984 resultados para Instrumented buoy


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors conducted a retrospective study on 24 consecutive adolescent scoliosis patients, 11 of whom were instrumented with hooks and 13 with hooks and screws (hybrid technique). The mean preoperative Cobb angle was 62.2 degrees (range: 48 degrees-96 degrees). The mean correction of the primary curve was 56.6% at followup after +/- 1.18 years ; there was no statistically significant difference between groups. Special attention was given to the postoperative quality of life (QOL) by means of the following scores: COMI patient self-assessment, SF-36, ODI, and VAS. Again, there was no statistical difference between groups but, interestingly, there was no correlation between QOL and degree of correction, after a follow-up period of +/- 2.1 years. Nevertheless, on the COMI patient self-assessment, there was a high level of satisfaction with treatment. Further studies should concentrate on how to achieve a high QOL, and abandon the best possible correction as a primary endpoint of success.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT : INTRODUCTION : V2-receptor (V2R) stimulation potentially aggravates sepsis-induced vasodilation, fluid accumulation and microvascular thrombosis. Therefore, the present study was performed to determine the effects of a first-line therapy with the selective V2R-antagonist (Propionyl1-D-Tyr(Et)2-Val4-Abu6-Arg8,9)-Vasopressin on cardiopulmonary hemodynamics and organ function vs. the mixed V1aR/V2R-agonist arginine vasopressin (AVP) or placebo in an established ovine model of septic shock. METHODS : After the onset of septic shock, chronically instrumented sheep were randomly assigned to receive first-line treatment with the selective V2R-antagonist (1 g/kg per hour), AVP (0.05 g/kg per hour), or normal saline (placebo, each n = 7). In all groups, open-label norepinephrine was additionally titrated up to 1 g/kg per minute to maintain mean arterial pressure at 70 ± 5 mmHg, if necessary. RESULTS : Compared to AVP- and placebo-treated animals, the selective V2R-antagonist stabilized cardiopulmonary hemodynamics (mean arterial and pulmonary artery pressure, cardiac index) as effectively and increased intravascular volume as suggested by higher cardiac filling pressures. Furthermore, left ventricular stroke work index was higher in the V2R-antagonist group than in the AVP group. Notably, metabolic (pH, base excess, lactate concentrations), liver (transaminases, bilirubin) and renal (creatinine and blood urea nitrogen plasma levels, urinary output, creatinine clearance) dysfunctions were attenuated by the V2R-antagonist when compared with AVP and placebo. The onset of septic shock was associated with an increase in AVP plasma levels as compared to baseline in all groups. Whereas AVP plasma levels remained constant in the placebo group, infusion of AVP increased AVP plasma levels up to 149 ± 21 pg/mL. Notably, treatment with the selective V2R-antagonist led to a significant decrease of AVP plasma levels as compared to shock time (P < 0.001) and to both other groups (P < 0.05 vs. placebo; P < 0.001 vs. AVP). Immunohistochemical analyses of lung tissue revealed higher hemeoxygenase-1 (vs. placebo) and lower 3-nitrotyrosine concentrations (vs. AVP) in the V2R-antagonist group. In addition, the selective V2R-antagonist slightly prolonged survival (14 ± 1 hour) when compared to AVP (11 ± 1 hour, P = 0.007) and placebo (11 ± 1 hour, P = 0.025). CONCLUSIONS : Selective V2R-antagonism may represent an innovative therapeutic approach to attenuate multiple organ dysfunction in early septic shock.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The spine is a complex structure that provides motion in three directions: flexion and extension, lateral bending and axial rotation. So far, the investigation of the mechanical and kinematic behavior of the basic unit of the spine, a motion segment, is predominantly a domain of in vitro experiments on spinal loading simulators. Most existing approaches to measure spinal stiffness intraoperatively in an in vivo environment use a distractor. However, these concepts usually assume a planar loading and motion. The objective of our study was to develop and validate an apparatus, that allows to perform intraoperative in vivo measurements to determine both the applied force and the resulting motion in three dimensional space. The proposed setup combines force measurement with an instrumented distractor and motion tracking with an optoelectronic system. As the orientation of the applied force and the three dimensional motion is known, not only force-displacement, but also moment-angle relations could be determined. The validation was performed using three cadaveric lumbar ovine spines. The lateral bending stiffness of two motion segments per specimen was determined with the proposed concept and compared with the stiffness acquired on a spinal loading simulator which was considered to be gold standard. The mean values of the stiffness computed with the proposed concept were within a range of ±15% compared to data obtained with the