998 resultados para VERTICAL STRUCTURE
Resumo:
In the Sparse Point Representation (SPR) method the principle is to retain the function data indicated by significant interpolatory wavelet coefficients, which are defined as interpolation errors by means of an interpolating subdivision scheme. Typically, a SPR grid is coarse in smooth regions, and refined close to irregularities. Furthermore, the computation of partial derivatives of a function from the information of its SPR content is performed in two steps. The first one is a refinement procedure to extend the SPR by the inclusion of new interpolated point values in a security zone. Then, for points in the refined grid, such derivatives are approximated by uniform finite differences, using a step size proportional to each point local scale. If required neighboring stencils are not present in the grid, the corresponding missing point values are approximated from coarser scales using the interpolating subdivision scheme. Using the cubic interpolation subdivision scheme, we demonstrate that such adaptive finite differences can be formulated in terms of a collocation scheme based on the wavelet expansion associated to the SPR. For this purpose, we prove some results concerning the local behavior of such wavelet reconstruction operators, which stand for SPR grids having appropriate structures. This statement implies that the adaptive finite difference scheme and the one using the step size of the finest level produce the same result at SPR grid points. Consequently, in addition to the refinement strategy, our analysis indicates that some care must be taken concerning the grid structure, in order to keep the truncation error under a certain accuracy limit. Illustrating results are presented for 2D Maxwell's equation numerical solutions.
Resumo:
O presente trabalho incide sobre a análise da eficiência energética dos elevadores. Para se poder entender esta questão, são apresentadas diversas informações que permitem conhecer os factores associados aos consumos de energia activa, procurando-se perceber qual o rendimento destes equipamentos. Inicialmente são analisados os diversos componentes, que fazem parte de um elevador e os locais em que esses componentes são instalados. Abordam-se as diferentes soluções de accionamento, os diversos tipos de utilização e as diferentes tecnologias que podem ser aplicadas. O estudo dos consumos de energia eléctrica dos elevadores, foi efectuado com base na metodologia desenvolvida pelo grupo E4, do programa Utilização Eficiente da Energia, da Comunidade Europeia, cujo suporte foi o DRAFT ISSO/DIS 25745 - 1 Energy Performance of Lifts and Escalators - Part 1: Energy Measurement and Conformance. Os consumos de energia eléctrica serão caracterizados com os elevadores a serem monitorizados individualmente e sem carga na cabina. A apresentação de resultados obtidos terá em linha de conta: a energia eléctrica consumida com o equipamento em modo de funcionamento, ou seja, com este a realizar ciclos completos, e a potência eléctrica consumida com a instalação em modo de standby, ou seja em não operação. No presente trabalho, são divulgados estudos do grupo E4, em que foram monitorizados elevadores em quatro países da Europa: Portugal, Alemanha, Itália e Polónia. Estes estudos permitem estimar os consumos anuais de energia eléctrica, a nível de funcionamento e a nível de standby e estimar o consumo total, seguindo como base a metodologia anteriormente referida. Para se caracterizar o parque Europeu de elevadores, o grupo E4 recorreu à ELA, Associação Europeia de Elevadores, tendo assim sido possível estimar o consumo anual numa Europa a 27, acrescido do parque da Suíça e da Noruega. Pretende-se com isso poder estimar o potencial de redução no consumo energético no parque analisado, com a aplicação das Melhores Tecnologias Disponíveis (MTD) e com a aplicação de tecnologias que ainda estão em fase de desenvolvimento. (MTND). Paralelamente o autor irá apresentar as monitorizações que efectuou a três elevadores, para os quais procurou validar as leituras efectuadas, comparando os consumos obtidos, com os consumos registados pelas monitorizações do grupo E4 e respectivas estimativas de consumos anuais de energia. As monitorizações do autor, serão utilizadas na catalogação desses três equipamentos a nível de classes de eficiência energética, tendo por base a VDI 4707/Part 1 - Lifts - Energy Efficiency - VDI manual Building Services - Volume 5: Transportation Systems. Procura-se, também, criar um método de apoio na tomada de decisão nas diversas fases de um ciclo do elevador, nomeadamente: desde a especificação, a selecção do sistema de accionamento, a selecção dos sistemas auxiliares, a instalação e a operação do elevador, com vista à melhoria da eficiência energética, e á instalação futura ou à modernização dos equipamentos existentes. Abordam-se as barreiras existentes que inibem a mudança no sector de elevação, para a implementação das MTD no parque de elevadores existente ou no desenvolvimento de novas tecnologias que possibilitem a melhoria da eficiência energética, MTND. Por ultimo, aborda-se de forma simples a temática da supervisão técnica nos elevadores, através da monitorização e supervisão dos diversos componentes, com vista à optimização da gestão da manutenção e procurando interligar esta gestão à melhoria da eficiência energética. Consegue-se concluir que apenas com a aplicação das MTD, podem ser obtidos ganhos de eficiência energética, e também que este tema não tem tido a importância que merece, pois, na análise da eficiência energética de um edifício, a eficiência dos elevadores não é tida em consideração. A ausência de legislação específica, que torne a análise da eficiência energética dos elevadores obrigatória, será um dos problemas referidos. Reforça-se que, a potencialidade de poupança energética na Europa não deve ser desprezada.
