955 resultados para analytical study


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Darunavir, a protease inhibitor used in the treatment of HIV infection, presents few methods for its determination in pharmaceuticals. Infrared (IR) spectroscopy offers the possibility of obtaining spectra relatively quickly, providing interesting information, analytically, qualitatively or quantitatively. Capillary electrophoresis (CE) performs separations of high efficiency in shorter time with reagents and samples in small quantity. These two methods are cost-benefitted when we evaluate the green level and the cost of analysis. Faster and cheaper methods without generating organic waste by IR and CE for the quantification of darunavir were developed and validated, focusing socioeconomic impact of analytical decisions. If the cost of acquisition, maintenance, production, analysis and conditioning of drugs and pharmaceuticals is high, consequently the price of this product in the market will be higher and it cannot be accessible to the patient. Treatment failure not only affects the quality of life of patients, but also contributes significantly to the economic burden of the health system. In this context there is a tool called Analysis of the Life Cycle, which comes to make us think in a multidimensional way focusing the whole, the parts and especially the interaction among the parts of a system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Antimicrobials have unquestionable importance in the control of many diseases; however the constant concern with evolution of resistant microorganisms is increasing. The ertapenem sodium is a β-lactam antibiotic of the carbapenem class, which it has a broader activity spectrum than most other β-lactam antimicrobials, and is more resistant to the enzyme β-lactamase, which is the main mechanism of resistance of many bacteria. The progress of microbial resistance to existing antibiotics is alarming. Thus we need to preserve antimicrobials that still have activity against these pathogens. In this context, the quality control has a key role to ensure the correct dosage, by contributing preventively to minimize the development of resistant microorganisms. Study of the physicochemical characteristics of the drug and the quantification of the content of active substance are of fundamental importance for the pharmaceutical industry to ensure the quality of the product sold. This work presents a literature survey of existing methods for ertapenem sodium quantification which was performed. Ertapenem sodium can be analyzed by many types of assays; however the HPLC is the most used method. This review will examine the published analytical methods reported for determination of ertapenem sodium, in biological fluids and formulations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Considering the importance of spatial issues in transport planning, the main objective of this study was to analyze the results obtained from different approaches of spatial regression models. In the case of spatial autocorrelation, spatial dependence patterns should be incorporated in the models, since that dependence may affect the predictive power of these models. The results obtained with the spatial regression models were also compared with the results of a multiple linear regression model that is typically used in trips generation estimations. The findings support the hypothesis that the inclusion of spatial effects in regression models is important, since the best results were obtained with alternative models (spatial regression models or the ones with spatial variables included). This was observed in a case study carried out in the city of Porto Alegre, in the state of Rio Grande do Sul, Brazil, in the stages of specification and calibration of the models, with two distinct datasets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is a study on corporate communication and the ability to innovate in small businesses. The guiding question seeks to respond whether organizational communication is able to make progress and / or support innovation in micro and small companies, and the main objective is to analyze the relationship between innovation and organizational communication. It was applied the case study method and document research for interpreting a diagnosis instru- ment called “Innovation Radar” in a small business company located in the countryside of São Paulo state. The diagnosis is made based on assessment dimensions aimed at checking the maturity and the degree of innovation in micro and small companies. By evaluating these di- mensions it was possible to build analytical frameworks and highlight the influence of corporate communication in promoting innovation. The results indicate that every dimension of the “In- novation Radar” can improve their performance by means of corporate communication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study evaluated the main physical and chemical characteristics of Syrah grapes, coming from the tropical region of São Francisco river valley, harvested at different times and their relationship with analytical characteristics of resulting wines. Grapes came from the first half of 2009 harvest, collected at Casa Nova - Bahia, a semi-arid and hot region, comprising an interval from 84 days after pruning (84 dap) to the beginning of grape over-ripening, 133 days after pruning (133 dap). Harvests at 84, 