962 resultados para Tube à choc
Resumo:
The article reports density measurements of dipropyl (DPA), dibutyl (DBA) and bis(2-ethylhexyl) (DEHA) adipates, using a vibrating U-tube densimeter, model DMA HP, from Anton Paar GmbH. The measurements were performed in the temperature range (293 to 373) K and at pressures up to about 68 MPa, except for DPA for which the upper limits were 363 K and 65 MPa, respectively. The density data for each liquid was correlated with the temperature and pressure using a modified Tait equation. The expanded uncertainty of the present density results is estimated as 0.2% at a 95% confidence level. No literature density data at pressures higher than 0.1 MPa could be found. DEHA literature data at atmospheric pressure agree with the correlation of the present measurements, in the corresponding temperature range, within +/- 0.11%. The isothermal compressibility and the isobaric thermal expansion were calculated by differentiation of the modified Tait correlation equation. These two parameters were also calculated for dimethyl adipate (DMA), from density data reported in a previous work. The uncertainties of isothermal compressibility and the isobaric thermal expansion are estimated to be less than +/- 1.7% and +/- 1.1%, respectively, at a 95% confidence level. Literature data of isothermal compressibility and isobaric thermal expansivity for DMA have an agreement within +/- 1% and +/- 2.4%, respectively, with results calculated in this work. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
In Part I of the present work we describe the viscosity measurements performed on tris(2-ethylhexyl) trimellitate or 1,2,4-benzenetricarboxylic acid, tris(2-ethylhexyl) ester (TOTM) up to 65 MPa and at six temperatures from (303 to 373)K, using a new vibrating-wire instrument. The main aim is to contribute to the proposal of that liquid as a potential reference fluid for high viscosity, high pressure and high temperature. The present Part II is dedicated to report the density measurements of TOTM necessary, not only to compute the viscosity data presented in Part I, but also as complementary data for the mentioned proposal. The present density measurements were obtained using a vibrating U-tube densimeter, model DMA HP, using model DMA5000 as a reading unit, both instruments from Anton Paar GmbH. The measurements were performed along five isotherms from (293 to 373)K and at eleven different pressures up to 68 MPa. As far as the authors are aware, the viscosity and density results are the first, above atmospheric pressure, to be published for TOTM. Due to TOTM's high viscosity, its density data were corrected for the viscosity effect on the U-tube density measurements. This effect was estimated using two Newtonian viscosity standard liquids, 20 AW and 200 GW. The density data were correlated with temperature and pressure using a modified Tait equation. The expanded uncertainty of the present density results is estimated as +/- 0.2% at a 95% confidence level. Those results were correlated with temperature and pressure by a modified Tait equation, with deviations within +/- 0.25%. Furthermore, the isothermal compressibility, K-T, and the isobaric thermal expansivity, alpha(p), were obtained by derivation of the modified Tait equation used for correlating the density data. The corresponding uncertainties, at a 95% confidence level, are estimated to be less than +/- 1.5% and +/- 1.2%, respectively. No isobaric thermal expansivity and isothermal compressibility for TOTM were found in the literature. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
This review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice.
Resumo:
A realização deste trabalho teve como principal objectivo proceder ao projecto e realização de dois sistemas de produção de perfis pultrudidos híbridos a acoplar aos equipamentos de pultrusão já instalados na ALTO – PERFIS PULTRUDIDOS, Lda. A realização de perfis pultrudidos híbridos visa melhorar as características de isolamento térmico e acústico dos tubos habitualmente feitos por pultrusão, incrementando simultaneamente a sua resistência, através da melhoria do momento de inércia do perfil, sem que haja um aumento significativo do peso do conjunto. O projecto teve como base de trabalho dois sistemas de produção completamente distintos: (a) a existência de barras de cortiça e de poliuretano (pré-formas) sobre as quais se vai efectuar a pultrusão de um tubo que abraça as barras e (b) o uso de resíduos de pultrusão como forma de enchimento dos tubos, durante o seu processo produtivo. Estes equipamentos foram projectados e parcialmente fabricados, antevendo-se que os mesmos entrem em funcionamento muito brevemente.
