854 resultados para dynamic modeling and simulation
Resumo:
We present a novel framework for encoding latency analysis of arbitrary multiview video coding prediction structures. This framework avoids the need to consider an specific encoder architecture for encoding latency analysis by assuming an unlimited processing capacity on the multiview encoder. Under this assumption, only the influence of the prediction structure and the processing times have to be considered, and the encoding latency is solved systematically by means of a graph model. The results obtained with this model are valid for a multiview encoder with sufficient processing capacity and serve as a lower bound otherwise. Furthermore, with the objective of low latency encoder design with low penalty on rate-distortion performance, the graph model allows us to identify the prediction relationships that add higher encoding latency to the encoder. Experimental results for JMVM prediction structures illustrate how low latency prediction structures with a low rate-distortion penalty can be derived in a systematic manner using the new model.
Resumo:
Current nanometer technologies suffer within-die parameter uncertainties, varying workload conditions, aging, and temperature effects that cause a serious reduction on yield and performance. In this scenario, monitoring, calibration, and dynamic adaptation become essential, demanding systems with a collection of multi purpose monitors and exposing the need for light-weight monitoring networks. This paper presents a new monitoring network paradigm able to perform an early prioritization of the information. This is achieved by the introduction of a new hierarchy level, the threshing level. Targeting it, we propose a time-domain signaling scheme over a single-wire that minimizes the network switching activity as well as the routing requirements. To validate our approach, we make a thorough analysis of the architectural trade-offs and expose two complete monitoring systems that suppose an area improvement of 40% and a power reduction of three orders of magnitude compared to previous works.
Resumo:
Light trapping is becoming of increasing importance in crystalline silicon solar cells as thinner wafers are used to reduce costs. In this work, we report on light trapping by rear-side diffraction gratings produced by nano-imprint lithography using interference lithography as the mastering technology. Gratings fabricated on crystalline silicon wafers are shown to provide significant absorption enhancements. Through a combination of optical measurement and simulation, it is shown that the crossed grating provides better absorption enhancement than the linear grating, and that the parasitic reflector absorption is reduced by planarizing the rear reflector, leading to an increase in the useful absorption in the silicon. Finally, electro-optical simulations are performed of solar cells employing the fabricated grating structures to estimate efficiency enhancement potential.
Resumo:
The Atomic Physics Group at the Institute of Nuclear Fusion (DENIM) in Spain has accumulated experience over the years in developing a collection of computational models and tools for determining some relevant microscopic properties of, mainly, ICF and laser-produced plasmas in a variety of conditions. In this work several applications of those models in determining some relevant microscopic properties are presented.
Resumo:
Mechanical degradation of tungsten alloys at extreme temperatures in vacuum and oxidation atmospheres.
Resumo:
Delamination reduces the strenght of the composites, mainly in compression. Several methods exist to overcome this problem, but they are either not feasible for large scale production or too expensive. 3D composites are a promising solution.
Resumo:
Background: In recent years, Spain has implemented a number of air quality control measures that are expected to lead to a future reduction in fine particle concentrations and an ensuing positive impact on public health. Objectives: We aimed to assess the impact on mortality attributable to a reduction in fine particle levels in Spain in 2014 in relation to the estimated level for 2007. Methods: To estimate exposure, we constructed fine particle distribution models for Spain for 2007 (reference scenario) and 2014 (projected scenario) with a spatial resolution of 16x16 km2. In a second step, we used the concentration-response functions proposed by cohort studies carried out in Europe (European Study of Cohorts for Air Pollution Effects and Rome longitudinal cohort) and North America (American Cancer Society cohort, Harvard Six Cities study and Canadian national cohort) to calculate the number of attributable annual deaths corresponding to all causes, all non-accidental causes, ischemic heart disease and lung cancer among persons aged over 25 years (2005-2007 mortality rate data). We examined the effect of the Spanish demographic shift in our analysis using 2007 and 2012 population figures. Results: Our model suggested that there would be a mean overall reduction in fine particle levels of 1mg/m3 by 2014. Taking into account 2007 population data, between 8 and 15 all-cause deaths per 100,000 population could be postponed annually by the expected reduction in fine particle levels. For specific subgroups, estimates varied from 10 to 30 deaths for all non-accidental causes, from 1 to 5 for lung cancer, and from 2 to 6 for ischemic heart disease. The expected burden of preventable mortality would be even higher in the future due to the Spanish population growth. Taking into account the population older than 30 years in 2012, the absolute mortality impact estimate would increase approximately by 18%. Conclusions: Effective implementation of air quality measures in Spain, in a scenario with a short-term projection, would amount to an appreciable decline infine particle concentrations, and this, in turn, would lead to notable health-related benefits. Recent European cohort studies strengthen the evidence of an association between long-term exposure to fine particles and health effects, and could enhance the health impact quantification in Europe. Air quality models can contribute to improved assessment of air pollution health impact estimates, particularly in study areas without air pollution monitoring data.