91, 98, 105, 112, 119, 126 and 133 dap, were analyzed for pH, soluble solids and acidity in grapes, which were then processed for wine production. Maximum sugar/acidity ratio (s/a = 56) were observed in grapes harvested between 126 and 133 dap, coincided with the highest concentration of anthocyanins (851 mg L-1 ) and total tannins (2.6 g L-1 ) in the resulting wines, indicating that grapes collected between 126 and 133 dap showed the best potential for winemaking in the tropical climate of São Francisco river valley. This result was confirmed by the analytical characterization of wines, that, between 126 and 133 dap, showed 12.8% alcohol, 31 g L-1 dry extract, 5.6 g L-1 ashes and a TPI of 58, using only one pumping per day, for 5 days maceration. Syrah grapes considered in the present work presented a good evolution of maturation, and grapes harvested between 126 and 133 days after pruning, showed the best oenological potential for the development of red wine. The use of pH and soluble solids appeared useful parameters in the estimation of maturation degree and quality potential of grapes for winemaking.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Corrosion research in steels is one of the areas in which Mossbauer spectroscopy has become a required analytical technique, since it is a powerful tool for both identifying and quantifying distinctive phases (which contain Fe) with accuracy. In this manuscript, this technique was used to the study of corrosion resistance of plasma nitrided AISI 316L samples in the presence of chloride anions. Plasma nitriding has been carried out using dc glow-discharge, nitriding treatments, in medium of 80 vol.% H-2 and 20 vol.% N-2, at 673 K, and at different time intervals: 2, 4, and 7 h. Treated samples were characterized by means of phase composition and morphological analysis, and electrochemical tests in NaCl aerated solution in order to investigate the influence of treatment time on the microstructure and the corrosion resistance, proved by conversion electron Mossbauer spectroscopy (CEMS), glancing angle X-ray diffraction (GAXRD), scanning electron microscopy (SEM) and potentiodynamic polarization. A modified layer of about 8 gin was observed for all the nitrided samples, independently of the nitriding time. A metastable phase, S phase or gamma(N), was produced. It seems to be correlated with gamma`-Fe-4 N phase. If the gamma(N) fraction decreases, the gamma` fraction increases. The gamma(N) magnetic nature was analyzed. When the nitriding time increases, the results indicate that there is a significant reduction in the relative fraction of the magnetic gamma(N) (in) phase. In contrast, the paramagnetic gamma(N) (p) phase increases. The GAXRD analysis confirms the Mossbauer results, and it also indicates CrN traces for the sample nitrided for 7 h. Corrosion results demonstrate that time in the plasma nitriding treatment plays an important role for the corrosion resistance. The sample treated for 4 h showed the best result of corrosion resistance. It seems that the epsilon/gamma` fraction ratio plays an important role in thin corrosion resistance since this sample shows the maximum value for this ratio. (c) 2008 Published by Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When there is a failure on the external sheath of a flexible pipe, a high value of hydrostatic pressure is transferred to its internal plastic layer and consequently to its interlocked carcass, leading to the possibility of collapse. The design of a flexible pipe must predict the maximum value of external pressure the carcass layer can be subjected to without collapse. This value depends on the initial ovalization due to manufacturing tolerances. To study that problem, two numerical finite element models were developed to simulate the behavior of the carcass subjected to external pressure, including the plastic behavior of the materials. The first one is a full 3D model and the second one is a 3D ring model, both composed by solid elements. An interesting conclusion is that both the models provide the same results. An analytical model using an equivalent thickness approach for the carcass layer was also constructed. A good correlation between analytical and numerical models was achieved for pre-collapse behavior but the collapse pressure value and post-collapse behavior were not well predicted by the analytical model. [DOI: 10.1115/1.4005185]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

DEVELOPMENT AND VALIDATION OF AN ANALYTICAL METHOD FOR QUANTITATION OF THE DRUG BEVACIZUMAB BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY. In this study, an analytical method was developed and validated for quantitation of the drug bevacizumab (Avastin (R)) by high performance liquid chromatography (HPLC). The HPLC column was a BioSuite 250 (R) HR SEC, 300 x 7.8 mm x 5 mu m (Waters, USA). The mobile phase consisted of phosphate buffered saline (PBS). The results revealed that the method was specific, precise. accurate, robust and linear (r(2) = 0.998) from 5 to 75 mu g mL(-1). Therefore, this method can be used in drug release studies or in quality control ampoules of the drug.