Resumo:
The effects of the Miocene through Present compression in the Tagus Abyssal Plain are mapped using the most up to date available to scientific community multi-channel seismic reflection and refraction data. Correlation of the rift basin fault pattern with the deep crustal structure is presented along seismic line IAM-5. Four structural domains were recognized. In the oceanic realm mild deformation concentrates in Domain I adjacent to the Tore-Madeira Rise. Domain 2 is characterized by the absence of shortening structures, except near the ocean-continent transition (OCT), implying that Miocene deformation did not propagate into the Abyssal Plain, In Domain 3 we distinguish three sub-domains: Sub-domain 3A which coincides with the OCT, Sub-domain 3B which is a highly deformed adjacent continental segment, and Sub-domain 3C. The Miocene tectonic inversion is mainly accommodated in Domain 3 by oceanwards directed thrusting at the ocean-continent transition and continentwards on the continental slope. Domain 4 corresponds to the non-rifted continental margin where only minor extensional and shortening deformation structures are observed. Finite element numerical models address the response of the various domains to the Miocene compression, emphasizing the long-wavelength differential vertical movements and the role of possible rheologic contrasts. The concentration of the Miocene deformation in the transitional zone (TC), which is the addition of Sub-domain 3A and part of 3B, is a result of two main factors: (1) focusing of compression in an already stressed region due to plate curvature and sediment loading; and (2) theological weakening. We estimate that the frictional strength in the TC is reduced in 30% relative to the surrounding regions. A model of compressive deformation propagation by means of horizontal impingement of the middle continental crust rift wedge and horizontal shearing on serpentinized mantle in the oceanic realm is presented. This model is consistent with both the geological interpretation of seismic data and the results of numerical modelling.
Resumo:
We report in this paper the recent advances we obtained in optimizing a color image sensor based on the laser-scanned-photodiode (LSP) technique. A novel device structure based on a a-SiC:H/a-Si:H pin/pin tandem structure has been tested for a proper color separation process that takes advantage on the different filtering properties due to the different light penetration depth at different wavelengths a-SM and a-SiC:H. While the green and the red images give, in comparison with previous tested structures, a weak response, this structure shows a very good recognition of blue color under reverse bias, leaving a good margin for future device optimization in order to achieve a complete and satisfactory RGB image mapping. Experimental results about the spectral collection efficiency are presented and discussed from the point of view of the color sensor applications. The physics behind the device functioning is explained by recurring to a numerical simulation of the internal electrical configuration of the device.
Resumo:
This work presents preliminary results in the study of a novel structure for a laser scanned photodiode (LSP) type of image sensor. In order to increase the signal output, a stacked p-i-n-p-i-n structure with an intermediate light-blocking layer is used. The image and the scanning beam are incident through opposite sides of the sensor and their absorption is kept in separate junctions by an intermediate light-blocking layer. As in the usual LSP structure the scanning beam-induced photocurrent is dependent on the local illumination conditions of the image. The main difference between the two structures arises from the fact that in this new structure the image and the scanner have different optical paths leading to an increase in the photocurrent when the scanning beam is incident on a region illuminated on the image side of the sensor, while a decreasing in the photocurrent was observed in the single junction LSP. The results show that the structure can be successfully used as an image sensor even though some optimization is needed to enhance the performance of the device.