Resumo:
In this paper we focus on the selection of safeguards in a fuzzy risk analysis and management methodology for information systems (IS). Assets are connected by dependency relationships, and a failure of one asset may affect other assets. After computing impact and risk indicators associated with previously identified threats, we identify and apply safeguards to reduce risks in the IS by minimizing the transmission probabilities of failures throughout the asset network. However, as safeguards have associated costs, the aim is to select the safeguards that minimize costs while keeping the risk within acceptable levels. To do this, we propose a dynamic programming-based method that incorporates simulated annealing to tackle optimizations problems.
Resumo:
La metodología Integrated Safety Analysis (ISA), desarrollada en el área de Modelación y Simulación (MOSI) del Consejo de Seguridad Nuclear (CSN), es un método de Análisis Integrado de Seguridad que está siendo evaluado y analizado mediante diversas aplicaciones impulsadas por el CSN; el análisis integrado de seguridad, combina las técnicas evolucionadas de los análisis de seguridad al uso: deterministas y probabilistas. Se considera adecuado para sustentar la Regulación Informada por el Riesgo (RIR), actual enfoque dado a la seguridad nuclear y que está siendo desarrollado y aplicado en todo el mundo. En este contexto se enmarcan, los proyectos Safety Margin Action Plan (SMAP) y Safety Margin Assessment Application (SM2A), impulsados por el Comité para la Seguridad de las Instalaciones Nucleares (CSNI) de la Agencia de la Energía Nuclear (NEA) de la Organización para la Cooperación y el Desarrollo Económicos (OCDE) en el desarrollo del enfoque adecuado para el uso de las metodologías integradas en la evaluación del cambio en los márgenes de seguridad debidos a cambios en las condiciones de las centrales nucleares. El comité constituye un foro para el intercambio de información técnica y de colaboración entre las organizaciones miembro, que aportan sus propias ideas en investigación, desarrollo e ingeniería. La propuesta del CSN es la aplicación de la metodología ISA, especialmente adecuada para el análisis según el enfoque desarrollado en el proyecto SMAP que pretende obtener los valores best-estimate con incertidumbre de las variables de seguridad que son comparadas con los límites de seguridad, para obtener la frecuencia con la que éstos límites son superados. La ventaja que ofrece la ISA es que permite el análisis selectivo y discreto de los rangos de los parámetros inciertos que tienen mayor influencia en la superación de los límites de seguridad, o frecuencia de excedencia del límite, permitiendo así evaluar los cambios producidos por variaciones en el diseño u operación de la central que serían imperceptibles o complicados de cuantificar con otro tipo de metodologías. La ISA se engloba dentro de las metodologías de APS dinámico discreto que utilizan la generación de árboles de sucesos dinámicos (DET) y se basa en la Theory of Stimulated Dynamics (TSD), teoría de fiabilidad dinámica simplificada que permite la cuantificación del riesgo de cada una de las secuencias. Con la ISA se modelan y simulan todas las interacciones relevantes en una central: diseño, condiciones de operación, mantenimiento, actuaciones de los operadores, eventos estocásticos, etc. Por ello requiere la integración de códigos de: simulación termohidráulica y procedimientos de operación; delineación de árboles de sucesos; cuantificación de árboles de fallos y sucesos; tratamiento de incertidumbres e integración del riesgo. La tesis contiene la aplicación de la metodología ISA al análisis integrado del suceso iniciador de la pérdida del sistema de refrigeración de componentes (CCWS) que genera secuencias de pérdida de refrigerante del reactor a través de los sellos de las bombas principales del circuito de refrigerante del reactor (SLOCA). Se utiliza para probar el cambio en los márgenes, con respecto al límite de la máxima temperatura de pico de vaina (1477 K), que sería posible en virtud de un potencial aumento de potencia del 10 % en el reactor de agua a presión de la C.N. Zion. El trabajo realizado para la consecución de la tesis, fruto de la colaboración de la Escuela Técnica Superior de Ingenieros de Minas y Energía y la empresa de soluciones tecnológicas Ekergy Software S.L. (NFQ Solutions) con el área MOSI del CSN, ha sido la base para la contribución del CSN en el ejercicio SM2A. Este ejercicio ha sido utilizado como evaluación del desarrollo de algunas de las ideas, sugerencias, y los algoritmos detrás de la metodología ISA. Como resultado se ha obtenido un ligero aumento de la frecuencia de excedencia del daño (DEF) provocado por el aumento de potencia. Este resultado demuestra la viabilidad de la metodología ISA para obtener medidas de las variaciones en los márgenes de seguridad que han sido provocadas por modificaciones en la planta. También se ha mostrado que es especialmente adecuada en escenarios donde los eventos estocásticos o las actuaciones de recuperación o mitigación de los operadores pueden tener un papel relevante en el riesgo. Los resultados obtenidos no tienen validez más allá de la de mostrar la viabilidad de la