976 resultados para Tomografia por Emissão de Pósitrons (PET)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A solar alternative system for water heating is presented. It work on a thermosiphon, consisting of one or two alternative collectors and a water storage tank also alternative, whose main purpose is to socialize the use of energy mainly to be used by people of low income. The collectors were built from the use of pets bottles, cans of beer and soft drinks and tubes of PVC, ½ " and the thermal reservoirs from a drum of polyethylene used for storage of water and garbage placed inside cylinder of fiber glass and EPS ground between the two surfaces. Such collectors are formed by three elements: pet bottles, cans and tubes absorbers. The heating units, which form the collector contains inside the cans that can be closed, in original form or in the form of plate. The collectors have an absorber grid formed by eight absorbers PVC tube, connected through connections at T of the same material and diameter. It will be presented data of the thermal parameters which demonstrate the efficiency of the heating system proposed. Relative aspects will be boarded also the susceptibility the thermal degradation and for UV for the PVC tubes. It will be demonstrated that this alternative heating system, which has as its main feature low cost, presents thermal, economic and materials viabilities

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many applications require that the plasma discharge is produced apart from the surface to be processed, thus preventing damage caused by bombardment and/or plasma radiation. In the post-discharge regime in various applications thermally sensitive materials can be used. In this work, active species produced by discharge and post-discharge hollow cathode were diagnosed by optical emission spectroscopy and mass spectrometry. The discharge was produced with the gases Ar and Ar - N2 gas flow ranging from 1 to 6 cm3/min and electric current between 150 to 600 mA. It was estimated that the ion density inside the hollow cathode, with 2 mm diameter ranged between 7.71 and 14.1 x 1015 cm-3. It was observed that the gas flow and the electric current changes the emission intensity of Ar and N2 species. The major ionic species detected by quadrupole mass spectrometry were Ar+ and N2+. The ratio of optical emission intensities of N2(1 +)/Ar(811 nm) was related to the partial pressure of N2 after the hollow cathode discharge at low pressure

