931 resultados para statistical study
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to perform a physicochemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures. Twenty-eight polyurethane mandibles were uniformly sectioned on the left angle. These were divided into 4 groups: group Eng 1P, one 2.0-mm plate and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates, the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the Ti-15Mo alloy. Each group was subjected to linear vertical loading at the first molar on the plated side in a mechanical testing unit. Means and standard deviations were compared with respect to statistical significance using ANOVA. The chemical composition of the Ti-15Mo alloy was close to the nominal value. The mapping of Mo and Ti showed a homogeneous distribution. SEM of the screw revealed machining debris. For the plates, only the cpTi plate undergoes a surface treatment. The metallographic analysis reveals granular microstructure, from the thermomechanical trials. A statistically significant difference was found (P < 0.05) when the comparison between both internal fixation techniques was performed. The 2P technique showed better mechanical behavior than 1P.
Resumo:
Objective: To compare the healing and bony crest resorption at implants installed conventionally or applying an edentulous ridge expansion (ERE) technique in the maxilla.Material and methods: In six Labrador dogs, the first and second maxillary incisors were extracted bilaterally. In the left side of the maxilla (Test), the flaps were elevated and the buccal plate of the alveoli and septa was removed. After 3 months of healing, partial-thickness (split) flaps were dissected and the residual alveolar bone was exposed. In the right side of the maxilla, an implant was installed conventionally (Type IV; Control) while, in the left side, the ERE technique was adopted. Hence, an expansion of the buccal bony crest was obtained, and the implant was subsequently installed (Test). After 3 months of healing, biopsies were obtained and ground sections were prepared for histological analyses.Results: A buccal vertical resorption of the bony crest of 2.2 +/- 1.2 mm and 1.6 +/- 0.7 mm was found at the test and control sites, respectively. The difference, however, did not reach statistical significance. The coronal level of osseointegration at the buccal aspect was located at 3.1 +/- 1.0 mm and 2.2 +/- 0.7 mm from the implant shoulder at the test and control sites, respectively, the difference being statistically significant. The mean values of the mineralized bone-to-implant contact (MBIC%) ranged from 43% to 48% at the buccal and lingual sites. No differences reached statistical significance.Conclusions: Implants installed by applying an ERE technique may osseointegrate similarly to conventional implant installation. However, vertical and horizontal resorption of the displaced buccal bony wall occurred as well.
Resumo:
Objective: To study bony and soft tissue changes at implants installed in alveolar bony ridges of different widths.Material and methods: In 6 Labrador dogs, the mandibular premolars and first molars were extracted, and a buccal defect was created in the left side at the third and fourth premolars by removing the buccal bone and the inter-radicular and interdental septa. Three months after tooth extraction, full-thickness mucoperiosteal flaps were elevated, and implants were installed, two at the reduced (test) and two at the regular-sized ridges (control). Narrow or wide abutments were affixed to the implants. After 3 months, biopsies were harvested, and ground sections prepared for histological evaluation.Results: A higher vertical buccal bony crest resorption was found at the test (1.5 +/- 0.7 mm and 1.0 +/- 0.7 mm) compared to the control implants (1.0 +/- 0.5 mm and 0.7 +/- 0.4 mm), for both wide and narrow abutment sites. A higher horizontal alveolar resorption was identified at the control compared to the test implants. The difference was significant for narrow abutment sites. The peri-implant mucosa was more coronally positioned at the narrow abutment, in the test sites, while for the control sites, the mucosal adaptation was more coronal at the wide abutment sites. These differences, however, did not reach statistical significance.Conclusions: Implants installed in regular-sized alveolar ridges had a higher horizontal, but a lower vertical buccal bony crest resorption compared to implants installed in reduced alveolar ridges. Narrow abutments in reduced ridges as well as wide abutments in regular-sized ridges yielded less soft tissue recession compared to their counterparts.
