984 resultados para nitrous oxide yield
Resumo:
OBJECTIVES: To evaluate the use of inhaled nitric oxide (NO) in the management of persistent pulmonary hypertension of the newborn. METHODS: Computerized bibliographic search on MEDLINE, CURRENT CONTENTS and LILACS covering the period from January 1990 to March 1998; review of references of all papers found on the subject. Only randomized clinical trials evaluating nitric oxide and conventional treatment were included. OUTCOMES STUDIED: death, requirement for extracorporeal membrane oxygenation (ECMO), systemic oxygenation, complications at the central nervous system and development of chronic pulmonary disease. The methodologic quality of the studies was evaluated by a quality score system, on a scale of 13 points. RESULTS: For infants without congenital diaphragmatic hernia, inhaled NO did not change mortality (typical odds ratio: 1.04; 95% CI: 0.6 to 1.8); the need for ECMO was reduced (relative risk: 0.73; 95% CI: 0.60 to 0.90), and the oxygenation was improved (PaO2 by a mean of 53.3 mm Hg; 95% CI: 44.8 to 61.4; oxygenation index by a mean of -12.2; 95% CI: -14.1 to -9.9). For infants with congenital diaphragmatic hernia, mortality, requirement for ECMO, and oxygenation were not changed. For all infants, central nervous system complications and incidence of chronic pulmonary disease did not change. CONCLUSIONS: Inhaled NO improves oxygenation and reduces requirement for ECMO only in newborns with persistent pulmonary hypertension who do not have diaphragmatic hernia. The risk of complications of the central nervous system and chronic pulmonary disease were not affected by inhaled NO.
Resumo:
This work reviews the recent research on ion and UV irradiation of β-
Resumo:
Transparent conducting oxides (TCOs) have been largely used in the optoelectronic industry due to their singular combination of low electrical resistivity and high optical transmittance. They are usually deposited by magnetron sputtering systems being applied in several devices, specifically thin film solar cells (TFSCs). Sputtering targets are crucial components of the sputtering process, with many of the sputtered films properties dependent on the targets characteristics. The present thesis focuses on the development of high quality conductive Al-doped ZnO (AZO) ceramic sputtering targets based on nanostructured powders produced by emulsion detonation synthesis method (EDSM), and their application as a TCO. In this sense, the influence of several processing parameters was investigated from the targets raw-materials synthesis to the application of sputtered films in optoelectronic devices. The optimized manufactured AZO targets present a final density above 99 % with controlled grain size, an homogeneous microstructure with a well dispersed ZnAl2O4 spinel phase, and electrical resistivities of ~4 × 10-4 Ωcm independently on the Al-doping level among 0.5 and 2.0 wt. % Al2O3. Sintering conditions proved to have a great influence on the properties of the targets and their performance as a sputtering target. It was demonstrated that both deposition process and final properties of the films are related with the targets characteristics, which in turn depends on the initial powder properties. In parallel, the influence of several deposition parameters in the film´s properties sputtered from these targets was investigated. The sputtered AZO TCOs showed electrical properties at room temperature that are superior to simple oxides and comparable to a reference TCO – indium tin oxide (ITO), namely low electrical resistivity of 5.45 × 10-4 Ωcm, high carrier mobility (29.4 cm2V-1s-1), and high charge carrier concentration (3.97 × 1020 cm-3), and also average transmittance in the visible region > 80 %. These superior properties allowed their successful application in different optoelectronic devices.
