972 resultados para intense exercise


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fast-electron generation and dynamics, including electron refluxing, is at the core of understanding high-intensity laser-plasma interactions. This field is itself of strong relevance to fast ignition fusion and the development of new short-pulse, intense, x-ray, gamma-ray, and particle sources. In this paper, we describe experiments that explicitly link fast-electron refluxing and anisotropy in hard-x-ray emission. We find the anisotropy in x-ray emission to be strongly correlated to the suppression of refluxing. In contrast to some previous work, the peak of emission is directly along the rear normal to the target rather than along either the incident laser direction or the specular reflection direction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the unequal spacing attosecond pulse trains from relativistic surface plasmas. The surface high harmonics efficiency is determined and could be enhanced using an optimized plasma scale length and density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Skeletal muscle wasting and weakness are significant complications of critical illness, associated with the degree of illness severity and periods of reduced mobility during mechanical ventilation. They contribute to the profound physical and functional deficits observed in survivors. These impairments may persist for many years following discharge from the intensive care unit (ICU) and may markedly influence health-related quality of life. Rehabilitation is a key strategy in the recovery of patients following critical illness. Exercise based interventions are aimed at targeting this muscle wasting and weakness. Physical rehabilitation delivered during ICU admission has been systematically evaluated and shown to be beneficial. However its effectiveness when initiated after ICU discharge has yet to be established. Objectives: To assess the effectiveness of exercise rehabilitation programmes, initiated after ICU discharge, on functional exercise capacity and health-related quality of life in adult ICU survivors who have been mechanically ventilated for more than 24 hours. Search methods:We searched the following databases: the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library), OvidSP MEDLINE, Ovid SP EMBASE, and CINAHL via EBSCO host to 15th May 2014. We used a specific search strategy for each database. This included synonyms for ICU and critical illness, exercise training and rehabilitation. We searched the reference lists of included studies and contacted primary authors to obtain further information regarding potentially eligible studies. We also searched major clinical trials registries (Clinical Trials and Current Controlled Trials) and the personal libraries of the review authors. We applied no language or publication restriction. We reran the search in February 2015. We will deal with any studies of interest when we update the review.  Selection criteria:We included randomized controlled trials (RCTs), quasi-RCTs, and controlled clinical trials (CCTs) that compared an exercise interventioninitiated after ICU discharge to any other intervention or a control or ‘usual care’ programme in adult (≥18years) survivors ofcritical illness. Data collection and analysis:We used standard methodological procedures expected by The Cochrane Collaboration. Main results:We included six trials (483 adult ICU participants). Exercise-based interventions were delivered on the ward in two studies; both onthe ward and in the community in one study; and in the community in three studies. The duration of the intervention varied according to the length of stay in hospital following ICU discharge (up to a fixed duration of 12 weeks).Risk of bias was variable for all domains across all trials. High risk of bias was evident in all studies for performance bias, although blinding of participants and personnel in therapeutic rehabilitation trials can be pragmatically challenging. Low risk of bias was at least 50% for all other domains across all trials, although high risk of bias was present in one study for random sequence generation (selection bias), incomplete outcome data (attrition bias) and other sources. Risk of bias was unclear for remaining studies across the domains.All six studies measured effect on the primary outcome of functional exercise capacity, although there was wide variability in natureof intervention, outcome measures and associated metrics, and data reporting. Overall quality of the evidence was very low. Only two studies using the same outcome measure for functional exercise capacity, had the potential for pooling of data and assessment of heterogeneity. On statistical advice, this was considered inappropriate to perform this analysis and study findings were therefore qualitatively described. Individually, three studies reported positive results in favour of the intervention. A small benefit (versus. control)was evident in anaerobic threshold in one study (mean difference, MD (95% confidence interval, CI), 