857 resultados para Tailored microstructure
Resumo:
In today’s highly competitive market, it is critical to provide customers services with a high level of configuration to answer their business needs. Knowing in advance the performance associated with a specific choreography of services (e.g., by taking into account the expected results of each component service) represents an important asset that allows businesses to provide a global service tailored to customers’ specific requests. This research work aims at advancing the state-of-the-art in this area by proposing an approach for service selection and ranking using services choreography, predicting the behavior of the services considering customers’ requirements and preferences, business process constraints and characteristics of the execution environment.
Resumo:
Atualmente, os sistemas de informação hospitalares têm de possibilitar uma utilização diferenciada pelos diferentes intervenientes, num cenário de constante adaptação e evolução. Para tal, é essencial a interoperabilidade entre os sistemas de informação do hospital e os diversos fornecedores de serviços, assim como dispositivos hospitalares. Apesar da necessidade de suportar uma heterogeneidade entre sistemas ser fundamental, o acesso/troca de informação deve ser feito de uma forma protocolada, segura e transparente. A infraestrutura de informação médica moderna consiste em muitos sistemas heterogéneos, com diversos mecanismos para controlar os dados subjacentes. Informações relativas a um único paciente podem estar dispersas por vários sistemas (ex: transferência de pacientes, readmissão, múltiplos tratamentos, etc.). Torna-se evidente a necessidade aceder a dados do paciente de forma consolidada a partir de diferentes locais. Desta forma, é fundamental utilizar uma arquitetura que promova a interoperabilidade entre sistemas. Para conseguir esta interoperabilidade, podem-se implementar camadas de “middleware” que façam a adaptação das trocas de informação entre os sistemas. Todavia, não resolvemos o problema subjacente, ou seja, a necessidade de utilização de um standard para garantir uma interacção fiável entre cliente/fornecedor. Para tal, é proposto uma solução que passa por um ESB dedicado para a área da saúde, denominada por HSB (Healthcare Service Bus). Entre as normas mais usuais nesta área devem-se salientar o HL7 e DICOM, esta última mais especificamente para dispositivos de imagem hospitalar, sendo a primeira utilizada para gestão e trocas de informação médica entre sistemas. O caso de estudo que serviu de base a esta dissertação é o de um hospital de média dimensão cujo sistema de informação começou por ser uma solução monolítica, de um só fornecedor. Com o passar dos anos, o fornecedor único desagregou-se em vários, independentes e concorrentes, dando lugar a um cenário extremamente preocupante em termos de manutenção e evolução futura do sistema de informação existente. Como resultado do trabalho efetuado, foi proposta uma arquitetura que permite a evolução do sistema atual de forma progressiva para um HSB puro.
Resumo:
Dissertação de Mestrado Apresentada ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria, sob orientação do Mestre Carlos Mendes.
Resumo:
RESUMO: Introdução: O treino de exercício assume uma importância fundamental nos programas de reabilitação respiratória, contudo permanece desconhecida qual a intensidade de treino efectiva na mudança dos resultados centrados no doente. Objectivos: Foram estudados os efeitos de duas intensidades de treino aeróbio na qualidade de vida relacionada com a saúde, no controlo de sintomas e na tolerância ao exercício, num programa de reabilitação respiratória para doentes com DPOC. Métodos: Trinta e quatro doentes com DPOC de estádios GOLD de ligeiro a muito grave, foram alocados aleatoriamente a intensidades de treino de exercício aeróbio de 60% ou 80% da intensidade máxima avaliada na prova de esforço num programa ambulatório de reabilitação respiratória de 20 sessões. Foram avaliados resultados centrados no doente pela aplicação do questionário respiratório de St.George, do índice de dispneia de Mahler, do questionário de actividades da vida diária do London Chest, da prova de 6 minutos, da prova de endurance a carga constante e da prova de esforço máxima incremental. Resultados: Apesar de existirem melhorias significativas em todos os resultados para ambos os grupos, a diferença média intergrupal por efeito da intensidade de treino aeróbio a 60% ou 80% da carga máxima em prova de esforço não foi significativa no questionário respiratório de St.George (p=0,306), no índice de dispneia de Mahler (p=0,378), no questionário de actividades da vida diária do London Chest (p=0,425), na prova de marcha de 6 minutos (p=0,917), na prova de endurance a carga constante (p=0,504) e na prova de esforço máxima incremental (p=0,117). Verificou-se ainda que a média das diferenças intergrupais na prova de endurance a carga constante e na prova de marcha de 6 minutos não apresentou qualquer associação com a idade dos doentes. Conclusões: O estudo permite concluir que não existem diferenças significativas nas alterações médias da qualidade de vida relacionada com a saúde, do controle de sintomas e da tolerância ao exercício em doentes com DPOC como efeito de duas intensidades de treino aeróbio. Os autores propõem para a prática clínica em reabilitação respiratória, a aplicação de intensidades de treino aeróbio individualmente adaptadas, de pelo menos 60% da carga máxima na prova de esforço inicial. -------------------------------ABSTRACT: Introduction: Exercise training is an important component of pulmonary rehabilitation, but it remains questionable as how training intensity changes patient-centered outcomes. Aims and objectives: The effects of two aerobic exercise training intensities in health-related quality of life, symptoms control and exercise tolerance in COPD patients were studied. Methods: Thirty-four COPD patients from mild to very severe GOLD stages were randomly assigned to a 60% or 80% aerobic exercise training intensity in a twenty-session outpatient pulmonary rehabilitation program. Patient-centered outcomes were assessed with St.George's respiratory questionnaire, Mahler dyspnoea index, London Chest activity of daily living, six minute walk test, constant work rate test and maximal incremental test. Results: Although there were significant improvements in all outcomes for both groups, there were no differences in mean change in St.George's respiratory questionnaire (p=0,306), Mahler dyspnoea index (p=0,378), London Chest activity of daily living (p=0,917), six-minute walk test (p=0,504), constant work rate test (p=0,504) and maximal incremental test (p=0,117), as an effect of aerobic exercise training intensity of 60% or 80%. Mean changes in constant work rate and six-minute walk test were not age-related. Conclusions: It is concluded that there are no differences in mean changes in health-related quality of life, symptoms control and exercise tolerance in COPD patients as an effect of two aerobic exercise training intensities. Therefore, the authors suggest that individually tailored exercise intensities above 60% should guide clinical practice in pulmonary rehabilitation.