Resumo:
Equity research report
Resumo:
RESUMO - Os nanomateriais manufaturados (NMs), isto é, fabricados deliberadamente para fins específicos, apresentam propriedades físico-químicas únicas como a dimensão, área superficial ou funcionalização, que lhes conferem caraterísticas mecânicas, óticas, elétricas e magnéticas muito vantajosas para aplicações industriais e biomédicas. Efetivamente, a tecnologia baseada nos NMs, ou nanotecnologia, foi identificada como uma key enabling technology, impulsionadora do crescimento económico dos países industrializados, devido ao seu potencial para melhorar a qualidade e desempenho de muitos tipos de produtos e de processos. Contudo, a expansão da utilização de NMs contrasta com a insuficiente avaliação de risco para a saúde humana e para o ambiente, sendo considerados como um risco emergente para a saúde pública. As incertezas sobre a segurança dos NMs para a saúde pública advêm sobretudo de estudos epidemiológicos em humanos expostos a nanomateriais produzidos como consequência dos processos e atividades humanas e da poluição. Uma das principais preocupações relativamente aos efeitos adversos dos NMs na saúde humana é o seu potencial efeito carcinogénico, que é sugerido por alguns estudos experimentais, como no caso dos nanomateriais de dióxido de titânio ou dos nanotubos de carbono. Para avaliar em curto termo as propriedades carcinogénicas de um composto, utilizam-se frequentemente ensaios de genotoxicidade em linhas celulares de mamífero ou ensaios em modelos animais, em que se analisa uma variedade de lesões genéticas potencialmente relacionados com o processo de carcinogénese. No entanto, a investigação sobre as propriedades genotóxicas dos NMs não foi, até hoje, conclusiva. O presente estudo tem por objectivo principal caracterizar os efeitos genotóxicos associados à exposição a nanomateriais manufaturados, de forma a contribuir para a avaliação da sua segurança. Constituíram objectivos específicos deste estudo: i) avaliar a genotoxicidade dos NMs em três tipos de células humanas expostas in vitro: linfócitos humanos primários, linha celular de epitélio brônquico humano (BEAS-2B) e linha celular de adenocarcinoma epitelial de pulmão humano (A549); ii) avaliar a sua genotoxicidade num modelo de ratinho transgénico; iii) investigar alguns mecanismos de acção que poderão contribuir para a genotoxicidade dos nanomateriais, como a contribuição de lesões oxidativas para a genotoxicidade induzida pelos NMs in vitro, e a investigação da sua bioacumulação e localização celular in vivo. Foram analisados os efeitos genotóxicos associados à exposição a duas classes de NMs, dióxido de titânio e nanotubos de carbono de parede múltipla, bem como a um NM de óxido de zinco, candidato a ser utlilizado como controlo positivo de dimensão nanométrica. Os xx NMs utilizados foram previamente caracterizados com detalhe relativamente às suas características físico-químicas e também relativamente à sua dispersão em meio aquoso e no meio de cultura. A metodologia incluiu ensaios de citotoxicidade e de genotoxicidade in vitro, designadamente, ensaios de quebras no DNA (ensaio do cometa) e nos cromossomas (ensaio do micronúcleo) em células humanas expostas a várias concentrações de NMs, por comparação com células não expostas. Também foram realizados ensaios in vivo de quebras no DNA, quebras cromossómicas e ainda um ensaio de mutações em vários órgãos de grupos de ratinhos transgénicos LacZ, expostos por via intravenosa a duas doses de dióxido de titânio. Foi investigada a existência de uma relação dose-resposta após exposição das células humanas ou dos animais a NMs. A contribuição de lesões oxidativas para a genotoxicidade após exposição das células aos NMs in vitro foi explorada através do ensaio do cometa modificado com enzima. Realizaram-se estudos histológicos e citológicos para deteção e localização celular dos NMs nos órgãos-alvo dos ratinhos expostos in vivo. Os resultados demonstraram efeitos genotóxicos em alguns dos NMs analisados em células humanas. No entanto, os efeitos genotóxicos, quando positivos, foram em níveis reduzidos, ainda que superiores aos valores dos controlos, e a sua reprodutibilidade era dependente do sistema experimental utilizado. Para outros NMs, a evidência de genotoxicidade revelou-se equívoca, conduzindo à necessidade de esclarecimento através de ensaios in vivo. Para esse fim, recorreu-se a uma análise integrada de múltiplos parâmetros num modelo animal, o ratinho transgénico baseado em plasmídeo contendo o gene LacZ exposto a um NM de dióxido de titânio, NM-102. Embora tenha sido demonstrada a exposição e a acumulação do NM no fígado, não se observaram efeitos genotóxicos nem no fígado, nem no baço nem no sangue dos ratinhos expostos a esse NM. Neste estudo concluiu-se que algumas formas de dióxido de titânio e nanotubos de carbono de parede múltipla produzem efeitos genotóxicos em células humanas, contribuindo para o conjunto de evidências sobre o efeito genotóxico desses NMs. As diferenças observadas relativamente à genotoxicidade entre NMs do mesmo tipo, mas distintos em algumas das suas características físico-quimicas, aparentemente não são negligenciáveis, pelo que os resultados obtidos para um NM não devem ser generalizados ao grupo correspondente. Para além disso, a genotoxicidade equívoca verificada para o NM-102 em células humanas expostas in vitro, não foi confirmada no modelo in vivo, pelo que o valor preditivo da utilização dos ensaios in vitro para a identificação de NMs com efeitos genotóxicos (e portanto potencialmente carcinogénicos) ainda tem de ser esclarecido antes de ser possível extrapolar as conclusões para a saúde humana. Por sua vez, como a informação aqui produzida pelas metodologias in vitro e in vivo não reflete os efeitos de exposição continua ou prolongada, que poderá conduzir a efeitos genotóxicos distintos, esta xxi deverá ser complementada com outras linhas de evidência relativamente à segurança dos NMs. Perante a incerteza dos níveis de exposição real do organismo humano e do ambiente, a segurança da utilização dos NMs não pode ser garantida a longo prazo e, tendo em conta a elevada produção e utilização destes NMs, são prementes futuros estudos de monitorização ambiental e humana.
