995 resultados para spectral image
Resumo:
The along-scan radiometric gradient causes severe interpretation problems in Landsat images of tropical forests. It creates a decreasing trend in pixel values with the column number of the image. In practical applications it has been corrected assuming the trend to be linear within structurally similar forests. This has improved the relation between floristic and remote sensing information, but just in some cases. I use 3 Landsat images and 105 floristic inventories to test the assumption of linearity, and to examine how the gradient and linear corrections affect the relation between floristic and Landsat data. Results suggest the gradient to be linear in infrared bands. Also, the relation between floristic and Landsat data could be conditioned by the distribution of the sampling sites and the direction in which images are mosaicked. Additionally, there seems to be a conjunction between the radiometric gradient and a natural east-west vegetation gradient common in Western Amazonia. This conjunction might have enhanced artificially correlations between field and remotely-sensed information in previous studies. Linear corrections may remove such artificial enhancement, but along with true and relevant spectral information about floristic patterns, because they can´t separate the radiometric gradient from a natural one.
Resumo:
I den första delen av den här avhandlingen presenteras en bildens genealogi. Den skildrar hur begreppen för bilden, seendet och jaget utvecklades i relation till varandra i en specifik vetenskaplig och filosofisk kontext. Berättelsen sträcker sig från den tidiga renässansen och det perspektivistiska måleriet, till fotografiets födelse och positivismen. Den här utvecklingen medförde en form av reduktionism i vilken jagets roll – betydelsen av den mänskliga psykologin, vårt omdöme, vår uppmärksamhet och vår vilja – blev förbisedd. Inom den här tanketraditionen uppstod en förskjutning, från en förståelse av bilden som en representation av det tredimensionella rummet på en tvådimensionell yta, till en uppfattning om bilden som en genomskinlig ruta, ett fönster ut mot världen. Idén om avbildningen som en neutral ”blick från ingenstans” kom att förstärka en skeptisk hållning till kommunikation, dialog och vittnesmål och därmed även undergräva vår tillit till varandra och följaktligen vår tillit till oss själva. I den andra delen erbjuder författaren ett alternativ till den tanketradition som behandlas i den första delen. Det som blev förbisett i uppfattningen om en blick från ingenstans var att bilden är ett hjälpmedel då vi bearbetar vårt synfält. Bilden hjälper oss att dela vår syn på saker. Genom den här uppgiften av att dela blir bilden riktningsgivande i våra försök att orientera oss i världen. Jag kan stå bredvid en annan människa och se vad hon ser, men jag vet inte nödvändigtvis hur hon uppfattar det vi ser. Bilden lägger till ett led i det här förhållandet eftersom den inte enbart visar vad den andra ser. När bilden fungerar som den skall visar den också hur den andra ser och på det här sättet blir bilden verksam. Den föreliggande avhandlingen kombinerar epistemologi med vetenskapshistoria och visuella kulturstudier, men dess huvudintresse är filosofiskt. Den befattar sig med filosofiska missförstånd angående avbildning som en mimetisk konstform, kunskap som domesticering och varseblivning som mottagning av data. ------------------------------------------------------ Tämän väitöskirjan ensimmäinen osa selvittää kuvakäsitteen genealogiaa. Se havainnollistaa miten kuvan, näkemisen ja minän käsitteet kehittyivät suhteessa toisiinsa. Kertomus ulottuu varhaisesta renessanssista ja perspektivistisestä maalaustaiteesta, positivismin aikakauteen ja valokuvan syntyyn. Tämä kehitys toi mukanaan reduktionismin jossa minän rooli – ihmisen psykologian merkitys, meidän arviointikyky, meidän huomiokyky sekä meidän tahtomme – vaipui unohduksiin. Ajatusmaailmassa tapahtui siirtymä, kuvan merkitys vaihtui käsityksestä jossa se on kolmiulotteisen tilan representaatio kaksiulotteisella pinnalla, käsitykseen jossa kuva on läpinäkyvä ruutu, ikkuna kohti maailmaa. Ajatus kuvasta neutraalin näkökulman kantajana vahvisti skeptistä suhtautumista kommunikaatiota, dialogisuutta ja subjektiivisuutta kohtaan. Tämä skeptisyys ilmentyi myös vahvana epäluottamuksena ihmiskeskeisyyttä ja toiseutta kohtaan. Toisessa osassa tekijä tarjoaa vaihtoehdon tälle skeptiselle ajatusmaailmalle jota tarkastellaan ensimmäisessä osassa. Kuva on myös väline joka auttaa meitä jäsentämään meidän näkökenttäämme. Se auttaa meitä jakamaan meidän käsityksiä toistemme kanssa. Tämä näkemisen jakamisen käytäntö on kuvan keskeinen tehtävä. Voin seistä toisen ihmisen vieressä ja nähdä samat asiat kuin hän, mutta en välttämättä ymmärrä miten hän näkee nämä asiat. Kuva lisää jotain olennaista tähän suhteeseen. Kun kuva toimii niin kun sen kuuluu toimia, se näyttää myös miten toinen näkee, tällä tavalla kuvasta tulee välittäjä. Tämä väitöskirja yhdistää epistemologiaa, tieteen historiaa ja visuaalisen kulttuurin tutkimusta, mutta sen pääasiallinen tavoite on filosofinen. Se käsittelee filosofisia väärinkäsityksiä koskien kuvan eideettisyyttä.
