892 resultados para metallic surfaces


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chalcogenolate mediated Michael-aldol cascade reactions consists of a very efficient route to multi-functionalized gamma-hydroxichalcogenides. Although, when selenolates are employed, these gamma-hydroxichalcogenides can be readily converted into the corresponding Morita-Baylis-Hillman adducts by oxidative elimination of the selenium moiety. In this context, herein we present a complete study on the scope and limitations of this reaction. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have explored the effects of atmospheric environment on Kelvin force microscopy (KFM) measurements of potential difference between different regions of test polycrystalline diamond surfaces. The diamond films were deposited by microwave plasma-assisted chemical vapor deposition, which naturally produces hydrogen terminations on the surface of the films formed. Selected regions were patterned by electron-beam lithography and chemical terminations of oxygen or fluorine were created by exposure to an oxygen or fluorine plasma source. For KFM imaging, the samples were mounted in a hood with a constant flow of helium gas. Successive images were taken over a 5-h period showing the effect of the environment on KFM imaging. We conclude that the helium flow removes water molecules adsorbed on the surface of the samples, resulting in differences in surface potential between adjacent regions. The degree of water removal is different for surfaces with different terminations. The results highlight the importance of taking into account the atmospheric environment when carrying out KFM analysis. (C) 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new and simple criterion with which to quantitatively predict the glass forming ability (GFA) of metallic alloys is proposed. It was found that the critical cooling rate for glass formation (R-C) correlates well with a proper combination of two factors, the minimum topological instability (lambda(min)) and the Delta h parameter, which depends on the average work function difference (Delta phi) and the average electron density difference (Delta n(ws)(1/3)) among the constituent elements of the alloy. A correlation coefficient (R-2) of 0.76 was found between R-c and the new criterion for 68 alloys in 30 different metallic systems. The new criterion and the Uhlmann's approach were used to estimate the critical amorphous thickness (Z(C)) of alloys in the Cu-Zr system. The new criterion underestimated R-C in the Cu-Zr system, producing predicted Z(C) values larger than those observed experimentally. However, when considering a scale factor, a remarkable similarity was observed between the predicted and the experimental behavior of the GFA in the binary Cu-Zr. When using the same scale factor and performing the calculation for the ternary Zr-Cu-Al, good agreement was found between the predicted and the actual best GFA region, as well as between the expected and the observed critical amorphous thickness. (C) 2012 American Institute of Physics. [doi:10.1063/1.3676196]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dental implants have increased the use of titanium and titanium alloys in prosthetic applications. Whitening toothpastes with peroxides are available for patients with high aesthetic requirements, but the effect of whitening toothpastes on titanium surfaces is not yet known, although titanium is prone to fluoride ion attack. Thus, the aim of the present study was to compare Ti-5Ta alloy to cp Ti after toothbrushing with whitening and conventional toothpastes. Ti-5Ta (%wt) alloy was melted in an arc melting furnace and compared with cp Ti. Disks and toothbrush heads were embedded in PVC rings to be mounted onto a toothbrushing test apparatus. A total of 260,000 cycles were carried out at 250 cycles/minute under a load of 5 N on samples immersed in toothpaste slurries. Surface roughness and Vickers microhardness were evaluated before and after toothbrushing. One sample of each material/toothpaste was analyzed by Scanning Electron Microscopy (SEM) and compared with a sample that had not been submitted to toothbrushing. Surface roughness increased significantly after toothbrushing, but no differences were noted after toothbrushing with different toothpastes. Toothbrushing did not significantly affect sample microhardness. The results suggest that toothpastes that contain and those that do not contain peroxides in their composition have different effects on cp Ti and Ti-5Ta surfaces. Although no significant difference was noted in the microhardness and roughness of the surfaces brushed with different toothpastes, both toothpastes increased roughness after toothbrushing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The practice of running has consistently increased worldwide, and with it, related lower limb injuries. The type of running surface has been associated with running injury etiology, in addition other factors, such as the relationship between the amount and intensity of training. There is still controversy in the literature regarding the biomechanical effects of different types of running surfaces on foot-floor interaction. The aim of this study was to investigate the influence of running on asphalt, concrete, natural grass, and rubber on in-shoe pressure patterns in adult recreational runners. Forty-seven adult recreational runners ran twice for 40 m on all four different surfaces at 12 +/- 5% km . h(-1). Peak pressure, pressure-time integral, and contact time were recorded by Pedar X insoles. Asphalt and concrete were similar for all plantar variables and pressure zones. Running on grass produced peak pressures 9.3% to 16.6% lower (P < 0.001) than the other surfaces in the rearfoot and 4.7% to 12.3% (P < 0.05) lower in the forefoot. The contact time on rubber was greater than on concrete for the rearfoot and midfoot. The behaviour of rubber was similar to that obtained for the rigid surfaces - concrete and asphalt - possibly because of its time of usage (five years). Running on natural grass attenuates in-shoe plantar pressures in recreational runners. If a runner controls the amount and intensity of practice, running on grass may reduce the total stress on the musculoskeletal system compared with the total musculoskeletal stress when running on more rigid surfaces, such as asphalt and concrete.