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tinuvin P migration from Polyethyleneterephthalate (PET) bottles was investigated using several fatty-food simulants such as olive oil, soybean oil, n-heptane and iso-octane, at exposure conditions of 2-10 days at 40 degrees C (total immersion). The stability of several UV stabilizers (BHT, Cyasorb UV 5411, Tinuvin P, Tinuvin 326 and Tinuvin 327) in n-heptane and iso-octane was also studied. After 10 days at 40 degrees C, losses of 6% and 20% in iso-octane and n-heptane respectively, were verified for Tinuvin P. Other UV stabilizers at the same experimental conditions showed higher losses (up to 30% for Tinuvin 327). These results confirm that, when carrying out specific migration studies, the stability of the substance of interest should be established in the food simulant to avoid underestimating the real migration behaviour. In order to quantify UV stabilizer migration, n-heptane and iso-octane solutions were concentrated and directly analysed by SIM mode GC-MS. For olive and soybean oils, Tinuvin P was isolated using size-exclusion chromatography and quantified by SIM mode GC-MS. Iso-octane proved to be a move suitable fatty-food simulant than n-heptane for the migration study of Tinuvin P from PET. Higher levels of Tinuvin P migrated to olive and soybean oils rather than to n-heptane. These results suggest that the MERCOSUL recommended official methods for specific migration studies should be revised since the migration levels using n-heptane as a fatty-food simulant could be underestimated when compared to edible oils. Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work we study the processes of heating in the high stellar atmosphere, with base in an analysis of behavior of the cromospheric and coronal emission for a sample of single stars classified as giant in the literature. The evolutionary status of the stars of the sample was determined from HIPPARCOS satellite trigonometric parallax measurements and from the Toulouse Genéve code. In this study we show the form of behavior of the CaII emission flux in spectral lines H and K F(CaII) and the X-ray emission flux in function of the rotation, number of Rossby Ro and depth in mass of the convective envelope. In this analysis we show that while the cromospheric activity is dominated clearly by a physical process of heating associated with the rotation, like a magnetic field produced by dynamo effect, the coronal activity seems to be influenced for a mechanism independent of the rotation. We show also that the effective role of the depth in massa of the convective envelope on the stellar activity has an important effect in the responsible physical process for the behavior of the activity in the atmosphere of the stars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of post-consumer materials is directly related to reducing the cost of production and extraction of natural resources. Non-recyclable materials are randomly disposed in the environment. Brazil is one of the largest consumers of PET (polyethylene terephthalate) bottles. The purpose of this paper is to describe the opportunities and challenges of the logistics model for post-consumer PET bottle recycling in Brazil, while providing knowledge of its practices along the recycling chain. The results describe the need to educate those directly and indirectly involved in the process: to reduce consumption in order to reduce the amount of waste generated: to structure the post-consumer reverse chain and engage industrial sectors and government, through public policies, to support cleaner technologies along the PET bottle production chain. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prosthetic composite is a widely used biomaterial that satisfies the criteria for application as an organic implant without adverse reactions. Polyethylene therephthalate (PET) fiber-reinforced composites have been used because of the excellent cell adhesion, biodegradability and biocompatibility. The chemical inertness and low surface energy of PET in general are associated with inadequate bonds for polymer reinforcements. It is recognized that the high strength of composites, which results from the interaction between the constituents, is directly related to the interfacial condition or to the interphase. A radio frequency plasma reactor using oxygen was used to treat PET fibers for 5, 20, 30 and 100 s. The treatment conditions were 13.56 MHz, 50 W, 40 Pa and 3.33 x 10(-7) m(3)/s. A Rame-Hart goniometer was used to measure the contact angle and surface energy variation of fibers treated for different times. The experimental results showed contact angle values from 47degrees to 13degrees and surface energies from 6.4 x 10(-6) to 8.3 x 10(-6) J for the range of 5 to 100 s, respectively. These results were confirmed by the average ultimate tensile strength of the PET fiber/polymethylmethacrylate (PMMA) matrix composite tested in tensile mode and by scanning electron microscopy. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plasma treatments are frequently employed to modify surface properties of materials such as adhesivity, hydrophobicity, oleophobicity etc. Present work deals with surface modification of common commercial polymers such as polyethylene terephthalate (PET) and polyurethane (PU) by an air dielectric barrier discharge (DBD) at atmospheric pressure. The DBD treatment was performed in a plain reactor in wire-duct geometry (non-uniform field reactor), which was driven by a 60 Hz power supply. Material characterization was carried out by water contact angle measurements, atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). The plasma-induced modifications are associated with incorporation of polar oxygen and nitrogen containing groups on the polymer surface. The AFM analysis reveals that the plasma treatment roughens the material surface. Due to these structural and morphological changes the surface of DBD-treated polymers becomes more hydrophilic resulting in enhanced adhesion properties. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work examined the possibility of using mussel Mytella falcata as bioindicator sample to detect metal ions in several estuaries potiguares, since species substances that accumulate in their tissues due to its characteristics filter feeders have been used for environmental monitoring. The chemometrics by principal components analysis was used to reduce the size of the original data in order to establish a pattern of distribution of metal ion. Samples were collected at three different points in the estuaries Curimataú, Guaraíra-Papeba, Potengi, Galinhos-Guamaré and Piranhas-Assu having been marked with the location using GPS (Global Positioning System). The determination of humidity content and digestion of the samples were performed using methods described in the Compendium of analytical standards of the Institute Adofo Lutz (2005) and the determination of metal ions of the elements Al, Ba, Cd, Cr, Cu, Mn, Ni, Pb, Sn and Zn were performed by optical emission spectrometry with inductively coupled plasma as described by USEPA method 6010C. The results show that it is possible to use this molluscum Mytella falcata in the estuaries of Rio Grande do Norte for the determination of metal ions. The data were subjected to principal components analysis (PCA) which enabled us to verify the distribution pattern of the metal ions studied in several estuaries potiguares and group them according to the metal ions in common with and relate them to the activities in each region

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the non-invasive techniques employed in the prevention of caries highlights the sealing pits and fissures which is a conservative maneuver, in order to obliterate them to protect them from attack acid bacteria. Influenced by the studies of pre-heating composite resin, which has experienced great improvement in some of their physical properties, this study aimed to evaluate in vitro the superficial and internal marginal adaptation of different materials and sealants in pre-heating or not. A total of 40 extracted human third molars (n=10) that had their occlusal surfaces prepared to receive sealant. We tested two types of sealing materials: resin sealant (Fluoroshield) and low-viscosity resin (Permaflo), where 50% of previously received heated material and the other half received sealant material at room temperature. All samples were subjected to thermal cycling and pH, simulating a cariogenic oral environment, and later were analyzed appliance OCT (optical coherence tomography). The images obtained alterations were recorded and analyzed statistically. Change was considered as the emergence of bubbles, gaps and cracks in the sealant. Comparisons of the same material, assessing the fact that it is not sealed or preheated material, as well as comparisons between different materials subjected to the same temperature were carried out. The nonparametric Tukey test was used (p < 0,05). The results showed that there was statistically significant difference between both the materials analyzed, as between the situations in which the sealant material was submitted (preheated or not). On the issue of marginal adaptation and internal surface, seen through Optical coherence tomography, may suggest that there is a difference between the use of one type or another of the sealing material analyzed, with superiority attributed to resin Permaflo compared to sealant Fluroshield, telling is the same for the different techniques used