Resumo:
Parasitological examinations were carried out during April to August, 1987, with 187 out-patients of the IMIP hospital, located in the center of Recife City, and 464 inhabitants of several villages around Cabo City, 50 Km southeast of Recife, Pernambuco, Brazil. Approximately 71% of the IMIP patients and 92% of the Cabo inhabitants were infected with at least one species of intestinal parasite. There was minimum difference in the prevalence rate of Trichuris trichiura between two areas, whereas the prevalence rates of Ascaris lumbricoides, hookworms, Strongyloides stercoralis, Schistosoma mansoni and Entamoeba histolytica were higher in the inhabitants of the Cabo City area. Only Giardia lamblia was more prevalent in the out-patients of IMIP hospital. Test tube cultivation revealed that the prevalence rate of Necator americanus in both areas was much higher than that of Ancylostoma duodenale , and also that the prevalence rate of S. stercoralis of the IMIP patients and Cabo inhabitants were 4.5% and 9.6%, respectively. Six hundred and fifteen sera were serologically examined for amoebiasis by the gel diffusion precipitation test (GDP) and enzyme linked immunosorbent assay (ELISA) using the antigen prepared from axenically cultured trophozoite of E. histolytica (strain HM-ITMSS). No positive reaction was observed in all of the sera as examined by GDP, while 32 out of 615 sera were positive on ELISA.
Resumo:
A simplified methodology for the quantitative electroelution of proteins from polyacrylamide gels is described. After staining with Coomassie Brilliant Blue R 250, the identified bands are excised from the gel and the proteins eluted using a procedure developed for use in conventional tube gel electrophoresis equipment.
Resumo:
Purpose: This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose for pelvis using automatic exposure control (AEC) and non-AEC in a computed radiography (CR) system. Methods and Materials: To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60-120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the 2 AFC visual grading software. PCXMC software was used to estimate the effective dose. Results: A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p> 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. Effective dose results show a statistical significant decrease (p=0.000) on the 75th quartile from 0.3 mSv at 60 kVp to 0.1 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion: No significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant effective dose reduction is observed.
Resumo:
Parasitological examinations were carried out during July to December, 1989, on 485 inhabitants of four villages in São Lourenço da Mata, 25 km northwest of Recife, Pernambuco, Brazil. Approximately 99.6% of the inhabitants were infected with at least one species of intestinal parasites. A high prevalence of Schistosoma mansoni (82.1%), hookworm (80.2%) Trichuris trichiura (69.9%), Ascaris lumbricoides (61.9%) and Entamoeba coli (36.7%) infections were demonstrated. Test tube cultivation revealed that the most common species of hookworm in this region was Necator americanus (88.4%), and also that the prevalence of Strongyloides stercoralis was 5.8%. Three hundred and thirty-four sera were serologically examined for amoebiasis by the gel diffusion precipitation test (GDP) and enzyme-linked immunosorbent assay (ELISA). No positive reaction was observed in all sera as examined by GDP, while 24 sera were positive by ELISA.
Resumo:
Objective The aim of this study was to determine tympanometric values of children who attend Oporto daycare centers and further analyze any relations with host and environmental factors. Methods Cross sectional study in a randomly selected sample of 117 daycare children up-to 3-years old from Oporto. Tympanometric measures were collected. Results Children presented in left ear (LE) a mean peak pressure (PP) of −156.53 daPa and a mean compliance of 0.16 cm3. Right ear (RE) revealed a PP of −145.61 daPa and a compliance of 0.19 cm3. Normal tympanograms (type A) had a lower frequency than abnormal tympanograms (type B and type C). There was a positive association between age and compliance (LE: p = 0.016; RE: p = 0.013) and between the presence of rhinorrhea and PP (LE: p = 0.002; RE: p < 0.05). Abnormal tympanograms were more frequent in Spring (RE: p = 0.009), in younger children (LE: p = 0.03) and in children that had rhinorrhea (LE: p = 0.002; RE: p = 0.044). Healthy children had a mean PP of −125.19 daPa and a mean compliance of 0.21 cm3 in LE and a mean PP of −144.27 daPa and a mean compliance of 0.22 cm3 in RE. Conclusion Tympanometric measures presented in this paper may be applicable to Oporto daycare children up-to 3 years-old. Most of daycare children revealed abnormal tympanograms. Age, rhinorrhea and season influenced children's middle-ear condition.
Resumo:
The paper reports viscosity measurements of compressed liquid dipropyl (DPA) and dibutyl (DBA) adipates obtained with two vibrating wire sensors developed in our group. The vibrating wire instruments were operated in the forced oscillation, or steady-state mode. The viscosity measurements of DPA were carried out in a range of pressures up to 18. MPa and temperatures from (303 to 333). K, and DBA up to 65. MPa and temperature from (303 to 373). K, covering a total range of viscosities from (1.3 to 8.3). mPa. s. The required density data of the liquid samples were obtained in our laboratory using an Anton Paar vibrating tube densimeter and were reported in a previous paper. The viscosity results were correlated with density, using a modified hard-spheres scheme. The root mean square deviation of the data from the correlation is less than (0.21 and 0.32)% and the maximum absolute relative deviations are within (0.43 and 0.81)%, for DPA and DBA respectively. No data for the viscosity of both adipates could be found in the literature. Independent viscosity measurements were also performed, at atmospheric pressure, using an Ubbelohde capillary in order to compare with the vibrating wire results. The expanded uncertainty of these results is estimated as ±1.5% at a 95% confidence level. The two data sets agree within the uncertainty of both methods. © 2015 Published by Elsevier B.V.