Resumo:
The aim of the present study was to measure full epidermal thickness, stratum corneum thickness, rete length, dermal papilla widening and suprapapillary epidermal thickness in psoriasis patients using a light microscope and computer-supported image analysis. The data obtained were analyzed in terms of patient age, type of psoriasis, total body surface area involvement, scalp and nail involvement, duration of psoriasis, and family history of the disease. The study was conducted on 64 patients and 57 controls whose skin biopsies were examined by light microscopy. The acquired microscopic images were transferred to a computer and measurements were made using image analysis. The skin biopsies, taken from different body areas, were examined for different parameters such as epidermal, corneal and suprapapillary epidermal thickness. The most prominent increase in thickness was detected in the palmar region. Corneal thickness was more pronounced in patients with scalp involvement than in patients without scalp involvement (t = -2.651, P = 0.008). The most prominent increase in rete length was observed in the knees (median: 491 µm, t = 10.117, P = 0.000). The difference in rete length between patients with a positive and a negative family history was significant (t = -3.334, P = 0.03), being 27% greater in psoriasis patients without a family history. The differences in dermal papilla distances among patients were very small. We conclude that microscope-supported thickness measurements provide objective results.
Resumo:
The aim of the present study was to assess the spectral behavior of the erector spinae muscle during isometric contractions performed before and after a dynamic manual load-lifting test carried out by the trunk in order to determine the capacity of muscle to perform this task. Nine healthy female students participated in the experiment. Their average age, height, and body mass (± SD) were 20 ± 1 years, 1.6 ± 0.03 m, and 53 ± 4 kg, respectively. The development of muscle fatigue was assessed by spectral analysis (median frequency) and root mean square with time. The test consisted of repeated bending movements from the trunk, starting from a 45º angle of flexion, with the application of approximately 15, 25 and 50% of maximum individual load, to the stand up position. The protocol used proved to be more reliable with loads exceeding 50% of the maximum for the identification of muscle fatigue by electromyography as a function of time. Most of the volunteers showed an increase in root mean square versus time on both the right (N = 7) and the left (N = 6) side, indicating a tendency to become fatigued. With respect to the changes in median frequency of the electromyographic signal, the loads used in this study had no significant effect on either the right or the left side of the erector spinae muscle at this frequency, suggesting that a higher amount and percentage of loads would produce more substantial results in the study of isotonic contractions.
Resumo:
The objective of the present study was to perform a spectral analysis of the electrical activity of the left colon of patients with hepatosplenic schistosomiasis. Thirty patients were studied, divided into 2 groups: group A was composed of 14 patients (9 males and 5 females) with hepatosplenic schistosomiasis and group B was composed of 16 female patients without schistosomiasis mansoni. Three pairs of electrodes were implanted in the left colon at the moment of the surgical treatment. The signals of the electric activity of the colon were captured after postoperative recovery from the ileus and fed into a computer by means of a DATAQ data collection system which identified and captured frequencies between 0.02 and 10 Hz. Data were recorded, stored and analyzed using the WINDAQ 200 software. For electrical analysis, the average voltage of the electrical wave in the three electrodes of all patients, expressed as millivolts (mV), was considered, together with the maximum and minimum values, the root mean square (RMS), the skewness, and the results of the fast Fourier transforms. The average RMS of the schistosomiasis mansoni patients was 284.007 mV. During a long period of contraction, the RMS increased in a statistically significant manner from 127.455 mV during a resting period to 748.959 mV in patients with schistosomiasis mansoni. We conclude that there were no statistically significant differences in RMS values between patients with schistosomiasis mansoni and patients without the disease during the rest period or during a long period of contraction.
Resumo:
The Saimaa ringed seal is one of the most endangered seals in the world. It is a symbol of Lake Saimaa and a lot of effort have been applied to save it. Traditional methods of seal monitoring include capturing the animals and installing sensors on their bodies. These invasive methods for identifying can be painful and affect the behavior of the animals. Automatic identification of seals using computer vision provides a more humane method for the monitoring. This Master's thesis focuses on automatic image-based identification of the Saimaa ringed seals. This consists of detection and segmentation of a seal in an image, analysis of its ring patterns, and identification of the detected seal based on the features of the ring patterns. The proposed algorithm is evaluated with a dataset of 131 individual seals. Based on the experiments with 363 images, 81\% of the images were successfully segmented automatically. Furthermore, a new approach for interactive identification of Saimaa ringed seals is proposed. The results of this research are a starting point for future research in the topic of seal photo-identification.