1.8 mlO2/kg/min (0.4 to 3.2),P value = 0.02), although this effect was short-term, and in a second study, both incremental (MD 4.7 (95% CI 1.69 to 7.75) Watts, P value = 0.003) and endurance (MD 4.12 (95% CI 0.68 to 7.56) minutes, P value = 0.021) exercise testing demonstrated improvement.Finally self-reported physical function increased significantly following a rehabilitation manual (P value = 0.006). Remaining studies found no effect of the intervention.Similar variability in with regard findings for the primary outcome of health-related quality of life were also evident. Only two studies evaluated this outcome. Following statistical advice, these data again were considered inappropriate for pooling to determine overall effect and assessment of heterogeneity. Qualitative description of findings was therefore undertaken. Individually, neither study reported differences between intervention and control groups for health-related quality of life as a result of the intervention. Overall quality of the evidence was very low.Mortality was reported by all studies, ranging from 0% to 18.8%. Only one non-mortality adverse event was reported across all patients in all studies (a minor musculoskeletal injury). Withdrawals, reported in four studies, ranged from 0% to 26.5% in control groups,and 8.2% to 27.6% in intervention groups. Loss to follow-up, reported in all studies, ranged from 0% to 14% in control groups, and 0% to 12.5% in intervention groups. Authors’ conclusions:We are unable, at this time, to determine an overall effect on functional exercise capacity, or health-related quality of life, of an exercise based intervention initiated after ICU discharge in survivors of critical illness. Meta-analysis of findings was not appropriate. This was due to insufficient study number and data. Individual study findings were inconsistent. Some studies reported a beneficial effect of the intervention on functional exercise capacity, and others not. No effect was reported on health-related quality of life. Methodological rigour was lacking across a number of domains influencing quality of the evidence. There was also wide variability in the characteristics of interventions, outcome measures and associated metrics, and data reporting.If further trials are identified, we may be able to determine the effect of exercise-based interventions following ICU discharge, on functional exercise capacity and health-related quality of life in survivors of critical illness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the unequal spacing attosecond pulse trains from relativistic surface plasmas. The surface high harmonics efficiency is determined and could be enhanced using an optimized plasma scale length and density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aluminium targets were irradiated with 92 eV radiation from FLASH Free Electron Laser at DESY at intensities up to 10(17)W/cm(2) by focussing the beam on target down to a spot size of similar to 1 mu m by means of a parabolic mirror. High resolution XUV spectroscopy was used to identify aluminium emission from complex hole-states. Simulations carried out with the MARIA code show that the emission characterizes the electron heating in the transition phase solid-atomic. The analysis allows constructing a simple model of electron heating via Auger electrons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Exercise training is considered an effective strategy to improve metabolic disease. Despite this, less is known regarding exercise training in the prevention and susceptibility of LDL subfraction oxidation, particularly in an aged population. 
Methods Eleven aged (55 ± 4 yrs) and twelve young (21 ± 2 yrs) participants were randomly separated into an experimental or control group as follows: young exercise (n = 6); young control (n = 6); aged exercise (n = 6) and aged control (n = 5). The participants assigned to the exercise groups performed 12 weeks of moderate intensity (55–65% VO2max) exercise training. Venous blood was extracted at baseline, and 48 h following 12 weeks of exercise and assayed for a range of metabolites associated with lipid composition and lipoprotein susceptibility to oxidation. 
Results Although there was no difference in the oxidation potential (time ½ max) of LDL I, II or III between groups at baseline (p > 0.05), there was an increase in time ½ max for LDL I following exercise within the aged exercise group (p < 0.05). Moreover, α-tocopherol concentration was selectively lower in the aged exercise group, compared to the young exercise at baseline. The lipid composition of LDL I, LDL II, LDL III, VLDL, HDL2, HDL3 and serum lipid hydroperoxides remained unchanged as a function of exercise training and ageing (p > 0.05). 
Conclusion The primary finding of this study demonstrates that adaptations in LDL resistance to oxidation occur following 12 weeks of exercise training in the aged, and this may be of clinical significance, as oxidation of LDL has been implicated in atherosclerosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New Findings