metodología ISA. La central nuclear en la que se aplica el estudio está clausurada y la información relativa a sus análisis de seguridad es deficiente, por lo que han sido necesarias asunciones sin comprobación o aproximaciones basadas en estudios genéricos o de otras plantas. Se han establecido tres fases en el proceso de análisis: primero, obtención del árbol de sucesos dinámico de referencia; segundo, análisis de incertidumbres y obtención de los dominios de daño; y tercero, cuantificación del riesgo. Se han mostrado diversas aplicaciones de la metodología y ventajas que presenta frente al APS clásico. También se ha contribuido al desarrollo del prototipo de herramienta para la aplicación de la metodología ISA (SCAIS). ABSTRACT The Integrated Safety Analysis methodology (ISA), developed by the Consejo de Seguridad Nuclear (CSN), is being assessed in various applications encouraged by CSN. An Integrated Safety Analysis merges the evolved techniques of the usually applied safety analysis methodologies; deterministic and probabilistic. It is considered as a suitable tool for assessing risk in a Risk Informed Regulation framework, the approach under development that is being adopted on Nuclear Safety around the world. In this policy framework, the projects Safety Margin Action Plan (SMAP) and Safety Margin Assessment Application (SM2A), set up by the Committee on the Safety of Nuclear Installations (CSNI) of the Nuclear Energy Agency within the Organization for Economic Co-operation and Development (OECD), were aimed to obtain a methodology and its application for the integration of risk and safety margins in the assessment of the changes to the overall safety as a result of changes in the nuclear plant condition. The committee provides a forum for the exchange of technical information and cooperation among member organizations which contribute their respective approaches in research, development and engineering. The ISA methodology, proposed by CSN, specially fits with the SMAP approach that aims at obtaining Best Estimate Plus Uncertainty values of the safety variables to be compared with the safety limits. This makes it possible to obtain the exceedance frequencies of the safety limit. The ISA has the advantage over other methods of allowing the specific and discrete evaluation of the most influential uncertain parameters in the limit exceedance frequency. In this way the changes due to design or operation variation, imperceptibles or complicated to by quantified by other methods, are correctly evaluated. The ISA methodology is one of the discrete methodologies of the Dynamic PSA framework that uses the generation of dynamic event trees (DET). It is based on the Theory of Stimulated Dynamics (TSD), a simplified version of the theory of Probabilistic Dynamics that allows the risk quantification. The ISA models and simulates all the important interactions in a Nuclear Power Plant; design, operating conditions, maintenance, human actuations, stochastic events, etc. In order to that, it requires the integration of codes to obtain: Thermohydraulic and human actuations; Even trees delineation; Fault Trees and Event Trees quantification; Uncertainty analysis and risk assessment. This written dissertation narrates the application of the ISA methodology to the initiating event of the Loss of the Component Cooling System (CCWS) generating sequences of loss of reactor coolant through the seals of the reactor coolant pump (SLOCA). It is used to test the change in margins with respect to the maximum clad temperature limit (1477 K) that would be possible under a potential 10 % power up-rate effected in the pressurized water reactor of Zion NPP. The work done to achieve the thesis, fruit of the collaborative agreement of the School of Mining and Energy Engineering and the company of technological solutions Ekergy Software S.L. (NFQ Solutions) with de specialized modeling and simulation branch of the CSN, has been the basis for the contribution of the CSN in the exercise SM2A. This exercise has been used as an assessment of the development of some of the ideas, suggestions, and algorithms behind the ISA methodology. It has been obtained a slight increase in the Damage Exceedance Frequency (DEF) caused by the power up-rate. This result shows that ISA methodology allows quantifying the safety margin change when design modifications are performed in a NPP and is specially suitable for scenarios where stochastic events or human responses have an important role to prevent or mitigate the accidental consequences and the total risk. The results do not have any validity out of showing the viability of the methodology ISA. Zion NPP was retired and information of its safety analysis is scarce, so assumptions without verification or approximations based on generic studies have been required. Three phases are established in the analysis process: first, obtaining the reference dynamic event tree; second, uncertainty analysis and obtaining the damage domains; third, risk quantification. There have been shown various applications of the methodology and advantages over the classical PSA. It has also contributed to the development of the prototype tool for the implementation of the ISA methodology (SCAIS).