Resumo:
Coarse Grained Reconfigurable Architectures (CGRAs) are emerging as enabling platforms to meet the high performance demanded by modern applications (e.g. 4G, CDMA, etc.). Recently proposed CGRAs offer time-multiplexing and dynamic applications parallelism to enhance device utilization and reduce energy consumption at the cost of additional memory (up to 50% area of the overall platform). To reduce the memory overheads, novel CGRAs employ either statistical compression, intermediate compact representation, or multicasting. Each compaction technique has different properties (i.e. compression ratio, decompression time and decompression energy) and is best suited for a particular class of applications. However, existing research only deals with these methods separately. Moreover, they only analyze the compaction ratio and do not evaluate the associated energy overheads. To tackle these issues, we propose a polymorphic compression architecture that interleaves these techniques in a unique platform. The proposed architecture allows each application to take advantage of a separate compression/decompression hierarchy (consisting of various types and implementations of hardware/software decoders) tailored to its needs. Simulation results, using different applications (FFT, Matrix multiplication, and WLAN), reveal that the choice of compression hierarchy has a significant impact on compression ratio (up to 52%), decompression energy (up to 4 orders of magnitude), and configuration time (from 33 n to 1.5 s) for the tested applications. Synthesis results reveal that introducing adaptivity incurs negligible additional overheads (1%) compared to the overall platform area.
Resumo:
This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.
Resumo:
Carnitine (CRT) is a biological metabolite found in urine that contributes in assessingseveral disease conditions, including cancer. Novel quick screening procedures for CRT are therefore fundamental. This work proposes a novel potentiometric device where molecularly imprinted polymers (MIPs) were used as ionophores. The host-tailored sites were imprinted on a polymeric network assembled by radical polymerization of methacrylic acid (MAA) and trimethylpropane trimethacrylate (TRIM). Non-imprinted polymers (NIPs) were produced as control by removing the template from the reaction media. The selective membrane was prepared by dispersing MIP or NIP particles in plasticizer and poly(vinyl chloride), PVC, and casting this mixture over a solid contact support made of graphite. The composition of the selective membrane was investigated with regard to kind/amount of sensory material (MIP or NIP), and the need for a lipophilic additive. Overall, MIP sensors with additive exhibited the best performance, with near-Nernstian response down to ~ 1 × 10− 4 mol L− 1, at pH 5, and a detection limitof ~ 8 × 10− 5 mol L− 1. Suitable selectivity was found for all membranes, assessed by the matched potential method against some of the most common species in urine (urea, sodium, creatinine, sulfate, fructose and hemoglobin). CRT selective membranes including MIP materials were applied successfully to the potentiometric determination of CRT in urine samples.
Resumo:
IEEE International Conference on Cyber Physical Systems, Networks and Applications (CPSNA'15), Hong Kong, China.
Resumo:
A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51–67 mV/decade and 0.46–3.9 μg/mL, respectively, in steady state conditions. Sensors were independent from the pH of test solutions within 2.0–5.5. Good selectivity was observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0 × 10−2 mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0 × 10−4 to 1.0 × 10−2 mol/L. Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples.
Resumo:
XXXIII Simpósio Brasileiro de Redes de Computadores e Sistemas Distribuídos (SBRC 2015). 15 to 19, May, 2015, III Workshop de Comunicação em Sistemas Embarcados Críticos. Vitória, Brasil.
Resumo:
6th Graduate Student Symposium on Molecular Imprinting
Resumo:
Demo in Workshop on ns-3 (WNS3 2015). 13 to 14, May, 2015. Castelldefels, Spain.
Resumo:
Poster in 12th European Conference on Wireless Sensor Networks (EWSN 2015). 9 to 11, Feb, 2015, pp 24-25. Porto, Portugal.
Resumo:
XXXIII Simpósio Brasileiro de Redes de Computadores e Sistemas Distribuídos (SBRC 2015), III Workshop de Comunicação em Sistemas Embarcados Críticos. Vitória, Brasil.
Resumo:
Notre étude présente une réflexion à propos de espaces musicaux composables. Cette réflexion inclue l’usage intentionnel des qualités sonores perçues dans la construction de sons et donc dans la composition musicale. Nos recherches se trouvent à l’intersection entre le son, comme phénomène physique qui se propage dans un espace, les sensations spatiales qui peuvent être engendrées par la perception auditive de ses certaines caractéristiques, et la pratique de la composition musicale d’espaces de sons dans les œuvres. Nous développons l’idée d’une entité sonore composable dès sa microstructure. Nous la concevons par analogie avec les objets du monde visible et palpable. Nous utilisons les idées de volume, forme et matière ainsi que celles de position et de mouvement des objets matériels, comme métaphore pour concevoir des entités sonores complexes et des espaces musicaux composés dans lesquels elles seront intégrées. Cette entité sonore constituée d’un ensemble d’éléments disparates, permet le développement de réseaux opératoires manipulables dans, la pratique, par les compositeurs.