What is the central question of this study?Exercise performance is limited during hypoxia by a critical reduction in cerebral and skeletal tissue oxygenation. To what extent an elevation in systemic free radical accumulation contributes to microvascular deoxygenation and the corresponding reduction in maximal aerobic capacity remains unknown.What is the main finding and its importance?We show that altered free radical metabolism is not a limiting factor for exercise performance in hypoxia, providing important insight into the fundamental mechanisms involved in the control of vascular oxygen transport.

Exercise performance in hypoxia may be limited by a critical reduction in cerebral and skeletal tissue oxygenation, although the underlying mechanisms remain unclear. We examined whether increased systemic free radical accumulation during hypoxia would be associated with elevated microvascular deoxygenation and reduced maximal aerobic capacity (). Eleven healthy men were randomly assigned single-blind to an incremental semi-recumbent cycling test to determine  in both normoxia (21% O2) and hypoxia (12% O2) separated by a week. Continuous-wave near-infrared spectroscopy was employed to monitor concentration changes in oxy- and deoxyhaemoglobin in the left vastus lateralis muscle and frontal cerebral cortex. Antecubital venous blood samples were obtained at rest and at  to determine oxidative (ascorbate radical by electron paramagnetic resonance spectroscopy), nitrosative (nitric oxide metabolites by ozone-based chemiluminescence and 3-nitrotyrosine by enzyme-linked immunosorbent assay) and inflammatory stress biomarkers (soluble intercellular/vascular cell adhesion 1 molecules by enzyme-linked immunosorbent assay). Hypoxia was associated with increased cerebral and muscle tissue deoxygenation and lower  (P < 0.05 versus normoxia). Despite an exercise-induced increase in oxidative–nitrosative–inflammatory stress, hypoxia per se did not have an additive effect (P > 0.05 versus normoxia). Consequently, we failed to observe correlations between any metabolic, haemodynamic and cardiorespiratory parameters (P > 0.05). Collectively, these findings suggest that altered free radical metabolism cannot explain the elevated microvascular deoxygenation and corresponding lower  in hypoxia. Further research is required to determine whether free radicals when present in excess do indeed contribute to the premature termination of exercise in hypoxia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This preliminary investigation was designed to test the hypothesis that high intensity single-leg exercise can cause extensive cell DNA damage, which subsequently may affect the expression of the HO-1 gene. METHODS: Six (n=6) apparently healthy male participants (age 27 + 7 yrs, stature 174 + 12 cm, body mass 79 + 4 kg and BMI 24 + 4 kg/m2) completed 100 isolated and continuous maximal concentric contractions (minimum force = 200 N, speed of contraction = 60°/sec) of the rectus femoris muscle. Using a spring-loaded and reusable Magnum biopsy gun with a 16-gauge core disposable biopsy needle, skeletal muscle micro biopsy tissue samples were extracted at rest and following exercise. mRNA gene expression was determined via two-step quantitative real-time PCR using GAPDH as a reference gene. RESULTS: The average muscle force production was 379 + 179 N. High intensity exercise increased mitochondrial 8-OHdG concentration (P < 0.05 vs. rest) with a concomitant decrease in total antioxidant capacity (P < 0.05 vs. rest). Exercise also increased protein oxidation as quantified by protein carbonyl concentration (P < 0.05 vs. rest). HO-1 expression increased (> 2-fold change vs. rest) following exercise, and it is postulated that this change was not significant due to low subject numbers (P > 0.05). CONCLUSION: These preliminary findings tentatively suggest that maximal concentric muscle contractions can cause intracellular DNA damage with no apparent disruption to the expression of the antioxidant stress protein HO-1. Moreover, it is likely that cell oxidant stress is required to activate the signal transduction cascade related to the expression of HO-1. A large-scale study incorporating a greater subject number is warranted to fully elucidate this relationship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lycopene can exert antioxidant effects against peripheral and cellular oxidative stress and may be associated with reduced diabetic risk. Conversely, exercise-induced free radicals are thought to underpin many of the desirable whole-body adaptations following training and the use of antioxidants within the exercise model remains debatable. PURPOSE: To investigate the effect of lycopene supplementation on oxidative stress and glucose homeostasis following acute aerobic exercise. METHOD: Twenty-eight (n=28) apparently healthy male volunteers were recruited (age 24 ± 4 years; weight 78 ± 10 kg; height 178 ± 8 cm; 2max 40 ± 7 ml·kg-1 ·min-1 ) in a randomised, single blind, placebo-controlled study. Participants were required to attend the Laboratory on two occasions: prior to and following 6 weeks of supplementation of either 10mg lycopene (LG; n=15) or placebo (PG; n=13) followed by a bout of acute exercise for one hour at 65% 2max. Exogenous glucose oxidation was then measured on an isotope ratio mass spectrometer in a sub-group of participants (n=14) following exercise, by administration of a standard oral glucose tolerance test (OGTT; 75g glucose). Venous blood samples were drawn for measurement of oxidative stress parameters, plasma glucose and insulin. RESULTS: Plasma lycopene increased in LG only (0.01 ± 0.004 vs.0.02 ± 0.007 µmol/L; P <0.05) following supplementation and remained elevated post exercise compared to PG (0.01 ± 0.004 vs. 0.02 ± 0.009 µmol/L; P <0.05). There were no changes in other markers of oxidative stress (SOD, LOOHs, F2 ISP and Alkoxyl radical) either between or within the trials, (P >0.05, respectively). A main effect for