Resumo:
El propósito de esta tesis es presentar una metodología para realizar análisis de la dinámica en pequeña señal y el comportamiento de sistemas de alimentación distribuidos de corriente continua (CC), formados por módulos comerciales. Para ello se hace uso de un método sencillo que indica los márgenes de estabilidad menos conservadores posibles mediante un solo número. Este índice es calculado en cada una de las interfaces que componen el sistema y puede usarse para obtener un índice global que indica la estabilidad del sistema global. De esta manera se posibilita la comparación de sistemas de alimentación distribuidos en términos de robustez. La interconexión de convertidores CC-CC entre ellos y con los filtros EMI necesarios puede originar interacciones no deseadas que dan lugar a la degradación del comportamiento de los convertidores, haciendo el sistema más propenso a inestabilidades. Esta diferencia en el comportamiento se debe a interacciones entre las impedancias de los diversos elementos del sistema. En la mayoría de los casos, los sistemas de alimentación distribuida están formados por módulos comerciales cuya estructura interna es desconocida. Por ello los análisis presentados en esta tesis se basan en medidas de la respuesta en frecuencia del convertidor que pueden realizarse desde los terminales de entrada y salida del mismo. Utilizando las medidas de las impedancias de entrada y salida de los elementos del sistema, se puede construir una función de sensibilidad que proporciona los márgenes de estabilidad de las diferentes interfaces. En esta tesis se utiliza el concepto del valor máximo de la función de sensibilidad (MPC por sus siglas en inglés) para indicar los márgenes de estabilidad como un único número. Una vez que la estabilidad de todas las interfaces del sistema se han evaluado individualmente, los índices obtenidos pueden combinarse para obtener un único número con el que comparar la estabilidad de diferentes sistemas. Igualmente se han analizado las posibles interacciones en la entrada y la salida de los convertidores CC-CC, obteniéndose expresiones analíticas con las que describir en detalle los acoplamientos generados en el sistema. Los estudios analíticos realizados se han validado experimentalmente a lo largo de la tesis. El análisis presentado en esta tesis se culmina con la obtención de un índice que condensa los márgenes de estabilidad menos conservativos. También se demuestra que la robustez del sistema está asegurada si las impedancias utilizadas en la función de sensibilidad se obtienen justamente en la entrada o la salida del subsistema que está siendo analizado. Por otra parte, la tesis presenta un conjunto de parámetros internos asimilados a impedancias, junto con sus expresiones analíticas, que permiten una explicación detallada de las interacciones en el sistema. Dichas expresiones analíticas pueden obtenerse bien mediante las funciones de transferencia analíticas si se conoce la estructura interna, o utilizando medidas en frecuencia o identificación de las mismas a través de la respuesta temporal del convertidor. De acuerdo a las metodologías presentadas en esta tesis se puede predecir la estabilidad y el comportamiento de sistemas compuestos básicamente por convertidores CC-CC y filtros, cuya estructura interna es desconocida. La predicción se basa en un índice que condensa la información de los márgenes de estabilidad y que permite la obtención de un indicador de la estabilidad global de todo el sistema, permitiendo la comparación de la estabilidad de diferentes arquitecturas de sistemas de alimentación distribuidos. ABSTRACT The purpose of this thesis is to present dynamic small-signal stability and performance analysis methodology for dc-distributed systems consisting of commercial power modules. Furthermore, the objective is to introduce simple method to state the least conservative margins for robust stability as a single number. In addition, an index characterizing the overall system stability is obtained, based on which different dc-distributed systems can be compared in terms of robustness. The interconnected systems are prone to impedance-based interactions which might lead to transient-performance degradation or even instability. These systems typically are constructed using commercial converters with unknown internal structure. Therefore, the analysis presented throughout this thesis is based on frequency responses measurable from the input and output terminals. The stability margins are stated utilizing a concept of maximum peak criteria, derived from the behavior of impedance-based sensitivity function that provides a single number to state robust stability. Using this concept, the stability information at every system interface is combined to a meaningful number to state the average robustness