spinal loading simulator under applied loads of less than 5 Nm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) and total artificial hearts have been in development for the last 50 years. Since their inception, simulators of the circulation with different degrees of complexity have been produced to test these devices in vitro. Currently, a new path has been taken with the extensive efforts to develop paediatric VADs, which require totally different design constraints. This paper presents the manufacturing details of an economical simulator of the systemic paediatric circulation. This simulator allows the insertion of a paediatric VAD, includes a pumping ventricle, and is adjustable within the paediatric range. Rather than focusing on complexity and physiological simulation, this simulator is designed to be simple and practical for rapid device testing. The simulator was instrumented with medical sensors and data were acquired under different conditions with and without the new PediaFlowTM paediatric VAD. The VAD was run at different impeller speeds while simulator settings such as vascular resistance and stroke volume were varied. The hydraulic performance of the VAD under pulsatile conditions could be characterized and the magnetic suspension could be tested via manipulations such as cannula clamping. This compact mock loop has proven to be valuable throughout the PediaFlow development process and has the advantage that it is uncomplicated and can be manufactured cheaply. It can be produced by several research groups and the results of different VADs can then be compared easily.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Restenosis has been the principal limitation of bare metal stents. Based upon the presumption that platelet and inflammatory cell recruitment initiate neointimal proliferation, we explored a novel polymer coating that reduces cell-stent interactions. The purpose of the present study was to investigate the effect of poly(L-lysine)-graft-poly(ethyleneglycol) (PLL-g-PEG) adsorbed to stent surfaces to reduce neointimal hyperplasia in the porcine restenosis model. METHODS AND RESULTS: Seven animals were instrumented each with 2 stainless steel stents (15 mm length, 2.5-3.5 mm diameter), randomly implanted in 1 major epicardial coronary artery. One stent was dip-coated with PLL-g-PEG, whereas the other stent served as the uncoated control stent. All animals were sacrificed after 6 weeks for histological examination. Neointimal hyperplasia was significantly less (-51%) in the PLL-g-PEG-coated stents (1.15 +/- 0.59 mm2) than in the uncoated control stents (2.33 +/- 1.01 mm2; p < 0.001). Conversely, lumen size was larger in the PLL-g-PEG-coated stents (2.91 +/- 1.17 mm2) than in the uncoated stents (2.04 +/- 0.64 mm2; p < 0.001). High magnification histomorphologic examination revealed no signs of inflammation or thrombus formation in either stent group. CONCLUSIONS: Polymeric steric stabilization of stents with PLL-g-PEG significantly reduces neointimal hyperplasia in the porcine restenosis model. Reduction of cell-stent interactions mediated by PLL-g-PEG appear to improve biocompatibility of stainless steel stents without evidence of adverse inflammatory or prothrombotic effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The occurrence of degenerative spinal disease subsequent to dystonic movement disorders has been neglected and has received more attention only recently. Spinal surgery is challenging with regard to continuous mechanical stress when treatment of the underlying movement disorder is insufficient. To characterize better the particular features of degenerative spinal disease in patients with dystonia and to analyze operative strategies, we reviewed the available published data. Epidemiologic studies reveal that degenerative spinal disorders in patients with dystonia and choreoathetosis occur much earlier than in the physiological aging process. Dystonic movement disorders more often affect the spine at higher cervical levels (C(2-5)), in contrast to spinal degeneration with age which manifests more frequently at the middle and lower cervical spine (C(5-7)). Degenerative changes of the cervical spine are more likely to occur on the side where the chin is rotated or tilted to. Various operative approaches for treatment of spinal pathologies have been advocated in patients with dystonic movement disorders. The available data do not allow making firm statements regarding the superiority of one approach over the other. Posterior approaches were first used for decompression, but additional anterior fusion became necessary in many instances. Anterior approaches with or without instrumented fusion yielded more favorable results, but drawbacks are pseudarthrosis and adjacent-level disease. Parallel to the development of posterior fusion techniques, circumferential surgery was suggested to provide a maximum degree of cord decompression and a higher fusion rate. Perioperative local injections of botulinum toxin were used initially to enhance patient comfort with halo immobilization, but they are also applied in patients without external