839 resultados para Applied Linguistics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high performance Time-of-Flight detector has been designed and constructed for isochronous mass spectrometry at the experimental Cooler Storage Ring (CSRe) The detector has been successfully used in an experiment to measure the masses of the N approximate to Z approximate to 33 nuclides near the proton drip-line Of particular interest is the mass of As-65 A maximum detection efficiency of 70% and a time resolution of 118 +/- 8 Ps (FWHM) have been achieved in the experiment The dependence of detection efficiency and signal average pulse height (APH) on atomic number Z has been studied The potential of APH for Z identification has been discussed (C) 2010 Elsevier B V All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser-induced breakdown spectroscopy (LIBS) as a powerful analytical technique is applied to analyze trace-elements in fresh plant samples. We investigate the LIBS spectra of fresh holly leaves and observe more than 430 lines emitted from 25 elements and molecules in the region 230-438 nm. The influence of laser wavelength on LIBS applied to semi-quantitative analysis of trace-element contents in plant samples is studied. The results show that the UV laser has lower relative standard deviations and better repeatability for semi-quantitative analysis of trace-element contents in plant samples. This work may be helpful for improving the quantitative analysis power of LIBS applied to plant samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high-throughput screening system for secondary catalyst libraries has been developed by incorporation of an 80-pass reactor and a quantified multistream mass spectrometer screening (MSMSS) technique. With a low-melting alloy as the heating medium, a uniform reaction temperature could be obtained in the multistream reactor (maximum temperature differences are less than 1 K at 673 K). Quantification of the results was realized by combination of a gas chromatogram with the MSMSS, which could provide the product selectivities of each catalyst in a heterogeneous catalyst library. Because the catalyst loading of each reaction tube is comparable to that of the conventional microreaction system and because the parallel reactions could be operated under identical conditions (homogeneous temperature, same pressure and WHSV), the reaction results of a promising catalyst selected from the library could be reasonably applied to the further scale-up of the system. The aldol condensation of acetone, with obvious differences in the product distribution over different kind of catalysts, was selected as a model reaction to validate the screening system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymethacrylate-based monolithic columns were prepared for capillary electrochromatography (CEC) by in situ copolymerization of butyl methacrylate (BMA), 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS), and ethylene dimethacrylate (EDMA) in the presence of a porogen in fused-silica capillaries of 100 mum I.D. The abnormal phenomenon that retention factors for neutral species decreases with applied voltage in CEC was observed. Capillary electrophoresis (CE) instruments usually require a period of time to increase voltage from 0 kV to desired value, which is called as ramp time. Such ramp time and any error in the determination of dead time should be taken into account during the accurate calculation of retention factors. After the correction of the retention factors, the plots of the corrected factors for alkylbenzene versus applied voltage were made, the absolute value of the plot slopes are less than 1.8 X 10(-4), Which indicates that the corrected retention times for neutral species do not show any dependence on applied voltage. Further, the plots of the corrected retention times for acidic and basic compounds versus the reciprocal of applied voltage were drawn, where the target compounds were eluted in neutral form. The very nice linearity of the plots was obtained. The linear correlation coefficients are over 0.999. Here, the slopes of the plots represent

