982 resultados para Standard Work


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work measures and tries to compare the Antioxidant Capacity (AC) of 50 commercial beverages of different kinds: 6 wines, 12 beers, 18 soft drinks and 14 flavoured waters. Because there is no reference procedure established for this purpose, three different optical methods were used to analyse these samples: Total Radical trapping Antioxidant Parameter (TRAP), Trolox Equivalent Antioxidant Capacity (TEAC) and Ferric ion Reducing Antioxidant Parameter (FRAP). These methods differ on the chemical background and nature of redox system. The TRAP method involves the transfer of hydrogen atoms while TEAC and FRAP involves electron transfer reactions. The AC was also assessed against three antioxidants of reference, Ascorbic acid (AA), Gallic acid (GA) and 6-hydroxy-2,5,7,8-tetramethyl- 2-carboxylic acid (Trolox). The results obtained were analyzed statistically. Anova one-way tests were applied to all results and suggested that methods and standards exhibited significant statistical differences. The possible effect of sample features in the AC, such as gas, flavours, food colouring, sweeteners, acidity regulators, preservatives, stabilizers, vitamins, juice percentage, alcohol percentage, antioxidants and the colour was also investigated. The AC levels seemed to change with brand, kind of antioxidants added, and kind of flavour, depending on the sample. In general, higher ACs were obtained for FRAP as method, and beer for kind of sample, and the standard expressing the smaller AC values was GA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Thesis submitted for the co-tutelle degree of Doctor in Physics at Universidade Nova de Lisboa and Université Pierre et Marie Curie

Relevância:

20.00% 20.00%

Publicador:

Resumo:

13th IEEE/IFIP International Conference on Embedded and Ubiquitous Computing (EUC 2015). 21 to 23, Oct, 2015, Session W1-A: Multiprocessing and Multicore Architectures. Porto, Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Teaching robotics to students at the beginning of their studies has become a huge challenge. Simulation environments can be an effective solution to that challenge where students can interact with simulated robots and have the first contact with robotic constraints. From our previous experience with simulation environments it was possible to observe that students with lower background knowledge in robotics where able to deal with a limited number of constraints, implement a simulated robotic platform and study several sensors. The question is: after this first phase what should be the best approach? Should the student start developing their own hardware? Hardware development is a very important part of an engineer's education but it can also be a difficult phase that could lead to discouragement and loss of motivation in some students. Considering the previous constraints and first year engineering students’ high abandonment rate it is important to develop teaching strategies to deal with this problem in a feasible way. The solution that we propose is the integration of a low-cost standard robotic platform WowWee Rovio as an intermediate solution between the simulation phase and the stage where the students can develop their own robots. This approach will allow the students to keep working in robotic areas such as: cooperative behaviour, perception, navigation and data fusion. The propose approach proved to be a motivation step not only for the students but also for the teachers. Students and teachers were able to reach an agreement between the level of demand imposed by the teachers and satisfaction/motivation of the students.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paper/Poster presented in Work in Progress Session, 28th GI/ITG International Conference on Architecture of Computing Systems (ARCS 2015). 24 to 26, Mar, 2015. Porto, Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poster presented in Work in Progress Session, 28th GI/ITG International Conference on Architecture of Computing Systems (ARCS 2015). 24 to 26, Mar, 2015. Porto, Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a low cost RTK-GPS system for localization of unmanned surface vehicles. The system is based on the use of standard low cost L1 band receivers and in the RTKlib open source software library. Mission scenarios with multiple robotic vehicles are addressed as the ones envisioned in the ICARUS search and rescue case where the possibility of having a moving RTK base on a large USV and multiple smaller vehicles acting as rovers in a local communication network allows for local relative localization with high quality. The approach is validated in operational conditions with results presented for moving base scenario. The system was implemented in the SWIFT USV with the ROAZ autonomous surface vehicle acting as a moving base. This setup allows for the performing of a missions in a wider range of environments and applications such as precise 3D environment modeling in contained areas and multiple robot operations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente relatório diz respeito ao trabalho desenvolvido ao longo de seis meses em ambiente de estágio curricular na empresa O FELIZ – Metalomecânica, S.A.. O objetivo principal deste trabalho foi o conhecimento resultante de uma experiência num ambiente industrial no sector das construções metálicas. Pela especificidade do setor, foi desenvolvido um estudo no âmbito da conceção e execução (na componente de fabrico) de estruturas. O relatório que resulta deste trabalho de estágio tem como referência um caso de estudo de uma estrutura metálica. O caso de estudo realizado é referente a um pavilhão industrial standard, e possui dimensões em planta de 60 x 25 metros e cércea total de 9,0 metros, para o qual foi efetuado um breve dimensionamento de toda a estrutura metálica principal. O edifício será constituído por um sistema de pórtico simples formado por perfis laminados a quente normalizados de secção IPE e de aço de classe S275. Posteriormente, e com recurso a software apropriado de detalhamento de estruturas metálicas, foi desenvolvido um modelo 3D de toda a estrutura metálica do edifício. Neste modelo estão presentes todos os elementos constituintes da estrutura, bem como algumas das características físicas e mecânicas de cada peça elementar. Por fim, e com base no modelo anterior foram gerados e editados todos os desenhos 2D para o fabrico da estrutura, incluindo os desenhos de montagem da estrutura.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com as dificuldades económicas que se fazem sentir nos últimos anos, tanto em Portugal como no resto do mundo, em qualquer área de negócio, a qualidade tornou-se um dos fatores de sucesso. Com um mercado cada vez com mais concorrência, os clientes procuram frequentemente a melhor qualidade do produto ou do serviço da empresa. Para isso as empresas cada vez mais apostam em fornecer um produto de qualidade através de um sistema da qualidade bem delineado, bem gerido e certificado. O presente trabalho que foi desenvolvido nesta dissertação de Mestrado consistiu na conceção e acompanhamento da Implementação do Sistema de Gestão da Qualidade (SGQ) segundo a norma NP EN ISO 9001:2008 realizada numa indústria de componentes de calçado, designada NEWCOMP, Componentes para Calçado, LDA. (NCP), localizada em S. João da Madeira. Será uma ferramenta bastante útil e estratégica para a empresa a certificação, com inúmeras vantagens e benefícios para a sua imagem. As principais razões que levaram a empresa a interessar-se pela certificação do SGQ foi, principalmente, a melhoria da qualidade dos seus produtos, satisfação dos clientes e alcançar novos mercados. A documentação elaborada do SGQ inclui a política e objetivos da qualidade, esquemas dos principais processos, manual de funções entre outros documentos considerados necessários, para utilização de todas as partes envolvidas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta dissertação descreve o levantamento da gestão de uma unidade fabril no âmbito do engarrafamento de águas, para a implementação de um Sistema de Gestão Ambiental (SGA) recorrendo á Norma NP EN ISO 14001:2012 tendo como objetivo proporcionar a melhoria contínua dos processos implementados na empresa bem como todos os benefícios que este referencial pressupõe. Foi realizada, numa primeira fase, uma auditoria diagnóstico com uma visita á fabrica no âmbito da implementação da ISO 14001, e posteriormente realizado todo o trabalho de aplicação ao referencial. Este trabalho consistiu a abordagem a todos os requisitos da norma ISO 14001 com principal foco na fase de Planeamento de um SGA, procurando-se responder essencialmente ao requisito 4.3 da referida norma. Procedeu-se á identificação das atividades da empresa (entradas e saídas), dos aspetos ambientais associados (respetiva significância) e levantamento dos requisitos legais aplicáveis (obrigações). Os restantes requisitos foram abordados e fez-se uma sugestão para o seu cumprimento, para além de que muitos já se encontram em cumprimento por compatibilidade com a norma ISO 9001 da qual a empresa já se encontra certificada. Esta dissertação pretende discutir e apresentar propostas para a implementação do SGA, possíveis vantagens daí decorrentes e as barreiras a ultrapassar (aspetos ambientais significativos) de maneiras a por em prática os requisitos do referencial normativo que venha a ser adotado. Foi realizada uma revisão bibliográfica destas temáticas e, ainda que estas medidas propostas não tenham sido implementadas, assim que implementadas esperam-se ganhos na economia de recursos como também outros benefícios descritos ao longo da dissertação que permita, com implementação do SGA não só enquanto estratégia, ser inovadora e competitiva.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To improve surgical safety, and to reduce the mortality and surgical complications incidence, the World Health Organization (WHO) developed the Surgical Safety Checklist (SSC). The SSC is a support of information that aids health professionals to reduce the number of complications, induction of anaesthesia, period before skin incision and period before leaving the operating room (OR). The SSC was tested in several countries of the world and their results shown that after introduction of the SSC the incidence of patient complication lowered from 11.0% to 7.0% (P<0.001), the rate of death declined from 1.5% to 0.8% (P = 0.003) and the nurses recognized that patients identity was more often con rmed (81.6% to 94.2%, P<0.01) in many institutions. Recently the SSC was also implemented in Portuguese hospitals, which led us to its study in the real clinical environment. An observational study was performed: several health professionals were observed and interviewed, to understand the functioning of the SSC in an OR, during the clinical routine. The objective of this study was to understand the current use of the SSC, and how it may be improved in terms of usability, taking advantage of the technological advancements such as mobile applications. During two days were observed 14 surgeries, only 2 surgeries met the requirements for the three phases of the SSC, as de ned by the WHO. Of the remaining 12 observed surgeries, 9 surgeries completed the last phase at the correct time. It was also observed that only in 2 surgeries all the phases of the SSC were read aloud to the team and that, in 7 surgeries, several items were read aloud and answered but no one was checking the SSC, only after the end of the phase. The observational study results disclose that several health professionals do not meet with rules of the WHO manual. This study demonstrates that it is urgent to change the mindset of health professionals, and that di erent features in the SSC may be useful to make it more easy to use. With the results of the observational study, a SSC application proposal was developed with new functionalities to improve and aid the health professional in its use. In this application the user can chose between a SSC already created to a speci c surgery or to create a new SSC, adding and adapting some questions from the WHO standard. To create a new SSC, the application is connected to an online questionnaire builder (JotForm). The choice for this online questionnaire builder went through three essential characteristics: number of types of questions, mainly checkbox, radio button and text; the possibility of to create sections inside sections and the API. In addition, in this proposal the improvements are focused in forcing the user to focus in the work ow of the SSC and to save the input timestamps and any actions made by them. Therefore, the following features was implemented to achieve that goal: display one item of the SSC at a time; display the stage where the SSC is; do not allow going back to the previous step; do not allow going forward to the next item if the current is not lled; do not allow going forward to the next item if the time it took to ll the item was too short and log any action made by the user.