fixation nowadays. Treatment algorithms directed at the underlying movement disorder itself, taking advantage of new techniques of functional neurosurgery, combined with spinal surgery have recently been introduced and show promising results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cement augmentation using PMMA cement is known as an efficient treatment for osteoporotic vertebral compression fractures with a rapid release of pain in most patients and prevention of an ongoing kyphotic deformity of the vertebrae treated. However, after a vertebroplasty there is no chance to restore vertebral height. Using the technique of kyphoplasty a certain restoration of vertebral body height can be achieved. But there is a limitation of recovery due to loss of correction when deflating the kyphoplastic ballon and before injecting the cement. In addition, the instruments used are quite expensive. Lordoplasty is another technique to restore kyphosis by indirect fracture reduction as it is used with an internal fixateur. The fractured and the adjacent vertebrae are instrumented with bone cannulas bipediculary and the adjacent vertebrae are augmentated with cement. After curing of the cement the fractured vertebra is reduced by applying a lordotic moment via the cannulas. While maintaining the pretension the fractured vertebra is reinforced. We performed a prospective trial of 26 patients with a lordoplastic procedure. There was a pain relief of about 87% and a significant decrease in VAS value from 7.3 to 1.9. Due to lordoplasty there was a significant and permanent correction in vertebral and segmental kyphotic angle about 15.2 degrees and 10.0 degrees , respectively and also a significant restoration in anterior and mid vertebral height. Lordoplasty is a minimal invasive technique to restore vertebral body height. An immediate relief of pain is achieved in most patients. The procedure is safe and cost effective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: This study was designed to examine differences in the arteriolar vasoconstrictive response between arginine vasopressin (AVP) and norepinephrine (NE) on the microcirculatory level in the hamster window chamber model in unanesthetized, normotonic hamsters using intravital microscopy. It is known from patients with advanced vasodilatory shock that AVP exerts strong additional vasoconstriction when incremental dosage increases of NE have no further effect on mean arterial blood pressure (MAP). METHODS: In a prospective controlled experimental study, eleven awake, male golden Syrian hamsters were instrumented with a viewing window inserted into the dorsal skinfold. NE (2 microg/kg/minute) and AVP (0.0001 IU/kg/minute, equivalent to 4 IU/h in a 70 kg patient) were continuously infused to achieve a similar increase in MAP. According to their position within the arteriolar network, arterioles were grouped into five types: A0 (branch off small artery) to A4 (branch off A3 arteriole). RESULTS: Reduction of arteriolar diameter (NE, -31 +/- 12% versus AVP, -49 +/- 7%; p = 0.002), cross sectional area (NE, -49 +/- 17% versus AVP, -73 +/- 7%; p = 0.002), and arteriolar blood flow (NE, -62 +/- 13% versus AVP, -80 +/- 6%; p = 0.004) in A0 arterioles was significantly more pronounced in AVP animals. There was no difference in red blood cell velocities in A0 arterioles between groups. The reduction of diameter, cross sectional area, red blood cell velocity, and arteriolar blood flow in A1 to A4 arterioles was comparable in AVP and NE animals. CONCLUSION: Within the microvascular network, AVP exerted significantly stronger vasoconstriction on large A0 arterioles than NE under physiological conditions. This observation may partly explain why AVP is such a potent vasopressor hormone and can increase systemic vascular resistance even in advanced vasodilatory shock unresponsive to increases in standard catecholamine therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Low tissue oxygen tension is an important factor leading to the development of wound dehiscence and anastomotic leakage after colon surgery. We tested whether supplemental fluid and supplemental oxygen can increase tissue oxygen tension in healthy and injured, perianastomotic, and anastomotic colon in an acutely instrumented pig model of anastomosis surgery. METHODS: Sixteen Swiss Landrace pigs were anesthetized (isoflurane 0.8%-1%) and their lungs ventilated. The animals were randomly assigned to low fluid treatment ("low" group, 3 mL x kg(-1) x h(-1) lactated Ringer's solution) or high fluid treatment ("high" group, 10 mL/kg bolus, 18 mL x kg(-1) x h(-1) lactated Ringer's solution) during colon anastomosis surgery and a subsequent measurement period (4 h). Two-and-half hours after surgery, tissue oxygen tension was recorded for 30 min during ventilation with 30% oxygen. Three hours after surgery, the animals' lungs were ventilated with 100% oxygen for 60 min. Tissue oxygen tension was recorded in the last 30 min. Tissue oxygen tension was measured with polarographic Clark-type electrodes, positioned in healthy colonic wall, close (2 cm) to the anastomosis, and