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with Ru(bpy)(3)(2+) electrochemiluminescence. (ECL) detection system was established to the determination of contamination of banknotes with controlled drugs and a high efficiency on-column field-amplified sample stacking (FASS) technique was also optimized to increase the ECL intensity. The method was illustrated using heroin and cocaine, which are two typical and popular illicit drugs. Highest sample stacking was obtained when 0.01 mM acetic acid was chosen for sample dissolution with electrokinetical injection for 6 s at 17 kV. Under the optimized conditions: ECL detection at 1.2 V, separation voltage 10.0 kV, 20 mM phosphate-acetate (pH 7.2) as running buffer, 5 mM Ru(bpy)(3)(2+) with 50 mM phosphate-acetate (pH 7.2) in the detection cell, the standard curves were linear in the range of 7.50 x 10(-8) to 1.00 x 10(-5) M for heroin and 2.50 x 10(-7) to 1.00 x 10(-4) M for cocaine and detection limits of 50 nM for heroin and 60 nM for cocaine were achieved (S/N = 3), respectively. Relative standard derivations of the ECL intensity and the migration time were 3.50 and 0.51% for heroin and 4.44 and 0.12% for cocaine, respectively.The developed method was successfully applied to the determination of heroin and cocaine on illicit drug contaminated banknotes without any damage of the paper currency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artificial neural network(ANN) approach was applied to classification of normal persons and lung cancer patients based on the metal content of hair and serum samples obtained by inductively coupled plasma atomic emission spectrometry (ICP-AES) for the two groups. This method was verified with independent prediction samples and can be used as an aiding means of the diagnosis of lung cancer. The case of predictive classification with one element missing in the prediction samples was studied in details, The significance of elements in hair and serum samples for classification prediction was also investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method to assign a single number representation for each atom (node) in a molecular graph, Atomic IDentification (AID) number, is proposed based on the counts of weighted paths terminated on that atom. Then, a new topological index, Molecular IDentification (MID) number is developed from AID. The MID is tested systematically, over half a million of structures are examined, and MID shows high discrimination for various structural isomers. Thus it can be used for documentation in the Changchun Institute of Chemistry C-13 NMR information system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of applying the method of factor analysis to X-ray diffraction diagrams of binary blends of polypropylene and ethylene-propylene-diene terpolymer (PP/EPDM) was examined. The result of mathematical treatment was satisfactory. The number of scattering species and their concentrations in six kinds of PP/EPDM blends were determined. The separation of the spectral peaks of each species in the blends, contributing spectral intensities, was carried out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a thiourea-modified chitosan derivative (TMCD) was synthesized through two steps, O-carboxymethylated first and then modified by a polymeric Schiff's base of thiourea/glutaraldehyde. The adsorption behavior of mercury (II) ions onto TMCD was investigated through batch method. The maximum adsorption capacity for Hg(II) was found to be 6.29 mmol/g at pH 5.0 and both kinetic and thermodynamic parameters of the adsorption process were obtained. The results indicated that adsorption process was spontaneous exothermic reaction and kinetically followed pseudo-second-order model. The adsorption experiments also demonstrated TMCD had high adsorption selectivity towards Hg(II) ions when coexisted with Cu(II), Zn(II), Cd(II) and Ca(II) in solution and it could be easily regenerated and efficiently reused. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes a computational system with which phonologists may describe a natural language in terms of autosegmental phonology, currently the most advanced theory pertaining to the sound systems of human languages. This system allows linguists to easily test autosegmental hypotheses against a large corpus of data. The system was designed primarily with tonal systems in mind, but also provides support for tree or feature matrix representation of phonemes (as in The Sound Pattern of English), as well as syllable structures and other aspects of phonological theory. Underspecification is allowed, and trees may be specified before, during, and after rule application. The association convention is automatically applied, and other principles such as the conjunctivity condition are supported. The method of representation was designed such that rules are designated in as close a fashion as possible to the existing conventions of autosegmental theory while adhering to a textual constraint for maximum portability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L. Blot, A. Davis, M. Holubinka, R. Marti and R. Zwiggelaar, 'Automated quality assurance applied to mammographic imaging', EURASIP Journal of Applied Signal Processing 2002 (7), 736-745 (2002)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wydział Neofilologii: Instytut Filologii Angielskiej

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wydział Biologii: Instytut Antropologii

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Until recently, little was known about the costs of the HIV/AIDS epidemic to businesses in Africa and business responses to the epidemic. This paper synthesizes the results of a set of studies conducted between 1999 and 2006 and draws conclusions about the role of the private sector in Africa’s response to AIDS. Methods: Detailed human resource, financial, and medical data were collected from 14 large private and parastatal companies in South Africa, Uganda, Kenya, Zambia, and Ethiopia. Surveys of small and medium-sized enterprises (SMEs) were conducted in South Africa, Kenya, and Zambia. Large companies’ responses or potential responses to the epidemic were investigated in South Africa, Uganda, Kenya, Zambia, and Rwanda. Results: Among the large companies, estimated workforce HIV prevalence ranged from 5%¬37%. The average cost per employee lost to AIDS varied from 0.5-5.6 times the average annual compensation of the employee affected. Labor cost increases as a result of AIDS were estimated at anywhere from 0.6%-10.8% but exceeded 3% at only 2 of 14 companies. Treatment of eligible employees with ART at a cost of $360/patient/year was shown to have positive financial returns for most but not all companies. Uptake of employer-provided testing and treatment services varied widely. Among SMEs, HIV prevalence in the workforce was estimated at 10%-26%. SME managers consistently reported low AIDS-related employee attrition, little concern about the impacts of AIDS on their companies, and relatively little interest in taking action, and fewer than half had ever discussed AIDS with their senior staff. AIDS was estimated to increase the average operating costs of small tourism companies in Zambia by less than 1%; labor cost increases in other sectors were probably smaller. Conclusions: Although there was wide variation among the firms studied, clear patterns emerged that will permit some prediction of impacts and responses in the future.