an increase in insulin was observed two hours post OGTT in the sub-groups (Pooled data, P <0.05) but trends in the HOMA scores were evident with a 57% increase for LG (2.20 ± 1.84 vs. 5.14 ± 2.5; P >0.05) and an 11% decrease for PG (2.17 ± 1.06 vs. 1.94 ± 1.53; P >0.05). No change in plasma glucose was detected at any point, or after the OGTT (P >0.05). CONCLUSION: In healthy males, lycopene supplementation had no effect on post exercise levels of ROS or markers of lipid peroxidation, despite an increase in plasma lycopene. However, lycopene supplementation may affect post exercise insulin sensitivity in response to glucose consumption, but further parallel research is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many organic molecules have strong absorption bands which can be accessed by ultraviolet short pulse lasers to produce efficient ionization. This resonant multiphoton ionization scheme has already been exploited as an ionization source in time-of-flight mass spectrometers used for environmental trace analysis. In the present work we quantify the ultimate potential of this technique by measuring absolute ion yields produced from the interaction of 267 nm femtosecond laser pulses with the organic molecules indole and toluene, and gases Xe, N2 and O2. Using multiphoton ionization cross sections extracted from these results, we show that the laser pulse parameters required for real-time detection of aromatic molecules at concentrations of one part per trillion in air and a limit of detection of a few attomoles are achievable with presently available commercial laser systems. The potential applications for the analysis of human breath, blood and tissue samples are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detailed knowledge of fast electron energy transport following the interaction of ultrashort intense laser pulses is a key subject for fast ignition. This is a problem relevant to many areas of laser-plasma physics with particular importance to fast ignition and X-ray secondary source development, necessary for the development of large-scale facilities such as HiPER and ELI. Operating two orthogonal crystal spectrometers set at Bragg angles close to 45 degrees determines the X-ray s- and p-polarization ratio. From this ratio, it is possible to infer the velocity distribution function of the fast electron beam within the dense plasma. We report on results of polarization measurements at high density for sulphur and nickel buried layer targets in the high intensity range of 10(19) - 10(21) Wcm(-2). We observe at 45 degrees the Ly-alpha doublet using two sets of orthogonal highly-orientated pyrolytic graphite (HOPG) crystals set in 1(st) order for sulphur and 3(rd) order for nickel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Musculoskeletal (MSK) complaints are common within primary care (1) (2) (3) but some General Practitioners (GPs)/family physicians do not feel comfortable managing these symptoms (3), preferring to refer onto hospital specialists or Integrated Clinical Assessment and Treatment Services (ICATs). Long waiting times for hospital outpatient reviews are a major cause of patient inconvenience and complaints (4). We therefore aimed to establish a GP-ran MSK and sport and exercise medicine (SEM) clinic based within a Belfast GP surgery that would contribute to a sustainable improvement in managing these common conditions within primary care as well as reducing waiting times for patients with these conditions to see a specialist. This shift from hospital-based to community-based management is in-keeping with recent policy changes within the UK health-system, including Transforming Your Care within Northern Ireland (NI) (5). The GP-ran MSK and SEM clinic was held monthly within a Belfast GP practice, staffed by one GP with a specialist interest in MSK and SEM conditions and its performance was reviewed over a three month period. Parameters audited included cases seen, orthopaedic and x-ray referral rates and secondary care referrals comparing the GP practice’s performance to the same time period in the previous year as well as patient satisfaction questionnaires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the Fortran program SIMLA, which is designed for the study of charged particle dynamics in laser and other background fields. The dynamics can be determined classically via the Lorentz force and Landau–Lifshitz equations or, alternatively, via the simulation of photon emission events determined by strong-field quantum-electrodynamics amplitudes and implemented using Monte-Carlo routines. Multiple background fields can be included in the simulation and, where applicable, the propagation direction, field type (plane wave, focussed paraxial, constant crossed, or constant magnetic), and time envelope of each can be independently specified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Propagation of intense circularly polarized laser pulses in strongly magnetized inhomogeneous plasmas is investigated. It is shown that a left-hand circularly polarized laser pulse propagating up the density gradient of the plasma along the magnetic field is reflected at the left-cutoff density. However, a right-hand circularly polarized laser can penetrate up the density gradient deep into the plasma without cutoff or resonance and turbulently heat the electrons trapped in its wake. Results from particle-in-cell simulations are in good agreement with that from the theory. (c) 2015 AIP Publishing LLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem-Musculoskeletal (MSK) symptoms are common within primary care but some GPs are not comfortable managing these; waiting times for hospital appointments are a major cause of patients’ complaints. Current UK healthcare policies emphasise a need for more community-based management. We aimed to pilot an innovative general practice-based clinic to improve the management of MSK and Sport and Exercise Medicine (SEM) symptoms within general practice.

