919 resultados para LD pump


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study demonstrates the possibility of using an absorption chiller to produce chilled water for air conditioning, and at the same time recover the rejected heat producing domestic hot water. The absorption chiller considered for this application has been sized to suit a standard household and uses a solution of ammonia and water running on hot water at a temperature ranging from 80 - 120°C produced by thermal solar panels. The system consists of five main components: generator, rectifier, condenser, evaporator and absorber, and is divided in two sections at two different pressures. The section at higher pressure includes the generator, rectifier and condenser whereas the section at lower pressure includes the evaporator and the absorber. Heat in this type of system is usually rejected to the environment from the condenser, rectifier and absorber through a cooling tower or air cooler exchanger. In this paper we describe how to recover this heat to create domestic hot water by providing a quantitative evaluation of the amount of energy recovered by the proposed system, if used in the Australian region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 4-cylinder Ford 2701C test engine was used in this study to explore the impact of ethanol fumigation on gaseous and particle emission concentrations. The fumigation technique delivered vaporised ethanol into the intake manifold of the engine, using an injector, a pump and pressure regulator, a heat exchanger for vaporising ethanol and a separate fuel tank and lines. Gaseous (Nitric oxide (NO), Carbon monoxide (CO) and hydrocarbons (HC)) and particulate emissions (particle mass (PM2.5) and particle number) testing was conducted at intermediate speed (1700 rpm) using 4 load settings with ethanol substitution percentages ranging from 10-40 % (by energy). With ethanol fumigation, NO and PM2.5 emissions were reduced, whereas CO and HC emissions increased considerably and particle number emissions increased at most test settings. It was found that ethanol fumigation reduced the excess air factor for the engine and this led to increased emissions of CO and HC, but decreased emissions of NO. PM2.5 emissions were reduced with ethanol fumigation, as ethanol has a very low “sooting” tendency. This is due to the higher hydrogen-to-carbon ratio of this fuel, and also because ethanol does not contain aromatics, both of which are known soot precursors. The use of a diesel oxidation catalyst (as an after-treatment device) is recommended to achieve a reduction in the four pollutants that are currently regulated for compression ignition engines. The increase in particle number emissions with ethanol fumigation was due to the formation of volatile (organic) particles; consequently, using a diesel oxidation catalyst will also assist in reducing particle number emissions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A physiological control system was developed for a rotary left ventricular assist device (LVAD) in which the target pump flow rate (LVADQ) was set as a function of left atrial pressure (LAP), mimicking the Frank-Starling mechanism. The control strategy was implemented using linear PID control and was evaluated in a pulsatile mock circulation loop using a prototyped centrifugal pump by varying pulmonary vascular resistance to alter venous return. The control strategy automatically varied pump speed (2460 to 1740 to 2700 RPM) in response to a decrease and subsequent increase in venous return. In contrast, a fixed-speed pump caused a simulated ventricular suction event during low venous return and higher ventricular volumes during high venous return. The preload sensitivity was increased from 0.011 L/min/mmHg in fixed speed mode to 0.47L/min/mmHg, a value similar to that of the native healthy heart. The sensitivity varied automatically to maintain the LAP and LVADQ within a predefined zone. This control strategy requires the implantation of a pressure sensor in the left atrium and a flow sensor around the outflow cannula of the LVAD. However, appropriate pressure sensor technology is not yet commercially available and so an alternative measure of preload such as pulsatility of pump signals should be investigated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

16.1. Agents to control acidity 16.1.1 Antacids 16.1.2 Proton pump inhibitors and antibiotics for Helicobacter pylori 16.1.3 Histamine H2 receptor antagonists 16.1.4 Misoprostol 16.1.5 Sucralfate 16.2. Prokinetics and emetics 16.2.1 Introduction to prokinetics 16.2.2 Prokinetic agents 16.2.3 Emesis with cytotoxic drugs and drugs for 16.2.4 Motion sickness and drugs for 16.2.5 Drugs for post-operative emesis 16.3. Agents used for diarrhea, constipation, irritable bowel syndrome 16.3.1 Treatment for diarrhea 16.3.2 Treatment for constipation 16.3.3 Treatment for opioid-induced constipation 16.4. Drugs for inflammatory bowel disease 16.4.1 Mesalazine 16.4.2 Glucocorticoids 16.4.3 Infliximab

