980 resultados para VIDEO-ASSISTED THORACIC SURGERY
Resumo:
Peer reviewed
Resumo:
Peer reviewed
Resumo:
Thoracic injuries in general are of great importance due to their high incidence and high mortality. Thoracic impalement injuries are rare but severe due to the combination of cause, effect and result. This study's primary objective is to report the case of a young man who was impaled by a two-wheeled horse carriage shaft while crashing his motorcycle in a rural zone. An EMT-B ferry was called at the crash scene and a conscious patient was found, sustaining a severe impalement injury to the left hemithorax, suspended over the floor by the axial skeleton with the carriage shaft coming across his left chest. As a secondary objective, a literature review of thoracic impalement injuries is performed. Cases of thoracic impalement injury require unique and individualized care based on injury severity and affected organs. Reported protocols for managing impalement injuries are entirely anecdotal, with no uniformity on impaled patient's approach and management. In penetrating trauma, it is essential not to remove the impaled object, so that possible vascular lesions remain buffered by the object, avoiding major bleeding and exsanguination haemorrhage. Severed impaled thoracic patients should be transferred to a specialist centre for trauma care, as these lesions typically require complex multidisciplinary treatment. High-energy thoracic impalement injuries are rare and hold a high mortality rate, due to the complexity of trauma and associated injuries such as thoracic wall and lung lesions. Modern medicine still seems limited in cases of such seriousness, not always with satisfactory results.
Resumo:
We have shown how the analysis of the angiotomography reconstruction through OsiriX program has assisted in endovascular perioperative programming. We presented its application in situations when an unexpected existence of metallic overlapping artifact (orthopedic osteosynthesis) compromised the adequate visualization of the arterial lesion during the procedure. Through manipulation upon OsiriX software, with assistance of preview under virtual fluoroscopy, it was possible to obtain the angles that would avoid this juxtaposition. These angles were reproduced in the C-arm, allowing visualization of the occluded segment, reducing the need for repeated image acquisitions and contrast overload, allowing the continuation of the procedure.
Resumo:
The purpose of this investigation was to evaluate three learning methods for teaching basic oral surgical skills Thirty predoctoral dental students without any surgical knowledge or previous surgical experience were divided Into three groups (n=10 each) according to instructional strategy Group 1, active learning Group 2, text reading only, and Group 3, text reading and video demonstration After instruction, the apprentices were allowed to practice incision dissection and suture maneuvers in a bench learning model During the students' performance, a structured practice evaluation test to account for correct or incorrect maneuvers was applied by trained observers Evaluation tests were repeated after thirty and sixty days Data from resulting scores between groups and periods were considered for statistical analysis (ANOVA and Tukey Kramer) with a significant level of a=0 05 Results showed that the active learning group presented the significantly best learning outcomes related to immediate assimilation of surgical procedures compared to other groups All groups results were similar after sixty days of the first practice Assessment tests were fundamental to evaluate teaching strategies and allowed theoretical and proficiency learning feedbacks Repetition and interactive practice promoted retention of knowledge on basic oral surgical skills
Resumo:
Purpose: To analyze in an experimental animal model the effect of 4 different levels of stents-graft oversizing on non-atherosclerotic aortas such as those found in young individuals who undergo stent-graft repair for traumatic aortic injuries. Methods: The diameter of the porcine thoracic aorta is similar to the aorta of young adults (18-20 mm), so 25 pigs were randomized into 5 groups: 1 control (without stent-graft) and 4 oversizing groups (A: 10%-19%, B: 20%-29%, C: 30%-39%, and D: >40%). Two types of biomechanical tests were performed on all aortas 4 weeks after endoprosthesis deployment. Results: The results of the detachment test, which analyzed the strength necessary to remove the stent-graft from the aorta, were similar in the 4 groups (A: 42 N, B: 41 N, C: 46 N, and D: 