier stages of the discovery, the plasma polymerization technique was not treated as a standard method for preparation of polymers. This method gained importance only when they were used to make special coatings on metals and began to be recognized as a technique for synthesizing polymers. Thc well-recognized concept of conventional polymerization is based on molecular processcs by which thc size of the molecule increases and rearrangemcnt of atoms within a molecule seldom occurs. However, polymer formation in plasma is recognized as an atomic process in contrast to the above molecular process. These films are pinhole free, highly branched and cross linked, heat resistant, exceptionally dielectric etc. The optical properties like the direct and indirect bandgaps, refractive indices etc of certain plasma polymerized thin films prepared are determined from the UV -VIS-NIR absorption and transmission spectra. The possible linkage in the formation of the polymers is suggested by comparing the FTIR spectra of the monomer and the polymer. The thermal diffusivity has been measured using the photothermal beam deflection technique as stated earlier. This technique measures the refractive index gradient established in the sample surface and in the adjacent coupling medium, by passing another optical beam (probe beam) through this region and hence the name probe beam deflection. The deflection is detected using a position sensitive detector and its output is fed to a lock-in-amplifIer from which the amplitude and phase of the deflection can be directly obtained. The amplitude and phase of the deflection signal is suitably analyzed for determining the thermal diffusivity.Another class of compounds under the present investigation is copper delafossites. These samples in the form of pellets are thermally thick and optically opaque. Thermal diffusivity of such semiconductors is investigated using the photoacoustic technique, which measures the pressure change using an elcctret microphone. The output of the microphone is fed to a lock-in-amplificr to obtain the amplitude and phase from which the thermal properties are obtained. The variation in thermal diffusivity with composition is studied.
Resumo:
An open cell configuration has been employed for the photoacoustic measurement of the thermal diffusivity of undoped Bi2Se3 crystals and Bi2Se3 crystals doped with various concentrations of Te. The amplitude of the photoacoustic signal obtained under heat transmission configuration as a function of chopping frequency is used to evaluate the numerical value of thermal diffusivity, α. Doped samples show a substantial reduction in the value of α compared to undoped samples. The variations in the thermal diffusivity of the doped samples are explained in terms of the phonon assisted heat transfer mechanism. It is seen that α is very sensitive to structural variations arising from doping. The experimentally observed results are correlated with X-ray diffraction studies.
Resumo:
The dual-beam thermal lens technique has been found to be very effective for the measurement of fluorescence quantum yields of dye solutions. The concentration-dependence of the quantum yield of rhodamine B in methanol is studied here using this technique. The observed results are in line with the conclusion that the reduction in the quantum yield in the quenching region is essentially due to the non-radiative relaxation of the absorbed energy. The thermal lens has been found to become abberated above 40 mW of pump laser power. This low value for the upper limit of pump power is due to the fact that the medium is a resonantly absorbing one.
Resumo:
We report a photoacoustic (PA) study of the thermal and transport properties of a GaAs epitaxial layer doped with Si at varying doping concentration, grown on GaAs substrate by molecular beam epitaxy. The data are analyzed on the basis of Rosencwaig and Gersho’s theory of the PA effect. The amplitude of the PA signal gives information about various heat generation mechanisms in semiconductors. The experimental data obtained from the measurement of the PA signal as a function of modulation frequency in a heat transmission configuration were fitted with the phase of PA signal obtained from the theoretical model evaluated by considering four parameters—viz., thermal diffusivity, diffusion coefficient, nonradiative recombination time, and surface recombination velocity—as adjustable parameters. It is seen from the analysis that the photoacoustic technique is sensitive to the changes in the surface states depend on the doping concentration. The study demonstrates the effectiveness of the photoacoustic technique as a noninvasive and nondestructive method to measure and evaluate the thermal and transport properties of epitaxial layers.