The approach-This project was conducted in an inner-city practice of approximately 9,000 patients and 5 GP partners. The practice commissioned a novel monthly 4-hour clinic staffed by one GP with a specialist interest in MSK and SEM conditions. Each patient was allocated a 20-minute appointment. All primary care staff within the practice could refer any patient for whom they considered hospital referral appropriate, with no specific exclusion criteria. Management plans included injection therapy, exercise prescription and onward referral. After three months (August-October 2014) numbers of consultations, sources of referral, reasons for referral and management outcomes were described; patient satisfaction was assessed by questionnaire, offered to 10 randomly selected patients by reception staff and self-completed by patients. Costs of the clinic were compared to current options.

Findings- All patients (14 males; 21 females; aged 35-77 years), were seen within four weeks of referral (one third of orthopaedic referrals in 2013 waited over 9 weeks for appointment). Most were referred from other GPs; some came from physiotherapy and podiatry. Shoulder problems were the most frequent reason for referral. The commonest management option was steroid injection, with most patients being given advice regarding exercise and analgesia; there were 3 onward referrals (2 physiotherapy; 1 rheumatology).

Comparing August-October data in 2014 and 2013, total, orthopaedic and rheumatology referrals were reduced by 147, 2 and 3, respectively; within the practice MSK presentations and physiotherapy and x-ray referrals were 60, 47 and 90 fewer, respectively.

The cost per attendance at the clinic was £61; initial orthopaedic-ICAT assessments cost £82 and a consultant appointment £213.

Satisfaction questionnaires were returned by all 10 selected participants and provided positive feedback, expressing preference for community-based, rather than hospital, management.

Consequence- Our pilot study indicates that this novel service model has potential for efficient and effective management of MSK and SEM complaints in primary care, reducing the need for hospital referral and the clinical burden on general practices. The innovation deserves further evaluation in a full-scale trial to determine its generalisability to other practice settings and populations.