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To measure the thickness at which primary schoolchildren apply sunscreen on school day mornings and to compare it with the thickness (2.00 mg/cm(2)) at which sunscreen is tested during product development, as well as to investigate how application thickness was influenced by age of the child (school grades 1-7) and by dispenser type (500-mL pump, 125-mL squeeze bottle, or 50-mL roll-on). DESIGN: A crossover quasiexperimental study design comparing 3 sunscreen dispenser types. SETTING: Children aged 5 to 12 years from public primary schools (grades 1-7) in Queensland, Australia. PARTICIPANTS: Children (n=87) and their parents randomly recruited from the enrollment lists of 7 primary schools. Each child provided up to 3 observations (n=258). INTERVENTION: Children applied sunscreen during 3 consecutive school weeks (Monday through Friday) for the first application of the day using a different dispenser each week. MAIN OUTCOME MEASURE: Thickness of sunscreen application (in milligrams per square centimeter). The dispensers were weighed before and after use to calculate the weight of sunscreen applied. This was divided by the coverage area of application (in square centimeters), which was calculated by multiplying the children's body surface area by the percentage of the body covered with sunscreen. RESULTS: Children applied their sunscreen at a median thickness of 0.48 mg/cm(2). Children applied significantly more sunscreen when using the pump (0.75 mg/cm(2)) and the squeeze bottle (0.57 mg/cm(2)) compared with the roll-on (0.22 mg/cm(2)) (P<.001 for both). CONCLUSIONS: Regardless of age, primary schoolchildren apply sunscreen at substantially less than 1.00 mg/cm(2), similar to what has been observed among adults. Some sunscreen dispensers seem to facilitate thicker application than others.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to assess the feasibility of a home-based exercise program and examine the effects on the healing rates of venous leg ulcers. A 12 –week randomised controlled trial was conducted investigating the effects of an exercise intervention compared to a usual care group. Participants in both groups (n = 13) had active venous ulceration and were treated in a metropolitan hospital outpatients clinic in Australia. Data were collected on recruitment from medical records, clinical assessment and questionnaires. Follow-up data on progress in healing and treatments were collected fortnightly for 12 weeks. Calf muscle pump function data were collected at baseline and 12 weeks from recruitment. Range of ankle motion data were collected at baseline, 6 and 12 weeks from recruitment. This pilot study indicated that the intervention was feasible. Clinical significance was observed in the intervention group with a 32% greater decrease in ulcer size (p=0.34) than the control group, and a 10% (p=0.74) improvement in the number of participants healed in the intervention group compared to the control group. Significant differences between groups over time were observed in calf muscle pump function parameters; (ejection fraction [p = 0.05]; residual volume fraction [p = 0.04]) and range of ankle motion (p = 0.01). This pilot study is one of the first studies to examine and measure clinical healing rates for participants involved in a home-based progressive resistance exercise program. Further research is warranted with a larger multi-site study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ability to forecast machinery health is vital to reducing maintenance costs, operation downtime and safety hazards. Recent advances in condition monitoring technologies have given rise to a number of prognostic models which attempt to forecast machinery health based on condition data such as vibration measurements. This paper demonstrates how the population characteristics and condition monitoring data (both complete and suspended) of historical items can be integrated for training an intelligent agent to predict asset health multiple steps ahead. The model consists of a feed-forward neural network whose training targets are asset survival probabilities estimated using a variation of the Kaplan–Meier estimator and a degradation-based failure probability density function estimator. The trained network is capable of estimating the future survival probabilities when a series of asset condition readings are inputted. The output survival probabilities collectively form an estimated survival curve. Pump data from a pulp and paper mill were used for model validation and comparison. The results indicate that the proposed model can predict more accurately as well as further ahead than similar models which neglect population characteristics and suspended data. This work presents a compelling concept for longer-range fault prognosis utilising available information more fully and accurately.