Resumo:
Acute otitis media (AOM) is the most prevalent bacterial infection among children. Tympanometry and spectral gradient acoustic reflectometry (SG-AR) are adjunctive diagnostic tools to pneumatic otoscopy. The aim was to investigate the diagnostic accuracy and success rates of tympanometry and SG-AR performed by physicians and nurses. The study populations comprised 515 (I-II), 281 (III), and 156 (IV) outpatients (6-35 months). Physicians performed 4246 tympanometric (I) and SG-AR (II) examinations. Nurses performed 1782 (III) and 753 (IV) examinations at symptomatic and asymptomatic visits, respectively. Pneumatic otoscopy by the physician was the diagnostic standard. The accuracy of test results by physicians or nurses (I-IV) and the proportion of visits with accurate exclusive test results from both ears (III-IV) were analyzed. Type B tympanogram and SG-AR level 5 (<49˚) predicted middle ear effusion (MEE). At asymptomatic visits, type A and C1 tympanograms (peak pressure > -200 daPa) and SG-AR level 1 (>95˚) indicated healthy middle ear. Negative predictive values of type A and C1 tympanograms by nurses in excluding AOM at symptomatic and MEE at asymptomatic visits were 94% and 95%, respectively. Nurses obtained type A or C1 tympanogram from both ears at 94/459 (20%) and 81/196 (41%) of symptomatic and asymptomatic visits, respectively. SG-AR level 1 was rarely obtained from both ears. Type A and C1 tympanograms were accurate in excluding AOM at symptomatic and MEE at asymptomatic visits. However, nurses obtained these tympanograms from both ears only at one fifth of symptomatic visits and less than half of asymptomatic visits.
Resumo:
The present report describes the development of a technique for automatic wheezing recognition in digitally recorded lung sounds. This method is based on the extraction and processing of spectral information from the respiratory cycle and the use of these data for user feedback and automatic recognition. The respiratory cycle is first pre-processed, in order to normalize its spectral information, and its spectrogram is then computed. After this procedure, the spectrogram image is processed by a two-dimensional convolution filter and a half-threshold in order to increase the contrast and isolate its highest amplitude components, respectively. Thus, in order to generate more compressed data to automatic recognition, the spectral projection from the processed spectrogram is computed and stored as an array. The higher magnitude values of the array and its respective spectral values are then located and used as inputs to a multi-layer perceptron artificial neural network, which results an automatic indication about the presence of wheezes. For validation of the methodology, lung sounds recorded from three different repositories were used. The results show that the proposed technique achieves 84.82% accuracy in the detection of wheezing for an isolated respiratory cycle and 92.86% accuracy for the detection of wheezes when detection is carried out using groups of respiratory cycles obtained from the same person. Also, the system presents the original recorded sound and the post-processed spectrogram image for the user to draw his own conclusions from the data.
Resumo:
The objective of this study was to use linear and non-linear methods to investigate cardiac autonomic modulation in healthy elderly men and women in response to a postural change from the supine to the standing position. Fourteen men (66.1 ± 3.5 years) and 10 women (65.3 ± 3.3 years) were evaluated. Beat-to-beat heart rate was recorded in the supine and standing positions. Heart rate variability was studied by spectral analysis, including both low (LFnu-cardiac sympathetic modulation (CSM) indicator) and high (HFnu-cardiac vagal modulation (CVM) indicator) frequencies in normalized units as well as the low frequency/high frequency (LF/HF) ratio. Symbolic analysis was performed using the following indexes: 0V% (CSM indicator), 1V% (CSM and CVM indicators), 2LV% (predominantly CVM indicator) and 2ULV% (CVM indicator). Shannon entropy was also calculated. Men presented higher LFnu and LF/HF ratio and lower HFnu and 1V% symbolic index (57.56, 4.14, 40.53, 45.96, respectively) than women (24.60, 0.45, 72.47, 52.69, respectively) in the supine position. Shannon entropy was higher among men (3.53) than among women (3.33) in the standing position, and also increased according to postural change in men (3.25; 3.53). During postural change, the LFnu (24.60; 49.85) and LF/HF ratio (0.45; 1.72) increased, with a concomitant decrease in HFnu (72.47; 47.56) and 2LV% (14.10; 6.95) in women. Women presented increased CSM in response to postural change and had higher CVM and lower CSM than men in the supine position. In conclusion, women in the age range studied presented a more appropriate response to a postural change than men, suggesting that cardiac autonomic modulation may be better preserved in women than in men.
Resumo:
The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.