in the anastomosis. RESULTS: In every group, tissue oxygen tension during ventilation with 100% oxygen was approximately twice as high as during ventilation with 30% oxygen, a statistically significant result. High or low volume crystalloid fluid treatment had no effect on colon tissue oxygen tension. CONCLUSIONS: Supplemental oxygen, but not supplemental crystalloid fluid, increased tissue oxygen tension in healthy, perianastomotic, and anastomotic colon tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hooked reinforcing bars (rebar) are used frequently to carry the tension forces developed in beams and transferred to columns. Research into epoxy coated hooked bars has only been minimally performed and no research has been carried out incorporating the coating process found in ASTM A934. This research program compares hooked rebar that are uncoated, coated by ASTM A775, and coated by ASTM A934. In total, forty-two full size beam-column specimens were created, instrumented and tested to failure. The program was carried out in three phases. The first phase was used to refine the test setup and procedures. Phase two explored the spacing of column ties within the joint region. Phase three explored the three coating types found above. Each specimen included two hooked rebar which were loaded and measured independently for relative rebar slip. The load and displacement of the hooked rebar were analyzed, focusing on behavior at the levels of 30 ksi, 42 ksi and 60 ksi of rebar stress. Statistical and general comparisons were made using the coating types, tie spacing, and rebar stress level. Many of the parameters composing the rebar and concrete were also tested to characterize the components and specimens. All rebar tested met ASTM standards for tensile strength, but the newer ASTM A934 method seemed to produce slightly lower yield strengths. The A934 method also produced coating thicknesses that were very inconsistent and were higher than ASTM maximum limits in many locations. Continuity of coating surfaces was found to be less than 100% for both A775 and A934 rebar, but for different reasons. The many comparisons made did not always produce clear conclusions. The data suggests that the ACI Code (318-05) parameter of 1.2 for including epoxy coating on hooked rebar may need to be raised, possibly to 2.5, but more testing needs to be performed before such a large value change is set forth. This is particularly important as variables were identified which may have a larger influence on rebar capacity than the Development Length, of which the current 1.2 factor modifies. Many suggestions for future work are included throughout the thesis to help guide other researchers in carrying out successful and productive programs which will further the highly understudied topic of hooked rebar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report is a PhD dissertation proposal to study the in-cylinder temperature and heat flux distributions within a gasoline turbocharged direct injection (GTDI) engine. Recent regulations requiring automotive manufacturers to increase the fuel efficiency of their vehicles has led to great technological achievements in internal combustion engines. These achievements have increased the power density of gasoline engines dramatically in the last two decades. Engine technologies such as variable valve timing (VVT), direct injection (DI), and turbocharging have significantly improved engine power-to-weight and power-to-displacement ratios. A popular trend for increasing vehicle fuel economy in recent years has been to downsize the engine and add VVT, DI, and turbocharging technologies so that a lighter more efficient engine can replace a larger, heavier one. With the added power density, thermal management of the engine becomes a more important issue. Engine components are being pushed to their temperature limits. Therefore it has become increasingly important to have a greater understanding of the parameters that affect in-cylinder temperatures and heat transfer. The proposed research will analyze the effects of engine speed, load, relative air-fuel ratio (AFR), and exhaust gas recirculation (EGR) on both in-cylinder and global temperature and heat transfer distributions. Additionally, the effect of knocking combustion and fuel spray impingement will be investigated. The proposed research will be conducted on a 3.5 L six cylinder GTDI engine. The research engine will be instrumented with a large number of sensors to measure in-cylinder temperatures and pressures, as well as, the temperature, pressure, and flow rates of energy streams into and out of the engine. One of the goals of this research is to create a model that will predict the energy distribution to the crankshaft, exhaust, and cooling system based on normalized values for engine speed, load, AFR, and EGR. The results could be used to aid in the engine design phase for turbocharger and cooling system sizing. Additionally, the data collected can be used for validation of engine simulation models, since in-cylinder temperature and heat flux data is not readily available in the literature..