Resumo:
Polymer blends based on poly(vinylidene fluoride), PVDF and poly(ethylene oxide), PEO, with varying compositions have been prepared by solvent casting, the polymer blend films being obtained from solutions in dimethyl formamide at 70ºC. Under these conditions PVDF crystallizes from solution while PEO remains in the molten state. Then, PEO crystallizes from the melt confined by PVDF crystalls during cooling to room temperature. PVDF crystallized from DMF solutions adopt predominantly the electroactive β-phase (85%). Nevertheless when PEO is introduced in the polymer blend the β-phase content decreases slightly to 70%. The piezoelectric coefficient (d33) in pristine PVDF is -5 pC/N and decreases with increasing PEO content in the PVDF/PEO blends. Blend morphology, observed by electron and atomic force microscopy, shows the confinement of PEO between the already formed PVDF crystals. On the other hand the sample contraction when PEO is extracted from the blend with water (which is not a solvent for PVDF) allows proving the co-continuity of both phases in the blend. PEO crystallization kinetics have been characterized by DSC both in isothermal and cooling scans experiments showing important differences in crystalline fraction and crystallization rate with sample composition.
Resumo:
Porous polymer membranes based on poly(vinylidene fluoride-trifluoroethylene)/poly(ethylene oxide) copolymers, P(VDF-TrFE)/PEO, are prepared through the, from partial to total, elimination of PEO, leading to interconnected micropores in the polymer blends. Electrolyte uptake, thermal and mechanical properties depend on the amount of PEO present in the polymer blend. Further, the degree of crystallinity of PEO and the elastic modulus (E´) of the polymer blend decrease with increasing PEO removal. Electrical properties of the polymer blend membranes are influenced by the porosity and are dominated by diffusion. The temperature dependence of ionic conductivity follows the Arrhenius behavior. It is the highest for the membranes with a volume fraction of pores of 44% (i.e, 90% PEO removal), reaching a value of 0.54 mS.cm-1 at room temperature. Battery performance was determined by assembling Li/C-LiFePO4 swagelok cells. The polymer blends with 90% PEO removal exhibit rate (124 mAhg-1 at C/5 and 47 mAhg-1 at 2C) and cycling capabilities suitable for lithium ion battery applications.
Resumo:
Stents are rigid and perforated tubular structures, which are inserted into blood vessels in order to prevent or inhibit the constriction of blood flow, restoring the normal blood flow, when blood vessels are clogged, being used in 70% of angioplasties. These medical devices assume great importance in the treatment of cardiovascular diseases (CVD) which are the leading cause of death worldwide. In the European Union CVD account for 40% of deaths and assume an estimated annual cost of 196 billion euros[1]. Stents must possess certain requirements, in order to, adequately, perform its function, such as biocompatibility (so that its use does not c ause damage on the health of its user), mechanical strength, radiopacity (so that it is easy to view), longitudinal flexibility, ease of handling, corrosion resistance and having high strength and high radial expansion ability to recover. Stents can be made of different materials, but metals, particularly stainless steel, are the most common. However, metallic stents present several dRawbacks such as corrosion and restenosis, leading to health complications for the patient, or even death. In order to minimize these disadvantages, new materials, like fibrous materials, have been used [2]. Monofilaments present high potential for stents development because, in addition to its biocompatibility, these materials allow the application of various surface treatments, such as antibacterial coatings. Furthermore, monofilament exhibit excellent mechanical properties, like greater stiffness and good results when subjected to compression, tensile and bending forces, since these forces will be directly supported by the monofilament [3]. To minimize the reaction of the human body and Limit the adhesion of microorganisms to the stent surface, some coatings have been developed, including the use of novel metals with antimicrobial properties, like silver. The main objective of this study was the development of fibrous stents, incorporation of silver oxide nanocoating. For the development of the stent, polyester monofilaments with 0.27mm of diameter were used in braiding technology, with a mandrel diameter of 6mm and a braiding angle of 35⁰. The mechanical behaviour of the stent were evaluated by mechanical testing under longitudinal and radial compression, bending. The results of compressive strength tests are according with value from literature: 1.13 to 2.9 N for radial compression and 0. 