46 N). However, 2 aortas ruptured during the tests (groups C and D). The second test was performed in 3 aortic segments. Maximum shear strength, maximum stress, and maximum tension supported by the aortic wall had a negative and linear correlation with oversizing. There were significant differences in all 4 groups when compared with the control group. Strain, which reflects the elastic properties of the aortic wall, was very similar in all 4 groups, but a great difference was found when compared with the control group (p<0.0001). Conclusion: The study showed an important subacute change in the biomechanical properties of the aortic wall after implantation of an oversized endoprosthesis. This weakness of the aortic wall was confirmed by 2 ruptures during the detachment test. These results partially explain the interaction of stent-grafts with non-atherosclerotic thoracic aortas and may serve as a basis for further studies and the development of specific material to be used in vascular trauma and young patients. J Endovasc Ther. 2011; 18: 576-584
Resumo:
Objective. The objective of this study was to evaluate, using computed tomography, correlations between Hyrax appliance opening and post-SARPE skeletal changes. Study design. Fifteen patients underwent SARPE according to a specific protocol and were followed. Linear and angular measurements of the anterior, intermediate, and posterior portions of the maxilla were evaluated. The correlation between maxillary expansion and appliance opening was investigated. Results. Significant overall expansion was observed. In the anterior and intermediate portions of the maxilla, the increase in maxillary width was greater than that observed in the posterior portion. The degree of appliance opening was significantly greater than that of the skeletal expansion. Also, no linear correlation between appliance opening and regional maxillary expansion was established. Conclusion. The transverse expansion of the maxilla was less than uniform. The lack of linear correlation between appliance opening and skeletal expansion is attributable to multiple factors, including those related to the device, the surgical technique, and the craniofacial deformity itself. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 812-819)
Resumo:
Background/Aims: Safety of laparoscopic colectomy education methods remains unknown. This study aimed at comparing the outcomes of patients undergoing preceptored laparoscopic colectomy with patients operated on by the same preceptor. Methodology: A prospective analysis of 30 preceptored operations performed by nine surgeons (PD group) between 2006 and 2008 was conducted. Data of 30 operations matched for diagnosis and surgery type conducted by the same preceptor (P group) were evaluated. Results: Median age was 56.2 (26-80) and 55.2 (22-81) respectively in P and PD group (p=0.804). Eleven (36.7%) were male in P group, 16 (53.3%) in PD group (p=0.194). Preceptored operations were not significantly longer than operations performed by the preceptor (198 vs. 156 min) - p=0.072. Length of hospital stay did not differ [4 days (3-12) in P group, and 5 (3-15) in PD group, p=0.296]. Conversion occurred in 4 cases in PD and in 2 in P group (p=0.389). Morbidity was similar (23.3% in P and 26.7% in PD group). One patient from P and two from PD group needed re-operation. No deaths occurred. Conclusions: Laparoscopic colorectal surgery preceptorship programs in surgeon learner`s place are safe. Surgeons` introduction through basic and hands-on courses is required for skills acquisition needed to minimize adverse outcomes.
Resumo:
Introduction: Current advances in frame modeling and computer software allow stereotactic procedures to be performed with great accuracy and minimal risk of neural tissue or vascular injury. Case Report: In this report we associate a previously described minimally invasive stereotactic technique with state-of-the-art 3D computer guidance technology to successfully treat a 55-year-old patient with an arachnoidal cyst obstructing the aqueduct of Sylvius. We provide 1 detailed technical information and discuss how this technique deals with previous limitations for stereotactic manipulation of the aqueductal region. We further discuss current advances in neuroendoscopy for treating obstructive hydrocephalus and make comparisons with our proposed technique. Conclusion: We advocate that this technique is not only capable of treating this pathology but it also has the advantages to enable reestablishment of physiological CSF flow thus preventing future brainstem compression by cyst enlargement.
