993 resultados para pressão intraocular
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Química - IQ
Resumo:
This work describes the development of an electro-mechanical micro-discharges device operating at ambient condition of pressure and temperature, capable to produce plasma jets for surface finishing. The discharges are produced through a needle shape electrode hollow cathode type by which flows the helium gas. The voltage applied on the electrode is provided for an AC/AC switching voltage converter of full-bridge topology. The converter is energized by a power line of 110/220 VAC, 60 Hz and gives a 1000 V peak-to-peak from 5 kHz to 40 kHz square waveform output. The output frequency is defined by a control signal provided by an external signal generator. The equipment setup includes output acquisition of voltage and current and a photo-detector for photo-electrical measurements, which allows an optical characterization of the plasma jet
Resumo:
In a market environment increasingly competitive, the companies need to control of this process accurately, avoiding rework or rejection of materials during industrialization. This can be achieved by defining procedure that assure the maintenance of the materials characteristics, as specified initially in the projects. This graduation work has the objective of defining the best heat treatment parameter of normalizing for Heads, part of a pressure vessel, formed in P275NH material. The methodology applied is based on the execution of a sequence of Heat Treatments, using different parameters. The process variables were the cooling velocity, the hold time and the hold temperature variation. As a result of this study, it is noticed that the mechanical properties of the materials are strongly influenced by the hold temperature variation and by the cooling velocity, both determined for the heat treatment cycle
Resumo:
This work describes the development of an electro-mechanical micro-discharges device operating at ambient condition of pressure and temperature, capable to produce plasma jets for surface finishing. The discharges are produced through a needle shape electrode hollow cathode type by which flows the helium gas. The voltage applied on the electrode is provided for an AC/AC switching voltage converter of full-bridge topology. The converter is energized by a power line of 110/220 VAC, 60 Hz and gives a 1000 V peak-to-peak from 5 kHz to 40 kHz square waveform output. The output frequency is defined by a control signal provided by an external signal generator. The equipment setup includes output acquisition of voltage and current and a photo-detector for photo-electrical measurements, which allows an optical characterization of the plasma jet
Resumo:
In a market environment increasingly competitive, the companies need to control of this process accurately, avoiding rework or rejection of materials during industrialization. This can be achieved by defining procedure that assure the maintenance of the materials characteristics, as specified initially in the projects. This graduation work has the objective of defining the best heat treatment parameter of normalizing for Heads, part of a pressure vessel, formed in P275NH material. The methodology applied is based on the execution of a sequence of Heat Treatments, using different parameters. The process variables were the cooling velocity, the hold time and the hold temperature variation. As a result of this study, it is noticed that the mechanical properties of the materials are strongly influenced by the hold temperature variation and by the cooling velocity, both determined for the heat treatment cycle
Resumo:
PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.
Resumo:
To describe a new method for iris fixation of intraocular lens in the absence of capsular support during penetrating keratoplasty. Its a new technique of iris fixation of intraocular lens without capsular support during penetrating keratoplasty. This technique is used in cases with a healthy iris and partial or total absence of capsular support during penetrating keratoplasty. Tied Out Open Sky is a technique easy to perform for iris fixation of intraocular lens during penetrating keratoplasty. The big advantage is being able to tie off the intraocular lens off the eye and fasten it securely.
Resumo:
Accurate alignment of a toric intraocular lens (IOL) is a requisite to achieving the intended reduction in astigmatism at the time of cataract surgery. However, it requires a reasonably clear view of the limbal vascular anatomy, which is sometimes altered by chemosis from a subconjunctival anesthetic injection or a hemorrhage. We describe a technique that can quickly restore vascular anatomy and facilitate toric IOL alignment.
Resumo:
PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes) received ultraviolet and blue light filter (yellow tinted) IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD]) investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens) difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens) under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.
Resumo:
FUNDAMENTO: Estudos têm demonstrado que a desnutrição pré/pós-natal leva a um maior risco de doenças não transmissíveis, como diabetes, hipertensão e obesidade na idade adulta. OBJETIVO: Determinar se os adolescentes com sobrepeso e desnutrição leve [escores-Z altura/idade (HAZ) na faixa de <-1 a > -2] têm pressão arterial mais elevada do que os indivíduos com sobrepeso e com estatura normal (HAZ > -1). MÉTODOS: Os participantes foram classificados como de baixa estatura leve ou de estatura normal, e estratificados de acordo com os percentis de massa corporal para a idade, como sobrepeso, peso normal ou abaixo do peso. As pressões arteriais sistólica (PAS) e diastólica (PAD) foram determinadas de acordo com as diretrizes e a gordura abdominal foi analisada por absorciometria de dupla emissão de raios-X. RESULTADOS: Indivíduos com baixa estatura leve e sobrepeso apresentaram valores mais elevados da PAD (p = 0,001) do que suas contrapartes de baixo peso (69,75 ± 12,03 e 54,46 ± 11,24 mmHg, respectivamente), mas semelhantes àqueles com IMC normal. Não foram encontradas diferenças nos valores de PAD em indivíduos normais, indivíduos com sobrepeso e com baixo peso entre os grupos de estatura normal. Foi encontrado um aumento na PAS (p = 0,01) entre os indivíduos com baixa estatura leve quando comparados os indivíduos com sobrepreso com suas contrapartes de baixo peso e IMC normal (114,70 ± 15,46, 97,38 ± 10,87 e 104,72 ± 12,24 mmHg, respectivamente). Embora não tenham sido observadas diferenças nas médias de PAS entre os grupos de baixa estatura leve e estatura normal, foi encontrado um intercepto significativo (p = 0,01), revelando maior PAS entre os indivíduos com baixa estatura leve. Houve correlação entre PAS e gordura abdominal (r = 0,42, ρ = 0,02) no grupo com baixa estatura leve. CONCLUSÃO: Indivíduos de baixa estatura leve com sobrepeso apresentaram maior PAS do que os de estatura normal e sobrepeso. Esses achados confirmam que a baixa estatura leve aumenta o risco futuro de hipertensão e essas alterações são evidentes em indivíduos jovens.