999 resultados para industrial area
Resumo:
This paper presents a low-cost scaled model of a silo for drying and airing cereal grains. It allows the control and monitor of several parameters associated to the silo's operation, through a remote accessible infrastructure. The scaled model consists of a 2.50 m wide × 2.10 m long plant with all control and monitor capacities provided by micro-Web servers. An application running on the micro-Web servers enables storing all parameters in a data basis for later analysis. The implemented model aims to support a remote experimentation facility for technological education, research-oriented tutorials, and industrial applications. Given the low-cost requirement, this remote facility can be easily replicated in other institutions to support a network of remote labs, which encompasses the concurrent access of several users (e.g. students).
Resumo:
Portugal, as well as the Mediterranean basin, is favorable to the occurrence of forest fires. In this work a statistical analysis was carried out based on the official information, considering the forest fires occurrences and the corresponding burned area for each of the districts of the mainland Portugal, between 1996 and 2010. Concerning to the forest fires occurrence it was possible to identify three main regions in mainland Portugal, while the burned area can be characterized in two main regions. Associations between districts and years are different in the two approaches. The results obtained provide a synthetic analysis of the phenomenon of forest fires in continental Portugal, based on all the official information available to date.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova Lisboa para a obtenção de grau de Mestre em Bioenergia
Resumo:
No âmbito da Unidade Curricular Dissertação, inserida no segundo ano do Mestrado em Engenharia Mecânica – Gestão Industrial do Instituto Superior de Engenharia do Porto, foi proposto um projecto que está a ser desenvolvido pela equipa de Engenharia e Gestão Industrial, da unidade de negócios AMT, intitulado por: “Projecto Índia – Desenvolvimento da nova unidade fabril” Este projecto tem como principal objectivo o desenvolvimento de uma fábrica de excelência na Índia de fabricação de componentes de média tensão, isto é, com processos logísticos bem definidos e com linhas de produção o mais automatizadas possivel. Esta nova fábrica de raiz, vai ser gerida e decalcada do modelo atualmente existe na fábrica da EFACEC de componentes de média tensão existente em Portugal. Numa primeira fase do desenvolvimento do projecto, foi seleccionado um edifício com cerca de 1600m2 em Nashik, uma localidade a cerca de 171 Km de Mumbai, onde se encontram 80% dos fornecedores da EFACEC. Foram identificados os produtos a serem fabricados e quantificada a respectiva procura anual. Foi efectuado o balanceamento de cada uma das linhas e desenhado o layout. Neste layout contemplou-se as áreas de produção, laboratório, gabinetes de chefes de equipa, expedição, recepção e armazém. Após a definição das áreas de montagem de cada produto, iniciou-se a concepção das linhas de produção, sobretudo automáticas, com a definição da cadência de produção. A linha de fabricação que é especialmente detalhada neste documento é a linha de montagem dos comandos CI. Este é o produto com mais procura. Foi também definido o processo logístico do fluxo interno da fábrica. Nas linhas de produção foi implementado o sistema de controlo de fluxo baseado em cartões Kanban e no armazém criou-se um novo conceito de controlo e localização de produtos, o “Aquiles”. O Aquiles permite automaticamente e através da leitura de código de barras, indexar os artigos nas estantes. Cada artigo e cada estante e/ou localização estão codificados e no momento de recepção de material o código do artigo é associado ao código da estante. No âmbito de explorar todas as soluções possíveis para a um melhor desenvolvimento desta nova fábrica foram abordados temas como “JIT”, “Pull Flow”, “Kanban”, “Takttime”.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Manutenção
Resumo:
Trabalho de projecto para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Estruturas
Resumo:
The interrelation between schistosomiasis and the retinol blood levels was studied in a double blind method, by comparing the serum vitamin A of the infected and non-infected group of an endemic area of Schistosoma mansoni infection. The infected group was characterized by 106 parasitized persons in the intestinal and hepatointestinal forms, who eliminated less than 500 eggs/gram of feces (Modified Kato's method); the non-infected group was characterized by 112 inhabitants of this endemic area without eggs in the stools and presenting negative intradermal reactions, and absence of previous specific treatment. The blood levels of retinol was determinated using trifluoracetic acid method, regarding the normal levels > 20,0mg/100ml. The results of this study point out the absence of correlation between S. mansoni infection and blood levels of vitamin A.