Resumo:
In this work we report on the structure and magnetic and electrical transport properties of CrO2 films deposited onto (0001) sapphire by atmospheric pressure (AP)CVD from a CrO3 precursor. Films are grown within a broad range of deposition temperatures, from 320 to 410 degrees C, and oxygen carrier gas flow rates of 50-500 seem, showing that it is viable to grow highly oriented a-axis CrO2 films at temperatures as low as 330 degrees C i.e., 60-70 degrees C lower than is reported in published data for the same chemical system. Depending on the experimental conditions, growth kinetic regimes dominated either by surface reaction or by mass-transport mechanisms are identified. The growth of a Cr2O3 interfacial layer as an intrinsic feature of the deposition process is studied and discussed. Films synthesized at 330 degrees C keep the same high quality magnetic and transport properties as those deposited at higher temperatures.
Resumo:
Orientada por: Prof. Doutora Cláudia Lopes
Resumo:
Nos últimos anos, tem-se observado uma preocupação frequente com as questões estratégicas da manutenção, nomeadamente com o plano e modelo a adoptar, face aos constantes progressos que se têm verificado ao nível da incorporação de tecnologia nos equipamentos. A indústria de elevação tem-se dedicado em grande parte à realização de um serviço de manutenção baseado nas boas práticas adquiridas experimentalmente ao longo dos anos, de acordo com a legislação em vigor e com os seus objectivos operacionais de cada empresa. No entanto, existe a necessidade de estabelecer novas políticas de manutenção, que incorporem as mais recentes tendências, científicas e tecnológicas, que identifiquem os graus de criticidade de cada equipamento, de acordo com a sua fiabilidade e com a disponibilidade requerida pelos utilizadores e donos dos equipamentos, com o objectivo de aumentar o nível do serviço prestado e por consequência, a satisfação dos clientes. Tendo como caso de estudo uma empresa que exerce a sua actividade na área da elevação, este trabalho procura identificar os vários aspectos que careciam de melhoria no serviço de manutenção usualmente prestado, procurando dar especial importância ao planeamento, à programação e à metodologia a utilizar, por forma a tornar esse mesmo serviço mais eficiente e eficaz. Por outro lado, um serviço de manutenção, concretamente na área de elevação, pode e deve ser mais diferenciado, mais tangível, mais parametrizado, para que se possa avaliar e medir com mais assertividade a sua execução. São poucos, para não dizer que não existem, os estudos e trabalhos dedicados a este tema, pelo que o desafio deste trabalho foi precisamente esse, o de abordar um tema muito específico, mas de grande importância para o universo empresarial. Por essa razão, foram realizados vários inquéritos e entrevistas a pessoas que exercem a sua actividade profissional nesta área, tendo sido também realizadas auditorias a várias instalações e à forma como convencionalmente os técnicos de manutenção realizam as suas tarefas, com o objectivo de identificar os vários aspectos que careciam de melhoria. Com base nos resultados obtidos e nos conhecimentos adquiridos pelo autor na sua formação académica e ao longo da sua experiência profissional, definiram-se novas estratégias e orientações para a elaboração e implementação de um manual de manutenção, que possa ser seguido pelos técnicos que realizam diariamente o serviço de manutenção nas várias instalações que possuem espalhadas pelas suas rotas de manutenção.
Resumo:
This synopsis summarizes the key chemical and bacteriological characteristics of β-lactams, penicillins, cephalosporins, carbanpenems, monobactams and others. Particular notice is given to first-generation to fifth-generation cephalosporins. This review also summarizes the main resistance mechanism to antibiotics, focusing particular attention to those conferring resistance to broad-spectrum cephalosporins by means of production of emerging cephalosporinases (extended-spectrum β-lactamases and AmpC β-lactamases), target alteration (penicillin-binding proteins from methicillin-resistant Staphylococcus aureus) and membrane transporters that pump β-lactams out of the bacterial cell.
Resumo:
Mestrado em Fisioterapia.
