903 resultados para total phenolics
Resumo:
High-pressure processing (HPP) can produce tomato juice of high quality and safety with a short shelf life under refrigeration temperatures. Long-term higher temperature storage studies are rare and temperature tolerant products are challenging to develop. The effect of high-pressure processing (HPP) on the total quality (colour, microbial counts, phytochemical levels, antioxidant and enzymatic activities) and stability (retention over time) of tomato juice during long-term storage was investigated. Thermal processing (TP) was used as a control treatment, and overall, two different ambient conditions (20 °C and 28 °C) were tested. Immediately after processing, HPP products proved superior to TP ones (enhanced redness, total carotenoids and lycopene, stable total phenols and inactivation of pectin methyl esterase). During initial storage (30 d) most quality attributes of HPP juice remained stable. Prolonged storage, however, led to losses of most quality attributes, although HPP (20 °C) showed lower quality degradation rate constants comparison to TP and HPP (28 °C). Industrial Relevance: There is a demand for ambient stable tomato products, especially in some parts of the world, and current industrial practices (canning, pasteurisation) either compromise in product quality or require refrigeration conditions. High-pressure processing has been investigated as milder technology, with a potential to deliver superior quality. The drawback is that is also requires chill storage. The results of this study show how quality parameters behave in a high-pressured tomato product and pave the way for further development that could optimise this technology. This could be of economic importance for the tomato juice industry to develop new products stable in ambient temperatures and perhaps beneficial for cutting down the refrigeration costs under specific conditions.
Resumo:
This work investigated the differences in the reactivity of Sarda (primiparous n= 18, multiparous n= 17) and Dorset (multiparous n= 8) breeds of sheep and their singleton lambs to two challenging test situations involving a mother-lamb partial separation test and an isolation test. Non-parametric analysis used single behavioural variables and fear scores to evaluate the effect of parity, sex of lambs, and the association between mother-lamb behaviour. Amongst ewes, Dorset were characterised by a more calm temperament while Sarda (especially primiparous ewes) were more active in their response to challenge (i.e. more attempts to escape). As with their dams, lambs reflected to a certain extent this divergence and overall during isolation lamb fear score was on average significantly higher than dams. Correlations between measures of behavioural reactivity across tests were carried out to search for predictive measures of fear. A very strong correlation emerged linking vocalisation to locomotor activity. Vocalisation could be a good candidate as predictor factor of an active reaction of sheep to a fearful situation.
Resumo:
O presente trabalho descreve um projeto de implementação da metodologia de Manutenção Produtiva Total (TPM) desenvolvido na Simoldes Plásticos, unidade industrial de injeção de plásticos que opera no setor automóvel. A metodologia TPM salienta o papel fundamental que o trabalho em equipa e, em particular, a participação do pessoal, podem desempenhar na identificação de oportunidades de melhoria e na sua implementação. A sua aplicação visa a diminuição dos desperdícios, acidentes, defeitos, paragens e falhas ao longo de um processo produtivo. De uma forma geral, a TPM utiliza uma ideia base elementar que passa pela sensibilização, formação e treino dos operadores para que estes consigam realizar a manutenção autónoma dos equipamentos e melhorar continuamente o seu desempenho. Este trabalho apresenta em primeiro lugar uma revisão dos conceitos de Gestão da Qualidade Total, particularmente da Melhoria Contínua e da Metodologia TPM. De seguida, é descrita a aplicação da TPM na empresa Simoldes Plásticos, que inclui uma descrição dos principais problemas encontrados e das medidas aplicadas para a sua correção. Finalmente é feita uma análise do impacto das melhorias implementadas, a partir da análise de um indicador de eficiência específico, desenvolvido na empresa - o RUTPM - Rendimento de Utilização TPM.
Resumo:
Tese de doutoramento, Ciências Biotecnológicas (Biotecnologia Alimentar), Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2014
Resumo:
Objective: To evaluate the feasibility of conducting a randomized controlled trial comparing group-based outpatient physiotherapy with usual care in patients following total knee replacement. Design: A feasibility study for a randomized controlled trial. Setting: One secondary-care hospital orthopaedic centre, Bristol, UK. Participants: A total of 46 participants undergoing primary total knee replacement. Interventions: The intervention group were offered six group-based exercise sessions after surgery. The usual care group received standard postoperative care. Participants were not blinded to group allocation. Outcome measures: Feasibility was assessed by recruitment, reasons for non-participation, attendance, and completion rates of study questionnaires that included the Lower Extremity Functional Scale and Knee Injury and Osteoarthritis Outcome Score. Results: Recruitment rate was 37%. Five patients withdrew or were no longer eligible to participate. Intervention attendance was high (73%) and 84% of group participants reported they were ‘very satisfied’ with the exercises. Return of study questionnaires at six months was lower in the usual care (75%) than in the intervention group (100%). Mean (standard deviation) Lower Extremity Functional Scale scores at six months were 45.0 (20.8) in the usual care and 57.8 (15.2) in the intervention groups. Conclusion: Recruitment and retention of participants in this feasibility study was good. Group-based physiotherapy was acceptable to participants. Questionnaire return rates were lower in the usual care group, but might be enhanced by telephone follow-up. The Lower Extremity Functional Scale had high responsiveness and completion rates. Using this outcome measure, 256 participants would be required in a full-scale randomized controlled trial.