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study, a fast, sensitive and robust method to quantify dextromethorphan, dextrorphan and doxylamine in human plasma using deuterated internal standards (IS) is described. The analytes and the IS were extracted from plasma by a liquid-liquid extraction (LLE) using diethyl-ether/hexane (80/20, v/v). Extracted samples were analyzed by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Chromatographic separation was performed by pumping the mobile phase (acetonitrile/water/formic acid (90/9/1, v/v/v) during 4.0 min at a flow-rate of 1.5 mL min(-1) into a Phenomenex Gemini (R) C18, 5 mu m analytical column (150 x 4.6 mm id.). The calibration curve was linear over the range from 0.2 to 200 ng mL(-1) for dextromethorphan and doxylamine and 0.05 to 10 ng mL(-1) for dextrorphan. The intra-batch precision and accuracy (%CV) of the method ranged from 2.5 to 9.5%, and 88.9 to 105.1%, respectively. Method inter-batch precision (%CV) and accuracy ranged from 6.7 to 10.3%, and 92.2 to 107.1%, respectively. The run-time was for 4 min. The analytical procedure herein described was used to assess the pharmacokinetics of dextromethorphan, dextrorphan and doxylamine in healthy volunteers after a single oral dose of a formulation containing 30 mg of dextromethorphan hydrobromide and 12.5 mg of doxylamine succinate. The method has high sensitivity, specificity and allows high throughput analysis required for a pharmacokinetic study. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sensitive, selective, and reproducible in-tube solid-phase microextraction and liquid chromatographic (in-tube SPME/LC-UV) method for determination of lidocaine and its metabolite monoethylglycinexylidide (MEGX) in human plasma has been developed, validated, and further applied to pharmacokinetic study in pregnant women with gestational diabetes mellitus (GDM) subjected to epidural anesthesia. Important factors in the optimization of in-tube SPME performance are discussed, including the draw/eject sample volume, draw/eject cycle number, draw/eject flow rate, sample pH, and influence of plasma proteins. The limits of quantification of the in-tube SPME/LC method were 50 ng/mL for both metabolite and lidocaine. The interday and intraday precision had coefficients of variation lower than 8%, and accuracy ranged from 95 to 117%. The response of the in-tube SPME/LC method for analytes was linear over a dynamic range from 50 to 5000 ng/mL, with correlation coefficients higher than 0.9976. The developed in-tube SPME/LC method was successfully used to analyze lidocaine and its metabolite in plasma samples from pregnant women with GDM subjected to epidural anesthesia for pharmacokinetic study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The hermit crab Clibanarius vittatus is a typical organism from intertidal regions being considered as a good bioindicator of tributyltin presence at these environments. Thus this study presents the analytical performance and validation method for TBT quantification in tissues of C. vittatus by gas chromatography with pulsed flame photometric detector (GC-PFPD) after extraction with an apolar solvent (toluene) and Grignard derivatization. The limits of detection of the method (LOD) were 2.0 and 2.8 ng g(-1) for TBT and DBT (dibutyltin), respectively, and its limits of quantification (LOQ) were 6.6 and 8.9 ng g(-1) for TBT and DBT, respectively. The method was applied to samples from Santos Estuary, Sao Paulo State, Brazil. TBT and DBT concentrations ranged from 26.7 to 175.0 ng g(-1) and from 46.2 to 156.0 ng g(-1), respectively. These concentrations are worrisome since toxic effects (such as endocrine disruption) have been reported for other organisms even under lower levels of registred at this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The installation of induction distributed generators should be preceded by a careful study in order to determine if the point of common coupling is suitable for transmission of the generated power, keeping acceptable power quality and system stability. In this sense, this paper presents a simple analytical formulation that allows a fast and comprehensive evaluation of the maximum power delivered by the induction generator, without losing voltage stability. Moreover, this formulation can be used to identify voltage stability issues that limit the generator output power. All the formulation is developed by using the equivalent circuit of squirrel-cage induction machine. Simulation results are used to validate the method, which enables the approach to be used as a guide to reduce the simulation efforts necessary to assess the maximum output power and voltage stability of induction generators. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrochemical lead analyses of gunshot residues (GSRs) were performed using an acidic solution with a bare gold microelectrode in the presence of chloride ions. GSRs from four different guns (0.38 in. revolver, 12 caliber pump-action shotgun, 0.38 repeating rifle, and a 0.22 caliber semi-automatic rifle) and six different types of ammunition (CleanRange (R), normal, semi-jacketed, especial 24g (R), 3T (R), CBC (R), and Eley (R)) were analyzed. Results obtained with the proposed methodology were compared with those from an atomic absorption spectrometry analysis, and a paired Student's t-test indicated that there was no significant difference between them at the 95% confidence level. With this methodology, a detection limit of 1.7 nmol L-1 (3 sigma/slope), a linear range between 10 and 100 nmol L-1, and a relative standard deviation of 2.5% from 10 measurements were obtained. (C) 2011 Elsevier B.V. All rights reserved.