Resumo:
Mononuclear manganese(II) [Mn(kappa O-HL)(2)(CH3OH)(4)] (4), nickel(II) [Ni(kappa O-2, kappa N-L)(H2O)(3)] (5), cadmium(II) [Cd(kappa O-2-HL)(2)(CH3OH)(3)] (7), tetranuclear zinc(II) [Zn-4(mu-OH)(2)(1 kappa O:2 kappa O-HL)(4)(kappa O-HL)(2)(H2O)(4)] (6) and polynuclear aqua sodium(I) [Na(H2O)(2)(mu-H2O)(2)](n)(HL)(n) (2) and magnesium(II) [Mg(OH)(H2O)(mu-H2O)(2)](n)(-HL)(n) (3) complexes were synthesized using 3-(2-carboxyphenyl-hydrazone)pentane-2,4-dione (H2L, 1) as a ligand precursor. The complexes were characterized by single crystal X-ray diffraction, elemental analysis, IR, H-1 and C-13 NMR (for 2, 3, 6 and 7) spectroscopies. Mono- or dianionic deprotonated derivatives of H2L display different coordination modes and lead to topologies and nuclearities of the complexes depending on metal ions and conditions used for the syntheses. Extensive intermolecular H-bonds form supramolecular arrangements in 1D chains (4 and 6), 1D chains of the organic anion and 2D networks of the metal-aqua aggregates (2 and 3), 2D networks (7) or even 3D frameworks (5). Electrochemical studies, by cyclic voltammetry and controlled potential electrolysis, show ligand centred redox processes as corroborated by theoretical DFT calculations in terms of LUMO and HOMO compositions. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
We present new Rayleigh-wave dispersion maps of the western Iberian Peninsula for periods between 8 and 30 s, obtained from correlations of seismic ambient noise, following the recent increase in seismic broadband network density in Portugal and Spain. Group velocities have been computed for each station pair using the empirical Green's functions generated by cross-correlating one-day-length seismic ambient-noise records. The resulting high-path density allows us to obtain lateral variations of the group velocities as a function of period in cells of 0.5 degrees x 0.5 degrees with an unprecedented resolution. As a result we were able to address some of the unknowns regarding the lithospheric structure beneath SW Iberia. The dispersion maps allow the imaging of the major structural units, namely the Iberian Massif, and the Lusitanian and Algarve Meso-Cenozoic basins. The Cadiz Gulf/Gibraltar Strait area corresponds to a strong low-velocity anomaly, which can be followed to the largest period inverted, although slightly shifted to the east at longer periods. Within the Iberian Massif, second-order perturbations in the group velocities are consistent with the transitions between tectonic units composing the massif. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
World Congress of Malacology, Ponta Delgada, July 22-28, 2013.
Resumo:
OBJETIVO: O crescimento de casos de Aids entre mulheres teve como conseqüência o aumento da transmissão vertical da infecção pelo vírus da imunodeficiência adquirida. Medidas de controle dessa modalidade de transmissão foram implementadas a partir de 1996. O objetivo do estudo foi analisar a tendência temporal da transmissão vertical de Aids em crianças brasileiras. MÉTODOS: Foram incluídas no estudo crianças nascidas entre 1990 e 2001 no Brasil. Utilizou-se o banco de casos notificados como Aids em menores de 13 anos, no período de 1990 a 2004. Modelos de regressão exponencial, ajustados à série temporal, forneceram as taxas de variação anual e os valores observados e esperados para todo o período. RESULTADOS: Observou-se tendência significativamente crescente para os casos com ano de nascimento no período anterior à introdução da terapia anti-retroviral, com taxa de crescimento em torno de 12% (t<0,003) ao ano, e com diferenciais entre os Estados entre 5,9% e 31%. A análise dos casos observados e esperados, para cada uma das macrorregiões, mostrou uma redução dos casos para as crianças nascidas a partir de 1997, atingindo cifras consistentemente menores a cada ano. O número de casos notificados para crianças nascidas em 2001 representou menos de 90% dos casos esperados. CONCLUSÕES: Os resultados obtidos sugerem uma resposta favorável à implementação das políticas de intervenção na prevenção da transmissão vertical do HIV, no Brasil, como ocorreu em outras partes do mundo.
Resumo:
The ruthenium(II)-cymene complexes [Ru(eta(6)-cymene)(bha)Cl] with substituted halogenobenzohydroxamato (bha) ligands (substituents = 4-F, 4-Cl, 4-Br, 2,4-F-2, 3,4-F-2, 2,5-F-2, 2,6-F-2) have been synthesized and characterized by elemental analysis, IR, H-1 NMR, C-13 NMR, cyclic voltammetry and controlled-potential electrolysis, and density functional theory (DFT) studies. The compositions of their frontier molecular orbitals (MOs) were established by DFT calculations, and the oxidation and reduction potentials are shown to follow the orders of the estimated vertical ionization potential and electron affinity, respectively. The electrochemical E-L Lever parameter is estimated for the first time for the various bha ligands, which can thus be ordered according to their electron-donor character. All complexes exhibit very strong protein tyrosine kinase (PTK) inhibitory activity, even much higher than that of genistein, the clinically used PTK inhibitory drug. The complex containing the 2,4-difluorobenzohydroxamato ligand is the most active one, and the dependences of the PTK activity of the complexes and of their redox potentials on the ring substituents are discussed. (C) 2012 Elsevier B.V. All rights reserved.