Resumo:
Large amplitude local density fluctuations in a thin superfluid He film is considered. It is shown that these large amplitude fluctuations travel and behave like "quasi-solitons" under collision, even when the full nonlinearity arising from the Van der Waals potential is taken into account.
Resumo:
Laser‐induced damage and ablation thresholds of bulk superconducting samples of Bi2(SrCa)xCu3Oy(x=2, 2.2, 2.6, 2.8, 3) and Bi1.6 (Pb)xSr2Ca2Cu3 Oy (x=0, 0.1, 0.2, 0.3, 0.4) for irradiation with a 1.06 μm beam from a Nd‐YAG laser have been determined as a function of x by the pulsed photothermal deflection technique. The threshold values of power density for ablation as well as damage are found to increase with increasing values of x in both systems while in the Pb‐doped system the threshold values decrease above a specific value of x, coinciding with the point at which the Tc also begins to fall.
Resumo:
The photoacoustic technique under heat transmission configuration is used to determine the effect of doping on both the thermal and transport properties of p- and n-type GaAs epitaxial layers grown on GaAs substrate by the molecular beam epitaxial method. Analysis of the data is made on the basis of the theoretical model of Rosencwaig and Gersho. Thermal and transport properties of the epitaxial layers are found by fitting the phase of the experimentally obtained photoacoustic signal with that of the theoretical model. It is observed that both the thermal and transport properties, i.e. thermal diffusivity, diffusion coefficient, surface recombination velocity and nonradiative recombination time, depend on the type of doping in the epitaxial layer. The results clearly show that the photoacoustic technique using heat transmission configuration is an excellent tool to study the thermal and transport properties of epitaxial layers under different doping conditions.
Resumo:
Cochin University of Science and Technology
Resumo:
Among the large number of photothcrmal techniques available, photoacoustics assumes a very significant place because of its essential simplicity and the variety of applications it finds in science and technology. The photoacoustic (PA) effect is the generation of an acoustic signal when a sample, kept inside an enclosed volume, is irradiated by an intensity modulated beam of radiation. The radiation absorbed by the sample is converted into thermal waves by nonradiative de-excitation processes. The propagating thermal waves cause a corresponding expansion and contraction of the gas medium surrounding the sample, which in tum can be detected as sound waves by a sensitive microphone. These sound waves have the same frequency as the initial modulation frequency of light. Lock-in detection method enables one to have a sufficiently high signal to noise ratio for the detected signal. The PA signal amplitude depends on the optical absorption coefficient of the sample and its thermal properties. The PA signal phase is a function of the thermal diffusivity of the sample.Measurement of the PA amplitude and phase enables one to get valuable information about the thermal and optical properties of the sample. Since the PA signal depends on the optical and thennal properties of the sample, their variation will get reflected in the PA signal. Therefore, if the PA signal is collected from various points on a sample surface it will give a profile of the variations in the optical/thennal properties across the sample surface. Since the optical and thermal properties are affected by the presence of defects, interfaces, change of material etc. these will get reflected in the PA signal. By varying the modulation frequency, we can get information about the subsurface features also. This is the basic principle of PA imaging or PA depth profiling. It is a quickly expanding field with potential applications in thin film technology, chemical engineering, biology, medical diagnosis etc. Since it is a non-destructive method, PA imaging has added advantages over some of the other imaging techniques. A major part of the work presented in this thesis is concemed with the development of a PA imaging setup that can be used to detect the presence of surface and subsmface defects in solid samples.Determination of thermal transport properties such as thermal diffusivity, effusivity, conductivity and heat capacity of materials is another application of photothennal effect. There are various methods, depending on the nature of the sample, to determine these properties. However, there are only a few methods developed to determine all these properties simultaneously. Even though a few techniques to determine the above thermal properties individually for a coating can be found in literature, no technique is available for the simultaneous measurement of these parameters for a coating. We have developed a scanning photoacoustic technique that can be used to determine all the above thermal transport properties simultaneously in the case of opaque coatings such as paints. Another work that we have presented in this thesis is the determination of thermal effusivity of many bulk solids by a scanning photoacoustic technique. This is one of the very few methods developed to determine thermal effiisivity directly.