Resumo:
1st European IAHR Congress, 6-4 May, Edinburgh, Scotland
Resumo:
Dissertation presented to obtain a Ph.D. degree in Engineering and Technology Sciences, Systems Biology at the Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa
Resumo:
A single and practical method to slain Malassezia furfur and Corynebacterium minutissimum in lesions' scales is described. The scales are collected by pressing small pieces of scotch tape (about 4 cm lenght and 2 cm width) onto the lesions and following withdrawl the furfuraceous scales will remain on the glue side. These pieces are then immersed for some minutes in lactophenol-cotton blue stain. Following absorption of the stain the scales are washed in current water to remove the excess of blue stain, dried with filter paper, dehydrated via passage in two bottles containing absolute alcohol and then placed in xylene in a centrifugation tube. The xylene dissolves the scotch tape glue and the scales fall free in the tube. After centrifugation and decantation the scales concentrated on the bottom of the tube are collected with a platinum-loop, placed in Canada balsam on a microscopy slide and closed with a cover slip. The preparations are then ready to be submitted to microscopic examination. Other stains may also be used instead of lactophenol-cotton blue. This method is simple, easily performed, and offers good conditions to study these fungi as well as being useful for the diagnosis of the diseases that they cause.
Resumo:
A polymerase chain reaction was carried out to detect pathogenic leptospires isolated from animals and humans in Argentina. A double set of primers (G1/G2, B64-I/B64-II), described before, were used to amplify by PCR a DNA fragment from serogroups belonging to Leptospira interrogans but did not allow to detect saprophytic strains isolated from soil and water (L. biflexa). This fact represents an advantage since it makes possible the differentiation of pathogenic from non-pathogenic leptospires in cultures. The sensitivity of this assay has been determined, allowing to detect just only 10 leptospires in the reaction tube. Those sets of primers generated either a 285 bp or 360 bp fragment, depending on the pathogenic strain
Resumo:
As caldeiras são equipamentos de extrema importância na maioria das indústrias portuguesas. É prática frequente os projectos de caldeiras possuírem apenas cálculos de materiais ou estruturais, nunca abordando as questões térmicas das mesmas. Neste contexto surge o presente trabalho que teve como principal objectivo estudar e modelar o comportamento térmico de uma caldeira alimentada a biomassa florestal. A caldeira em estudo é uma caldeira tubos de fumo com ante-fornalha, alimentada a biomassa e com pressão de funcionamento de 10 bar. A primeira parte do trabalho consistiu no levantamento de toda a informação relativa aos aspectos construtivos da caldeira e as condições de operação da mesma, através da consulta do seu projecto. O estudo do comportamento térmico da caldeira foi dividido em 2 partes: a modelação do comportamento térmico na ante-fornalha seguido da modelação do comportamento térmico do feixe tubular. Na ante fornalha admitiu-se que o calor seria transferido do gás para as paredes da mesma por convecção e por radiação, tendo-se utilizado o Método de Hottel para modelar a transferência de calor por radiação. No feixe tubular a transferência de calor por radiação foi desprezada, tendo-se considerado apenas transferência de calor por condução e convecção entre os gases quentes e a água. Os resultados obtidos mostram que, na ante-fornalha, o peso da potência transferida por radiação (96%) é muito superior à potência transferida por convecção (4%), tendo-se obtido os valores de 384,8 kW e de 16,0 kW para a potência térmica transferida por radiação e por convecção, respectivamente. O valor obtido para a temperatura dos gases na ante-fornalha foi de 1085 K. No feixe tubular a potência térmica transferida por convecção foi de 2559 kW tendo-se obtido o valor de 240ºC para a temperatura de exaustão dos gases pela chaminé. As perdas para o exterior foram estimadas em 1,5 %. O balanço global de energia à caldeira indicou um peso para a potência transferida por convecção de 86,3% e para a potência transferida por radiação de 13,6%. O rendimento da caldeira foi calculado pelo método das perdas tendo-se obtido o valor de 39%.