of the system. In addition, theoretical formulas are extracted to assess source and load side interactions in order to describe detailed couplings within the system. The presented theoretical analysis methodologies are experimentally validated throughout the thesis. In this thesis, according to the presented analysis, the least conservative stability margins are provided as a single number guaranteeing robustness. It is also shown that within the interconnected system the robust stability is ensured only if the impedance-based minor-loop gain is determined at the very input or output of each subsystem. Moreover, a complete set of impedance-type internal parameters as well as the formulas according to which the interaction sensitivity can be fully explained and analyzed, is provided. The given formulation can be utilized equally either based on measured frequency responses, time-domain identified internal parameters or extracted analytic transfer functions. Based on the analysis methodologies presented in this thesis, the stability and performance of interconnected systems consisting of converters with unknown internal structure, can be predicted. Moreover, the provided concept to assess the least conservative stability margins enables to obtain an index to state the overall robust stability of distributed power architecture and thus to compare different systems in terms of stability.
Resumo:
Over the last few years, the Data Center market has increased exponentially and this tendency continues today. As a direct consequence of this trend, the industry is pushing the development and implementation of different new technologies that would improve the energy consumption efficiency of data centers. An adaptive dashboard would allow the user to monitor the most important parameters of a data center in real time. For that reason, monitoring companies work with IoT big data filtering tools and cloud computing systems to handle the amounts of data obtained from the sensors placed in a data center.Analyzing the market trends in this field we can affirm that the study of predictive algorithms has become an essential area for competitive IT companies. Complex algorithms are used to forecast risk situations based on historical data and warn the user in case of danger. Considering that several different users will interact with this dashboard from IT experts or maintenance staff to accounting managers, it is vital to personalize it automatically. Following that line of though, the dashboard should only show relevant metrics to the user in different formats like overlapped maps or representative graphs among others. These maps will show all the information needed in a visual and easy-to-evaluate way. To sum up, this dashboard will allow the user to visualize and control a wide range of variables. Monitoring essential factors such as average temperature, gradients or hotspots as well as energy and power consumption and savings by rack or building would allow the client to understand how his equipment is behaving, helping him to optimize the energy consumption and efficiency of the racks. It also would help him to prevent possible damages in the equipment with predictive high-tech algorithms.
Resumo:
The dynamic characteristics of reflex eye movements were measured in two strains of chronically prepared mice by using an infrared television camera system. The horizontal vestibulo-ocular reflex (HVOR) and horizontal optokinetic response (HOKR) were induced by sinusoidal oscillations of a turntable, in darkness, by 10° (peak to peak) at 0.11–0.50 Hz and of a checked-pattern screen, in light, by 5–20°at 0.11–0.17 Hz, respectively. The gains and phases of the HVOR and HOKR of the C57BL/6 mice were nearly equivalent to those of rabbits and rats, whereas the 129/Sv mice exhibited very low gains in the HVOR and moderate phase lags in the HOKR, suggesting an inherent sensory-motor anomaly. Adaptability of the HOKR was examined in C57BL/6 mice by sustained screen oscillation. When the screen was oscillated by 10° at 0.17 Hz, which induced sufficient retinal slips, the gain of the HOKR increased by 0.08 in 1 h on average, whereas the stimuli that induced relatively small or no retinal slips affected the gain very little. Lesions of the flocculi induced by local applications of 0.1% ibotenic acid and lesions of the inferior olivary nuclei induced by i.p. injection of 3-acetylpyridine in C57BL/6 mice little affected the dynamic characteristics of the HVOR and HOKR, but abolished the adaptation of the HOKR. These results indicate that the olivo-floccular system plays an essential role in the adaptive control of the ocular reflex in mice, as suggested in other animal species. The data presented provide the basis for analyzing the reflex eye movements of genetically engineered mice.
