954 resultados para Electrical resistances


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amorphous SiC(x)N(y) films have been deposited on (100) Si substrates by RF magnetron sputtering of a SiC target in a variable nitrogen-argon atmosphere. The as-deposited films were submitted to thermal anneling in a furnace under argon atmosphere at 1000 degrees C for 1 hour. Composition and structure of unannealed and annealed samples were investigated by RBS and FTIR. To study the electrical characteristics of SiC(x)N(y) films, Metal-insulator-semiconductor (MIS) structures were fabricated. Elastic modulus and hardness of the films were determined by nanoindentation. The results of these studies showed that nitrogen content and thermal annealing affect the electrical, mechanical and structural properties of SiC(x)N(y) films.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Bi-Sr-Ca-Cu-O system has been one of the most studied superconducting ceramic materials for industry applications. The most of the studies with this aim are on silver/ceramic composites, due to the benefits and great compatibility of this metal with the oxide. In this paper we describe a systematic and comparative study on Ag/BSCCO composite, made by the citrate route, in which the ceramic pellets are sintered in the presence of silver powder using several proportions and having several granulations. It was observed that the introduction of fine (0.5 and 2 μm) silver powder in the proportions of 5 wt. % always implies in a better critical current density compared to the no silver pellet. According to the results, the silver powder in excess of 5 wt.% may not promote best electrical properties, depending on the size of the silver particles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the electrical behavior pattern of the Rectus abdominis muscle by qualitative and quantitative analysis of the electromyographic signal obtained from its superior, medium and inferior portions during dynamic and static activities. Ten voluntaries (aged X = 17.8 years, SD = 1.6) athletic males were studied without history of muscle skeletal disfunction. For the quantitative analysis the RMS (Root Mean Square) values obtained in the electromyographic signal during the isometric exercises were normalized and expressed in maximum voluntary isometric contraction percentages. For the qualitative analysis of the dynamic activity the electromyographic signal was processed by full-wave rectification, linear envelope and normalization (amplitude and time), so that the resulting curve of the processed signal was submitted to descriptive graphic analysis. The results of the quantitative study show that there is not a statistically significant difference among the portions of the muscle. Qualitative analysis demonstrated two aspects: the presence of a common activation electric pattern in the portions of Rectus abdominis muscle and the absence of significant difference in the inclination angles in the electrical activity curve during the isotonic exercises.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To validate a model for investigating the effects of analgesic drugs on mechanical, thermal and electrical stimulation testing. To investigate repeatability, sensitivity and specificity of nociceptive tests. Randomised experiment with 2 observers in 2 phases. Mechanical (M), thermal (TL) and electrical (E) stimuli were applied to the dorsal metacarpus (M-left and TL-right) and coronary band of the left thoracic limb (E) and a thoracic thermal stimulus (TT) was applied caudal to the withers in 8 horses (405 ± 43 kg). Stimuli intensities were increased until a clear avoidance response was detected without exceeding 20 N (M), 60°C (TL and TT) and 15 V (E). For each set of tests, 3 real stimuli and one sham stimulus were applied (32 per animal) using a blinded, randomised, crossover design repeated after 6 months. A distribution frequency and, for each stimulus, Chi-square and McNemar tests compared both the proportion of positive responses detected by 2 observers and the 2 study phases. The κ coefficients estimated interobserver agreement in determining endpoints. Sensitivity (384 tests) and specificity (128 tests) were evaluated for each nociceptive stimulus to assess the evaluators' accuracy in detecting real and sham stimuli. Nociceptive thresholds were 3.1 ± 2 N (M), 8.1 ± 3.8 V (E), 51.4 ± 5.5°C (TL) and 55.2 ± 5.3°C (TT). The level of agreement after all tests, M, E, TL and TT, was 90, 100, 84, 98 and 75%, respectively. Sensitivity was 89, 100, 89, 98 and 70% and specificity 92, 97, 88, 91 and 94%, respectively. The high interobserver agreement, sensitivity and specificity suggest that M, E and TL tests are valid for pain studies in horses and are suitable tools for investigating antinociceptive effects of analgesics in horses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim is to evaluate the influence of oral contraceptive intake and menstrual cycle on the electrical activity and pressure pain threshold from anterior temporal and masseter muscles. Twenty-eight women on reproductive age were selected, 13 OC users and 15 nonusers. They were weekly submitted to electromyography and algometry of the anterior temporal and masseter muscles during three consecutive menstrual cycles. Electrical activities at rest position and PPTs of temporal and masseter muscles were not affected by menstrual cycle or by OCs uses. Comparison between groups demonstrated that working side electrical activity was increased in OC users in both muscles, except during lutheal phase for the anterior temporal. However, comparison within weeks did not demonstrate statistical difference. It was suggested that, in healthy women, oral contraceptive use may influence electrical activity, but different phases of the cycle may not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biogas originated from anaerobic degradation of organic matter in landfills consists basically in CH4, CO2, and H2O. The landfills represent an important depository of organic matter with high energetic potential in Brazil, although with inexpressive use in the present. The estimation of production of the productive rate of biogas represents one of the major difficulties of technical order