861 resultados para Voluntary Termination in Restaurants: An Exploratory Determination of Causes


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The feasibility of using internal standardization (IS) to correct for interferences in hydride generation with in situ trapping in graphite furnace was evaluated. Arsenic was chosen as internal standard for Sb determination and Ir was used as permanent modifier. Fluctuations in the main parameters that affect the analytical results were minimized by IS and an effective contribution was verified in the studies of liquid phase interferences. Cobalt and Ni2+ were selected to illustrate the potential use of IS on the correction of interference by transition metals. The application of IS allows the Sb determination in samples containing up to 20-fold higher concentration of the Co2+ and Ni2+ when compared to the procedure without IS. The relative standard deviation of measurements varied from 0.3% to 0.7% and from 1.1% to 3.2% with and without IS, respectively. Recoveries within 92% and 107% of spiked aqueous solution containing Sb(III) and Sb(V) were found. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An on-line dialysis flow system coupled to inductively coupled plasma mass spectrometry to determine trace elements in serum samples by isotope dilution is presented. Isotope dilution was performed on samples incubated with enriched Cu-65, Zn-66, Se-77 and Pb-206 for 24 h at 36degreesC prior to dialysis to quantified total element concentrations. The sample and acceptor solutions flowed through the dialysis unit with cellophane membrane placed in between the compartments. The serum sample (1 mL) was left to recycle in a closed path while the acceptor solution was continuously pumped along the dialyzer channel and through a cationic AG50W X-8 resin column. After 10 min, around 70% of Na, K and Cl migrate from the sample. Three replicate injections of 0.1 mL were performed for the clean sample after each separation step. The on-line coupling of the dialyzer to ICP-MS allowed isotope dilution for total element determination either in the cleaned sample or by eluting the cations retained in the resin to be carried out. Results demonstrated no matrix effects from alkaline elements or spectral interference from ArNa+ on Cu-63, ArCl+ on Se-77 and (SO2+)-S-34 on Zn-66. The precision of isotope ratio measurements for Cu and Zn was around 1% and for Se and Pb was around 2.5%. The values found for the reference serum sample IMEP-17 were in good agreement with the certified values for Cu, Zn and Se.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and efficient method for the simultaneous gas chromatographic determination of ten organochlorine pesticides (alpha-HCH, beta-HCH, gamma-HCH, p,p'-DDT, o,p'-DDT, p,p'-DDD, p,p'-DDE, aldrin, endrin, and dieldrin) and six congeners of PCBs (PCB 28, 52, 118, 138, 153, and 180) in municipal solid waste compost is described. The procedure involves a solid-phase dispersion matrix using celite as dispersant sorbent, alumina as clean up sorbent and hexane-dichloromethane (7:3, v/v) mixture as eluting solvent. An additional purification step with copper was necessary to eliminate sulphur. Analysis of the sample was performed by GC-ECD. The method was validated with fortified samples at two concentration levels (0.025 and 0.05 mg kg(-1)). Average recovery ranged from 77 to 121% with relative standard deviation between 1 and 18%. The detection limits, which ranged from 0.003 to 0.01 mg kg-1, were lower than those established by the Baden-Wurttemberg directive (0.033 mg kg(-1)).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes a comparison of conventional energy-dispersive X-ray fluorescence (EDXRF) and synchrotron radiation total-reflection X-ray fluorescence (SRTXRF) for Co determination in ruminal fluid from Holstein cow. This element is used as marker for animal nutrition studies. For EDXRF, 200 mu l of the sample were dried on 6.35 mu m Mylar filmat 60 degrees C. The excitation was carried out using an X-ray tube with Mo target and Zr filter operated at 30 kV/ 20 mA. For SRTXRF, 10 mu l of the samplewere pipetted on a Lucite carrier and dried at 60 degrees C. In both the techniques, Ga was used as internal standard and the acquisition time was 200 s. The trueness of both techniques was evaluated through the standard addition method, the recoveries obtained by SRTXRF and EDXRF were 76 and 99%, and the limits of detection, 13 and 240 mu g l(-1), respectively. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study the levels of Cu, Fe, Pb and Zn, determined in hair of healthy children (25-85 months), living at Araraquara (São Paulo, Brasil) are reported. Analytical determinations were carried out by using atomic absorption spectrometry employing an air acetylene flame. The results obtained are discussed with regard to effect of sex and age, as well compared with others analogous studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new methodology for soluble oxalic acid determination in grass samples was developed using a two enzyme reactor in an FIA system. The reactor consisted of 3 U of oxalate oxidase and 100 U of peroxidase immobilized on Sorghum vulgare seeds activated with glutaraldehyde. The carbon dioxide was monitored spectrophotometrically, after reacting with an acid-base indicator (Bromocresol Purple) after it permeated through a PTFE membrane. A linear response range was observed between 0.25 and 1.00mmol l-1 of oxalic acid; the data was fit by the equation A=-0.8(±1.5)+ 57.2(±2.5)[oxalate], with a correlation coefficient of 0.9971 and a relative standard deviation of 2% for n=5. The variance for a 0.25 mmol l-1 oxalic acid standard solution was lower than 4% for 11 measurements. The FIA system allows analysis of 20 samples per hour without prior treatment. The proposed method showed a good correlation with that of the Sigma Kit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Considering the importance of type beta thalassaemias as hereditary syndromes of high significance in different populations of Mediterranean origin and, by extension, in the Brazilian population, the objective of the present study was to determine by PCR/DGGE the gene structures responsible for neutral polymorphisms (frameworks) observed in the human beta globin gene associated with the mutations responsible for type