16-5.28N to longitudinal compression. From literature is also possible to verify that stents must present 75% of unchanged diameter during the bending test and must possess a porosity between 70% and 80% [4]. The produced polyester stent presents values of 1.29N for radial compression, 0.23N for longitudinal compression, 80% of porosity and 85.5% of unchanged diameter, during bending tests. For the antibacterial functionalization, silver oxide nanocoatings were prepared, through reactive magnetron g, with an Ag target in an Ar +O2 atmosphere. In order to evaluate the nanostructure and morphology of the coatings, d ifferent technique s like X-ray diffraction (XRD), scanning electron microscopy (SEM) and and X- ray photoelectron spectroscopy (XPS were used. From the analyses of XRD it is possible to verify that the peaks corresponds to planes of Ag2 O and MATERIAIS 2015 Porto, 21-23 June, 2015 characterize a cubic phase. The presence of Ag2 O is corroborated by XPS spectrum, where it is possible to observe silver, not only, in oxide state, but a lso in mettalic state, and it is possible to verify the presence of silver clusters, confirmed by SEM analysis. Films’ roughness and topography, parameters influencing the wettability of the surface and microorganism adhesion, were measured by Atomic Force Microscopy (AFM), and it was observed that the roughness is very low (under 10 nm). Coatings’ hydrophobicity and surface tension parameters were determined by contact angle measurement, and it was verified the hydrophobic behavior of the coatings. For antibacterial tests were used Staphylococcus epidermidis strain (IE186) and Staphylococcus aureus(ATCC 6538), and halo inhibition zone tests were realized. Ag+release rates were studied by means of inductively coupled plasma mass spectrometry (ICP -MS). The obtained results suggest that silver oxide coatings do not modify significantly surface properties of the substrate, like hydrophobicity and roughness, and present antimicrobial properties for both bacteria used.
Resumo:
Aniba canelilla (H.B.K.) Mez. is a tree species from Amazon that produces essential oil. The oil extraction from its leaves and stems can be an alternative way to avoid the tree cutting for production of essential oil. The aim of this study was to analyse factors that may influence the essential oil production and the biomass of resprouts after pruning the leaves and stems of A. canelilla trees. The tree crowns were pruned in the wet season and after nine months the leaves and stems of the remaining crown and the resprouts were collected, in the dry season. The results showed that the essential oil yield and chemical composition differed among the stems, leaves and resprouts. The stems' essential oil production differed between the seasons and had a higher production in the resprouting stems than the old stems of the remaining crown. The production of essential oil and leaf biomass of resprouts were differently related to the canopy openness, indicating that light increases the production of the essential oil and decreases the biomass of resprouting leaves. This study revealed that plant organs differ in their essential oil production and that the canopy openness must be taken into account when pruning the A. canelilla tree crown in order to achieve higher oil productivity.
Resumo:
The tropical tree Schizolobium amazonicum is native from the Amazonian forest, naturally occurring in Brazil, Peru and Colombia. This work aimed to study the veneer yield made from this species. For this purpose, 50 logs from S. amazonicum were rotary peeled in a plywood industry installed in Brazilian Amazon region. The results indicated that S. amazonicum had a peeling yield similar or even higher than those usually obtained for species traditionally used for this purpose in Brazil, like those of Pinus and Eucalyptus. It was also observed that the dendrometric parameters of the log can be used to estimate the peeling yield in this species.