Resumo:
A new geometry (semiannular) for Josephson junction has been proposed and theoretical studies have shown that the new geometry is useful for electronic applications [1, 2]. In this work we study the voltage‐current response of the junction with a periodic modulation. The fluxon experiences an oscillating potential in the presence of the ac‐bias which increases the depinning current value. We show that in a system with periodic boundary conditions, average progressive motion of fluxon commences after the amplitude of the ac drive exceeds a certain threshold value. The analytic studies are justified by simulating the equation using finite‐difference method. We observe creation and annihilation of fluxons in semiannular Josephson junction with an ac‐bias in the presence of an external magnetic field.
Resumo:
In this paper we show that the orthorhombic phase of FeSi2 (stable at room temperature) displays a sizable anisotropy in the infrared spectra, with minor effects in the Raman data too. This fact is not trivial at all, since the crystal structure corresponds to a moderate distortion of the fluorite symmetry. Our analysis is carried out on small single crystals grown by flux transport, through polarization-resolved far-infrared reflectivity and Raman measurements. Their interpretation has been obtained by means of the simulated spectra with tight-binding molecular dynamics.
Resumo:
RMS measuring device is a nonlinear device consisting of linear and nonlinear devices. The performance of rms measurement is influenced by a number of factors; i) signal characteristics, 2) the measurement technique used and 3) the device characteristics. RMS measurement is not simple, particularly when the signals are complex and unknown. The problem of rms measurement on high crest-factor signals is fully discussed and a solution to this problem is presented in this thesis. The problem of rms measurement is systematically analized and found to have mainly three types of errors: (1) amplitude or waveform error 2) Frequency error and (3) averaging error. Various rms measurement techniques are studied and compared. On the basis of this study the rms -measurement is reclassified three categories: (1) Wave-form-error-free measurement (2) High-frequncy-error measurement and (3) Low-frequency error-free measurement. In modern digital sampled-data systems the signals are complex and waveform-error-free rms measurement is highly appreciated. Among the three basic blocks of rms measuring device the squarer is the most important one. A squaring technique is selected, that permits shaping of the squarer error characteristic in such a way as to achieve waveform-errob free rms measurement. The squarer is designed, fabricated and tested. A hybrid rms measurement using an analog rms computing device and digital display combines the speed of analog techniques and the resolution and ease of measurement of digital techniques. An A/D converter is modified to perform the square-rooting operation. A 10-V rms voltmeter using the developed rms detector is fabricated and tested. The chapters two, three and four analyse the problems involved in rms measurement and present a comparative study of rms computing techniques and devices. The fifth chapter gives the details of the developed rms detector that permits wave-form-error free rms measurement. The sixth chapter, enumerates the the highlights of the thesis and suggests a list of future projects
Resumo:
Measurement is the act or the result of a quantitative comparison between a given quantity and a quantity of the same kind chosen as a unit. It is generally agreed that all measurements contain errors. In a measuring system where both a measuring instrument and a human being taking the measurement using a preset process, the measurement error could be due to the instrument, the process or the human being involved. The first part of the study is devoted to understanding the human errors in measurement. For that, selected person related and selected work related factors that could affect measurement errors have been identified. Though these are well known, the exact extent of the error and the extent of effect of different factors on human errors in measurement are less reported. Characterization of human errors in measurement is done by conducting an experimental study using different subjects, where the factors were changed one at a time and the measurements made by them recorded. From the pre‐experiment survey research studies, it is observed that the respondents could not give the correct answers to questions related to the correct values [extent] of human related measurement errors. This confirmed the fears expressed regarding lack of knowledge about the extent of human related measurement errors among professionals associated with quality. But in postexperiment phase of survey study, it is observed that the answers regarding the extent of human related measurement errors has improved significantly since the answer choices were provided based on the experimental study. It is hoped that this work will help users of measurement in practice to better understand and manage the phenomena of human related errors in measurement.
