1000 resultados para Craniometric measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reliable measurement of the electron energy distribution function (EEDF) of plasmas is one of the most important subjects of plasma diagnostics, because this piece of information is the key to understand basic discharge mechanisms. Specific problems arise in the case of RF-excited plasmas, since the properties of electrons are subject to changes on a nanosecond time scale and show pronounced spatial anisotropy. We report on a novel spectroscopic method for phase- and space-resolved measurements of the electron energy distribution function of energetic (> 12 eV) electrons in RF discharges. These electrons dominate excitation and ionization processes and are therefore of particular interest. The technique is based on time-dependent measurements during the RF cycle of excited-state populations of rare gases admixed in small fractions. These measurements yield � in combination with an analytical model � detailed information on the excitation processes. Phase-resolved optical emission spectroscopy allows us to overcome the difficulties connected with the very low densities (107�109 cm�3) and the transient character of the electrons in the sheath region. The EEDF of electrons accelerated in the sheath region can be described by a shifted Maxwellian with a drift velocity component in direction of the electric field. The method yields the high-energy tail of the EEDF on an absolute scale. The applicability of the method is demonstrated at a capacitively coupled RF discharge in hydrogen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Short liquid core waveguides (LCWs) were included into a fiber-loop cavity ring-down absorption spectrometer to reduce the detection limit over, both, single pass absorption in a LCW and cavityenhanced absorption using a conventional fiber-loop cavity. LCWs of 5 and 10 cm length were interfaced with a pressure-flow system and a multimode fiber-loop cavity using concave fiber lenses with matching numerical apertures and diameters. Two red dyes, Allura Red AC and Congo Red, were detected with a 532 nm pulsed laser at a 5 nM limit of detection in a detection volume of less than 1 μL, corresponding to a minimal detectable absorbance of less than 4 × 10−4 cm−1 and a minimal detectable change in absorption cross section, σmin = Vdet × ε × CLOD, of about 14 μm2 (Allura Red AC) and 37 μm2 (Congo Red).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optical loss of whispering gallery modes of resonantly excited microresonator spheres is determined by optical lifetime measurements. The phase-shift cavity ring-down technique is used to extract ring-down times and optical loss from the difference in amplitude modulation phase between the light entering the microresonator and light scattered from the microresonator. In addition, the phase lag of the light exiting the waveguide, which was used to couple light into the resonator, was measured. The intensity and phase measurements were fully described by a model that assumed interference of the cavity modes with the light propagating in the waveguide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crossed-beams energy-loss spectrometer has been used to investigate angular distributions for electron scattering from Ar2+ and Xe2+ ions, at a collision energy of 16 eV. For Ar2+ the measurements are compared with the predictions of a partial waves calculation based on a semi-empirical potential, where it is shown that the interference term governs the position of the observed minimum in the angular distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of PVT measurements of the liquid phase within the temperature range of (298 to 393) K and up to 35 MPa are presented for some aliphatic esters. Measurements were made by means of a vibrating-tube densimeter, model DMA 512P from Anton Parr. The calibration of the densimeter was performed with water and n-heptane as reference fluids. The experimental PVT data have been correlated by a Tait equation. This equation gives excellent results when used to predict the density of the esters using the method proposed by Thomson et al. (AIChE J. 1982, 28, 671-676). Isothermal compressibilities, isobaric expansivities, thermal pressure coefficients, and changes in the isobaric heat capacity have been calculated from the volumetric data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental density measurements are reported, and the derived thermodynamic properties, such as the isothermal compressibility, the isobaric expansivity, and the thermal pressure coefficient are presented as Supporting Information for several imidazolium-based ionic liquids (ILs), namely, 1-ethyl-3-methyl-imidazolium bis(trifluoromethylsulfonyl)imide [C2mim][NTf2], 1-heptyl-3-methyl-imidazolium bis(trifluoromethylsulfonyl)imide [C7mim][NTf2], 1-octyl-3-methyl-imidazolium bis(trifluoromethylsulfonyl)imide [C8mim][NTf2], 1-ethyl-3-methyl-imidazolium tetrafluoroborate [C2mim][BF4], and 1-butyl-3-methyl-imidazolium tricyanomethane [C4mim][C(CN)3] in the pressure (0.10 <p/MPa <30.00) and temperature (293.15 <T/K <393.15) domains. These ILs were chosen to provide an understanding of the influence of the cation alkyl chain length and the anion influence on the properties under study. Experimental densities are correlated with the Tait equation with an average absolute deviation (AAD) less than 0.04 %. Experimental densities are in good agreement with the densities obtained by some recent predictive methods proposed in the literature.