beta thalassaemias in a sample of the Brazilian population and, more specifically, of the population of the State of São Paulo. Patients and methods: Thirty individuals with beta thalassaemic mutations were analyzed: 22 mutations were in codon 39 (C->T), 5 in IVS1-110 (G->A), 2 in IVS1-6 (T->C) and 1 in IVS1-1 (G->A). DNA was extracted and selective amplification was performed by PCR extending from position IVS1 nt 46 to IVS2 nt 126 (474 pb). The product was then analyzed by polyacrylamide gel electrophoresis on a denaturing 10-60% urea/formamide gradient. Results: The results demonstrated that, as expected, the mutations responsible for type beta thalassaemia observed in this population are of Mediterranean origin, with 73% distribution represented by codon 39,17% by IVS1-110, 7% by IVS1-6 and 3% by IVS1-1. In turn, framework distribution seems to indicate a higher frequency of Fr 1-1 in codon 39 and IVS1-110, of Fr 1-3 in IVS1-6 and of Fr 1-2 in IVS1-1. Conclusions: These results permit us to conclude that gene amplification by PCR followed by DGGE is an appropriate method for the separation of DNA molecules that differ even by a single base change and therefore can be utilized to detect the alterations observed in the human beta globin gene. This methodology shows that, using only a pair of primers, it is possible to define the frameworks that are observed in the beta globin gene.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid and simple gas chromatographic method for determinating cyprodinil, fludioxonil, pyrimethanil, and tebuconazole in grapes, must, and wine is described. An on-line microextraction method was used with a one-step extraction-partition procedure. Nitrogen-phosphorus and mass spectrometric detectors were used, because of their low sensitivity and high selectivity. Because of high selectivity of detector, no cleanup was necessary and the extract was concentrated 5 times. Recoveries from fortified grapes, must, and wine ranged from 93 to 110%. Limits of determination were 0.05 mg/kg for cyprodinil and pyrimethanil and 0.10 mg/kg for fludioxonil and tebuconazole.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, an in situ derivatization and extraction method for the determination of pentachlorophenol (PCP) has been applied successfully in the analysis of water samples. The PCP derivative analysis was performed by gas-liquid chromatography with electron capture detection. The limit of detection of the method is 1 μg/L and recoveries averaged 78-108% for PCP acetate at levels of 2, 10 and 20 μg/L.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work is to propose a flow spectrophotometric procedure for manganese determination in steel based on electrochemical oxidation of Mn(II) to Mn(VII) at a Pt electrode surface by means of the catalytic effect of Ag(I). The on-line oxidation step was obtained by injecting sample and electrolyte solution directly into an electrolytic cell. After electrolysis, the injectate was homogenized by bubbling air. The permanganate ions produced were passed through the spectrophotometer where absorbance was monitored at 545 nm. Effects of direct current, silver concentration, timing, flow rates, concentration and composition of support electrolyte were investigated. Direct current and silver content manifested themselves as the most relevant parameters. For determination of manganese in the 5.00 - 150 mg L -1 range (r=0,9998) and 60 s electrolysis time, the sample throughput was 20 h -1. Accuracy was assessed by analyzing ten steel standard reference materials. Results are precise (R.S.D. <3%) and in agreement with certified values of reference materials and with standard methods at 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The determination of 2,4-D (2,4-dichlorophenoxyacetic acid) and Dicamba (2-methoxy-3,6-dichlorobenzoic acid) residues in sugar cane, rice and corn was performed by a supercritical fluid extraction (SFE) method using CO2/acetone as extraction mix and an SFE apparatus developed in our laboratory. The extracts were cleaned up after extraction by both liquid- liquid partition and a Florisil column. Micellar electrokinetic capillary chromatography (MEKC) coupled with ultraviolet on-column detection was used for the analysis of these pesticides. The detection limits were improved by the preparation of a special detection cell with an increased pathlength that gave detection limits of ca. 0.6 pg for 2,4-D and Dicamba. Our results demonstrated that capillary electrophoresis can be a powerful new analytical tool for pesticide residue analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new strategy for minimization of Cu2+ and Pb2+ interferences on the spectrophotometric determination of Cd2+ by the Malachite green (MG)-iodide reaction using electrolytic deposition of interfering species and solid phase extraction of Cd2+ in flow system is proposed. The electrolytic cell comprises two coiled Pt electrodes concentrically assembled. When the sample solution is electrolyzed in a mixed solution containing 5% (v/v) HNO3, 0.1% (v/v) H2SO4 and 0.5 M NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. After electrolysis, the remaining solution passes through an AG1-X8 resin (chloride form) packed minicolumn in which Cd2+ is extracted as CdCl4/2-. Electrolyte compositions, flow rates, timing, applied current, and electrolysis time was investigated. With 60 s electrolysis time, 0.25 A applied current, Pb2+ and Cu2+ levels up to 50 and 250 mg 1-1, respectively, can be tolerated without interference. For 90 s resin loading time, a linear relationship between absorbance and analyte concentration in the 5.00-50.0 μg Cd 1-1 range (r2 = 0.9996) is obtained. A throughput of 20 samples per h is achieved, corresponding to about 0.7 mg MG and 500 mg KI and 5 ml sample consumed per determination. The detection limit is 0.23 μg Cd 1-1. The accuracy was checked for cadmium determination in standard reference materials, vegetables and tap water. Results were in agreement with certified values of standard reference materials and with those obtained by graphite furnace atomic absorption spectrometry at 95% confidence level. The R.S.D. for plant digests and water containing 13.0 μg Cd 1-1 was 3.85% (n = 12). The recoveries of analyte spikes added to the water and vegetable samples ranged from 94 to 104%. (C) 2000 Elsevier Science B.V.