Resumo:
Background: Since its introduction, laparoscopic colorectal surgery has raised intense debate and controversies regarding its safety and effectiveness. Methods: This multicentric registry reports the experience of 28 Brazilian surgical teams specializing in laparoscopic colorectal surgery. Results: Between 1992 and 2007, 4744 patients (1994 men-42% and 2750 women-58%) were operated upon, with ages ranging from 13 to 94 years (average 57.5y). Benign diseases were diagnosed in 2356 patients (49.6%). Most diseases were located in 50.7% of the left and sigmoid colon, 28.2% in the rectum and anal canal. 8.0% in the right colon, and diffuse 7.0%. There were 181 (3.8%) intraoperative complications (from 0% to 14%). There were 261 (5.5%) reported conversions to laparotomy (from 0% to 16.5%), mainly during the early experience (n = 119 - 59.8%). Postoperative complications were registered in 683 (14.5%) patients (from 5.0% to 50%). Mortality occurred in 43 patients (0.8%). Surgeons who performed less than 50 cases reported similar rates of intraoperative (4.2% vs. 3.8%,- P = 0.7), postoperative complications (20.8% vs. 14.3%; P = 0.07), and mortality (1.0% vs. 0.9%; P = 0.5) but the conversion rate was higher (10.4% vs. 5.4%; P = 0.04). Two thousand three hundred and eighty-nine (50.4%) malignant tumors were operated upon, and histologic classification showed 2347 (98%) adenocarcinomas, 30 (0.6%) spinocelular carcinomas, and 12 (0.2%) other histologic types. Tumor recurrence rate was 16.3% among patients followed more than I year. After an average follow-Lip of 52 months, 19 (0.8%) parietal recurrences were reported, 18 of which were in port sites and I in a patient with disseminated disease. There was no incisional recurrence in the ports used to withdraw the pathologic specimen. Compared with other registries, there was a 75% increase in the number of groups pet-forming laparoscopic colorectal surgery and a decrease in conversions (from 10.5%. to 5.5%) and mortality (from 1.5% to 0.9%) rates. Conclusions: (1) The number of patients operated upon increased expressively during the last years; (2) operative indications for benign and malignant diseases were similar, and diverticular disease of the colon comprised 40% of the benign ones; (3) conversion and mortality rates decreased over time; (4) Surgeon`s experience did not influence the complication rates, but was associated with a lower conversion; and (5) oncologic outcome expressed by recurrence rates showed results similar to those reported in conventional surgery.
Resumo:
Background: Widespread use of prostate-specific antigen screening has resulted in younger and healthier men being diagnosed with prostate cancer. Their demands and expectations of surgical intervention are much higher and cannot be adequately addressed with the classic trifecta outcome measures. Objective: A new and more comprehensive method for reporting outcomes after radical prostatectomy, the pentafecta, is proposed. Design, setting, and participants: From January 2008 through September 2009, details of 1111 consecutive patients who underwent robot-assisted radical prostatectomy performed by a single surgeon were retrospectively analyzed. Of 626 potent men, 332 who underwent bilateral nerve sparing and who had 1 yr of follow-up were included in the study group. Measurements: In addition to the traditional trifecta outcomes, two perioperative variables were included in the pentafecta: no postoperative complications and negative surgical margins. Patients who attained the trifecta and concurrently the two additional outcomes were considered as having achieved the pentafecta. A logistic regression model was created to evaluate independent factors for achieving the pentafecta. Results and limitations: Continence, potency, biochemical recurrence-free survival, and trifecta rates at 12 mo were 96.4%, 89.8%, 96.4%, and 83.1%, respectively. With regard to the perioperative outcomes, 93.4% had no postoperative complication and 90.7% had negative surgical margins. The pentafecta rate at 12 mo was 70.8%. On multivariable analysis, patient age (p = 0.001) was confirmed as the only factor independently associated with the pentafecta. Conclusions: A more comprehensive approach for reporting prostate surgery outcomes, the pentafecta, is being proposed. We believe that pentafecta outcomes more accurately represent patients` expectations after minimally invasive surgery for prostate cancer. This approach may be beneficial and may be used when counseling patients with clinically localized disease. (C) 2011 European Association of Urology. Published by Elsevier B. V. All rights reserved.
Resumo:
In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.
Resumo:
Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.
Resumo:
Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.