Resumo:
The problem of using information available from one variable X to make inferenceabout another Y is classical in many physical and social sciences. In statistics this isoften done via regression analysis where mean response is used to model the data. Onestipulates the model Y = µ(X) +ɛ. Here µ(X) is the mean response at the predictor variable value X = x, and ɛ = Y - µ(X) is the error. In classical regression analysis, both (X; Y ) are observable and one then proceeds to make inference about the mean response function µ(X). In practice there are numerous examples where X is not available, but a variable Z is observed which provides an estimate of X. As an example, consider the herbicidestudy of Rudemo, et al. [3] in which a nominal measured amount Z of herbicide was applied to a plant but the actual amount absorbed by the plant X is unobservable. As another example, from Wang [5], an epidemiologist studies the severity of a lung disease, Y , among the residents in a city in relation to the amount of certain air pollutants. The amount of the air pollutants Z can be measured at certain observation stations in the city, but the actual exposure of the residents to the pollutants, X, is unobservable and may vary randomly from the Z-values. In both cases X = Z+error: This is the so called Berkson measurement error model.In more classical measurement error model one observes an unbiased estimator W of X and stipulates the relation W = X + error: An example of this model occurs when assessing effect of nutrition X on a disease. Measuring nutrition intake precisely within 24 hours is almost impossible. There are many similar examples in agricultural or medical studies, see e.g., Carroll, Ruppert and Stefanski [1] and Fuller [2], , among others. In this talk we shall address the question of fitting a parametric model to the re-gression function µ(X) in the Berkson measurement error model: Y = µ(X) + ɛ; X = Z + η; where η and ɛ are random errors with E(ɛ) = 0, X and η are d-dimensional, and Z is the observable d-dimensional r.v.
Resumo:
Neuropeptid Y (NPY) ist ein potenter Neurotransmitter im zentralen und peripheren Nervensystem der Mammalia. Es ist an der Regulation einer Vielzahl von physiologischen Prozessen beteiligt und scheint auch im retino-tectalen Transfer des visuellen Systems von Anuren eine zentrale Funktion einzunehmen. Die Retina bildet die erste Funktionseinheit bei der Verarbeitung visuellen Inputs. Für die Weiterverarbeitung sind primär das Tectum opticum (TO) und das Praetectum verantwortlich. Es gilt als wahrscheinlich, dass der praetecto-tectale Transfer durch NPY inhibitorisch moduliert wird und damit wesentlichen Einfluss auf die visuelle Mustererkennung und die Dämpfung der tectalen Erregungsausbreitung hat. Die Applikation von NPY auf die Tectumoberfläche schwächt die anfängliche Erregungswelle visuell evozierter Feldpotenziale stark ab und NPY könnte somit Einfluss auf die Axonendknoten retinaler Ganglienzellen des Typs R2, R3 und auch R4 haben. Es können jedoch keine detaillierten Aussagen gemacht werden welche Neuronen in welchem Umfang daran beteiligt sind. Im Rahmen meiner Arbeit, sollte der Einfluss von NPY auf die Spike-Amplitude und die Spike-Rate retinaler Ganglienzellen R2 und R3 bei Bombina orientalis analysiert werden, da diese den größten Input bei der visuellen Mustererkennung liefern und unterschiedliche Funktionen in diesem neuronalen Netzwerk haben. Hierzu wurden visuell evozierte Aktionspotenziale von R2 und R3 