Resumo:
To what extent are democratic institutions resilient when nation states mobilise for war? Normative and empirical political theorists have long argued that wars strengthen the executive and threaten constitutional politics. In modern democracies, national assemblies are supposed to hold the executive to account by demanding explanations for events and policies; and by scrutinising, reviewing and, if necessary, revising legislative proposals intended to be binding on the host society or policies that have been implemented already. This article examines the extent to which the British and Australian parliaments and the United States Congress held their wartime executives to account during World War II. The research finds that under conditions approaching those of total war, these democratic institutions not only continued to exist, but also proved to be resilient in representing public concerns and holding their executives to account, however imperfectly and notwithstanding delegating huge powers. In consequence, executives—more so British and Australian ministers than President Roosevelt—were required to be placatory as institutional and political tensions within national assemblies and between assemblies and executives continued, and assemblies often asserted themselves. In short, even under the most onerous wartime conditions, democratic politics mattered and democratic institutions were resilient.
Resumo:
We used1H-magnetic resonance spectroscopy to noninvasively determine total creatine (TCr), choline-containing compounds (Cho), and intracellular (IT) and extracellular (between-muscle fibers) triglycerides (ET) in three human skeletal muscles. Subjects' (n = 15 men) TCr concentrations in soleus [Sol; 100.2 ± 8.3 (SE) mmol/kg dry wt] were lower (P < 0.05) than those in gastrocnemius (Gast; 125.3 ± 9.2 mmol/kg dry wt) and tibialis anterior (TA; 123.7 ± 8.8 mmol/kg dry wt). The Cho levels in Sol (35.8 ± 3.6 mmol/kg dry wt) and Gast (28.5 ± 3.5 mmol/kg dry wt) were higher (P < 0.001 andP < 0.01, respectively) compared with TA (13.6 ± 2.4 mmol/kg dry wt). The IT values were found to be 44.8 ± 4.6 and 36.5 ± 4.2 mmol/kg dry wt in Sol and Gast, respectively. The IT values of TA (24.5 ± 4.5 mmol/kg dry wt) were lower than those of Sol (P < 0.01) and Gast (P < 0.05). There were no differences in ET [116.0 ± 11.2 (Sol), 119.1 ± 18.5 (Gast), and 91.4 ± 19.2 mmol/kg dry wt (TA)]. It is proposed that the differences in metabolite levels may be due to the differences in fiber-type composition and deposition of metabolites due to the adaptation of different muscles during locomotion.
Resumo:
In this paper, it was evaluated the total antioxidant capacity (TAC) of beverages using an electrochemical biosensor. The biosensor consisted on the purine base (guanine or adenine) electro-immobilization on a glassy carbon electrode surface (GCE). Purine base damage was induced by the hydroxyl radical generated by Fenton-type reaction. Five antioxidants were applied to counteract the deleterious effects of the hydroxyl radical. The antioxidants used were ascorbic acid, gallic acid, caffeic acid, coumaric acid and resveratrol. These antioxidants have the ability to scavenger the hydroxyl radical and protect the guanine and adenine immobilized on the GCE surface. The interaction carried out between the purinebase immobilized and the free radical in the absence and presence of antioxidants was evaluated by means of changes in the guanine and adenine anodic peak obtained by square wave voltammetry (SWV). The results demonstrated that the purine-biosensors are suitable for rapid assessment of TAC in beverages.
Resumo:
Total petroleum hydrocarbons (TPH) are important environmental contaminants which are toxic to human and environmental receptors. Several analytical methods have been used to quantify TPH levels in contaminated soils, specifically through infrared spectrometry (IR) and gas chromatography (GC). Despite being two of the most used techniques, some issues remain that have been inadequately studied: a) applicability of both techniques to soils contaminated with two distinct types of fuel (petrol and diesel), b) influence of the soil natural organic matter content on the results achieved by various analytical methods, and c) evaluation of the performance of both techniques in analyses of soils with different levels of contamination (presumably non-contaminated and potentially contaminated). The main objectives of this work were to answer these questions and to provide more complete information about the potentials and limitations of GC and IR techniques. The results led us to the following conclusions: a) IR analysis of soils contaminated with petrol is not suitable due to volatilisation losses, b) there is a significant influence of organic matter in IR analysis, and c) both techniques demonstrated the capacity to accurately quantify TPH in soils, irrespective of their contamination levels.
Resumo:
In this paper, a biosensor based on a glassy carbon electrode (GCE) was used for the evaluation of the total antioxidant capacity (TAC) of flavours and flavoured waters. This biosensor was constructed by immobilising purine bases, guanine and adenine, on a GCE. Square wave voltammetry (SWV) was selected for the development of this methodology. Damage caused by the reactive oxygen species (ROS), superoxide radical (O2·−), generated by the xanthine/xanthine oxidase (XOD) system on the DNA-biosensor was evaluated. DNA-biosensor encountered with oxidative lesion when it was in contact with the O2·−. There was less oxidative damage when reactive antioxidants were added. The antioxidants used in this work were ascorbic acid, gallic acid, caffeic acid, coumaric acid and resveratrol. These antioxidants are capable of scavenging the superoxide radical and therefore protect the purine bases immobilized on the GCE surface. The results demonstrated that the DNA-based biosensor is suitable for the rapid assess of TAC in beverages.