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Extra corporeal membrane oxygenation (ECMO) is a complex rescue therapy used to provide cardiac and/or respiratory support for critically ill patients who have failed maximal conventional medical management. ECMO is based on a modified cardiopulmonary bypass (CPB) circuit, and can provide cardiopulmonary support for up-to several months. It can be used in a veno venous configuration for isolated respiratory failure, (VV-ECMO), or in a veno arterial configuration (VA-ECMO) where support is necessary for cardiac +/- respiratory failure. The ECMO circuit consists of five main components: large bore cannulae (access cannulae) for drainage of the venous system, and return cannulae to either the venous (in VV-ECMO) or arterial (in VA ECMO) system. An oxygenator, with a vast surface area of hollow filaments, allows addition of oxygen and removal of carbon dioxide; a centrifugal blood pump allows propulsion of blood through the circuit at upto 10 L/minute; a control module and a thermoregulatory unit, which allows for exact temperature control of the extra corporeal blood. Methods: The first successful use of ECMO for ARDS in adults occurred in 1972, and its use has become more commonplace over the last 30 years, supported by the improvement in design and biocompatibility of the equipment, which has reduced the morbidity associated with this modality. Whilst the use of ECMO in neonatal population has been supported by numerous studies, the evidence upon which ECMO was integrated into adult practice was substantially less robust. Results: Recent data, including the CESAR study (Conventional Ventilatory Support versus Extra corporeal membrane oxygenation for Severe Respiratory failure) has added a degree of evidence to the role of ECMO in such a patient population. The CESAR study analysed 180 patients, and confirmed that ECMO was associated with an improved rate of survival. More recently, ECMO has been utilized in numerous situations within the critical care area, including support in high-risk percutaneous interventions in cardiac catheter lab; the operating room, emergency department, as well in specialized inter-hospital retrieval services. The increased understanding of the risk:benefit profile of ECMO, along with a reduction in morbidity associated with its use will doubtless lead to a substantial rise in the utilisation of this modality. As with all extra-corporeal circuits, ECMO opposes the basic premises of the mammalian inflammation and coagulation cascade where blood comes into foreign circulation, both these cascades are activated. Anti-coagulation is readily dealt with through use of agents such as heparin, but the inflammatory excess, whilst less macroscopically obvious, continues un-abated. Platelet consumption and neutrophil activation occur rapidly, and the clinician is faced with balancing the need of anticoagulation for the circuit, against haemostasis in an acutely bleeding patient. Alterations in pharmacokinetics may result in inadequate levels of disease modifying therapeutics, such as antibiotics, hence paradoxically delaying recovery from conditions such as pneumonia. Key elements of nutrition and the innate immune system maysimilarly be affected. Summary: This presentation will discuss the basic features of ECMO to the nonspecialist, and review the clinical conundrum faced by the team treating these most complex cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Historical information can be used, in addition to pedigree, traits and genotypes, to map quantitative trait locus (QTL) in general populations via maximum likelihood estimation of variance components. This analysis is known as linkage disequilibrium (LD) and linkage mapping, because it exploits both linkage in families and LD at the population level. The search for QTL in the wild population of Soay sheep on St. Kilda is a proof of principle. We analysed the data from a previous study and confirmed some of the QTLs reported. The most striking result was the confirmation of a QTL affecting birth weight that had been reported using association tests but not when using linkage-based analyses. Copyright © Cambridge University Press 2010.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel multiple regression method (RM) is developed to predict identity-by-descent probabilities at a locus L (IBDL), among individuals without pedigree, given information on surrounding markers and population history. These IBDL probabilities are a function of the increase in linkage disequilibrium (LD) generated by drift in a homogeneous population over generations. Three parameters are sufficient to describe population history: effective population size (Ne), number of generations since foundation (T), and marker allele frequencies among founders (p). IBD L are used in a simulation study to map a quantitative trait locus (QTL) via variance component estimation. RM is compared to a coalescent method (CM) in terms of power and robustness of QTL detection. Differences between RM and CM are small but significant. For example, RM is more powerful than CM in dioecious populations, but not in monoecious populations. Moreover, RM is more robust than CM when marker phases are unknown or when there is complete LD among founders or Ne is wrong, and less robust when p is wrong. CM utilises all marker haplotype information, whereas RM utilises information contained in each individual marker and all possible marker pairs but not in higher order interactions. RM