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Knowing the microbiota that colonizes orthodontic appliances is important for planning strategies and implementing specific preventive measures during treatment. The purpose of this clinical trial was to evaluate in vivo the contamination of metallic orthodontic brackets with 40 DNA probes for different bacterial species by using the checkerboard DNA-DNA hybridization (CDDH) technique. Methods: Eighteen patients, 11 to 29 years of age having fixed orthodontic treatment, were enrolled in the study. Each subject had 2 new metallic brackets bonded to different premolars in a randomized manner. After 30 days, the brackets were removed and processed for analysis by CDDH. Data on bacterial contamination were analyzed descriptively and with the Kruskal-Wallis and Dunn post tests (alpha = 0.05). Forty microbial species (cariogenic microorganisms, bacteria of the purple, yellow, green, orange complexes, "red complex + Treponema socranskii," and the cluster of Actinomyces) were assessed. Results: Most bacterial species were present in all subjects, except for Streptococcus constellatus, Campylobacter rectus, Tannerella forsythia, T socranskii, and Lactobacillus acidophillus (94.4%), Propionibacterium acnes I and Eubacterium nodatum (88.9%), and Treponema denticola (77.8%). Among the cariogenic microorganisms, Streptococcus mutans and Streptococcus sobrinus were found in larger numbers than L acidophillus and Lactobacillus casei (P < 0.001). The periodontal pathogens of the orange complex were detected in larger numbers than those of the "red complex + T socranskii" (P < 0.0001). Among the bacteria not associated with specific pathologies, Veillonella parvula (purple complex) was the most frequently detected strain (P < 0.0001). The numbers of yellow and green complex bacteria and the cluster of Actinomyces were similar (P > 0.05). Conclusions: Metallic brackets in use for 1 month were multi-colonized by several bacterial species, including cariogenic microorganisms and periodontal pathogens, reinforcing the need for meticulous oral hygiene and additional preventive measures to maintain oral health in orthodontic patients. (Am J Orthod Dentofacial Orthop 2012;141:24-9)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corrosion is a relevant issue regarding the problem of biodiesel compatibility with polymers and metals. This work aims to evaluate the influence of the natural light incidence and temperature in the corrosion rate of brass and copper immersed in commercial biodiesel as well as biodiesel degradation after the contact with metallic ions. The characterization of corrosion behavior was performed by weight loss measurements according to ASTM G1 and ASTM G31. The experiments according to ASTM G1 were performed at room temperature in light presence and absence. Experiments were also conducted at 55 degrees C in order to compare with ASTM G31 that is also performed at that temperature. The biodiesel degradation was characterized by water content, oxidation stability, viscosity as well as XRF, IR and Raman spectroscopies. The results of ASTM G1 tests showed that the thickness loss for both metals determined at room temperature is slightly higher when there is light incidence and these values significantly decrease for the highest temperature. The results of ASTM G31 tests indicated that air bubbling along with higher temperature affects mostly immersed samples. Biodiesel in contact with metals shows significant degradation in its properties as evidenced by increasing water content, higher viscosity and lower oxidation stability. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this randomized clinical study was to evaluate the presence of the periodontal pathogen Aggregatibacter actinomycetemcomitans on metallic brackets and the effectiveness of a 0.12% chlorhexidine digluconate mouthwash in inhibiting this microorganism. Methods: The study involved 35 patients of both sexes having orthodontic treatment with fixed appliances between the ages of 14 and 22 years, randomized into 2 groups: experimental (n = 17) and control (n = 18). Two new metallic brackets were placed on the patients' premolars, and the subjects rinsed with a solution of 0.12% chlorhexidine digluconate or a placebo solution twice a week for 30 days. After that, the brackets were removed and underwent microbiologic analysis with the checkerboard DNA-DNA hybridization technique. Data were analyzed by using the Student t, Fisher exact, and Mann-Whitney tests at the significance level of 5%. Results: The results showed that A actinomycetemcomitans was present in all brackets from the subjects in the control group vs 83% of the subjects who rinsed with chlorhexidine digluconate (P<0.0001). There were also significantly lower levels of this species in the chlorhexidine digluconate group compared with the control group (P = 0.0003). Conclusions: We concluded that 0.12% chlorhexidine digluconate rinsing, twice a week for 30 days during orthodontic treatment, is effective in reducing the presence and levels of A actinomycetemcomitans on metallic brackets. (Am J Orthod Dentofacial Orthop 2012;142:481-6)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we compare the simple singularities of germs from R-2 to R-p with multiplicity 2 or 3 with the singularities appearing in the set of 2-ruled surfaces. We also study the topological type of all finitely determined singularities by studying generic projections of these singularities in R-3. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We review the previous literature and our recent work on first-principles studies of Cu3Au(100) and (111) surfaces, with focus on the segregation of atomic species to the surface at pristine conditions and in the presence of oxygen. In particular, the combined use of experimental and theoretical tools to achieve chemical identification at an atomic level of the surface species is emphasized and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate the effect of Si addition on a nanometer-scale roughness Ca and P implant surfaces in a canine tibia model by biomechanical and histomorphometric evaluations. Material and methods: The implant surfaces comprised a resorbable media CaP microblasted (control) and a CaP resorbable media + silica-boost microblasted (experimental) surfaces. Surfaces were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and optical interferometry (IFM) down to the nanometric level. The animal model involved the bilateral placement of control (n = 24) and experimental surface (n = 24) implants along the proximal tibiae of six dogs, remaining in vivo for 2 or 4 weeks. After euthanization, half of the specimens were torquedto- interface failure, and the other half was subjected to histomorphologic and bone-to-implant contact (BIC) evaluation. Torque and BIC statistical evaluation was performed by the Friedman test at 95% level of significance, and comparisons between groups was performed by the Dunn test. Results: IFM and SEM observations depicted comparable roughness parameters for both implant surfaces on the micrometer and nanometer scales. XPS analysis revealed similar chemical composition, except for the addition of Si on the experimental group. Torque-to-interface failure and BIC mean values showed no significant differences (P = 0.25 and 0.51, respectively) at both 2- and 4-week evaluation points for experimental and control groups. Early bone healing histomorphologic events were similar between groups. Conclusions: The experimental surface resulted in not significantly different biomechanical fixation and BIC relative to control. Both surfaces were biocompatible and osseoconductive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Several implant surfaces are being developed, some in the nanoscale level. In this study, two different surfaces had their early healing properties compared in context of circumferential defects of various widths. Material and methods Six dogs had the mandibular premolars extracted. After 8weeks, four implants were placed equicrestally in each side. One acted as control, while the others were inserted into sites with circumferential defects of 1.0, 1.5 and 2.0mm wide and 5mm deep. A nano-modified surface was used on one side and a micro-rough on the other. Bone markers were administered on the third day after implant placement and then after 1, 2, 4weeks to investigate the bone formation dynamic through fluorescence analysis. Ground sections were prepared from 8-week healing biopsies and histomorphometry was performed. Results The fluorescence evaluation of the early healing showed numerically better results for the nano-modified group; however this trend was not followed by the histomorphometric evaluation. A non-significant numerical superiority of the micro-rough group was observed in terms of vertical bone apposition, defect bone fill, bone-to-implant contact and bone density. In the intra-group analysis, the wider defects showed the worse results while the control sites showed the best results for the different parameters, but without statistical relevance. Conclusion Both surfaces may lead to complete fill of circumferential defects, but the gap width has to be considered as a challenge. The nano-scale modification was beneficial in the early stages of bone healing, but the micro-rough surface showed numerical better outcomes at the 8-week final period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bacterial adhesion to inert surfaces is a complex process influenced by environmental conditions. In this work, the influence of growth medium and temperature on the adhesion of Pseudomonas aeruginosa, Serratia marcescens, Staphylococcus aureus, Micrococcus luteus and Listeria monocytogenes to polystyrene surfaces was studied. Most bacteria demonstrated the highest adhesion when cultured in TSYEA, except S. marcescens, which showed to be positively influenced by the pigment production, favored in poor nutrient media (lactose and peptone agar). P. aeruginosa adhesion to polystyrene increased at low temperatures whatever the medium used. The culture medium influenced the surface properties of the bacteria as assessed by the MATS test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The competition between confinement potential fluctuations and band-gap renormalization (BGR) in GaAs/AlxGa1-xAs quantum wells grown on [1 0 0] and [3 1 1]A GaAs substrates is evaluated. The results clearly demonstrate the coexistence of the band-tail states filling related to potential fluctuations and the band-gap renormalization caused by an increase in the density of photogenerated carriers during the photoluminescence (PL) experiments. Both phenomena have strong influence on temperature dependence of the PL-peak energy (E-PL(T)). As the photon density increases, the E-PL can shift to either higher or lower energies, depending on the sample temperature. The temperature at which the displacement changes from a blueshift to a redshift is governed by the magnitude of the potential fluctuations and by the variation of BGR with excitation density. A simple band-tail model with a Gaussian-like distribution of the density of state was used to describe the competition between the band-tail filling and the BGR effects on E-PL(T). (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The objective of the study was to evaluate the ability of large-volume cone-beam computed tomography (CBCT) to detect horizontal root fracture and to test the influence of a metallic post. Methods: Through the examination of 40 teeth by large-volume CBCT (20-cm height and 15-cm diameter cylinder) at 0.2-mm voxel resolution, 2 observers analyzed the samples for the presence and localization of horizontal root fracture. Results: The values of accuracy in the groups that had no metallic post ranged from 33%-68%, whereas for the samples with the metallic post, values showed a wide variation (38%-83%). Intraobserver agreement showed no statistically significant difference between the groups with/without metallic post; both ranged from very weak to weak (kappa, 0.09-0.369). Conclusions: The low accuracy and low intraobserver and interobserver agreement reflect the difficulty in performing an adequate diagnosis of horizontal root fractures through a large-volume CBCT by using a small voxel reconstruction. (J Endod 2012;38:856-859)