to the planning of capture system for rational consumption of this resource. The applied geophysics consists in a set of methods and techniques with wide use in environmental and hydrogeological studies. The DC resistivity method is largely applied in environmental diagnosis of the contamination in soil and groundwater, due to the contrast of electrical properties frequent between contaminated areas and the natural environment. This paper aims to evaluate eventual relationships between biogas flows quantified in drains located in the landfill, with characteristic patterns of electrical resistivity in depth. The drain of higher flow (117 m3 /h) in depth was characterized for values between 8000 Ω⋅m and 100.000 Ω⋅m, in contrast with values below 2000 Ω⋅m, which characterize in subsurface the drain with less flow (37 m3 /h), besides intermediary flow and electrical resistivity values, attributed to the predominance of areas with accumulation or generation of biogas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of deposition parameters, namely polymer concentration and pH of the deposition solution, cleaning, and drying steps on the morphology and electrical characteristics of polyaniline and sulfonated polystyrene (PANI/PSS) nanostructured films deposited by the self-assembly technique is evaluated by UV-Vis spectroscopy, optical and atomic force microscopy, and electrical resistance measurements. It is found that stirring the cleaning solution during the cleaning step is crucial for obtaining homogenous films. Stirring of the cleaning solution also influences the amount of PANI adsorbed in the films. In this regard, the drying process seems to be less critical since PANI amount and film thickness are similar in films dried with N-2 flow or with an absorbent tissue. It is observed, however, that drying with N-2 flow results in rougher films. As an additional point, an assessment of the influence of the deposition method (manual versus mechanical) on the film characteristics was carried out. A significant difference on the amount of PANI and film thickness between films prepared by different human operators and by a homemade mechanical device was observed. The variability in film thickness and PANI adsorbed amount is smaller in films mechanically assembled. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a ruthenium hexafluorophosphate complex, [Ru(bpy)(3)](PF6)(2) in poly(methylmethacrylate) (PMMA) was employed to build a single layer light electrochemical cell on indium tin oxide polyester flexible substrate. The electroluminescence spectrum features a relatively broad band peaked near 625 run, with CIE (x,y) color coordinates of (0.61,0.39). The driving voltage is only 3 V, and for the maximum electrical current of 10 mA the brightness reaches 1 cd/m(2). Regarding the useful application of the device, its opto-electrical behavior under mechanical strain was studied considering the central curvature. In these situations, both electrical characterization in DC mode and luminance were analyzed. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complete I-V characteristics of SnO(2)-based varistors, particularly of the Pianaro system SCNCr consisting in 98.9%SnO(2)+1%CoO+0.05%Nb(2)O(5)+0.05%Cr(2)O(3), all in mol%, have been seldom reported in the literature. A comparative study at low and high currents of the nonohmic behavior of SCNCr- and ZnO-based varistors (modified Matsuoka system) is proposed in this work. The SCNCr system showed higher nonlinearity coefficients in the whole range of measured current. The electrical breakdown field (E(b)) was twice as high for the SCNCr system (5400 V/cm) than for the ZnO varistor (2600 V/cm) due to a smaller average grain size of the former (4.5 mu m) with respect to the latter (8.5 mu m). Nevertheless, we consider that another important factor responsible for the high E(b) in the SCNCr system is the great number of electrically active interfaces (85%) as determined with electrostatic force microscopy (EFM). It was also established that the SCNCr system might be produced in disks of smaller dimensions than that of commercial ZnO-based product, with a 5.0 cm(-1) minimal area-volume (A/V) ratio. The SCNCr reached the saturation current in a short time because of the high resistivity of the grains, which is five times higher than that of the grains in ZnO-based varistors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The use of noninvasive cortical electrical stimulation with weak currents has significantly increased in basic and clinical human studies. Initial, preliminary studies with this technique have shown encouraging results; however, the safety and tolerability of this method of brain stimulation have not been sufficiently explored yet. The purpose of our study was to assess the effects of direct current (DC) and alternating current (AC) stimulation at different intensities in order to measure their effects on cognition, mood, and electroencephalogram. Methods: Eighty-two healthy, right-handed subjects received active and sham stimulation in a randomized order. We conducted 164 ninety-minute sessions of electrical stimulation in 4 different protocols to assess safety of (1) anodal DC of the dorsolateral prefrontal cortex (DLPFC); (2) cathodal DC of the DLPFC; (3) intermittent anodal DC of the DLPFC and; (4) AC on the zygomatic process. We used weak currents of 1 to 2 mA (for DC experiments) or 0.1 to 0.2 mA (for AC experiment). Results: We found no significant changes in electroencephalogram, cognition, mood, and pain between groups and a low prevalence of mild adverse effects (0.11% and 0.08% in the active and sham stimulation groups, respectively), mainly, sleepiness and mild headache that were equally distributed between groups. Conclusions: Here, we show no neurophysiological or behavioral signs that transcranial DC stimulation or AC stimulation with weak currents induce deleterious changes when comparing active and sham groups. This study provides therefore additional information for researchers and ethics committees, adding important results to the safety pool of studies assessing the effects of cortical stimulation using weak electrical currents. Further studies in patients with neuropsychiatric disorders are warranted.