Resumo:
Long pepper (Piper hispidinervum) is an Amazonian species of commercial interest due to the production of safrole. Drying long pepper biomass to extract safrole is a time consuming and costly process that can also result in the contamination of the material by microorganisms. The objective of this study was to analyze the yield of essential oil and safrole content of fresh and dried biomass of long pepper accessions maintained in the Active Germoplasm Bank of Embrapa Acre, in the state of Acre, Brazil, aiming at selecting genotypes with best performance on fresh biomass to recommend to the breeding program of the species. Yield of essential oil and safrole content were assessed in 15 long pepper accessions. The essential oil extraction was performed by hydrodistillation and analyzed by gas chromatography. A joint analysis of experiments was performed and the means of essential oil yield and safrole content for each biomass were compared by Student's t-test. There was variability in the essential oil yield and safrole content. There was no difference between the types of biomass for oil yield; however to the safrole content there was difference. Populations 9, 10, 12 and 15 had values of oil yield between 4.1 and 5.3%, and safrole content between 87.2 and 94.3%. The drying process does not interfere in oil productivity. These populations have potential for selection to the long pepper breeding program using oil extraction in the fresh biomass
Resumo:
Dissertação de mestrado em Biologia Molecular, Biotecnologia e Bioempreendedorismo em Plantas
Resumo:
This work describes the influence of a high annealing temperature of about 700C on the Si(substrate)/Si3N4/TiOx/Pt/LiCoO2 multilayer system for the fabrication of all-solid-state lithium ion thin film microbatteries. Such microbatteries typically utilize lithium cobalt oxide (LiCoO2) as cathode material with a platinum (Pt) current collector. Silicon nitride (Si3N4) is used to act as a barrier against Li diffusion into the substrate. For a good adherence between Si3N4 and Pt, commonly titanium (Ti) is used as intermediate layer. However, to achieve crystalline LiCoO2 the multilayer system has to be annealed at high temperature. This post-treatment initiates Ti diffusion into the Pt-collector and an oxidation to TiOx, leading to volume expansion and adhesion failures. To solve this adhesion problem, we introduce titanium oxide (TiOx) as an adhesion layer, avoiding the diffusion during the annealing process. LiCoO2, Pt and Si3N4 layers were deposited by magnetron sputtering and the TiOx layer by thermal oxidation of Ti layers deposited by e-beam technique. Asdeposited and annealed multilayer systems using various TiOx layer thicknesses were studied by scanning electron microscopy (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) and x-ray photoelectron spectroscopy (XPS). The results revealed that an annealing process at temperature of 700C leads to different interactions of Ti atoms between the layers, for various TiOx layer thicknesses (25–45 nm).
Resumo:
Background and aim: A significant proportion of patients presenting with obscure gastrointestinal bleeding (OGIB) have negative small bowel capsule endoscopy (SBCE) examinations, and yet remain at risk of rebleeding. We aimed to evaluate whether a second-look review of SBCE images using flexible spectral color enhancement (FICE) may improve the detection of potentially bleeding lesions. Materials and methods: This was a retrospective, single-center study including consecutive patients with OGIB subjected to SBCE, whose standard white light examination was nondiagnostic. Each SBCE was reviewed using FICE 1. New findings were labeled as either P1 or P2 lesions according to bleeding potential. Patients were followed up to assess the incidence of rebleeding. Results: A total of 42 consecutive patients were included. Sixteen patients (38%) experienced rebleeding after a mean follow-up of 26 months. Review of SBCE images using FICE 1 enabled the identification of previously unrecognized P2 lesions, mainly angioectasias, in nine patients (21%) and P1 lesions, mainly erosions, in 26 patients (62%). Among patients who experienced rebleeding, 13/16 (81%) were diagnosed with P1 lesions with FICE 1 (P=0.043), whereas 3/16 (19%) had confirmed nondiagnostic SBCE and only 1/16 (6%) had newly diagnosed P2 (plus P1) lesions. An alternative source of bleeding outside the small bowel was found in only 3/16 (19%) patients with rebleeding during the follow-up. Conclusion: In a significant proportion of patients with OGIB, FICE 1 may detect potentially bleeding lesions previously missed under conventional white light SBCE. Review of nondiagnostic SBCE with FICE 1 may be a valuable strategy to obviate the need for further investigations in patients with OGIB, particularly for those who experience rebleeding.
Resumo:
OBJECTIVE: To study the healing process of the myocardium in hypertensive rats undergoing inhibition of nitric oxide synthesis. METHODS: Two groups of animals were studied: one received L-NAME, 12mg/kg/day, and the other was a control group. The presence of type III collagen, fibronectin, and alpha-smooth muscle actin-positive cells was assessed by immunohistochemistry. RESULTS: Fibronectin was seen in both early and late lesions, while type III collagen was seen mainly in areas of incomplete healing, situated among myocytes and around the intramyocardial branches of the coronary arteries. Areas representing early and late lesions showed a population of spindle-shaped cells. Immunohistochemistry showed that these cells were positive for alpha-smooth muscle actin. CONCLUSION: In the myocardium of hypertensive rats, the alpha-smooth muscle actin-positive cells are related to the accumulation of type III collagen and fibronectin in the areas of myocardial damage.