Resumo:
Centrosome duplication and separation are of central importance for cell division. Here we provide a detailed account of this dynamic process in Dictyostelium. Centrosome behavior was monitored in living cells using a γ-tubulin–green fluorescent protein construct and correlated with morphological changes at the ultrastructural level. All aspects of the duplication and separation process of this centrosome are unusual when compared with, e.g., vertebrate cells. In interphase the Dictyostelium centrosome is a box-shaped structure comprised of three major layers, surrounded by an amorphous corona from which microtubules emerge. Structural duplication takes place during prophase, as opposed to G1/S in vertebrate cells. The three layers of the box-shaped core structure increase in size. The surrounding corona is lost, an event accompanied by a decrease in signal intensity of γ-tubulin–green fluorescent protein at the centrosome and the breakdown of the interphase microtubule system. At the prophase/prometaphase transition the separation into two mitotic centrosomes takes place via an intriguing lengthwise splitting process where the two outer layers of the prophase centrosome peel away from each other and become the mitotic centrosomes. Spindle microtubules are now nucleated from surfaces that previously were buried inside the interphase centrosome. Finally, at the end of telophase, the mitotic centrosomes fold in such a way that the microtubule-nucleating surface remains on the outside of the organelle. Thus in each cell cycle the centrosome undergoes an apparent inside-out/outside-in reversal of its layered structure.
Resumo:
Polyglycylation, a posttranslational modification of tubulin, was discovered in the highly stable axonemal microtubules of Paramecium cilia where it involves the lateral linkage of up to 34 glycine units per tubulin subunit. The observation of this type of posttranslational modification mainly in axonemes raises the question as to its relationship with axonemal organization and with microtubule stability. This led us to investigate the glycylation status of cytoplasmic microtubules that correspond to the dynamic microtubules in Paramecium. Two anti-glycylated tubulin monoclonal antibodies (mAbs), TAP 952 and AXO 49, are shown here to exhibit different affinities toward mono- and polyglycylated synthetic tubulin peptides. Using immunoblotting and mass spectrometry, we show that cytoplasmic tubulin is glycylated. In contrast to the highly glycylated axonemal tubulin, which is recognized by the two mAbs, cytoplasmic tubulin reacts exclusively with TAP 952, and the α- and β- tubulin subunits are modified by only 1–5 and 2–9 glycine units, respectively. Our analyses suggest that most of the cytoplasmic tubulin contains side chain lengths of 1 or 2 glycine units distributed on several glycylation sites. The subcellular partition of distinct polyglycylated tubulin isoforms between cytoplasmic and axonemal compartments implies the existence of regulatory mechanisms for glycylation. By following axonemal tubulin immunoreactivity with anti-glycylated tubulin mAbs upon incubation with a Paramecium cellular extract, the presence of a deglycylation enzyme is revealed in the cytoplasm of this organism. These observations establish that polyglycylation is reversible and indicate that, in vivo, an equilibrium between glycylating and deglycylating enzymes might be responsible for the length of the oligoglycine side chains of tubulin.
Resumo:
The adenylyl and guanylyl cyclases catalyze the formation of 3′,5′-cyclic adenosine or guanosine monophosphate from the corresponding nucleoside 5′-triphosphate. The guanylyl cyclases, the mammalian adenylyl cyclases, and their microbial homologues function as pairs of homologous catalytic domains. The crystal structure of the rat type II adenylyl cyclase C2 catalytic domain was used to model by homology a mammalian adenylyl cyclase C1-C2 domain pair, a homodimeric adenylyl cyclase of Dictyostelium discoideum, a heterodimeric soluble guanylyl cyclase, and a homodimeric membrane guanylyl cyclase. Mg2+ATP or Mg2+GTP were docked into the active sites based on known stereochemical constraints on their conformation. The models are consistent with the activities of seven active-site mutants. Asp-310 and Glu-432 of type I adenylyl cyclase coordinate a Mg2+ ion. The D310S and D310A mutants have 10-fold reduced Vmax and altered [Mg2+] dependence. The NTP purine moieties bind in mostly hydrophobic pockets. Specificity is conferred by a Lys and an Asp in adenylyl cyclase, and a Glu, an Arg, and a Cys in guanylyl cyclase. The models predict that an Asp from one domain is a general base in the reaction, and that the transition state is stabilized by a conserved Asn-Arg pair on the other domain.