Neuronen im TO von Bombina orientalis abgeleitet und mit Hilfe der Analysesoftware Spike 2 bearbeitet und analysiert. Es konnte nachgewiesen werden, dass die Spike-Amplituden der R2 Neuronen 20 min nach NPY Applikation auf die Tectumoberfläche reduziert werden. Nach einer Erholungsphase 10 min nach Beenden der NPY-Applikation konnte ein Wiederanstieg der Spike-Amplituden gemessen werden, 20 min nach Beenden der NPY-Applikation kam es zu einem Abfall der Spike-Amplituden dessen Ursache unbekannt ist. Ob es ein Artefakt ist oder ob es sich hierbei um einen spezifischen Effekt von R2 Neuronen handelt muss noch geklärt werden. Die Spike-Amplituden der R3 Neuronen waren bereits 10 min nach NPY-Applikation reduziert, ein weitere Abfall der Spike-Amplituden konnte nicht verzeichnet werden. 10 min nach Beenden der NPY-Applikation konnte ein Anstieg der Spike-Amplituden verzeichnet werden, der sich stetig fortsetzte. Bei beiden Neuronentypen wurden 20 min nach Beenden der NPY-Applikation Spike-Amplituden nahe der Ausgangsamplitudenhöhe gemessen. Aufgrund des Verlaufes der R3 Neuronen ist davon auszugehen, dass die Feldpotenziale eher durch R3 Neuronen als durch R2 Neuronen beeinflusst werden, da er dem der Feldpotenziale gleicht. Auch bei der Untersuchung der Spike-Raten konnte eine Beeinflussung durch NPY nachgewiesen werden. Die R2 Neuronen zeigten 10 min nach NPY-Applikation einen Abfall der Spike-Raten der sich nach 20 min weiter fortsetzte. 10 min nach Beenden der NPY-Applikation konnte ein Wiederanstieg der Spike-Raten verzeichnet werden der sich stetig fortsetzte, die Werte blieben jedoch deutlich unter den gemessenen Ausgangswerten ohne eine NPY-Beeinflussung. Bei den R3 Neuronen konnte ein Abfall der Spike-Raten deutlich zeitverzögert nachgewiesen werden. 20 min nach Beenden der NPY-Applikation konnte ein Anstieg der Spike-Rate verzeichnet werden, jedoch gab es keine signifikanten Unterschiede der Spike-Raten zu den Werten ohne NPY-Beeinflussung. Der Vergleich der R2 und R3 Neuronen zeigt, dass bei den der R2 Neuronen ein schnellerer Effekt von NPY nachweisbar ist als die den R3 Neuronen. Aufgrund der von mir nachgewiesene NPY-induzierte Spike-Amplitudenabnahme retinaler R2 und R3 Neuronen muss davon ausgegangen werden, dass die Reduktion der Feldpotential durch NPY eher auf den Einfluss anderer Neuronen als R2 und R3 Neuronen zurückzuführen ist. Weder bei den R2 noch bei den R3 Neuronen konnte eine so schnelle und so starke Beeinflussung der Spike- Amplituden verzeichnet werden. Weiterhin zeigen meine Ergebnisse neuronale Bestätigung der von Funke 2005 beschrieben geringeren Strahlungsintensität sowie der geringeren Glukosemetabolisierung bei der 14C-2-Desoxyglukose Technik. Dies ist in der Form nur auf den Einfluss von R2 und R3 Neuronen zurückzuführen. Die von mir erzielten Ergebnisse stützen die Hypothese, dass NPY den retino-tectalen Signaltransfer inhibitorisch steuert einhergehend mit einer reduzierten Ausschüttung des praetectotectalen Transmitters Glutamat und weisen darauf hin, dass NPY über zwei verschiedene second-messenger vermittelte Prozesse diesen Signaltransfer steuert. Interessant ist in diesem Zusammenhang, dass diese nachhaltige Beeinflussung der visuellen Informationsverarbeitung durch NPY bei Bombina orientalis einem phylogenetisch basalen Vertreter der Anuren nachgewiesen werden konnte. Dies lässt den Schluss zu, dass solche grundlegenden neurochemischen Effekte des retino-tectalen Informationsgefüges evolutionär konserviert sind.