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation aimed to analyze the perception of students about (EPW Health) Education Program at Work for Health Training in the area of Health. It discusses the proposed theme from the perception of students graduating from the EPW- Health courses participants (dentistry, medicine, physiotherapy, nursing, nutrition, physical education) who have developed their school activities in family health units in the city of João Pessoa between 2009/2011.The program aims policies curricular changes as a potential route of contributions to training in healthcare. Attention is drawn to the new possibilities of working health training contextualized, ethically grounded, socially endorsed. It is pointed out in this process the need to adapt to the demands of professional profiles of SUS (Sistema Único de Saúde). This is an exploratory, descriptive study within a qualitative approach, conducted in the city of João Pessoa in the context of health care courses at the Federal University of Paraiba. The empirical material of this study was treated by the use of technical analysis "Categorical Content Theme" by Bardin. The results indicate prospects for promoting new practices and curricular changes, which highlights the EPW- Health, which has been presenting important experiences in teaching -community -service- with the inclusion of students in the municipal health network. We conclude that the path from collection to data analysis, corroborated with the literature to reaffirm the importance and urgency of change in educational processes with a view to greater proximity to the health needs and the SUS. The EPW- Health project is incipient and requires further investigation in terms of effective interdisciplinary and multidisciplinary character of its proposal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The visualization of three-dimensional(3D)images is increasigly being sed in the area of medicine, helping physicians diagnose desease. the advances achived in scaners esed for acquisition of these 3d exames, such as computerized tumography(CT) and Magnetic Resonance imaging (MRI), enable the generation of images with higher resolutions, thus, generating files with much larger sizes. Currently, the images of computationally expensive one, and demanding the use of a righ and computer for such task. The direct remote acess of these images thruogh the internet is not efficient also, since all images have to be trasferred to the user´s equipment before the 3D visualization process ca start. with these problems in mind, this work proposes and analyses a solution for the remote redering of 3D medical images, called Remote Rendering (RR3D). In RR3D, the whole hedering process is pefomed a server or a cluster of servers, with high computational power, and only the resulting image is tranferred to the client, still allowing the client to peform operations such as rotations, zoom, etc. the solution was developed using web services written in java and an architecture that uses the scientific visualization packcage paraview, the framework paraviewWeb and the PACS server DCM4CHEE.The solution was tested with two scenarios where the rendering process was performed by a sever with graphics hadwere (GPU) and by a server without GPUs. In the scenarios without GPUs, the soluction was executed in parallel with several number of cores (processing units)dedicated to it. In order to compare our solution to order medical visualization application, a third scenario was esed in the rendering process, was done locally. In all tree scenarios, the solution was tested for different network speeds. The solution solved satisfactorily the problem with the delay in the transfer of the DICOM files, while alowing the use of low and computers as client for visualizing the exams even, tablets and smart phones

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliação de condições dos equipamentos e dosimetria em setores de tomografia computadorizada utilizando protocolos de cabeça, abdome e coluna lombar em pacientes adultos (em três equipamentos distintos) e pediátricos com até um ano e meio de vida (em um dos equipamentos avaliados). MATERIAIS E MÉTODOS: Foram estimados o índice de dose em tomografia computadorizada e a dose média em cortes múltiplos, em exames com pacientes adultos, em três distintos equipamentos. Ainda foram estimadas as doses na superfície de entrada e as doses absorvidas em exame de cabeça para pacientes adultos e pediátricos em um dos equipamentos avaliados. RESULTADOS: Foram realizados testes de controle de qualidade, mecânicos, demonstrando que os equipamentos satisfazem as especificações de uso estabelecidas pelas normas vigentes. Os resultados da dosimetria mostraram que valores de dose média em cortes múltiplos excederam em até 109,0% os valores de níveis de referência, apresentando consideráveis variações entre os equipamentos avaliados neste estudo. As doses absorvidas obtidas com protocolos pediátricos são inferiores aos de pacientes adultos, apresentando redução de até 51,0% na tireoide. CONCLUSÃO: Neste estudo foram avaliadas as condições de operação de três equipamentos tomográficos, estabelecendo quais parâmetros devem ser trabalhados para a implantação de um programa de controle de qualidade nas instituições onde esta pesquisa foi desenvolvida.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: o presente estudo, de caráter prospectivo, objetivou avaliar a imagem da sutura palatina mediana em crianças submetidas à expansão rápida da maxila por meio de tomografia computadorizada, após a fase de contenção. METODOLOGIA: a amostra constou de 17 crianças de ambos os gêneros, na faixa etária compreendida entre 5 anos e 2 meses e 10 anos e 5 meses no início do tratamento, provenientes da Clínica de Ortodontia Interceptiva da Sociedade de Promoção Social do Fissurado Lábio-Palatal da Universidade de São Paulo (PROFIS-USP), Bauru/SP. Tomografias computadorizadas foram implementadas para avaliar o comportamento da sutura palatina mediana em diferentes momentos do tratamento. RESULTADOS E CONCLUSÕES: constatou-se que, após um período médio de 8 a 9 meses de contenção com o aparelho expansor, a sutura palatina mediana mostrou-se completamente ossificada, desde a região da espinha nasal anterior até a espinha nasal posterior. Tal informação esclarece o comportamento da sutura palatina mediana frente à expansão rápida da maxila e reitera o senso comum quanto ao caráter biológico do procedimento.