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One goal of interbody fusion is to increase the height of the degenerated disc space. Interbody cages in particular have been promoted with the claim that they can maintain the disc space better than other methods. There are many factors that can affect the disc height maintenance, including graft or cage design, the quality of the surrounding bone and the presence of supplementary posterior fixation. The present study is an in vitro biomechanical investigation of the compressive behaviour of three different interbody cage designs in a human cadaveric model. The effect of bone density and posterior instrumentation were assessed. Thirty-six lumbar functional spinal units were instrumented with one of three interbody cages: (1) a porous titanium implant with endplate fit (Stratec), (2) a porous, rectangular carbon-fibre implant (Brantigan) and (3) a porous, cylindrical threaded implant (Ray). Posterior instrumentation (USS) was applied to half of the specimens. All specimens were subjected to axial compression displacement until failure. Correlations between both the failure load and the load at 3 mm displacement with the bone density measurements were observed. Neither the cage design nor the presence of posterior instrumentation had a significant effect on the failure load. The loads at 3 mm were slightly less for the Stratec cage, implying lower axial stiffness, but were not different with posterior instrumentation. The large range of observed failure loads overlaps the potential in vivo compressive loads, implying that failure of the bone-implant interface may occur clinically. Preoperative measurements of bone density may be an effective tool to predict settling around interbody cages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Muscle strength greatly influences gait kinematics. The question was whether this association is similar in different diseases. METHODS Data from instrumented gait analysis of 716 patients were retrospectively assessed. The effect of muscle strength on gait deviations, namely the gait profile score (GPS) was evaluated by means of generalised least square models. This was executed for seven different patient groups. The groups were formed according to the type of disease: orthopaedic/neurologic, uni-/bilateral affection, and flaccid/spastic muscles. RESULTS Muscle strength had a negative effect on GPS values, which did not significantly differ amongst the different patient groups. However, an offset of the GPS regression line was found, which was mostly dependent on the basic disease. Surprisingly, spastic patients, who have reduced strength and additionally spasticity in clinical examination, and flaccid neurologic patients showed the same offset. Patients with additional lack of trunk control (Tetraplegia) showed the largest offset. CONCLUSION Gait kinematics grossly depend on muscle strength. This was seen in patients with very different pathologies. Nevertheless, optimal correction of biomechanics and muscle strength may still not lead to a normal gait, especially in that of neurologic patients. The basic disease itself has an additional effect on gait deviations expressed as a GPS-offset of the linear regression line.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The treatment of proximal humerus fractures in patients with poor bone quality remains a challenge in trauma surgery. Augmentation with polymethylmethacrylate (PMMA) cement is a possible method to strengthen the implant anchorage in osteoporotic bone and to avoid loss of reduction and reduce the cut-out risk. The polymerisation of PMMA during cement setting leads, however, to an exothermic reaction and the development of supraphysiological temperatures may harm the bone and cartilage. This study addresses the issue of heat development during augmentation of subchondrally placed proximal humerus plate screws with PMMA and the possible risk of bone and cartilage necrosis and apoptosis. METHODS Seven fresh frozen humeri from geriatric female donors were instrumented with the proximal humerus interlocking system (PHILOS) plate and placed in a 37°C water bath. Thereafter, four proximal perforated screws were augmented with 0.5 ml PMMA each. During augmentation, the temperatures in the subchondral bone and on the articular surface were recorded with K-type thermocouples. The measured temperatures were compared to threshold values for necrosis and apoptosis of bone and cartilage reported in the literature. RESULTS The heat development was highest around the augmented tips of the perforated screws and diminished with growing distance from the cement cloud. The highest temperature recorded in the subchondral bone reached 43.5°C and the longest exposure time above 42°C was 86s. The highest temperature measured on the articular surface amounted to 38.6°C and the longest exposure time above 38°C was 5 min and 32s. CONCLUSION The study shows that augmentation of the proximal screws of the PHILOS plate with PMMA leads to a locally limited development of supraphysiological temperatures in the cement cloud and closely around it. The critical threshold values for necrosis and apoptosis of cartilage and subchondral bone reported in the literature, however, are not reached. In order to avoid cement extravasation, special care should be taken in detecting perforations or intra-articular cracks in the humeral head.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Joint hypermobility is known to be associated with joint and muscle pain, joint instability and osteoarthritis. Previous work suggested that those individuals present an altered neuromuscular behavior during activities such as level walking. Therefore, the aim of this study was to explore the differences in ground reaction forces, temporal parameters and muscle activation patterns during gait between normomobile and hypermobile women, including symptomatic and asymptomatic hypermobile individuals. METHODS A total of 195 women were included in this cross-sectional study, including 67 normomobile (mean 24.8 [SD 5.4] years) and 128 hypermobile (mean 25.8 [SD 5.4] years), of which 56 were further classified as symptomatic and 47 as asymptomatic. The remaining 25 subjects could not be further classified. Ground reaction forces and muscle activation from six leg muscles were measured while the subjects walked at a self-selected speed on an instrumented walkway. Temporal parameters were derived from ground reaction forces and a foot accelerometer. The normomobile and hypermobile groups were compared using independent samples t-tests, whereas the normomobile, symptomatic and asymptomatic hypermobile groups were compared using one-way ANOVAs with Tukey post-hoc tests (significance level=0.05). FINDINGS Swing phase duration was higher among hypermobile (P=0.005) and symptomatic hypermobile (P=0.018) compared to normomobile women. The vastus medialis (P=0.049) and lateralis (P=0.030) and medial gastrocnemius (P=0.011) muscles showed higher mean activation levels during stance in the hypermobile compared to the normomobile group. INTERPRETATION Hypermobile women might alter their gait pattern in order to stabilize their knee joint.