Resumo:
Objective: To compare the hard tissue changes at implants installed applying edentulous ridge expansion (E.R.E.) at sites with a buccal bony wall thickness of 1 or 2 mm.Material and methods: In six Labrador dogs, the first and second maxillary incisors were extracted, and the buccal alveolar bony plates and septa were removed. After 3 months of healing, partial-thickness flaps were dissected, and the E.R.E. was applied bilaterally. Hence, an expansion of the buccal bony crest was obtained in both sides of the maxilla with a displacement of either a 1- or a 2-mm-wide buccal bony plate at the test and control sites, respectively. After 3 months of healing, biopsies were obtained for histological analyses.Results: A buccal vertical resorption of the alveolar crest of 2.3 +/- 0.8 and 2.1 +/- 1.1 mm, and a coronal level of osseointegration at the buccal aspect of 2.7 +/- 0.5 and 2.9 +/- 0.9 mm were found at the test (1 mm) and control (2 mm) sites, respectively. The differences did not reach statistical significance. The mean values of the mineralized bone-to-implant contact (MBIC%) ranged from 62% to 73% at the buccal and lingual sites. No statistically significant differences were found. Horizontal volume gains of 1.8 and 1.1 mm were observed at the test and control sites, respectively, and the difference being statistically significant.Conclusions: Implants installed using the E.R.E. technique yielded a high degree of osseointegration. It is suggested that the displacement of buccal bony plates of 1 mm thickness is preferable compared with that of wider dimensions.
Resumo:
The present study analyzes the repair process of autogenous bone graft in a block fixed with ethyl cyanoacrylate and 2-octyl cyanoacrylate adhesives in rat calvaria. Forty-eight rats, divided into 3 groups, received round osteotomies at the right parietal bone for the attainment of autogenous bone graft fragment, which was fixed at the opposite side to the donor site with ethyl cyanoacrylate (ethyl group) and 2-octyl cyanoacrylate (octyl group) adhesives. In the control group, bone fragment was only juxtaposed at the parietal bone surface without any fixation material. The animals were euthanized after 10 and 60 postoperative days. The calvariae were processed in a laboratory for the attainment of slides stained through the hematoxylin and eosin technique for histological and histometric analysis. The qualitative analysis showed a discrete inflammatory infiltrate in the control group and moderate inflammatory infiltrate in the ethyl and octyl groups at the 10-day period, which remained at the 60-day period, mainly in the octyl group. The bone fragment remained bonded to the recipient site through the adhesive, but graft incorporation was not observed in any of the specimens. Resorption was higher in the octyl group followed by the ethyl and control groups, both at the 10-and 60-day periods, but with no statistical significance (P < .05). Although promoting graft fixation and its maintenance at the recipient site, both studied adhesives did not allow the graft incorporation, producing a localized and discrete inflammatory reaction, which persisted at 60 days, being more intense in the octyl cyanoacrylate group.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the morphology and adhesion of blood components on root surfaces instrumented with piezoelectric ultrasonic Piezon Master Surgery. Methods 10 teeth were used in this study. The teeth had their proximal divided into four areas that received different treatments: Group 1: untreated control Group 2: scaling with manual instrument; Group 3: scaling with ultrasound; Group 4: Scaling with manual instruments and ultrasound. We obtained 20 samples, 10 of which were used to analyze the morphology and the other 10 were used for analysis of adhesion of blood components. The specimens were analyzed by scanning electron microscopy. Photomicrographs were analyzed by the scores of adhesion of blood components and the index of root morphology. The results were statistically by the Kruskall-Wallis and Mann-Whitney with a significance level of 95%. Results The morphological analysis showed that the Group 1 had a surface unchanged in relation to other groups (Group 1 X Group 2 = 0.0025; Group 1 X Group 3 = 0.0003; Group 1 X Group 4 = 0.0003) and Group 2 presented a smoother surface compared to Group 1 and groups instrumented with ultrasound (Group 2 X Group 3 = 0.0025; Group 2 X Group 4 = 0.0025) there were no statistical differences between the Groups 3 and 4. analysis of adhesion of blood components showed that the Groups 2, 3 and 4 had no statistically significant differences between themselves, but more biocompatible surfaces promoted the surface untreated control (Group 1 X Group 2 = 0.02; Group 1 X Group 3 = 0.04; Group 1 X Group 4 = 0.005). Conclusion The instrumentation with piezoelectric ultrasonic promoted an irregular root surface, but did not negatively affect the adhesion of blood components.