Resumo:
Parasitological examinations were carried out during April to August, 1987, with 187 out-patients of the IMIP hospital, located in the center of Recife City, and 464 inhabitants of several villages around Cabo City, 50 Km southeast of Recife, Pernambuco, Brazil. Approximately 71% of the IMIP patients and 92% of the Cabo inhabitants were infected with at least one species of intestinal parasite. There was minimum difference in the prevalence rate of Trichuris trichiura between two areas, whereas the prevalence rates of Ascaris lumbricoides, hookworms, Strongyloides stercoralis, Schistosoma mansoni and Entamoeba histolytica were higher in the inhabitants of the Cabo City area. Only Giardia lamblia was more prevalent in the out-patients of IMIP hospital. Test tube cultivation revealed that the prevalence rate of Necator americanus in both areas was much higher than that of Ancylostoma duodenale , and also that the prevalence rate of S. stercoralis of the IMIP patients and Cabo inhabitants were 4.5% and 9.6%, respectively. Six hundred and fifteen sera were serologically examined for amoebiasis by the gel diffusion precipitation test (GDP) and enzyme linked immunosorbent assay (ELISA) using the antigen prepared from axenically cultured trophozoite of E. histolytica (strain HM-ITMSS). No positive reaction was observed in all of the sera as examined by GDP, while 32 out of 615 sera were positive on ELISA.
Resumo:
Mestrado em Engenharia Mecânica – Gestão Industrial
Resumo:
IEEE International Symposium on Circuits and Systems, pp. 220 – 223, Seattle, EUA
Resumo:
The prescribed fire is a technique that is often used, it has several advantages. Pedological and hydropedological techniques were tested to assess the prescribed fire changes may cause in soils. This work was performed in Tresminas area (Vila Pouca de Aguiar, Northern Portugal), during February and March 2011. In the present study we applied several techniques. For the field sampling was followed the ISO 10381-1[1], ISO 10381-2[2], and FAO rules [3], as well as were used a grid with 17 points for measuring the soil parameters. During the fire, we have tried to check, with the assistance of the Portuguese Forestry Authority, some important parameters such as, the propagation speed, the size of the flame front and the intensity of energy emitted per unit area. Before the fire, was collected carefully soil disturbed and undisturbed samples for laboratory analysis, and measured soil water content; we also have placed four sets of thermocouples for measuring soil temperature. After the fire, were collected the thermocouples and new soil samples; the water content were measured in the soil and collected ashes. In the laboratory, after preparing and sieving the samples, were determined the soil particle size. The soil pH and electrical conductivity in water was also determined. The total carbon (TC) and inorganic carbon (IC)[4] was measured by a Shimadzu TOC-Vcsn. The water content in soil has not varied significantly before and after the fire, as well as soil pH and soil electrical conductivity. The TC and IC did not change, which was expected, since the fire not overcome the 200° C. Through the various parameters, we determined that the prescribed fire didn’t affect the soil. The low temperature of the fire and its rapid implementation that lead to the possible adverse effects caused by the wild fire didn’t occurred.
Resumo:
Dissertação apresentada para a obtenção do Grau de Mestre em Engenharia Civil, Perfil de Construção, pela Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Civil – Reabilitação de Edifícios
Resumo:
Certain materials used and produced in a wide range of non-nuclear industries contain enhanced activity concentrations of natural radionuclides. In particular, electricity production from coal is one of the major sources of increased exposure to man from enhanced naturally occurring materials. Over the past decades there has been some discussion about the elevated natural background radiation in the area near coal-fired power plants due to high uranium and thorium content present in coal. This work describes the methodology developed to assess the radiological impact due to natural radiation background increasing levels, potentially originated by a coal-fired power plant’s operation. Gamma radiation measurements have been done with two different instruments: a scintillometer (SPP2 NF, Saphymo) and a gamma ray spectrometer with energy discrimination (Falcon 5000, Canberra). A total of 40 relevant sampling points were established at locations within 20 km from the power plant: 15 urban and 25 suburban measured stations. The highest values were measured at the sampling points near to the power plant and those located in the area within the 6 and 20 km from the stacks. This may be explained by the presence of a huge coal pile (1.3 million tons) located near the stacks contributing to the dispersion of unburned coal and, on the other hand, the height of the stacks (225 m) which may influence ash’s dispersion up to a distance of 20 km. In situ gamma radiation measurements with energy discrimination identified natural emitting nuclides as well as their decay products (212Pb, 214Pb, 226Ra 232Th, 228Ac, 234Th 234Pa, 235U, etc.). This work has been primarily done to in order to assess the impact of a coal-fired power plant operation on the background radiation level in the surrounding area. According to the results, an increase or at least an influence has been identified both qualitatively and quantitatively.
Resumo:
The industrial activity is inevitably associated with a certain degradation of the environmental quality, because is not possible to guarantee that a manufacturing process can be totally innocuous. The eco-efficiency concept is globally accepted as a philosophy of entreprise management, that encourages the companies to become more competitive, innovative and environmentally responsible by promoting the link between its companies objectives for excellence and its objectives of environmental excellence issues. This link imposes the creation of an organizational methodology where the performance of the company is concordant with the sustainable development. The main propose of this project is to apply the concept of eco-efficiency to the particular case of the metallurgical and metal workshop industries through the development of the particular indicators needed and to produce a manual of procedures for implementation of the accurate solution.