consists of a family of models encompassing four different population structures, and two ways of using marker information, which contrasts with the single model that must cater for all possible evolutionary scenarios in CM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Water and ammonium retention by sandy soils may be low and result in leaching of applied fertiliser. To increase water and nutrient retention, zeolite is sometimes applied as a soil ameliorant for high value land uses including turf and horticulture. We have used a new modified kaolin material (MesoLite) as a soil amendment to test the efficiency of NH4+ retention and compared the results with natural zeolite. MesoLite is made by caustic reaction of kaolin at temperature between 80-95°C; although it has a moderate surface area, its cation exchange capacity is very high;(SA=13m2/g,CEC=500meq/100g). A 13cm tall sand column filled with ~450g of sandy soil homogeneously mixed with 1, 2, 4, and 8g of MesoLite or natural zeolite per 1kg of soil was prepared. After saturation with local bore water, concentrated ammonium sulfate solution was injected at the base. Then, bore water was passed from bottom to top through the column at amounts up to 6 pore volumes and at a constant flow rate of 10ml/min using a peristaltic pump. Concentrations of leached NH4+ were determined using an AutoAnalyser. The concentration of NH4+ leached from the column with 0.4% MesoLite was greatly (90%) reduced relative to unamended soil. Under these conditions NH4+ retention by the soil-MesoLite mixture was 11.5 times more efficient than the equivalent soil-natural zeolite mixture. Glasshouse experiments conducted in a separate study show that NH4+ adsorbed by MesoLite is available to plants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In condition-based maintenance (CBM), effective diagnostic and prognostic tools are essential for maintenance engineers to identify imminent fault and predict the remaining useful life before the components finally fail. This enables remedial actions to be taken in advance and reschedule of production if necessary. All machine components are subjected to degradation processes in real environments and they have certain failure characteristics which can be related to the operating conditions. This paper describes a technique for accurate assessment of the remnant life of bearings based on health state probability estimation and historical knowledge embedded in the closed loop diagnostics and prognostics system. The technique uses the Support Vector Machine (SVM) classifier as a tool for estimating health state probability of machine degradation process to provide long term prediction. To validate the feasibility of the proposed model, real life fault historical data from bearings of High Pressure-Liquefied Natural Gas (HP-LNG) pumps were analysed and used to obtain the optimal prediction of remaining useful life (RUL). The results obtained were very encouraging and showed that the proposed prognosis system based on health state probability estimation has the potential to be used as an estimation tool for remnant life prediction in industrial machinery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this research fluidization behavior of cubical Bovine intestine samples was studied. Bovine intestine samples were heat pump dried at atmospheric pressure and at emperatures below and above the material freezing points. Experiments were conducted to study fluidization characteristics and drying kinetics at different drying conditions. Bovine particles were characterized according to Geldart classification and minimum fluidization velocity was calculated using Ergun Equation and generalized equation for all drying conditions at the beginning of the trials and end of the trials. Walli’s model was used to categorize stability of the fluidization at the beginning and end of the drying for each trial. Walli’s values determined were positive at the beginning and end of all trials indicating stable fluidisation at the beginning and end for each drying condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bovine intestine samples were heat pump fluidized bed dried at atmospheric pressure and at temperatures below and above the material freezing points equipped with a continuous monitoring system. The investigation of the drying characteristics has been conducted in the temperature range -10~25oC and the airflow in the range 1.5~2.5 m/s. Some experiments were conducted as a single temperature drying experiments and others as two stage drying experiments employing two temperatures. An Arrhenius-type equation was used to interpret the influence of the drying air parameters on the effective diffusivity, calculated with the method of slopes in terms of energy activation, and this was found to be sensitivity of the temperature. The effective diffusion coefficient of moisture transfer was determined by Fickian method using uni-dimensional moisture movement in both moisture, removal by evaporation and combined sublimation and evaporation. Correlations expressing the effective moisture diffusivity and drying temperature are reported.