Resumo:
Objective: this study aimed to present the causes and prevalence of maxillofacial fractures that occurred in the region of Araraquara-SP – Brazil, during a 6-year period. Methods: information regarding age, gender, etiology, and maxillofacial fracture site, as well as type of radiographic examination were evaluated. Data were gathered from the radiographic examination and radiographic report of the Division of Dentomaxillofacial Radiology, and from charts of the Division of Oral and Maxillofacial Surgery of patients attending for maxillofacial fractures from 2004 to 2009. A descriptive statistical analysis was developed using Epi-Info 3.5.1. Results: from a total of 11,728 patients assisted, 407 patients presented maxillofacial fractures. The prevalent age ranged from 21 to 30 years old. From the total patients, 322 were men and 85 were women (ratio of men to women was 3.8:1). Panoramic radiography (n = 306) was most frequently used to observe maxillofacial fractures. Mandibular fractures were frequent in the body of the mandible (n = 127), followed by symphysis (n = 102), and the prevalent cause was traffic accidents (n = 161). Conclusion: more than half of affected individuals were younger than 40 years of age. The body of the mandible was the most common fracture location visualized by panoramic radiography for traffic accidents and fights.
Resumo:
The authors have studied the effect of four staining agents on the optical properties of esthetic restorative materials through translucency tests. Two commercial brands of composite resins were used: Point 4 (Kerr) and Charisma (Heraeus-Kulzer). The liquids tested were: wine, cola, chlorhexidine solution and nicotine solution. The translucency was measured at different periods of time: P0 – before immersion (baseline), P1 - 1 h after immersion, P2 - 2 h after immersion and successively, P3 – 24 h after immersion up to a period of 7 weeks. ANOVA statistical analysis was applied to the data (p < 0.05). The results lead to the following conclusions: (1) Composite resins submitted to the tested immersion mediums were stained, (2) the lower percentage of translucency was observed for nicotine containing solution, (3) The percentage of translucency decreased with the period of immersion.
Resumo:
OBJECTIVE: The aim of this study was to assess the time spent for direct (DBB - direct bracket bonding) and indirect (IBB - indirect bracket bonding) bracket bonding techniques. The time length of laboratorial (IBB) and clinical steps (DBB and IBB) as well as the prevalence of loose bracket after a 24-week follow-up were evaluated. METHODS: Seventeen patients (7 men and 10 women) with a mean age of 21 years, requiring orthodontic treatment were selected for this study. A total of 304 brackets were used (151 DBB and 153 IBB). The same bracket type and bonding material were used in both groups. Data were submitted to statistical analysis by Wilcoxon non-parametric test at 5% level of significance. RESULTS: Considering the total time length, the IBB technique was more time-consuming than the DBB (p < 0.001). However, considering only the clinical phase, the IBB took less time than the DBB (p < 0.001). There was no significant difference (p = 0.910) for the time spent during laboratorial positioning of the brackets and clinical session for IBB in comparison to the clinical procedure for DBB. Additionally, no difference was found as for the prevalence of loose bracket between both groups. CONCLUSION: the IBB can be suggested as a valid clinical procedure since the clinical session was faster and the total time spent for laboratorial positioning of the brackets and clinical procedure was similar to that of DBB. In addition, both approaches resulted in similar frequency of loose bracket.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A prospective clinical study of maxillary sinus lift procedures in the posterior region of the maxilla, using only blood clot as filling material, was conducted. Seventeen patients underwent a maxillary sinus lift procedure; 20 maxillary sinus regions were operated on and a total of 25 implants were placed. The sinus mucosa was lifted together with the anterior wall of the osteotomized maxilla and supported by the implants placed. Computed tomography (CT) scans were obtained immediately postoperative (T-initial) and at 3 (T-1) and 51(T-2) months postoperative for the measurement of linear bone height and bone density (by grey tones). Only one implant was lost in the first stage (96% success). After dental prosthesis placement and during up to 51 months of follow-up, no implant was lost (100% success, second stage). The difference in mean bone height between T-initial (5.94 mm) and T-1 (13.14 mm), and between T-initial and T-2 (11.57 mm), was statistically significant (both P < 0.001); comparison between T-1 and T-2 also presented a statistical difference (P < 0.001). Bone density had increased at the end of the period analyzed, but this was not statistically significant (P > 0.05). Thus, the maxillary sinus lift technique with immediate implant placement, filling with blood clot only, may be performed with a high success rate.
Resumo:
The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.