Resumo:
The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.
Resumo:
Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Gestão de Informação
Resumo:
The aim of this retrospective study was to compare the clinical and radiographic results after TKA (PFC, DePuy), performed either by computer assisted navigation (CAS, Brainlab, Johnson&Johnson) or by conventional means. Material and methods: Between May and December 2006 we reviewed 36 conventional TKA performed between 2002 and 2003 (group A) and 37 navigated TKA performed between 2005 and 2006 (group B) by the same experienced surgeon. The mean age in group A was 74 years (range 62-90) and 73 (range 58-85) in group B with a similar age distribution. The preoperative mechanical axes in group A ranged from -13° varus to +13° valgus (mean absolute deviation 6.83°, SD 3.86), in group B from -13° to +16° (mean absolute deviation 5.35, SD 4.29). Patients with a previous tibial osteotomy or revision arthroplasty were excluded from the study. Examination was done by an experienced orthopedic resident independent of the surgeon. All patients had pre- and postoperative long standing radiographs. The IKSS and the WOMAC were utilized to determine the clinical outcome. Patient's degree of satisfaction was assessed on a visual analogous scale (VAS). Results: 32 of the 37 navigated TKAs (86,5%) showed a postoperative mechanical axis within the limits of 3 degrees of valgus or varus deviation compared to only 24 (66%) of the 36 standard TKAs. This difference was significant (p = 0.045). The mean absolute deviation from neutral axis was 3.00° (range -5° to +9°, SD: 1.75) in group A in comparison to 1.54° (range -5° to +4°, SD: 1.41) in group B with a highly significant difference (p = 0.000). Furthermore, both groups showed a significant postoperative improvement of their mean IKSS-values (group A: 89 preoperative to 169 postoperative, group B 88 to 176) without a significant difference between the two groups. Neither the WOMAC nor the patient's degree of satisfaction - as assessed by VAS - showed significant differences. Operation time was significantly higher in group B (mean 119.9 min.) than in group A (mean 99.6 min., p <0.000). Conclusion: Our study showed consistent significant improvement of postoperative frontal alignment in TKA by computer assisted navigation (CAS) compared to standard methods, even in the hands of a surgeon well experienced in standard TKA implantation. However, the follow-up time of this study was not long enough to judge differences in clinical outcome. Thus, the relevance of computer navigation for clinical outcome and survival of TKA remains to be proved in long term studies to justify the longer operation time. References 1 Stulberg SD. Clin Orth Rel Res. 2003;(416):177-84. 2 Chauhan SK. JBJS Br. 2004;86(3):372-7. 3 Bäthis H, et al. Orthopäde. 2006;35(10):1056-65.
Resumo:
Introduction: Coordination is a strategy chosen by the central nervous system to control the movements and maintain stability during gait. Coordinated multi-joint movements require a complex interaction between nervous outputs, biomechanical constraints, and pro-prioception. Quantitatively understanding and modeling gait coordination still remain a challenge. Surgeons lack a way to model and appreciate the coordination of patients before and after surgery of the lower limbs. Patients alter their gait patterns and their kinematic synergies when they walk faster or slower than normal speed to maintain their stability and minimize the energy cost of locomotion. The goal of this study was to provide a dynamical system approach to quantitatively describe human gait coordination and apply it to patients before and after total knee arthroplasty. Methods: A new method of quantitative analysis of interjoint coordination during gait was designed, providing a general model to capture the whole dynamics and showing the kinematic synergies at various walking speeds. The proposed model imposed a relationship among lower limb joint angles (hips and knees) to parameterize the dynamics of locomotion of each individual. An integration of different analysis tools such as Harmonic analysis, Principal Component Analysis, and Artificial Neural Network helped overcome high-dimensionality, temporal dependence, and non-linear relationships of the gait patterns. Ten patients were studied using an ambulatory gait device (Physilog®). Each participant was asked to perform two walking trials of 30m long at 3 different speeds and to complete an EQ-5D questionnaire, a WOMAC and Knee Society Score. Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. The outcomes of the eight patients undergoing total knee arthroplasty, recorded pre-operatively and post-operatively at 6 weeks, 3 months, 6 months and 1 year were compared to 2 age-matched healthy subjects. Results: The new method provided coordination scores at various walking speeds, ranged between 0 and 10. It determined the overall coordination of the lower limbs as well as the contribution of each joint to the total coordination. The difference between the pre-operative and post-operative coordination values were correlated with the improvements of the subjective outcome scores. Although the study group was small, the results showed a new way to objectively quantify gait coordination of patients undergoing total knee arthroplasty, using only portable body-fixed sensors. Conclusion: A new method for objective gait coordination analysis has been developed with very encouraging results regarding the objective outcome of lower limb surgery.